Hasan Obeid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hasan Obeid has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Pierre Boutouyrie
Department of Pharmacology, Université de Paris Cité, DMU CARTE, Hôpital Européen Georges Pompidou (HEGP), Assistance Publique Hôpitaux de Paris, Paris Cardiovascular Research Centre INSERM, France (P.B., S.B.).
6 shared publications Magid Hallab
Clinique Bizet, Cardiology unit , Paris, France
4 shared publicationsPierre Boutouyrie
INSERM-U970, Paris Cardiovascular Research Center, Paris, France
4 shared publications- Catherine Fortier
Endocrinology and Nephrology Axis, Centre hospitalier universitaire de Québec Research Center, Faculty and Department of Medicine, Université Laval, Quebec City, Canada (M.A., C.F.).
3 shared publications Charles-Antoine Garneau
CHU de Québec Research Center-Université Laval, L’Hôtel-Dieu de Québec Hospital, Québec, QC, Canada
3 shared publicationsHakim Khettab
INSERM-U970, Paris Cardiovascular Research Center, Paris, France
3 shared publications
Latest Publications
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Assessing aortic stiffness from finger-toe measurements : modeling and clinical application
Mesure de la rigidité aortique par abord doigt-orteil : modélisation et application clinique: Un temps de transit peut être mesuré entre le doigt et l'orteil. Si cette mesure est liée au temps de transit carotide-fémoral et si cela est représentatif de la rigidité aortique, était l'objet principal de la présente thèse. En effet, le chemin suivi par les pouls est complexe et la compréhension commune était que le temps nécessaire pour atteindre le doigt, le pouls avait déjà atteint la cuisse, et donc il devrait être lié au temps de transit aortique. En fait, l'accord entre la vitesse de l'onde de pouls doigt-orteil (VOP-do) et la VOP carotide-femorale (VOP-cf) est plutôt bien puisque les études préliminaires ont montré une corrélation acceptable (r² = 0,43; RMSE = 1,3 m / s pour VOP) entre la VOP au pied du doigt (VOP-do) mesuré par le pOpmetre et VOP-cf mesurés par le système SphygmoCor (Alivon et al., 2015). Le mérite de cette étude était de montrer que nous devrions réinvestir la physique de la propagation des ondes pour expliquer cet accord étonnamment bon. Cependant, il a également souligné un manque d'exactitude dans des conditions spécifiques, notamment chez les personnes âgées obèses. Des analyses préliminaires ont suggéré qu'il pourrait être surmonté par des algorithmes et des procédures optimisés. Nous avons émis l'hypothèse que l'évaluation de la rigidité aortique peut être approchée de manière fiable par la VOP-do, car les propriétés mécaniques des artères périphériques sont neutres et ne affectent pas le temps de transit qui est principalement conditionné par la rigidité aortique, en supposant que la différence de temps de transit entre un membre inférieur et un membre supérieur annuleraient la propagation de l'onde de pouls sur les artères périphériques rigides, c'est-à-dire que les temps de transit dans les membres supérieurs et inférieurs sont comparables. En effet, bien que le pOpmetre enregistre l'onde de pouls dans les artères distales, la différence de temps de transit reflète essentiellement la propagation le long de l'aorte thoracique et abdominale. Par conséquent, la VOP-do doit être lié à la rigidité aortique, mesurée par la méthode de référence (VOP-cf). En conséquence, les objectifs de la présente thèse sont divisés en deux parties principales : Partie clinique : en augmentant le nombre et en faisant varier les caractéristiques des sujets pour l'étude de validation du système pOpmetre. (1) Étudier la robustesse de l'algorithme de détection du pied d'onde utilisé par le système pOpmètre. (2) Testez la cohérence de la chaîne de traitement du signal. (3) Vérifiez si la combinaison du meilleur algorithme de détection de pied avec une chaîne de traitement de signal optimisée améliore encore l'accord entre la VOP-do et la VOP-cf, l'étalon-or. (4) Ré-mesurer les sujets de premiers travail avec les algorithmes optimisés. Partie numérique: testez la validité de l'hypothèse physique sur laquelle le système pOpmetre est basé (1) en étendant le modèle 1D existant pour l'arbre artériel avec les circulations main et pied, pour permettre l'évaluation de la VOP-do. (2) Utilisez le modèle de réseau artériel 1D étendu de la circulation systémique pour comparer les performances de la méthode VOP-do avec la méthode de référence. (3) Effectuer une étude de paramètres pour évaluer la validité de différentes méthodes de VOP basées sur les mesures des artères périphériques, en obtenant une meilleure compréhension et validation de leurs principes de travail tout en modifiant les propriétés mécaniques de l'élastique central (aorte, carotide) et / ou artères périphérique / musculaire (brachiale, radiale, fémorale, tibiale, doigt, orteil).
