Ian A. Hiskens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ian A. Hiskens has a total of 195 co-authors. Here are the top co-authors by number of shared publications:
- Sijia Geng
Johns Hopkins University
6 shared publications - Johanna L. Mathieu
University of Michigan
5 shared publications - Zhongjing Ma
Beijing Institute of Technology
4 shared publications - Cedric Josz
Réseau de Transport d'Electricité R&D Department EECS Department Argonne National Laboratory Energy Systems Division University of Michigan
3 shared publications - Daniel K. Molzahn
Department of Electrical Engineering and Computer Science University of Michigan 48109 Ann Ar- bor MI USA
3 shared publications - Ioannis M. Granitsas
Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, USA
3 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5488-5497
Infrequent Control of Thermostatically Controlled Loads for Fast Power System Services
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 5488-5497
Infrequent Control of Thermostatically Controlled Loads for Fast Power System Services
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (2) , 1406-1415
Determining Disturbance Recovery Conditions by Inverse Sensitivity Minimization
Power systems naturally experience disturbances, some of which can damage equipment and disrupt consumers. It is important to quickly assess the likely consequences of credible disturbances and take preventive action, if necessary. However, assessing the impact of potential disturbances is challenging because many of the influential factors, such as loading patterns, controller settings and load dynamics, are not precisely known. To address this issue, the paper introduces the concept of parameter-space recovery regions. For each disturbance, the corresponding recovery region is the region of parameter space for which the system will recover to the desired operating point. The boundary of the recovery region establishes the separation between parameter values that result in trouble-free recovery and those that incur undesirable non-recovery. The safety margin for a given set of parameter values is defined as the smallest distance (in parameter space) between the given values and the recovery boundary. Novel numerical algorithms with theoretical guarantees are presented for efficiently computing recovery boundaries and safety margins. Unlike prior methods, which tend to be overly conservative and restricted to low dimensional parameter space, these methods compute safety margins to arbitrary user-specified accuracy and do so efficiently in high dimensional parameter space. The efficacy of the methods is demonstrated using the IEEE 39-bus benchmark power system, where safety margins are computed for cases that consider up to 86 parameters, and reveal unexpected safety implications that would not have been observed otherwise.
- 19 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (2) , 1406-1415
Determining Disturbance Recovery Conditions by Inverse Sensitivity Minimization
Power systems naturally experience disturbances, some of which can damage equipment and disrupt consumers. It is important to quickly assess the likely consequences of credible disturbances and take preventive action, if necessary. However, assessing the impact of potential disturbances is challenging because many of the influential factors, such as loading patterns, controller settings and load dynamics, are not precisely known. To address this issue, the paper introduces the concept of parameter-space recovery regions. For each disturbance, the corresponding recovery region is the region of parameter space for which the system will recover to the desired operating point. The boundary of the recovery region establishes the separation between parameter values that result in trouble-free recovery and those that incur undesirable non-recovery. The safety margin for a given set of parameter values is defined as the smallest distance (in parameter space) between the given values and the recovery boundary. Novel numerical algorithms with theoretical guarantees are presented for efficiently computing recovery boundaries and safety margins. Unlike prior methods, which tend to be overly conservative and restricted to low dimensional parameter space, these methods compute safety margins to arbitrary user-specified accuracy and do so efficiently in high dimensional parameter space. The efficacy of the methods is demonstrated using the IEEE 39-bus benchmark power system, where safety margins are computed for cases that consider up to 86 parameters, and reveal unexpected safety implications that would not have been observed otherwise.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1221-1232
Controlling Air Conditioners for Frequency Regulation: A Real-World Example
Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. We argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 16 (2) , 1221-1232
Controlling Air Conditioners for Frequency Regulation: A Real-World Example
Even though thermostatically controlled loads like air conditioners present a great potential for providing ancillary services to the electric power grid, the practical challenges associated with their real-time coordination have not received the necessary attention. In this work, we present a nondisruptive load control application, specifically, we demonstrate how real residential air conditioners can provide frequency regulation. Aggregate power adjustment is achieved by modifying the ON/OFF modes of the air conditioners. To account for both single and multi-zone houses, we extend the currently available techniques and develop an approach that can be used for controlling aggregations that include both types of houses. A discussion of the practical challenges encountered in our field experiments is provided, along with the hardware and software approaches we developed to circumvent them. We argue that limitations of current thermostat APIs introduce significant challenges and are an impediment to widespread adoption of fast load control applications.
