Petr Stovicek
Research Subjects
Petr Stovicek has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Dan Wichterle
Department of Cardiology Institute for Clinical and Experimental Medicine Prague Czechia
5 shared publications - Stepan Havranek
2nd Department of Medicine—Department of Cardiovascular Medicine of the 1st Faculty of Medicine, Charles University and General University Hospital in Prague
3 shared publications Z Anger
3 shared publications- Ales Linhart
2nd Department of Internal Cardiovascular Medicine, First Faculty of Medicine, Charles University and General University Hospital , Prague
2 shared publications B. Erem
Computational Radiology Lab, Boston Children’s Hospital, Boston (MA), USA
2 shared publicationsBurak Erem
Boston Children's Hospital and Harvard Medical School, Boston, Massachusetts 02115, USA
2 shared publications
Latest Publications
- Open Access
- 29 April 2016
- Published by American Physical Society (APS) in Physical Review E
- Vol. 93 (4) , 042218
Extensions to a manifold learning framework for time-series analysis on dynamic manifolds in bioelectric signals
This paper addresses the challenge of extracting meaningful information from measured bioelectric signals generated by complex, large scale physiological systems such as the brain or the heart. We focus on a combination of the well-known Laplacian eigenmaps machine learning approach with dynamical systems ideas to analyze emergent dynamic behaviors. The method reconstructs the abstract dynamical system phase-space geometry of the embedded measurements and tracks changes in physiological conditions or activities through changes in that geometry. It is geared to extract information from the joint behavior of time traces obtained from large sensor arrays, such as those used in multiple-electrode ECG and EEG, and explore the geometrical structure of the low dimensional embedding of moving time windows of those joint snapshots. Our main contribution is a method for mapping vectors from the phase space to the data domain. We present cases to evaluate the methods, including a synthetic example using the chaotic Lorenz system, several sets of cardiac measurements from both canine and human hearts, and measurements from a human brain.
- 29 April 2016
- Published by American Physical Society (APS) in Physical Review E
- Vol. 93 (4) , 042218
Open AccessExtensions to a manifold learning framework for time-series analysis on dynamic manifolds in bioelectric signals
This paper addresses the challenge of extracting meaningful information from measured bioelectric signals generated by complex, large scale physiological systems such as the brain or the heart. We focus on a combination of the well-known Laplacian eigenmaps machine learning approach with dynamical systems ideas to analyze emergent dynamic behaviors. The method reconstructs the abstract dynamical system phase-space geometry of the embedded measurements and tracks changes in physiological conditions or activities through changes in that geometry. It is geared to extract information from the joint behavior of time traces obtained from large sensor arrays, such as those used in multiple-electrode ECG and EEG, and explore the geometrical structure of the low dimensional embedding of moving time windows of those joint snapshots. Our main contribution is a method for mapping vectors from the phase space to the data domain. We present cases to evaluate the methods, including a synthetic example using the chaotic Lorenz system, several sets of cardiac measurements from both canine and human hearts, and measurements from a human brain.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 217-220
Quantitative comparison of two cardiac electrical imaging methods to localize pacing sites
Electrocardiographic imaging (ECGI) is a technology with great potential to support pre-procedure planning for ablation interventions. However, since the inverse problem it tries to solve is ill-posed, it requires regularization to stabilize the solutions. There have been multiple approaches to attain this objective with different regularization techniques that impose spatial or temporal behaviour on the solution based on prior electrophysiological knowledge with softer or harder constraints. It is continuing research to determine which prior knowledge added is better suited in each situation and there is a need to compare different methods on the same dataset to resolve that question. Here we compare two temporal methods that lie at both sides of the softness/hardness imposition of the prior knowledge. In one hand the splines method by Erem et al. imposes smoothness on the solution, while the cardiac isochrone positioning system (CIPS) forces the solutions to be step-function shaped in time. For this comparison we use the PSTOV dataset from the consortium on electrocardiographic imaging www.ecg-imaging. org which consists of body surface data during pacing at endocardial sites from subjects with healthy ventricles. The results show that on average CIPS performs better than the splines method, although there is too high a degree of variability within and across subjects and pacing locations to be able to predict which method performs better in an individual case.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 217-220
Quantitative comparison of two cardiac electrical imaging methods to localize pacing sites