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Assessing aortic stiffness from finger-toe measurements : modeling and clinical application
Mesure de la rigidité aortique par abord doigt-orteil : modélisation et application clinique: Un temps de transit peut être mesuré entre le doigt et l'orteil. Si cette mesure est liée au temps de transit carotide-fémoral et si cela est représentatif de la rigidité aortique, était l'objet principal de la présente thèse. En effet, le chemin suivi par les pouls est complexe et la compréhension commune était que le temps nécessaire pour atteindre le doigt, le pouls avait déjà atteint la cuisse, et donc il devrait être lié au temps de transit aortique. En fait, l'accord entre la vitesse de l'onde de pouls doigt-orteil (VOP-do) et la VOP carotide-femorale (VOP-cf) est plutôt bien puisque les études préliminaires ont montré une corrélation acceptable (r² = 0,43; RMSE = 1,3 m / s pour VOP) entre la VOP au pied du doigt (VOP-do) mesuré par le pOpmetre et VOP-cf mesurés par le système SphygmoCor (Alivon et al., 2015). Le mérite de cette étude était de montrer que nous devrions réinvestir la physique de la propagation des ondes pour expliquer cet accord étonnamment bon. Cependant, il a également souligné un manque d'exactitude dans des conditions spécifiques, notamment chez les personnes âgées obèses. Des analyses préliminaires ont suggéré qu'il pourrait être surmonté par des algorithmes et des procédures optimisés. Nous avons émis l'hypothèse que l'évaluation de la rigidité aortique peut être approchée de manière fiable par la VOP-do, car les propriétés mécaniques des artères périphériques sont neutres et ne affectent pas le temps de transit qui est principalement conditionné par la rigidité aortique, en supposant que la différence de temps de transit entre un membre inférieur et un membre supérieur annuleraient la propagation de l'onde de pouls sur les artères périphériques rigides, c'est-à-dire que les temps de transit dans les membres supérieurs et inférieurs sont comparables. En effet, bien que le pOpmetre enregistre l'onde de pouls dans les artères distales, la différence de temps de transit reflète essentiellement la propagation le long de l'aorte thoracique et abdominale. Par conséquent, la VOP-do doit être lié à la rigidité aortique, mesurée par la méthode de référence (VOP-cf). En conséquence, les objectifs de la présente thèse sont divisés en deux parties principales : Partie clinique : en augmentant le nombre et en faisant varier les caractéristiques des sujets pour l'étude de validation du système pOpmetre. (1) Étudier la robustesse de l'algorithme de détection du pied d'onde utilisé par le système pOpmètre. (2) Testez la cohérence de la chaîne de traitement du signal. (3) Vérifiez si la combinaison du meilleur algorithme de détection de pied avec une chaîne de traitement de signal optimisée améliore encore l'accord entre la VOP-do et la VOP-cf, l'étalon-or. (4) Ré-mesurer les sujets de premiers travail avec les algorithmes optimisés. Partie numérique: testez la validité de l'hypothèse physique sur laquelle le système pOpmetre est basé (1) en étendant le modèle 1D existant pour l'arbre artériel avec les circulations main et pied, pour permettre l'évaluation de la VOP-do. (2) Utilisez le modèle de réseau artériel 1D étendu de la circulation systémique pour comparer les performances de la méthode VOP-do avec la méthode de référence. (3) Effectuer une étude de paramètres pour évaluer la validité de différentes méthodes de VOP basées sur les mesures des artères périphériques, en obtenant une meilleure compréhension et validation de leurs principes de travail tout en modifiant les propriétés mécaniques de l'élastique central (aorte, carotide) et / ou artères périphérique / musculaire (brachiale, radiale, fémorale, tibiale, doigt, orteil).
