CZChongxing Zhang

Chongxing Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chongxing Zhang has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Accurate Internal Temperature Estimation for Lithium-Ion Battery Based on Modified Electro-Thermal Coupling Model with Online Electrochemical Impedance Spectroscopy Measurement

    by Rui Chen, Ming Dong, Weikai Sun, Kexie Hu, Ming Ren, Chongxing Zhang, Wanjun Lei

    Accurate estimation of lithium-ion battery internal temperature is crucial for ensuring safety, and longevity, particularly under high-rate operating conditions where significant internal-to-surface temperature gradients develop. The present study establishes a modified electro‐thermal coupling model that integrates an equivalent circuit model (ECM) with a lumped‐parameter thermal model (LPTM) in a dynamic framework. Initially, both models utilized static parameters. In the modified approach, the ohmic resistance R 0 and polarization resistance R 1 of the ECM are dynamically identified through electrochemical impedance spectroscopy (EIS). Concurrently, the heat generation rate Q total is calculated from the Bernardi model, and the resulting internal temperature T c is fed back to the ECM, where its parameters are corrected via the Arrhenius relation, thereby achieving real‐time parameter updating under varying operating conditions. The coupled model is formulated using a thermal resistance‐capacitance network and solved with a first‐order transient thermal equation. Furthermore, an adaptive extended Kalman filter (AEKF) is applied to refine the estimation, significantly enhancing the accuracy and robustness of internal temperature prediction. Experimental validation under 1C/2C constant-current discharge demonstrates a maximum absolute error of 0.45 °C and a relative error below 0.69%. The proposed coupled model offers an effective solution for internal temperature monitoring in battery thermal management systems.

  • Thermal Aging Classification and Evaluation of Ester-Based Oil–Paper Insulation Using 3-D Fluorescence Spectra

    by Qian Wu, Shuhua Li, Zhili Tian, Jingyi Wang, Yizhuo Hu, Chongxing Zhang, Qiangsheng Gao, Ming Ren, Ming Dong

    With the continuous advancement of the power industry toward higher voltage levels and environmental sustainability, ester-based insulating oils have become a promising dielectric medium for future power equipment due to their excellent electrical performance, renewability, and eco-friendliness. Fluorescence spectroscopy, characterized by its high sensitivity, rapid response, and non-destructive detection capability, has recently become a highly regarded emerging technique for power equipment condition monitoring. Although fluorescence spectroscopy has been widely applied in environmental and petroleum analysis, its application in transformer insulation monitoring remains very limited. This study extends fluorescence spectroscopy to the thermal aging diagnosis of ester-based oil–paper insulation systems, representing one of the first systematic applications of this technique in transformer insulation monitoring. To address the difficulty in accurately assessing the thermal aging state of ester-based oil–paper insulation and the lack of quantitative diagnostic methods, this study established an accelerated thermal aging platform operating at 130 °C and systematically compared the three-dimensional (3D) fluorescence responses of four types of oil–paper insulation systems: natural ester (NE), synthetic ester (SE), modified ester (ME), and mineral oil (MO). Seven spectral characteristic parameters were extracted from the excitation–emission matrix (EEM) to reveal the variations in peak intensity, wavelength shift, and fluorescence attenuation mechanisms during aging. Furthermore, a three-stage degradation model consisting of the weak-link, amorphous, and crystalline regions was adapted and applied based on the degree of polymerization (DP) thresholds of insulation paper, enabling a quantitative correlation between fluorescence features and cellulose degradation mechanisms. In addition, a combined modeling framework integrating partial least squares–discriminant analysis (PLS-DA) for supervised dimensionality reduction and light gradient boosting machine (LightGBM) for classification was proposed, forming a hybrid “mechanism-driven + data-driven” diagnostic scheme. Experimental results demonstrated distinct spectral evolution behaviors among the four oil–paper systems: NE exhibited an “initial enhancement–subsequent attenuation” trend; SE showed a steady increase; ME displayed a slow-to-rapid decline; while MO demonstrated a monotonic decay. The proposed PLS-DA + LightGBM model achieved an average recognition accuracy of 94.48% across the four systems, yielding a 3.43% improvement over the baseline principal component analysis–support vector machine (PCA-SVM) model, with higher robustness and generalization capability. This work establishes a systematic evaluation and intelligent diagnostic method for the 3D fluorescence characteristics of ester-based oil–paper insulation, providing an effective experimental and modeling framework for transformer aging state identification and lifetime assessment.