Electrocardiographic imaging (ECGI) is a technology with great potential to support pre-procedure planning for ablation interventions. However, since the inverse problem it tries to solve is ill-posed, it requires regularization to stabilize the solutions. There have been multiple approaches to attain this objective with different regularization techniques that impose spatial or temporal behaviour on the solution based on prior electrophysiological knowledge with softer or harder constraints. It is continuing research to determine which prior knowledge added is better suited in each situation and there is a need to compare different methods on the same dataset to resolve that question. Here we compare two temporal methods that lie at both sides of the softness/hardness imposition of the prior knowledge. In one hand the splines method by Erem et al. imposes smoothness on the solution, while the cardiac isochrone positioning system (CIPS) forces the solutions to be step-function shaped in time. For this comparison we use the PSTOV dataset from the consortium on electrocardiographic imaging www.ecg-imaging. org which consists of body surface data during pacing at endocardial sites from subjects with healthy ventricles. The results show that on average CIPS performs better than the splines method, although there is too high a degree of variability within and across subjects and pacing locations to be able to predict which method performs better in an individual case.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 957-960
Evaluation of 2-norm versus sparsity regularization in spline-based joint reconstruction of epicardial and endocardial potentials from body-surface measurements
Cardiac electrical imaging, reconstruction of cardiac electrical activity from body surface potentials, has gained increasing clinical interest as a noninvasive imaging modality for underlying electrophysiological phenomena. We have previously presented an approach using 1) a transmural regularization to improve the joint reconstruction of electrical potentials on both the inner and outer surface of the ventricles; and 2) a nonlinear low-order dynamic spline-based parameterization to provide temporal regularization. This approach was tested for localizing endocardial pacing locations obtained from healthy hearts during catheter-based stimulation, using imprecise thorax geometry derived from limited computed tomographic scans. Results were promising, but the reconstructed solutions were overly smooth in space and time. Recently, L1-norm based spatial sparsity methods such as total-variation regularization have been reported to return more realistically sharp solutions in cardiac electrical imaging. In this paper, we compare and evaluate the performance of L2-norm based Tikhonov and L1-norm based total-variation regularization in conjunction with the spline parameterization and the transmural regularization. Numerical experiments were conducted on three subjects, each with multiple (~ 20) endocardial pacing sites and evaluated against true pacing locations reported by the CARTO catheter mapping system. Variability was observed in the performance of the two methods across both pacing sites and subjects. However, the dependence of the results on subjects and ventricular pacing locations suggests that there is some correlation between the results and the specific geometry in each case. In our future work, we will investigate the approach of automatically inferring an optimal regularization norm from the data rather than fixing it a priori.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23258861,p. 957-960
Evaluation of 2-norm versus sparsity regularization in spline-based joint reconstruction of epicardial and endocardial potentials from body-surface measurements
Cardiac electrical imaging, reconstruction of cardiac electrical activity from body surface potentials, has gained increasing clinical interest as a noninvasive imaging modality for underlying electrophysiological phenomena. We have previously presented an approach using 1) a transmural regularization to improve the joint reconstruction of electrical potentials on both the inner and outer surface of the ventricles; and 2) a nonlinear low-order dynamic spline-based parameterization to provide temporal regularization. This approach was tested for localizing endocardial pacing locations obtained from healthy hearts during catheter-based stimulation, using imprecise thorax geometry derived from limited computed tomographic scans. Results were promising, but the reconstructed solutions were overly smooth in space and time. Recently, L1-norm based spatial sparsity methods such as total-variation regularization have been reported to return more realistically sharp solutions in cardiac electrical imaging. In this paper, we compare and evaluate the performance of L2-norm based Tikhonov and L1-norm based total-variation regularization in conjunction with the spline parameterization and the transmural regularization. Numerical experiments were conducted on three subjects, each with multiple (~ 20) endocardial pacing sites and evaluated against true pacing locations reported by the CARTO catheter mapping system. Variability was observed in the performance of the two methods across both pacing sites and subjects. However, the dependence of the results on subjects and ventricular pacing locations suggests that there is some correlation between the results and the specific geometry in each case. In our future work, we will investigate the approach of automatically inferring an optimal regularization norm from the data rather than fixing it a priori.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 1053-1056