- 22 March 2025
- Published by Elsevier in Acta Astronautica
- Vol. 234, 194-206
Exploring cardiovascular health and alternative biological fluid sampling methods in extreme environments: Lessons from a 12-day Mars analog mission
- 22 March 2025
- Published by Elsevier in Acta Astronautica
- Vol. 234, 194-206
Exploring cardiovascular health and alternative biological fluid sampling methods in extreme environments: Lessons from a 12-day Mars analog mission
- Open Access
- 1 June 2022
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 40 (Suppl 1) , e64
ASSESSMENT OF STIFFNESS OF LARGE TO SMALL ARTERIES IN MULTI-STAGE RENAL DISEASE: A NUMERICAL STUDY
Objective: Arterial stiffness, as assessed via pulse wave velocity (PWV), is a major biomarker for risk assessment in patients with chronic kidney disease. However, the mechanisms responsible for the changes in PWV in the presence of kidney disease are not yet fully elucidated. In the present study, we aimed to investigate the direct effects attributable to biomechanical alterations to the arterial tree caused by renal disease progression on arterial stiffness, independent of any biochemical or compensatory effects. Design and method: Particularly, we used a previously validated one-dimensional (1-D) model of the cardiovascular system to simulate arterial pressure and flow at control with two kidneys (2KDN) and in arterial tree configurations representative of different stages of kidney disease, namely subject with a single functional kidney (1KDN), without any functional kidney (0KDN) and a transplant recipient (TX) with a single functional kidney re-attached to the external iliac artery. We evaluated the respective variations in blood pressure (BP), as well as arterial stiffness of large, medium, and small-sized vessels via carotid-femoral PWV (cfPWV), carotid-radial PWV (crPWV), and radial-digital PWV (rdPWV), respectively. Results: Our results showed that BP was increased in 1KDN and 0KDN, and that systolic BP values were restored in the TX configuration. Furthermore, a rise was reported in all PWVs for all tested configurations. The relative difference in stiffness from control to 0KDN was higher in the case of crPWV (+20 %); approximately twice the difference observed for cfPWV and rdPWV (+11 %). In TX, we observed a restoration of the PWVs to values close to 1KDN. Globally, it was demonstrated that alterations of the outflow boundaries to the renal arteries as occurring in different stages of renal disease lead to changes in blood pressure and central and peripheral PWV in line with previously reported clinical data. Conclusions: Our findings suggest that the PWV variations observed in clinical practice with renal disease progression may be partially attributed to biomechanical alterations of the arterial tree, and their effect on blood pressure.
