Sandra Lee Carroll
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sandra Lee Carroll has a total of 199 co-authors. Here are the top co-authors by number of shared publications:
- Michael McGillion
Population Health Research Institute, Hamilton, Canada; Departments of Health Research Methods, Evidence, and Impact and Medicine, McMaster University, Hamilton, Canada; World Health Research, Hamilton, Canada
8 shared publications - Dawn Stacey
School of Nursing, University of Ottawa, Ottawa, Canada
7 shared publications Michael McGillion
7 shared publicationsHeather M. Arthur
School of Nursing, McMaster University, Ontario, Canada
5 shared publications- Heather Mary Arthur
Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada
4 shared publications - Jeff Healey
Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada
3 shared publications
Latest Publications
- Open Access
- 27 June 2025
- Published by Elsevier in PEC Innovation
- Vol. 7, 100417
Engaging patient partners to identify research priorities for atrial fibrillation: Results from a patient engagement day
- 27 June 2025
- Published by Elsevier in PEC Innovation
- Vol. 7, 100417
Open AccessEngaging patient partners to identify research priorities for atrial fibrillation: Results from a patient engagement day
- Open Access
- 2 May 2024
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 23 (8) , 877-885
Device-specific quality of life: results from the ATLAS trial—avoid transvenous leads in appropriate subjects
Patient-reported outcomes (PROs) provide important insights into patients’ acceptance of their medical devices. Avoid Transvenous Leads in Appropriate Subjects (ATLAS), a randomized, multi-centre, open-label clinical trial, recently reported fewer perioperative complications in subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous ICD (TV-ICD) patients. This study reports PROs, including device-specific and generic quality of life (QOL), from the ATLAS trial. Device-specific QOL was the primary PRO using the Florida Patient Acceptance Survey (FPAS) at 1 and 6 months’ post-implantation. Secondary outcomes included generic QOL using the Medical Outcomes Survey (SF-36) pre-implant and 6 months’ post-implantation. The FPAS and SF-36 were analysed using analysis of covariance. Pain measured using a Numeric Rating Scale, at 1 and 6 months, anaesthetic, body mass index, and within/between differences were analysed using descriptive statistics and mixed-effects linear models. Of the 503 patients randomized in ATLAS, 404 had complete FPAS data to be included in this analysis. Participant characteristics were balanced. There were no significant differences between S-ICD and TV-ICD for the FPAS or SF-36, across time points. Mean total FPAS scores increased from 73.73 (16.09) to 77.05 (16.13) and 74.43 (15.35) to 78.25 (15.88) for S-ICD and TV-ICD, respectively (P < 0.001). Patient-reported outcomes suggested that both devices were associated with good QOL. Device-specific and generic QOL were similar between S-ICD and TV-ICD groups up to 6 months’ post-implantation, indicating that regardless of device type, both groups reported good device-specific QOL in ATLAS patients. Subcutaneous ICD patients reported higher pain scores at implant, but pain decreased by 6 months. The findings offer evidence that can be included during shared decision-making. The inclusion of patient partners in ATLAS provided an opportunity to measure PROs that were deemed important to patients. ClinialTrials.gov: NCT02881255
- 2 May 2024
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 23 (8) , 877-885
Open AccessDevice-specific quality of life: results from the ATLAS trial—avoid transvenous leads in appropriate subjects
Patient-reported outcomes (PROs) provide important insights into patients’ acceptance of their medical devices. Avoid Transvenous Leads in Appropriate Subjects (ATLAS), a randomized, multi-centre, open-label clinical trial, recently reported fewer perioperative complications in subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous ICD (TV-ICD) patients. This study reports PROs, including device-specific and generic quality of life (QOL), from the ATLAS trial. Device-specific QOL was the primary PRO using the Florida Patient Acceptance Survey (FPAS) at 1 and 6 months’ post-implantation. Secondary outcomes included generic QOL using the Medical Outcomes Survey (SF-36) pre-implant and 6 months’ post-implantation. The FPAS and SF-36 were analysed using analysis of covariance. Pain measured using a Numeric Rating Scale, at 1 and 6 months, anaesthetic, body mass index, and within/between differences were analysed using descriptive statistics and mixed-effects linear models. Of the 503 patients randomized in ATLAS, 404 had complete FPAS data to be included in this analysis. Participant characteristics were balanced. There were no significant differences between S-ICD and TV-ICD for the FPAS or