Winfried Nischkauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Winfried Nischkauer has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Limbeck
TU Wien
12 shared publications - Frank Vanhaecke
Atomic & Mass Spectrometry-A&MS Research Group, Department of Chemistry, Ghent University, Campus Sterre, Krijgslaan 281-S12, 9000 Ghent, Belgium
5 shared publications - Christoph Herwig
Lisalis GmbH, Jenbachgasse 73-2, 1130 Vienna, Austria
2 shared publications - Katharina Bica
Institute of Applied Synthetic Chemistry TU Wien Vienna Austria
2 shared publications Marie-Alexandra Neouze
Ecole Polytechnique, Grp Chim Solide, Lab Phys Mat Condensed, Palaiseau, France
2 shared publicationsSara Hosseinzadegan
2 shared publications
Latest Publications
- Open Access
- 1 June 2021
- Published by Springer Nature in JOM
- Vol. 73 (8) , 2390-2402
Jaws of Platynereis dumerilii: Miniature Biogenic Structures with Hardness Properties Similar to Those of Crystalline Metals
Nanoindentation, laser ablation inductively coupled plasma mass spectroscopy and weighing ion-spiked organic matrix standards revealed structure-property relations in the microscopic jaw structures of a cosmopolitan bristle worm,Platynereis dumerilii. Hardness and elasticity values in the jaws’ tip region, exceeding those in the center region, can be traced back to more metal and halogen ions built into the structural protein matrix. Still, structure size appears as an even more relevant factor governing the hardness values measured on bristle worm jaws across the generaPlatynereis,GlyceraandNereis. The square of the hardness scales with the inverse of the indentation depth, indicating a Nix-Gao size effect as known for crystalline metals. The limit hardness for the indentation depth going to infinity, amounting to 0.53 GPa, appears to be an invariant material property of the ion-spiked structural proteins likely used by all types of bristle worms. Such a metal-like biogenic material is a major source of bio-inspiration.
- 1 June 2021
- Published by Springer Nature in JOM
- Vol. 73 (8) , 2390-2402
Open AccessJaws of Platynereis dumerilii: Miniature Biogenic Structures with Hardness Properties Similar to Those of Crystalline Metals
Nanoindentation, laser ablation inductively coupled plasma mass spectroscopy and weighing ion-spiked organic matrix standards revealed structure-property relations in the microscopic jaw structures of a cosmopolitan bristle worm,Platynereis dumerilii. Hardness and elasticity values in the jaws’ tip region, exceeding those in the center region, can be traced back to more metal and halogen ions built into the structural protein matrix. Still, structure size appears as an even more relevant factor governing the hardness values measured on bristle worm jaws across the generaPlatynereis,GlyceraandNereis. The square of the hardness scales with the inverse of the indentation depth, indicating a Nix-Gao size effect as known for crystalline metals. The limit hardness for the indentation depth going to infinity, amounting to 0.53 GPa, appears to be an invariant material property of the ion-spiked structural proteins likely used by all types of bristle worms. Such a metal-like biogenic material is a major source of bio-inspiration.
- Open Access
- 1 May 2019
- Published by Elsevier in Microchemical Journal
- Vol. 146, 339-344
FI-ICP-OES determination of Pb in drinking water after pre-concentration using magnetic nanoparticles coated with ionic liquid
- 1 May 2019
- Published by Elsevier in Microchemical Journal
- Vol. 146, 339-344
Open AccessFI-ICP-OES determination of Pb in drinking water after pre-concentration using magnetic nanoparticles coated with ionic liquid
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1043, 11-19
Multi-element analysis of size-segregated fine and ultrafine particulate via Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
- 1 December 2018
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1043, 11-19
Multi-element analysis of size-segregated fine and ultrafine particulate via Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
- Open Access
- 6 July 2017
- Published by Springer Nature in AMB Express
- Vol. 7 (1) , 1-12
Photosynthetic poly-β-hydroxybutyrate accumulation in unicellular cyanobacterium Synechocystis sp. PCC 6714
Poly-β-hydroxybutyrate (PHB) production from CO2 has the potential to reduce the production cost of this biodegradable polyesters, and also to make the material more sustainable compared to utilization of sugar feedstocks. In this study the unicellular cyanobacterium, Synechocystis sp. PCC 6714 has been identified as an unexplored potential organism for production of PHB. Synechocystis sp. PCC 6714 was studied under various cultivation conditions and nutritional limitations. Combined effects of nitrogen and phosphorus deficiency led to highest PHB accumulation under photoautotrophic conditions. Multivariate experimental design and quantitative bioprocess development methodologies were used to identify the key cultivation parameters for PHB accumulation. Biomass growth and PHB accumulation were studied under controlled defined conditions in a lab-scale photobioreactor. Specific growth rates were fourfold higher in photobioreactor experiments when cultivation conditions were controlled. After 14 days of cultivation in nitrogen and phosphorus, limited media intracellular PHB levels reached up to 16.4% from CO2. The highest volumetric production rate of PHB was 59 ± 6 mg L−1 day−1. Scanning electron microscopy of isolated PHB granules of Synechocystis sp. PCC 6714 cultivated under nitrogen and phosphorus limitations showed an average diameter of 0.7 µm. The results of this study might contribute towards a better understanding of photoautotrophic PHB production from cyanobacteria.