- 1 June 2022
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 40 (Suppl 1) , e64
Open AccessASSESSMENT OF STIFFNESS OF LARGE TO SMALL ARTERIES IN MULTI-STAGE RENAL DISEASE: A NUMERICAL STUDY
Objective: Arterial stiffness, as assessed via pulse wave velocity (PWV), is a major biomarker for risk assessment in patients with chronic kidney disease. However, the mechanisms responsible for the changes in PWV in the presence of kidney disease are not yet fully elucidated. In the present study, we aimed to investigate the direct effects attributable to biomechanical alterations to the arterial tree caused by renal disease progression on arterial stiffness, independent of any biochemical or compensatory effects. Design and method: Particularly, we used a previously validated one-dimensional (1-D) model of the cardiovascular system to simulate arterial pressure and flow at control with two kidneys (2KDN) and in arterial tree configurations representative of different stages of kidney disease, namely subject with a single functional kidney (1KDN), without any functional kidney (0KDN) and a transplant recipient (TX) with a single functional kidney re-attached to the external iliac artery. We evaluated the respective variations in blood pressure (BP), as well as arterial stiffness of large, medium, and small-sized vessels via carotid-femoral PWV (cfPWV), carotid-radial PWV (crPWV), and radial-digital PWV (rdPWV), respectively. Results: Our results showed that BP was increased in 1KDN and 0KDN, and that systolic BP values were restored in the TX configuration. Furthermore, a rise was reported in all PWVs for all tested configurations. The relative difference in stiffness from control to 0KDN was higher in the case of crPWV (+20 %); approximately twice the difference observed for cfPWV and rdPWV (+11 %). In TX, we observed a restoration of the PWVs to values close to 1KDN. Globally, it was demonstrated that alterations of the outflow boundaries to the renal arteries as occurring in different stages of renal disease lead to changes in blood pressure and central and peripheral PWV in line with previously reported clinical data. Conclusions: Our findings suggest that the PWV variations observed in clinical practice with renal disease progression may be partially attributed to biomechanical alterations of the arterial tree, and their effect on blood pressure.
- Open Access
- 1 June 2022
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 40 (Suppl 1) , e189
THE SYSTOLIC RISE TIME MEASURED WIH PPG TO SCREENING PERIPHERAL ARTERY DISEASE: APPLICATION TO THE POPMETRE
Objective: Screening for Peripheral Artery Disease (PAD) remains a challenge in the prevention and care of patients with arteriosclerosis. The Ankle Brachial Index (ABI) is currently the gold standard. However, ABI is time consuming and requires some expertise to perform which is a limiting factor for global screening. The measurement of the Systolic Rise Time (SRT) of the pulse wave of the lower limb may provide an easier alternative to detect PAD. In a retrospective pilot study, we analyzed the possibility of detecting PAD using the SRT of the toe waveform using the Photo-PlethysmoGraphic signal (PPG). Design and method: We measured 79 subjects (41 patients diagnosed with different stages of PAD and 38 healthy volunteers without known PAD). In each subject, at least one lower limb was assessed with classical ABI. All subjects underwent a PPG assessment on the finger and the toe simultaneously using popmètreâ (Axelife – France). In-house software (JAVA) was used to calculate the SRT of all recorded signals. Results: 146 lower limbs were analyzed including 72 healthy and 74 subjects with PAD. The mean age of the population was 69 ± 12 years with 75% men, 28% diabetics, 47% hypertensive, 49% without clinical PAD defined as stage 0 in this study; 16% in stage 1; 32% in stage 2; 2% in stage 3 and 1% in stage 4 according to the Leriche classification. The SRT cut-off value of 160 ms identifies PAD according to Leriche starting at stage 1 with a sensitivity of 78% vs 73% for ABI < 0.9 and a specificity of 86% vs 87%; a positive predictive value (PPV) of 85% vs 86% and a negative predictive value (NPV) of 79% vs 75%. In addition, the ratio between toe-SRT and finger-SRT cut-off value of 1 identifies PAD with a sensitivity of 76% and a specificity of 74%. Conclusions: SRT measured using a PPG pulse signal of the toe is promising as a facile non-invasive method to diagnose PAD (duration < 14 seconds) and determine PAD stages 1 to 4 with similar specificity and sensitivity as the reference method.