SF-36, across time points. Mean total FPAS scores increased from 73.73 (16.09) to 77.05 (16.13) and 74.43 (15.35) to 78.25 (15.88) for S-ICD and TV-ICD, respectively (P < 0.001). Patient-reported outcomes suggested that both devices were associated with good QOL. Device-specific and generic QOL were similar between S-ICD and TV-ICD groups up to 6 months’ post-implantation, indicating that regardless of device type, both groups reported good device-specific QOL in ATLAS patients. Subcutaneous ICD patients reported higher pain scores at implant, but pain decreased by 6 months. The findings offer evidence that can be included during shared decision-making. The inclusion of patient partners in ATLAS provided an opportunity to measure PROs that were deemed important to patients. ClinialTrials.gov: NCT02881255
- 25 October 2023
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 47 (7) , S52
WHAT IS THE EFFECTIVENESS OF PATIENT DECISION AIDS FOR CARDIOVASCULAR DECISIONS? SUB-ANALYSIS OF A SYSTEMATIC REVIEW
- 25 October 2023
- Published by Elsevier in Canadian Journal of Diabetes
- Vol. 47 (7) , S52
WHAT IS THE EFFECTIVENESS OF PATIENT DECISION AIDS FOR CARDIOVASCULAR DECISIONS? SUB-ANALYSIS OF A SYSTEMATIC REVIEW
- Open Access
- 28 February 2022
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 10 (2) , e24916
Continuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study
Background: Wearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration. Objective: Our aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics. Methods: Included participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability. Results: The validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were –0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time). Conclusions: We found that the Cloud DX’s Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality. Trial Registration: ClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867
- 28 February 2022
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 10 (2) , e24916
Open AccessContinuous Noninvasive Remote Automated Blood Pressure Monitoring With Novel Wearable Technology: A Preliminary Validation Study
Background: Wearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration. Objective: Our aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics. Methods: Included participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability. Results: The validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were –0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time). Conclusions: We found that the Cloud DX’s Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality. Trial Registration: ClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867
- Open Access
- 5 December 2020
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 20 (4) , 367-375
Testing a nurse-led, pre-implantation educational intervention for primary prevention implantable cardioverter-defibrillator candidates: a randomized feasibility trial
Aims: Implantable cardioverter-defibrillators (ICDs) deliver therapy for life-threatening arrhythmias. Evidence suggests that ICD candidates have misconceptions regarding ICD therapy and unmet information needs. We undertook a pilot feasibility trial comparing a nurse-led educational intervention plus standard care, vs. standard pre-ICD implantation care. Secondary aims included examination of anxiety, quality of life, and shock anxiety. Methods and results: Implantable cardioverter-defibrillator candidates were consented and randomized to standard pre-ICD implantation care vs. standard care plus a nurse-led educational intervention. The primary feasibility outcomes included: recruitment rate, consent rate, randomization rate, proportion of participants able to complete all questionnaires, time to deliver intervention, and intervention topics completion. At baseline, demographic and Patient-Reported Outcomes Measurement Information System (PROMIS) anxiety scores were collected. Four weeks post-ICD implantation, participants completed the PROMIS, Florida Patient Acceptance Survey (FPAS), and Florida Shock Anxiety Scale (FSAS). Twenty patients consented (10 per group). Feasibility targets were achieved for all but two outcomes: consent rate was 87% vs. 95% target, and completion of data collection measures was 85% vs. 90% target. Consent rate was lower than expected as one patient declined, and two could not be approached. Completion rate was lower than expected as two patients were lost to follow-up, and one did not receive an ICD during the study period, leading to incomplete post-implantation survey collections. Conclusion: The results demonstrate the feasibility of conducting a trial comparing a nurse-led pre-implantation educational intervention to standard care in an outpatient setting. Further study to evaluate the effectiveness of this intervention on patient-reported outcomes is warranted.