  • Open Access

    Visualization and Quantitative Inversion of Temperature Distribution for DBC Substrate Based on Electroluminescence

    by Qinyu Zhou, Ming Ren, Kai Wang, Chongxing Zhang, Ming Dong, Yifei Wang

    A novel temperature distribution visualization evaluation method for direct bonded copper (DBC) substrates in medium-high voltage power modules was developed based on square-wave (SW) excitation electroluminescence (EL). Firstly, an EL device with a planar electrode structure was fabricated, and the temperature dependence of the EL integral spectrum was analyzed using the Gaussian multi-peak fitting method. Subsequently, gradient temperature experiments statistically validated the equivalence between the RGB ratio of luminescence images and the integral spectral peak R12, establishing a foundation for RGB-based temperature characterization. Then, systematic investigations of temperature-sensitive parameters were conducted to identify key factors influencing the EL thermosensitive characteristics. Experimental validations and quantitative analysis of temperature measurement sensitivity were performed under applied electric field intensity, prolonged high-temperature testing (2 hours at 300.15K, 372.65K and 407.65K), and thermal-cycling conditions (from 298 K to 450 K for 9 times). A temperature inversion model based on the Gaussian process regression (GPR) algorithm was established using the image G/B channel intensity ratio as the parameter. Finally, the proposed model’s accuracy in temperature field reconstruction was verified on an EL device with spatial temperature gradient distribution and two DBC substrate samples with distinct heating configurations.

  • Evolutionary trajectories of multi-peak transient discharge pulses in gas insulation: a possible criterion for insulation failure risk assessment

    by Ming Ren, Xu Chen, Zhang Yang, Jin Miao, Chongxing Zhang, Ming Dong

    Fault prediction for gas-insulated apparatus poses a critical challenge in the field of condition monitoring. This paper presents a GHz-bandwidth current and optoelectronic measurement system that is designed to monitor the broadband pulse currents and optical pulses of typical gas-insulated defect discharges as they approach critical breakdown. It statistically analyzes the frequency evolution of compact multi-peak pulse clusters at the nanosecond timescale during discharge progression, concluding that their proportion and statistical characteristics vary as the discharge develops. The paper investigates this phenomenon by providing a physical explanation for the generation mechanism of multi-peak pulse clusters and examining their potential as a criterion for insulation failure. In contrast to traditional phase-resolved pulse sequence analysis or ultra-high frequency diagnostics that rely on macroscopic pulse statistics or band-limited electromagnetic responses, the proposed GHz-bandwidth method directly captures nanosecond multi-peak pulse clusters associated with streamer branching, charge redistribution, and precursor-type leader initiation. This work presents a novel method for the early detection of insulation defects in gas-insulated equipment that is more closely aligned with the fundamental physics of discharges, with the potential to overcome the constraints of conventional phase-resolved statistics in the assessment of discharge hazards.

  • Visual Detection of Typical Process Defects in Power Modules and Intelligent Quality Assessment via Electroluminescence Imaging

    by Kai Wang, Ming Ren, Qinyu Zhou, Chongxing Zhang, Ming Dong

    Power electronic systems demand high reliability, yet process defects within direct bonded copper substrates significantly compromise insulation integrity under coupled electrothermal stress. This article introduces a novel visual intelligent detection method based on the electroluminescence (EL) effect that employs a “working condition separation strategy” to quantitatively assess this risk. First, the electric field distribution is mapped under no-load/room temperature conditions to identify static stress concentrations caused by geometric features and defects. Subsequently, the surface temperature distribution is characterized under a representative operational load (0.8 kV dc bus, 100 Ω load resistance), where our EL-based thermometry model achieves a mean absolute error of approximately ±3.2 °C, with peak module temperatures reaching 90 °C. By integrating these distinct electrothermal datasets, a fuzzy logic-based model generates a quantitative, 2-D insulation risk map. The experimental validation on a commercial 1.2 kV/600 A insulated-gate bipolar transistor module demonstrates the framework’s efficacy. The results precisely identify and differentiate high-risk locations, such as a 63% probability of insulation weakness at sharp corners versus a 23% probability along straight trace edges, and quantify their combined stress state. This visual, spatially resolved approach offers a powerful tool for refined quality control, in-depth reliability analysis, and design validation for power modules.