- 6 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads
- 6 July 2024
- Published by Elsevier in Electric Power Systems Research
- Vol. 235
Nonlinear behavior in high-frequency aggregate control of thermostatically controlled loads
- 1 January 2024
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 146 (1) , 1-32
The Sub-Metered HVAC Implemented for Demand Response Dataset
Closed-loop control of commercial building heating, ventilating, and air conditioning (HVAC) for demand response requires measurements used as feedback to the controllers. Demand response effectiveness is usually measured as a power deviation from baseline, but the building automation system (BAS) does not usually collect power measurements, and whole-building electric meters typically measure power at intervals of 15 min, which may be too slow for some types of demand response. Demand response strategies are sometimes focused on components of building HVAC systems, e.g., the response of supply/return fans to temperature set-point changes, but these components are usually not submetered. Fan power can be estimated from physics-based models leveraging BAS data, e.g., airflow measurements; but our ability to effectively close the loop on these estimates is not clear. In this paper, we introduce a massive dataset that contains both submetered fan power data and BAS data for several building HVAC systems during typical operation and demand response events. Through a case study we show that models leveraging BAS data alone do not provide accurate estimates of fan power during event transients, making it unlikely that closed-loop control of commercial building HVAC components for demand response would be effective using BAS data alone. This demonstrates the value of submetering HVAC components. More broadly, our dataset will enable future research bridging the gap between building control and power systems research.
- 1 January 2024
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 146 (1) , 1-32
The Sub-Metered HVAC Implemented for Demand Response Dataset
Closed-loop control of commercial building heating, ventilating, and air conditioning (HVAC) for demand response requires measurements used as feedback to the controllers. Demand response effectiveness is usually measured as a power deviation from baseline, but the building automation system (BAS) does not usually collect power measurements, and whole-building electric meters typically measure power at intervals of 15 min, which may be too slow for some types of demand response. Demand response strategies are sometimes focused on components of building HVAC systems, e.g., the response of supply/return fans to temperature set-point changes, but these components are usually not submetered. Fan power can be estimated from physics-based models leveraging BAS data, e.g., airflow measurements; but our ability to effectively close the loop on these estimates is not clear. In this paper, we introduce a massive dataset that contains both submetered fan power data and BAS data for several building HVAC systems during typical operation and demand response events. Through a case study we show that models leveraging BAS data alone do not provide accurate estimates of fan power during event transients, making it unlikely that closed-loop control of commercial building HVAC components for demand response would be effective using BAS data alone. This demonstrates the value of submetering HVAC components. More broadly, our dataset will enable future research bridging the gap between building control and power systems research.
- Open Access
- 25 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 111 (8) , C2
Proceedings of the IEEE Publication Information
- 25 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings of the IEEE
- Vol. 111 (8) , C2
Open AccessProceedings of the IEEE Publication Information
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems
- Vol. 43 (2) , 14-15
IEEE Control Systems Society Technical Committee on Smart Grid [Technical Activities]
- 24 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Control Systems
- Vol. 43 (2) , 14-15
IEEE Control Systems Society Technical Committee on Smart Grid [Technical Activities]
- Open Access
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 9, 489-500
Unified Grid-Forming/Following Inverter Control
The paper describes an inverter control scheme which incorporates both a phase-locked loop (PLL) for voltage synchronization and power-frequency droop for load sharing. As such, it is a hybrid grid-forming/following controller and offers beneficial characteristics of both. The model describing behaviour is presented and connections with grid-forming and grid-following control strategies are considered. A process for black-starting the PLL-based inverter control scheme is described. Case studies explore controller small-and large-disturbance performance under a variety of system conditions.