- 6 July 2017
- Published by Springer Nature in AMB Express
- Vol. 7 (1) , 1-12
Open AccessPhotosynthetic poly-β-hydroxybutyrate accumulation in unicellular cyanobacterium Synechocystis sp. PCC 6714
Poly-β-hydroxybutyrate (PHB) production from CO2 has the potential to reduce the production cost of this biodegradable polyesters, and also to make the material more sustainable compared to utilization of sugar feedstocks. In this study the unicellular cyanobacterium, Synechocystis sp. PCC 6714 has been identified as an unexplored potential organism for production of PHB. Synechocystis sp. PCC 6714 was studied under various cultivation conditions and nutritional limitations. Combined effects of nitrogen and phosphorus deficiency led to highest PHB accumulation under photoautotrophic conditions. Multivariate experimental design and quantitative bioprocess development methodologies were used to identify the key cultivation parameters for PHB accumulation. Biomass growth and PHB accumulation were studied under controlled defined conditions in a lab-scale photobioreactor. Specific growth rates were fourfold higher in photobioreactor experiments when cultivation conditions were controlled. After 14 days of cultivation in nitrogen and phosphorus, limited media intracellular PHB levels reached up to 16.4% from CO2. The highest volumetric production rate of PHB was 59 ± 6 mg L−1 day−1. Scanning electron microscopy of isolated PHB granules of Synechocystis sp. PCC 6714 cultivated under nitrogen and phosphorus limitations showed an average diameter of 0.7 µm. The results of this study might contribute towards a better understanding of photoautotrophic PHB production from cyanobacteria.
- 22 February 2017
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 71 (7) , 1613-1620
Combining Dispersed Particle Extraction with Dried-Droplet Laser Ablation ICP-MS for Determining Platinum in Airborne Particulate Matter
A combination of analyte pre-concentration using dispersed particle extraction (DPE) and dried-droplet laser ablation inductively coupled mass spectrometry (LA-ICP-MS) was developed with the aim to quantify Pt and Pd in urban particulate matter with an aerodynamic diameter ≤2.5 µm (PM 2.5 ). The PM 2.5 aerosol was collected on cellulose ester filters during a sampling period of three days, with sampling intervals of 4 h only. Each of the filters was chemically digested, and the resulting solution was pre-concentrated using DPE. Droplets taken from the pre-concentrated sample were deposited on polymeric disks and dried. These dry spots were then analyzed by means of LA-ICP-MS. This approach allowed ICP-MS analysis of solutions with high content of dissolved sorbent particles coming from the DPE procedure. Furthermore, spectral interferences arising from sample-inherent matrix elements as well as solvent-related interferences could be removed by the proposed approach. The method was validated by determining the Pt concentration in Bureau Communautaire de Référence certified reference material (BCR CRM) 723 road dust certified reference material and a good agreement with the certified value was obtained. The temporal variation of Pt during the three-day sampling period is discussed, with respect to automotive traffic. The daily average of Pt measured in the air corresponds to typical values observed in urban areas in Central Europe. Although the pre-concentration of palladium is feasible with dispersed particle extraction, the method detection limits achieved here did not allow to quantify this element in the CRM or in the PM 2.5 samples. The source for these high method detection limits for palladium are blank values arising from the filter material as well as the digestion procedure of the PM 2.5 samples. Instrumental sensitivity of the approach would, however, suggest that palladium quantification is possible, provided the abovementioned blank issues are controlled better.