A statistical approach to incorporate multiple ECG or EEG recordings with artifactual variability into inverse solutions
Inverse methods for localization and characterization of cardiac and brain sources from ECG and EEG signals are notoriously ill-conditioned and thus sensitive to SNR in the measurements. Multiple recordings of the same underlying phenomenon are often available, but are contaminated by unmodeled correlated noise such as heart motion from respiration or superposition of atrial activation or on-going EEG in the case of inter-ictal spikes or evoked response in EEG. We address here the open question of how best to incorporate these multiple recordings, comparing standard ensemble averaging, a multichannel non-linear spline-based average designed to be less sensitive to timing variations from motion or modulation, and a probalistic inverse incorporating a data-driven model of the noise correlation and using all recordings jointly. Results are tested on localizations of clincally recorded 120 lead ECGs during ventricular pacing.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015, 1053-1056
A statistical approach to incorporate multiple ECG or EEG recordings with artifactual variability into inverse solutions
Inverse methods for localization and characterization of cardiac and brain sources from ECG and EEG signals are notoriously ill-conditioned and thus sensitive to SNR in the measurements. Multiple recordings of the same underlying phenomenon are often available, but are contaminated by unmodeled correlated noise such as heart motion from respiration or superposition of atrial activation or on-going EEG in the case of inter-ictal spikes or evoked response in EEG. We address here the open question of how best to incorporate these multiple recordings, comparing standard ensemble averaging, a multichannel non-linear spline-based average designed to be less sensitive to timing variations from motion or modulation, and a probalistic inverse incorporating a data-driven model of the noise correlation and using all recordings jointly. Results are tested on localizations of clincally recorded 120 lead ECGs during ventricular pacing.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 844-847
Manifold learning for analysis of low-order nonlinear dynamics in high-dimensional electrocardiographic signals
The dynamical structure of electrical recordings from the heart or torso surface is a valuable source of information about cardiac physiological behavior. In this paper, we use an existing data-driven technique for manifold identification to reveal electrophysiologically significant changes in the underlying dynamical structure of these signals. Our results suggest that this analysis tool characterizes and differentiates important parameters of cardiac bioelectric activity through their dynamic behavior, suggesting the potential to serve as an effective dynamic constraint in the context of inverse solutions.
- 1 May 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 844-847
Manifold learning for analysis of low-order nonlinear dynamics in high-dimensional electrocardiographic signals
The dynamical structure of electrical recordings from the heart or torso surface is a valuable source of information about cardiac physiological behavior. In this paper, we use an existing data-driven technique for manifold identification to reveal electrophysiologically significant changes in the underlying dynamical structure of these signals. Our results suggest that this analysis tool characterizes and differentiates important parameters of cardiac bioelectric activity through their dynamic behavior, suggesting the potential to serve as an effective dynamic constraint in the context of inverse solutions.
- 14 February 2012
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 61 (1) , 43-51
Distribution of Mean Cycle Length in Cavo-Tricuspid Isthmus Dependent Atrial Flutter
Although cycle length (CL) constitutes a fundamental descriptor of any arrhythmia, there is not larger study describing mean CL in electrophysiologically confirmed cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). We analyzed retrospectively digital recordings of 121 patients (98 men; age 64±11 years) referred for radiofrequency ablation of persistent CTI-dependent AFL. Median of mean AFL CL was 240 ms (interquartile range (IQR) of 222-258 ms, overall range of 178-399 ms). The distribution of CL was not normal (Shapiro Wilk test, p<0.001). Both counterclockwise and clockwise (14.9 % of all cases) AFLs were comparable in their CL; 240 (IQR 222-258) ms vs. 234 (217-253) ms, respectively. AFL CL<200 ms and AFL CL<190 ms was noticed in 5 (4.1 %) and 3 cases (2.5 %), respectively. In multivariate regression analysis, age (increase by 6±3 ms per decade of age, p=0.036), treatment with specific antiarrhythmic drugs (increase by 11±6 ms, p=0.052) and the history of cardiac surgery (increase by 26±9 ms, p=0.004) were independently associated with AFL CL. In conclusions, the distribution of AFL CL is not normal. The prevalence of AFL with short CL is low. Short CL<200 ms does not rule out the CTI-dependent AFL, especially in young and otherwise healthy patients.