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 9, 489-500
Open AccessUnified Grid-Forming/Following Inverter Control
The paper describes an inverter control scheme which incorporates both a phase-locked loop (PLL) for voltage synchronization and power-frequency droop for load sharing. As such, it is a hybrid grid-forming/following controller and offers beneficial characteristics of both. The model describing behaviour is presented and connections with grid-forming and grid-following control strategies are considered. A process for black-starting the PLL-based inverter control scheme is described. Case studies explore controller small-and large-disturbance performance under a variety of system conditions.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3370-3380
Convergence of Distributed Steinmetz Control for Balancing Distribution Network Voltages
The paper establishes convergence properties of decentralized and distributed control strategies that use a Steinmetz-based technique for mitigating voltage unbalance on distribution feeders. Reactive power from distributed energy resources (DERs), such as solar photovoltaic (PV), is used to balance voltages at critical nodes in the distribution network. Interactions between controllers are analyzed and a theoretical guarantee is derived for stability of the control algorithms. This is achieved using Banach fixed-point theory. Providing such convergence results ensures robustness of the proposed control algorithms in realistic settings where parameters are uncertain and/or slowly varying, disturbances are prevalent, and control and measurement signals are prone to delays. The convergence results are evaluated on three test distribution networks.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (5) , 3370-3380
Convergence of Distributed Steinmetz Control for Balancing Distribution Network Voltages
The paper establishes convergence properties of decentralized and distributed control strategies that use a Steinmetz-based technique for mitigating voltage unbalance on distribution feeders. Reactive power from distributed energy resources (DERs), such as solar photovoltaic (PV), is used to balance voltages at critical nodes in the distribution network. Interactions between controllers are analyzed and a theoretical guarantee is derived for stability of the control algorithms. This is achieved using Banach fixed-point theory. Providing such convergence results ensures robustness of the proposed control algorithms in realistic settings where parameters are uncertain and/or slowly varying, disturbances are prevalent, and control and measurement signals are prone to delays. The convergence results are evaluated on three test distribution networks.
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (2) , 837-846
Efficient Computation of Minimal Wind-Power Deviations That Induce Temporal Line Overloading
The paper develops an optimization method for assessing transmission network vulnerability to small changes in generation (as caused, for example, by wind forecast inaccuracy). The method computes the smallest deviation (in a weighted 2-norm sense) from the nominal generation pattern that would drive a particular line to a specified temperature, over a given time horizon. The 2-norm weighting matrix provides a means of capturing spatial and temporal coupling between generation sites and time intervals. The temperature constraint is second-order in voltage angle differences. The problem is therefore a quadratically-constrained quadratic program (QCQP). Solving the QCQP for each line in the network yields a set of candidate generation deviation patterns which may then be sorted to determine the lines that are most vulnerable to overloading. The paper develops a computationally efficient algorithm for solving this QCQP. An example explores line-overload vulnerability due to changes in wind patterns. Numerical results emphasize the framework's ability to incorporate evolving ambient and system conditions, as well as computational scaling properties.
- 10 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (2) , 837-846
Efficient Computation of Minimal Wind-Power Deviations That Induce Temporal Line Overloading
The paper develops an optimization method for assessing transmission network vulnerability to small changes in generation (as caused, for example, by wind forecast inaccuracy). The method computes the smallest deviation (in a weighted 2-norm sense) from the nominal generation pattern that would drive a particular line to a specified temperature, over a given time horizon. The 2-norm weighting matrix provides a means of capturing spatial and temporal coupling between generation sites and time intervals. The temperature constraint is second-order in voltage angle differences. The problem is therefore a quadratically-constrained quadratic program (QCQP). Solving the QCQP for each line in the network yields a set of candidate generation deviation patterns which may then be sorted to determine the lines that are most vulnerable to overloading. The paper develops a computationally efficient algorithm for solving this QCQP. An example explores line-overload vulnerability due to changes in wind patterns. Numerical results emphasize the framework's ability to incorporate evolving ambient and system conditions, as well as computational scaling properties.