- 22 February 2017
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 71 (7) , 1613-1620
Combining Dispersed Particle Extraction with Dried-Droplet Laser Ablation ICP-MS for Determining Platinum in Airborne Particulate Matter
A combination of analyte pre-concentration using dispersed particle extraction (DPE) and dried-droplet laser ablation inductively coupled mass spectrometry (LA-ICP-MS) was developed with the aim to quantify Pt and Pd in urban particulate matter with an aerodynamic diameter ≤2.5 µm (PM 2.5 ). The PM 2.5 aerosol was collected on cellulose ester filters during a sampling period of three days, with sampling intervals of 4 h only. Each of the filters was chemically digested, and the resulting solution was pre-concentrated using DPE. Droplets taken from the pre-concentrated sample were deposited on polymeric disks and dried. These dry spots were then analyzed by means of LA-ICP-MS. This approach allowed ICP-MS analysis of solutions with high content of dissolved sorbent particles coming from the DPE procedure. Furthermore, spectral interferences arising from sample-inherent matrix elements as well as solvent-related interferences could be removed by the proposed approach. The method was validated by determining the Pt concentration in Bureau Communautaire de Référence certified reference material (BCR CRM) 723 road dust certified reference material and a good agreement with the certified value was obtained. The temporal variation of Pt during the three-day sampling period is discussed, with respect to automotive traffic. The daily average of Pt measured in the air corresponds to typical values observed in urban areas in Central Europe. Although the pre-concentration of palladium is feasible with dispersed particle extraction, the method detection limits achieved here did not allow to quantify this element in the CRM or in the PM 2.5 samples. The source for these high method detection limits for palladium are blank values arising from the filter material as well as the digestion procedure of the PM 2.5 samples. Instrumental sensitivity of the approach would, however, suggest that palladium quantification is possible, provided the abovementioned blank issues are controlled better.
- Open Access
- 2 December 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (2) , 212-232
Improvements in the direct analysis of advanced materials using ICP-based measurement techniques
Advanced materials are nowadays used in various industrial and scientific contexts, due to their particular and sometimes unique properties. In many cases, those properties are closely linked to the composition of the materials. An integral part in the characterization of advanced materials is therefore to determine their precise elemental composition, as well as to detect possible contaminants. With this information, the production as well as the properties of the final products can be optimized. To obtain such information in a routinely way, ICP-OES or ICP-MS are versatile tools, since those techniques allow sensitive multi-element analysis in a variety of matrices (e.g., high-purity materials, semiconductors, electronic components, metals, alloys, ceramics, and polymers). However, if using ICP-based techniques in their regular configuration, conversion of the solid material into a liquid solution is necessary. For this purpose, procedures such as acid digestion, fusion or dry ashing have been reported. However, although being well established, the application of these approaches is related with some drawbacks. Besides the problem of jeopardizing information on spatial distribution of analytes, some further shortcomings are risk of sample contamination and/or analyte losses, as well as increased time demand for sample preparation (especially in case of materials with high chemical resistance). Analyzing the solid sample directly is therefore an attractive alternative to conventional liquid analysis. Solid-sampling techniques which are frequently applied in combination with ICP-OES or ICP-MS detection are electro-thermal-vaporization (ETV) and laser-ablation (LA). Besides offering the mentioned advantages in sample preparation, solid-sampling techniques often allow for improvements in sensitivity, since unnecessary sample dilution could be avoided. Furthermore, LA (with restrictions also ETV) offers the possibility of spatially resolved analysis and depth profile analysis, providing information about the distribution of major, minor and trace constituents within the sample. The aim of this review is to discuss new analytical developments in ETV and LA in combination with ICP techniques for the quantitative determination of bulk, trace and ultra-trace elements in the routine analysis of advanced materials.