- 5 December 2020
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 20 (4) , 367-375
Open AccessTesting a nurse-led, pre-implantation educational intervention for primary prevention implantable cardioverter-defibrillator candidates: a randomized feasibility trial
Aims: Implantable cardioverter-defibrillators (ICDs) deliver therapy for life-threatening arrhythmias. Evidence suggests that ICD candidates have misconceptions regarding ICD therapy and unmet information needs. We undertook a pilot feasibility trial comparing a nurse-led educational intervention plus standard care, vs. standard pre-ICD implantation care. Secondary aims included examination of anxiety, quality of life, and shock anxiety. Methods and results: Implantable cardioverter-defibrillator candidates were consented and randomized to standard pre-ICD implantation care vs. standard care plus a nurse-led educational intervention. The primary feasibility outcomes included: recruitment rate, consent rate, randomization rate, proportion of participants able to complete all questionnaires, time to deliver intervention, and intervention topics completion. At baseline, demographic and Patient-Reported Outcomes Measurement Information System (PROMIS) anxiety scores were collected. Four weeks post-ICD implantation, participants completed the PROMIS, Florida Patient Acceptance Survey (FPAS), and Florida Shock Anxiety Scale (FSAS). Twenty patients consented (10 per group). Feasibility targets were achieved for all but two outcomes: consent rate was 87% vs. 95% target, and completion of data collection measures was 85% vs. 90% target. Consent rate was lower than expected as one patient declined, and two could not be approached. Completion rate was lower than expected as two patients were lost to follow-up, and one did not receive an ICD during the study period, leading to incomplete post-implantation survey collections. Conclusion: The results demonstrate the feasibility of conducting a trial comparing a nurse-led pre-implantation educational intervention to standard care in an outpatient setting. Further study to evaluate the effectiveness of this intervention on patient-reported outcomes is warranted.
- Top Cited PapersOpen Access
- 10 March 2020
- Published by Wiley in Health Expectations
- Vol. 23 (3) , 523-539
Preparing for patient partnership: A scoping review of patient partner engagement and evaluation in research
Background: Realizing patient partnership in research requires a shift from patient participation in ancillary roles to engagement as contributing members of research teams. While engaging patient partners is often discussed, impact is rarely measured.Objective: Our primary aim was to conduct a scoping review of the impact of patient partnership on research outcomes. The secondary aim was to describe barriers and facilitators to realizing effective partnerships.Search Strategy: A comprehensive bibliographic search was undertaken in EBSCO CINAHL, and Embase, MEDLINE and PsycINFO via Ovid. Reference lists of included articles were hand‐searched.Inclusion Criteria: Included studies were: (a) related to health care; (b) involved patients or proxies in the research process; and (c) reported results related to impact/evaluation of patient partnership on research outcomes.Data Extraction and Synthesis: Data were extracted from 14 studies meeting inclusion criteria using a narrative synthesis approach.Main Results: Patient partners were involved in a range of research activities. Results highlight critical barriers and facilitators for researchers seeking to undertake patient partnerships to be aware of, such as power imbalances between patient partners and researchers, as well as valuing of patient partner roles.Discussion: Addressing power dynamics in patient partner‐researcher relationships and mitigating risks to patient partners through inclusive recruitment and training strategies may contribute towards effective engagement. Further guidance is needed to address evaluation strategies for patient partnerships across the continuum of patient partner involvement in research.Conclusions: Research teams can employ preparation strategies outlined in this review to support patient partnerships in their work.