- 14 February 2012
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 61 (1) , 43-51
Distribution of Mean Cycle Length in Cavo-Tricuspid Isthmus Dependent Atrial Flutter
Although cycle length (CL) constitutes a fundamental descriptor of any arrhythmia, there is not larger study describing mean CL in electrophysiologically confirmed cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). We analyzed retrospectively digital recordings of 121 patients (98 men; age 64±11 years) referred for radiofrequency ablation of persistent CTI-dependent AFL. Median of mean AFL CL was 240 ms (interquartile range (IQR) of 222-258 ms, overall range of 178-399 ms). The distribution of CL was not normal (Shapiro Wilk test, p<0.001). Both counterclockwise and clockwise (14.9 % of all cases) AFLs were comparable in their CL; 240 (IQR 222-258) ms vs. 234 (217-253) ms, respectively. AFL CL<200 ms and AFL CL<190 ms was noticed in 5 (4.1 %) and 3 cases (2.5 %), respectively. In multivariate regression analysis, age (increase by 6±3 ms per decade of age, p=0.036), treatment with specific antiarrhythmic drugs (increase by 11±6 ms, p=0.052) and the history of cardiac surgery (increase by 26±9 ms, p=0.004) were independently associated with AFL CL. In conclusions, the distribution of AFL CL is not normal. The prevalence of AFL with short CL is low. Short CL<200 ms does not rule out the CTI-dependent AFL, especially in young and otherwise healthy patients.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S174-S177
Heart Rate Turbulence after Atrial Premature Complexes Depends on Coupling Interval and Atrioventricular Nodal Conduction
Positive Turbulence onset (TO) after atrial premature complexes (APCs) was found temporally related to spontaneous episodes of atrial fibrillation. This study tested the hypothesis that heart rate turbulence (HRT) after APCs is influenced by APC prematurity independently of the prematurity of conducted ventricular complexes.We studied 33 patients (mean age = 58 +/- 16 years, 19 men), 11 of whom had structural heart disease, who were referred for electrophysiological studies of supraventricular or ventricular arrhythmias. Sequences of single right atrial extrastimuli were delivered with coupling intervals adjusted to reach 60% prematurity of conducted ventricular complexes. Descriptors of HRT were compared between patients with slow versus fast atrioventricular (AV) conduction of APCs.The early RR interval dynamics after APCs was prominently modulated by the suppression of sinus node automaticity by the direct effect of APCs. This effect was significantly greater after earlier APCs with longer AV conduction times than after later coupled APCs with shorter AV conduction times.The early phase of HRT is strongly influenced by the coupling interval of APCs, independently of the prematurity of conducted ventricular complexes. Consequently, the more positive TO preceding spontaneous atrial fibrillation episodes might be an epiphenomenon of incidental short-coupled APCs with delayed AV conduction, likely to trigger atrial fibrillation.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S174-S177
Heart Rate Turbulence after Atrial Premature Complexes Depends on Coupling Interval and Atrioventricular Nodal Conduction
Positive Turbulence onset (TO) after atrial premature complexes (APCs) was found temporally related to spontaneous episodes of atrial fibrillation. This study tested the hypothesis that heart rate turbulence (HRT) after APCs is influenced by APC prematurity independently of the prematurity of conducted ventricular complexes.We studied 33 patients (mean age = 58 +/- 16 years, 19 men), 11 of whom had structural heart disease, who were referred for electrophysiological studies of supraventricular or ventricular arrhythmias. Sequences of single right atrial extrastimuli were delivered with coupling intervals adjusted to reach 60% prematurity of conducted ventricular complexes. Descriptors of HRT were compared between patients with slow versus fast atrioventricular (AV) conduction of APCs.The early RR interval dynamics after APCs was prominently modulated by the suppression of sinus node automaticity by the direct effect of APCs. This effect was significantly greater after earlier APCs with longer AV conduction times than after later coupled APCs with shorter AV conduction times.The early phase of HRT is strongly influenced by the coupling interval of APCs, independently of the prematurity of conducted ventricular complexes. Consequently, the more positive TO preceding spontaneous atrial fibrillation episodes might be an epiphenomenon of incidental short-coupled APCs with delayed AV conduction, likely to trigger atrial fibrillation.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S170-S173