- 2 December 2016
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 32 (2) , 212-232
Open AccessImprovements in the direct analysis of advanced materials using ICP-based measurement techniques
Advanced materials are nowadays used in various industrial and scientific contexts, due to their particular and sometimes unique properties. In many cases, those properties are closely linked to the composition of the materials. An integral part in the characterization of advanced materials is therefore to determine their precise elemental composition, as well as to detect possible contaminants. With this information, the production as well as the properties of the final products can be optimized. To obtain such information in a routinely way, ICP-OES or ICP-MS are versatile tools, since those techniques allow sensitive multi-element analysis in a variety of matrices (e.g., high-purity materials, semiconductors, electronic components, metals, alloys, ceramics, and polymers). However, if using ICP-based techniques in their regular configuration, conversion of the solid material into a liquid solution is necessary. For this purpose, procedures such as acid digestion, fusion or dry ashing have been reported. However, although being well established, the application of these approaches is related with some drawbacks. Besides the problem of jeopardizing information on spatial distribution of analytes, some further shortcomings are risk of sample contamination and/or analyte losses, as well as increased time demand for sample preparation (especially in case of materials with high chemical resistance). Analyzing the solid sample directly is therefore an attractive alternative to conventional liquid analysis. Solid-sampling techniques which are frequently applied in combination with ICP-OES or ICP-MS detection are electro-thermal-vaporization (ETV) and laser-ablation (LA). Besides offering the mentioned advantages in sample preparation, solid-sampling techniques often allow for improvements in sensitivity, since unnecessary sample dilution could be avoided. Furthermore, LA (with restrictions also ETV) offers the possibility of spatially resolved analysis and depth profile analysis, providing information about the distribution of major, minor and trace constituents within the sample. The aim of this review is to discuss new analytical developments in ETV and LA in combination with ICP techniques for the quantitative determination of bulk, trace and ultra-trace elements in the routine analysis of advanced materials.
- Open Access
- 10 October 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (43) , 7808-7815
Bioparticles coated with an ionic liquid for the pre-concentration of rare earth elements from microwave-digested tea samples and the subsequent quantification by ETV-ICP-OES
An analytical procedure for straight-forward quantification of rare earth elements (REEs) in tea was developed. The method consists of three steps: first, dry tea powder is converted into an aqueous sample solution using a microwave-assisted digestion procedure. Then, the REEs are retained on newly designed sorbent particles and are thus effectively extracted from the sample digest. Then, the REE-loaded sorbent material is introduced into the furnace of an electro-thermal vaporization (ETV) unit. There, the core of the particles is pyrolyzed and removed in a first temperature step. Then, the REE analytes are swiftly evaporated at high temperatures, and subsequently analyzed by ICP-OES. The advantages of the method proposed here are as follows: extraction of REEs is accomplished via “dispersed particle extraction”; this avoids typical shortcomings of conventional solid-phase extraction. The analysis via ETV allows separation of the sorbent particles from the analytes in time. Thus, detrimental effects of plasma-loading are circumvented. The method was shown to provide satisfactory detection limits of typically 50 ng g−1 in the dry tea samples (3 s criterion). The method was validated by means of spike recovery experiments, and applied to the analysis of ten different tea samples from China, Japan and India, as sold in European markets.
- 10 October 2016
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (43) , 7808-7815
Open AccessBioparticles coated with an ionic liquid for the pre-concentration of rare earth elements from microwave-digested tea samples and the subsequent quantification by ETV-ICP-OES
An analytical procedure for straight-forward quantification of rare earth elements (REEs) in tea was developed. The method consists of three steps: first, dry tea powder is converted into an aqueous sample solution using a microwave-assisted digestion procedure. Then, the REEs are retained on newly designed sorbent particles and are thus effectively extracted from the sample digest. Then, the REE-loaded sorbent material is introduced into the furnace of an electro-thermal vaporization (ETV) unit. There, the core of the particles is pyrolyzed and removed in a first temperature step. Then, the REE analytes are swiftly evaporated at high temperatures, and subsequently analyzed by ICP-OES. The advantages of the method proposed here are as follows: extraction of REEs is accomplished via “dispersed particle extraction”; this avoids typical shortcomings of conventional solid-phase extraction. The analysis via ETV allows separation of the sorbent particles from the analytes in time. Thus, detrimental effects of plasma-loading are circumvented. The method was shown to provide satisfactory detection limits of typically 50 ng g−1 in the dry tea samples (3 s criterion). The method was validated by means of spike recovery experiments, and applied to the analysis of ten different tea samples from China, Japan and India, as sold in European markets.