- 10 March 2020
- Published by Wiley in Health Expectations
- Vol. 23 (3) , 523-539
Top Cited PapersOpen AccessPreparing for patient partnership: A scoping review of patient partner engagement and evaluation in research
Background: Realizing patient partnership in research requires a shift from patient participation in ancillary roles to engagement as contributing members of research teams. While engaging patient partners is often discussed, impact is rarely measured.Objective: Our primary aim was to conduct a scoping review of the impact of patient partnership on research outcomes. The secondary aim was to describe barriers and facilitators to realizing effective partnerships.Search Strategy: A comprehensive bibliographic search was undertaken in EBSCO CINAHL, and Embase, MEDLINE and PsycINFO via Ovid. Reference lists of included articles were hand‐searched.Inclusion Criteria: Included studies were: (a) related to health care; (b) involved patients or proxies in the research process; and (c) reported results related to impact/evaluation of patient partnership on research outcomes.Data Extraction and Synthesis: Data were extracted from 14 studies meeting inclusion criteria using a narrative synthesis approach.Main Results: Patient partners were involved in a range of research activities. Results highlight critical barriers and facilitators for researchers seeking to undertake patient partnerships to be aware of, such as power imbalances between patient partners and researchers, as well as valuing of patient partner roles.Discussion: Addressing power dynamics in patient partner‐researcher relationships and mitigating risks to patient partners through inclusive recruitment and training strategies may contribute towards effective engagement. Further guidance is needed to address evaluation strategies for patient partnerships across the continuum of patient partner involvement in research.Conclusions: Research teams can employ preparation strategies outlined in this review to support patient partnerships in their work.
- Open Access
- 1 January 2020
- Published by SAGE Publications in SAGE Open Nursing
- Vol. 6
Transition Experiences of Caregivers of Older Adults With Dementia and Multiple Chronic Conditions: An Interpretive Description Study
Introduction: Family caregivers provide most of the care for older persons living with dementia (PLWD) and multiple chronic conditions (MCCs) in the community. Caregivers experience transitions, such as changes to their health, roles, and responsibilities, during the process of caring. Transitions encompass a time when caregivers undergo stressful responses to change. However, we know little about the transition experiences of caregivers of persons living with both dementia and MCCs. Objective: This qualitative study explored the transition experiences of caregivers of PLWD within the context of MCCs, from the perspective of both caregivers and practitioners. The research question was the following: What are the transition experiences of family caregivers in providing care to older PLWD and MCCs living in the community? Methods: This study was conducted using an interpretive description approach. Semistructured interviews were conducted with 19 caregivers of older community-dwelling PLWD and MCCs and 7 health-care providers working with caregivers in Ontario, Canada. Concurrent data collection and inductive data analysis were used. Results: Caregivers of older PLWD and MCCs experienced four key transitions: (a) taking on responsibility for managing multiple complex conditions, (b) my health is getting worse, (c) caregiving now defines my social life, and (d) expecting that things will change. Findings highlight how the coexistence of MCCs with dementia complicates caregiver transitions and the importance of social networks for facilitating transitions. Conclusion: The study provided insight on the transition experiences of caregivers of older PLWD and MCCs. MCCs increased the care load and further complicated caregivers’ transition experiences. Health-care providers, such as nurses, can play important roles in supporting caregivers during these transitions and engage them as partners in care.