Heart Rate Turbulence after Ventricular Pacing Trains During Programmed Ventricular Stimulation
Background: This study tested the hypothesis that heart rate turbulence (HRT) following ventricular pacing trains depends on train cycle length, presence of retrograde ventriculoatrial (VA) conduction, and left ventricular (LV) function. Methods: We analyzed digital recordings of programmed ventricular stimulation (PVS) performed in 82 patients (57 men) referred for electrophysiologic studies of ventricular arrhythmias, whose mean age was 64 ± 12 years and LV ejection fraction (EF) was 47 ± 15%. Profiles of sinus RR intervals after all available 8‐beat ventricular pacing trains (600‐and 400‐ms) were averaged. Heart rate turbulence slope (HRTS) was analyzed as the maximum positive slope of a regression line through a sequence of 2–5 (HRTS2 ‐ HRTS5) consecutive RR intervals within the first 5 RR intervals after the pacing train. Results: Dynamics of RR intervals had biphasic and monophasic patterns, in patients with and without VA conduction, respectively. Sinus nodal response was less prominent after 600‐ms than 400‐ms pacing trains. After 400‐ms pacing trains, HRTS was significantly shallower in patients with LVEF ≤40% than in those with LVEF >40%. HRTS4 was the best discriminator between the two groups (6.8 ± 8.6 ms/RR vs 19.6 ± 26.0 ms/RR, P = 0.017). Conclusion: In patients with VA conduction, HRT after ventricular pacing trains reflects a combination of vagal withdrawal due to transient hypotension and suppression of sinus node automaticity. Attenuation of vagal modulation was detected in patients with LV dysfunction during standard PVS.
- 18 January 2007
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 30 (s1) , S170-S173
Heart Rate Turbulence after Ventricular Pacing Trains During Programmed Ventricular Stimulation
Background: This study tested the hypothesis that heart rate turbulence (HRT) following ventricular pacing trains depends on train cycle length, presence of retrograde ventriculoatrial (VA) conduction, and left ventricular (LV) function. Methods: We analyzed digital recordings of programmed ventricular stimulation (PVS) performed in 82 patients (57 men) referred for electrophysiologic studies of ventricular arrhythmias, whose mean age was 64 ± 12 years and LV ejection fraction (EF) was 47 ± 15%. Profiles of sinus RR intervals after all available 8‐beat ventricular pacing trains (600‐and 400‐ms) were averaged. Heart rate turbulence slope (HRTS) was analyzed as the maximum positive slope of a regression line through a sequence of 2–5 (HRTS2 ‐ HRTS5) consecutive RR intervals within the first 5 RR intervals after the pacing train. Results: Dynamics of RR intervals had biphasic and monophasic patterns, in patients with and without VA conduction, respectively. Sinus nodal response was less prominent after 600‐ms than 400‐ms pacing trains. After 400‐ms pacing trains, HRTS was significantly shallower in patients with LVEF ≤40% than in those with LVEF >40%. HRTS4 was the best discriminator between the two groups (6.8 ± 8.6 ms/RR vs 19.6 ± 26.0 ms/RR, P = 0.017). Conclusion: In patients with VA conduction, HRT after ventricular pacing trains reflects a combination of vagal withdrawal due to transient hypotension and suppression of sinus node automaticity. Attenuation of vagal modulation was detected in patients with LV dysfunction during standard PVS.
- 1 June 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (6) , 628-631
Temporal Pattern of Conduction Recurrence During Radiofrequency Ablation for Typical Atrial Flutter
- 1 June 2006
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 17 (6) , 628-631
Temporal Pattern of Conduction Recurrence During Radiofrequency Ablation for Typical Atrial Flutter
- Open Access
- 1 June 2005
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 7 (Supplement) , 103
319 Temporal pattern of conduction recurrence during radiofrequency ablation for typical atrial flutter
P. Stovicek, M. Fikar, D. Wichterle, M. Aschermann; 319 Temporal pattern of conduction recurrence during radiofrequency ablation for typical atrial flutter, EP
- 1 June 2005
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 7 (Supplement) , 103
Open Access319 Temporal pattern of conduction recurrence during radiofrequency ablation for typical atrial flutter
P. Stovicek, M. Fikar, D. Wichterle, M. Aschermann; 319 Temporal pattern of conduction recurrence during radiofrequency ablation for typical atrial flutter, EP