- Open Access
- 30 June 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (21) , 5671-5676
Self-aliquoting micro-grooves in combination with laser ablation-ICP-mass spectrometry for the analysis of challenging liquids: quantification of lead in whole blood
We present a technique for the fast screening of the lead concentration in whole blood samples using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The whole blood sample is deposited on a polymeric surface and wiped across a set of micro-grooves previously engraved into the surface. The engraving of the micro-grooves was accomplished with the same laser system used for LA-ICP-MS analysis. In each groove, a part of the liquid blood is trapped, and thus, the sample is divided into sub-aliquots. These aliquots dry quasi instantly and are then investigated by means of LA-ICP-MS. For quantification, external calibration against aqueous standard solutions was relied on, with iron as an internal standard to account for varying volumes of the sample aliquots. The 208Pb/57Fe nuclide ratio used for quantification was obtained via a data treatment protocol so far only used in the context of isotope ratio determination involving transient signals. The method presented here was shown to provide reliable results for Recipe ClinChek® Whole Blood Control levels I–III (nos. 8840–8842), with a repeatability of typically 3 % relative standard deviation (n = 6, for Pb at 442 μg L−1). Spiked and non-spiked real whole blood was analysed as well, and the results were compared with those obtained via dilution and sectorfield ICP-MS. A good agreement between both methods was observed. The detection limit (3 s) for lead in whole blood was established to be 10 μg L−1 for the laser ablation method presented here. Micro-grooves are filled with whole blood, dried, and analyzed by laser ablation ICP-mass spectrometry. Notice that the laser moves in perpendicular direction with regard to the micro-grooves
- 30 June 2016
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 408 (21) , 5671-5676
Open AccessSelf-aliquoting micro-grooves in combination with laser ablation-ICP-mass spectrometry for the analysis of challenging liquids: quantification of lead in whole blood
We present a technique for the fast screening of the lead concentration in whole blood samples using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The whole blood sample is deposited on a polymeric surface and wiped across a set of micro-grooves previously engraved into the surface. The engraving of the micro-grooves was accomplished with the same laser system used for LA-ICP-MS analysis. In each groove, a part of the liquid blood is trapped, and thus, the sample is divided into sub-aliquots. These aliquots dry quasi instantly and are then investigated by means of LA-ICP-MS. For quantification, external calibration against aqueous standard solutions was relied on, with iron as an internal standard to account for varying volumes of the sample aliquots. The 208Pb/57Fe nuclide ratio used for quantification was obtained via a data treatment protocol so far only used in the context of isotope ratio determination involving transient signals. The method presented here was shown to provide reliable results for Recipe ClinChek® Whole Blood Control levels I–III (nos. 8840–8842), with a repeatability of typically 3 % relative standard deviation (n = 6, for Pb at 442 μg L−1). Spiked and non-spiked real whole blood was analysed as well, and the results were compared with those obtained via dilution and sectorfield ICP-MS. A good agreement between both methods was observed. The detection limit (3 s) for lead in whole blood was established to be 10 μg L−1 for the laser ablation method presented here. Micro-grooves are filled with whole blood, dried, and analyzed by laser ablation ICP-mass spectrometry. Notice that the laser moves in perpendicular direction with regard to the micro-grooves
- Open Access
- 15 September 2015
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (15-16) , 2369-2376
Extraction and pre-concentration of platinum and palladium from microwave-digested road dust via ion exchanging mesoporous silica microparticles prior to their quantification by quadrupole ICP-MS
We report on the use of mesoporous silica microparticles (μPs) functionalized with quarternary amino groups for the isolation of platinum and palladium tetrachloro complexes from aqueous road dust digests. The μPs have a size ranging from 450 to 850 nm and are suspended directly in the aqueous digests, upon which the anionic Pt and Pd complexes are retained on the cationic surface. Subsequently, the μPs are separated by centrifugation. Elements that cause spectral interferences in ICP-MS determination of Pt and Pd can be quantitatively removed by adding fresh 0.240 mol L−1 HCl to the μPs and by repeating the centrifugation step. The analyte-loaded μPs are then dissolved in 0.1 mL of 2 mol L−1 HF, diluted to 2 mL, and the solutions thus obtained are analyzed by quadrupole ICP-MS. This method avoids analyte elution from the sorbent. This “dispersed particle extraction” approach yielded a run-to-run relative standard deviation ≤ 5 % for Pt and ≤ 4 % for Pd (at 0.1 ng mL−1, n = 4 road dust digests). Method detection limits (expressed as concentrations in the dust samples) are 2 and 1 ng g−1 for Pt and Pd, respectively. The method was validated by analysis of a reference material (BCR CRM 723) and applied to the analysis of road dust samples collected in downtown Vienna. Pt and Pd concentrations in samples collected in summer and in winter were compared, with concentrations ranging from 205 to 1445 ng g−1 for Pt and from 201 to 1230 ng g−1 for Pd.