- 1 January 2020
- Published by SAGE Publications in SAGE Open Nursing
- Vol. 6
Open AccessTransition Experiences of Caregivers of Older Adults With Dementia and Multiple Chronic Conditions: An Interpretive Description Study
Introduction: Family caregivers provide most of the care for older persons living with dementia (PLWD) and multiple chronic conditions (MCCs) in the community. Caregivers experience transitions, such as changes to their health, roles, and responsibilities, during the process of caring. Transitions encompass a time when caregivers undergo stressful responses to change. However, we know little about the transition experiences of caregivers of persons living with both dementia and MCCs. Objective: This qualitative study explored the transition experiences of caregivers of PLWD within the context of MCCs, from the perspective of both caregivers and practitioners. The research question was the following: What are the transition experiences of family caregivers in providing care to older PLWD and MCCs living in the community? Methods: This study was conducted using an interpretive description approach. Semistructured interviews were conducted with 19 caregivers of older community-dwelling PLWD and MCCs and 7 health-care providers working with caregivers in Ontario, Canada. Concurrent data collection and inductive data analysis were used. Results: Caregivers of older PLWD and MCCs experienced four key transitions: (a) taking on responsibility for managing multiple complex conditions, (b) my health is getting worse, (c) caregiving now defines my social life, and (d) expecting that things will change. Findings highlight how the coexistence of MCCs with dementia complicates caregiver transitions and the importance of social networks for facilitating transitions. Conclusion: The study provided insight on the transition experiences of caregivers of older PLWD and MCCs. MCCs increased the care load and further complicated caregivers’ transition experiences. Health-care providers, such as nurses, can play important roles in supporting caregivers during these transitions and engage them as partners in care.
- Open Access
- 1 September 2018
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 12, 1947-1954
“I don’t know exactly what you’re referring to”: the challenge of values elicitation in decision making for implantable cardioverter-defibrillators
Purpose: Patients’ values are a key component of patient-centered care and shared decision making in health care organizations. There is limited understanding on how patients’ values guide their health related decision making or how patients understand the concept of values during these processes. This study investigated patients’ understanding of their values in the context of considering the risks/benefits of receiving an implantable cardioverter-defibrillator (ICD). Patients and methods: A qualitative substudy was conducted within a feasibility trial with first-time ICD candidates randomized to receive a patient decision aid or usual care prior to specialist consultation. Semi-structured interviews were conducted with participants post-implantation or post-specialist consultation. Results: Sixteen patients (ten male) aged 47–87 years participated. Of these, ten (62.5%) received the patient decision aid prior to specialist consultation. Findings revealed patients were confused by the word “values” and had difficulty expressing values related to risks/benefits during ICD decision making. When probed, values were conceptualized broadly capturing other factors such as desire to live, good quality of life, family’s views, ICD information, control over decision, and medical authority. Conclusion: This study revealed the difficulty patients considering an ICD had with articulating their values in the context of an ICD health decision and highlighted the challenge to effectively elicit patients’ values within health decisions overall. It is suggested that there should be a shift away from the use of the word “values” when speaking directly to patients toward language such as “what matters to you the most” or “what is most important to you”.
- 1 September 2018
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 12, 1947-1954
Open Access“I don’t know exactly what you’re referring to”: the challenge of values elicitation in decision making for implantable cardioverter-defibrillators
Purpose: Patients’ values are a key component of patient-centered care and shared decision making in health care organizations. There is limited understanding on how patients’ values guide their health related decision making or how patients understand the concept of values during these processes. This study investigated patients’ understanding of their values in the context of considering the risks/benefits of receiving an implantable cardioverter-defibrillator (ICD). Patients and methods: A qualitative substudy was conducted within a feasibility trial with first-time ICD candidates randomized to receive a patient decision aid or usual care prior to specialist consultation. Semi-structured interviews were conducted with participants post-implantation or post-specialist consultation. Results: Sixteen patients (ten male) aged 47–87 years participated. Of these, ten (62.5%) received the patient decision aid prior to specialist consultation. Findings revealed patients were confused by the word “values” and had difficulty expressing values related to risks/benefits during ICD decision making. When probed, values were conceptualized broadly capturing other factors such as desire to live, good quality of life, family’s views, ICD information, control over decision, and medical authority. Conclusion: This study revealed the difficulty patients considering an ICD had with articulating their values in the context of an ICD health decision and highlighted the challenge to effectively elicit patients’ values within health decisions overall. It is suggested that there should be a shift away from the use of the word “values” when speaking directly to patients toward language such as “what matters to you the most” or “what is most important to you”.