- 15 September 2015
- Published by Springer Nature in Microchimica Acta
- Vol. 182 (15-16) , 2369-2376
Open AccessExtraction and pre-concentration of platinum and palladium from microwave-digested road dust via ion exchanging mesoporous silica microparticles prior to their quantification by quadrupole ICP-MS
We report on the use of mesoporous silica microparticles (μPs) functionalized with quarternary amino groups for the isolation of platinum and palladium tetrachloro complexes from aqueous road dust digests. The μPs have a size ranging from 450 to 850 nm and are suspended directly in the aqueous digests, upon which the anionic Pt and Pd complexes are retained on the cationic surface. Subsequently, the μPs are separated by centrifugation. Elements that cause spectral interferences in ICP-MS determination of Pt and Pd can be quantitatively removed by adding fresh 0.240 mol L−1 HCl to the μPs and by repeating the centrifugation step. The analyte-loaded μPs are then dissolved in 0.1 mL of 2 mol L−1 HF, diluted to 2 mL, and the solutions thus obtained are analyzed by quadrupole ICP-MS. This method avoids analyte elution from the sorbent. This “dispersed particle extraction” approach yielded a run-to-run relative standard deviation ≤ 5 % for Pt and ≤ 4 % for Pd (at 0.1 ng mL−1, n = 4 road dust digests). Method detection limits (expressed as concentrations in the dust samples) are 2 and 1 ng g−1 for Pt and Pd, respectively. The method was validated by analysis of a reference material (BCR CRM 723) and applied to the analysis of road dust samples collected in downtown Vienna. Pt and Pd concentrations in samples collected in summer and in winter were compared, with concentrations ranging from 205 to 1445 ng g−1 for Pt and from 201 to 1230 ng g−1 for Pd.
- Top Cited PapersOpen Access
- 14 July 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (22) , 6593-6617
Recent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry
Laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) is a widely accepted method for direct sampling of solid materials for trace elemental analysis. The number of reported applications is high and the application range is broad; besides geochemistry, LA-ICP-MS is mostly used in environmental chemistry and the life sciences. This review focuses on the application of LA-ICP-MS for quantification of trace elements in environmental, biological, and medical samples. The fundamental problems of LA-ICP-MS, such as sample-dependent ablation behavior and elemental fractionation, can be even more pronounced in environmental and life science applications as a result of the large variety of sample types and conditions. Besides variations in composition, the range of available sample states is highly diverse, including powders (e.g., soil samples, fly ash), hard tissues (e.g., bones, teeth), soft tissues (e.g., plants, tissue thin-cuts), or liquid samples (e.g., whole blood). Within this article, quantification approaches that have been proposed in the past are critically discussed and compared regarding the results obtained in the applications described. Although a large variety of sample types is discussed within this article, the quantification approaches used are similar for many analytical questions and have only been adapted to the specific questions. Nevertheless, none of them has proven to be a universally applicable method.
- 14 July 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (22) , 6593-6617
Top Cited PapersOpen AccessRecent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry
Laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) is a widely accepted method for direct sampling of solid materials for trace elemental analysis. The number of reported applications is high and the application range is broad; besides geochemistry, LA-ICP-MS is mostly used in environmental chemistry and the life sciences. This review focuses on the application of LA-ICP-MS for quantification of trace elements in environmental, biological, and medical samples. The fundamental problems of LA-ICP-MS, such as sample-dependent ablation behavior and elemental fractionation, can be even more pronounced in environmental and life science applications as a result of the large variety of sample types and conditions. Besides variations in composition, the range of available sample states is highly diverse, including powders (e.g., soil samples, fly ash), hard tissues (e.g., bones, teeth), soft tissues (e.g., plants, tissue thin-cuts), or liquid samples (e.g., whole blood). Within this article, quantification approaches that have been proposed in the past are critically discussed and compared regarding the results obtained in the applications described. Although a large variety of sample types is discussed within this article, the quantification approaches used are similar for many analytical questions and have only been adapted to the specific questions. Nevertheless, none of them has proven to be a universally applicable method.