- 1 June 2022
- Published by Wolters Kluwer Health in Journal Of Hypertension
- Vol. 40 (Suppl 1) , e189
Open AccessTHE SYSTOLIC RISE TIME MEASURED WIH PPG TO SCREENING PERIPHERAL ARTERY DISEASE: APPLICATION TO THE POPMETRE
Objective: Screening for Peripheral Artery Disease (PAD) remains a challenge in the prevention and care of patients with arteriosclerosis. The Ankle Brachial Index (ABI) is currently the gold standard. However, ABI is time consuming and requires some expertise to perform which is a limiting factor for global screening. The measurement of the Systolic Rise Time (SRT) of the pulse wave of the lower limb may provide an easier alternative to detect PAD. In a retrospective pilot study, we analyzed the possibility of detecting PAD using the SRT of the toe waveform using the Photo-PlethysmoGraphic signal (PPG). Design and method: We measured 79 subjects (41 patients diagnosed with different stages of PAD and 38 healthy volunteers without known PAD). In each subject, at least one lower limb was assessed with classical ABI. All subjects underwent a PPG assessment on the finger and the toe simultaneously using popmètreâ (Axelife – France). In-house software (JAVA) was used to calculate the SRT of all recorded signals. Results: 146 lower limbs were analyzed including 72 healthy and 74 subjects with PAD. The mean age of the population was 69 ± 12 years with 75% men, 28% diabetics, 47% hypertensive, 49% without clinical PAD defined as stage 0 in this study; 16% in stage 1; 32% in stage 2; 2% in stage 3 and 1% in stage 4 according to the Leriche classification. The SRT cut-off value of 160 ms identifies PAD according to Leriche starting at stage 1 with a sensitivity of 78% vs 73% for ABI < 0.9 and a specificity of 86% vs 87%; a positive predictive value (PPV) of 85% vs 86% and a negative predictive value (NPV) of 79% vs 75%. In addition, the ratio between toe-SRT and finger-SRT cut-off value of 1 identifies PAD with a sensitivity of 76% and a specificity of 74%. Conclusions: SRT measured using a PPG pulse signal of the toe is promising as a facile non-invasive method to diagnose PAD (duration < 14 seconds) and determine PAD stages 1 to 4 with similar specificity and sensitivity as the reference method.
- Open Access
- 28 April 2022
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 2 (3) , oeac032
Assessment of the systolic rise time by photoplethysmography in peripheral arterial diseases: a comparative study with ultrasound Doppler
Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs). There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique. This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.
- 28 April 2022
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 2 (3) , oeac032
Open AccessAssessment of the systolic rise time by photoplethysmography in peripheral arterial diseases: a comparative study with ultrasound Doppler
Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs). There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique. This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.
- Open Access
- 15 December 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 774056
Modulation of Arterial Stiffness Gradient by Acute Administration of Nitroglycerin
Background: Physiologically, the aorta is less stiff than peripheral conductive arteries, creating an arterial stiffness gradient, protecting microcirculation from high pulsatile pressure. However, the pharmacological manipulation of arterial stiffness gradient has not been thoroughly investigated. We hypothesized that acute administration of nitroglycerin (NTG) may alter the arterial stiffness gradient through a more significant effect on the regional stiffness of medium-sized muscular arteries, as measured by pulse wave velocity (PWV). The aim of this study was to examine the differential impact of NTG on regional stiffness, and arterial stiffness gradient as measured by the aortic-brachial PWV ratio (AB-PWV ratio) and aortic-femoral PWV ratio (AF-PWV ratio).Methods: In 93 subjects (age: 61 years, men: 67%, chronic kidney disease [CKD]: 41%), aortic, brachial, and femoral stiffnesses were determined by cf-PWV, carotid-radial (cr-PWV), and femoral-dorsalis pedis artery (fp-PWV) PWVs, respectively. The measurements were repeated 5 min after the sublingual administration of NTG (0.4 mg). The AB-PWV and AF-PWV ratios were obtained by dividing cf-PWV by cr-PWV or fp-PWV, respectively. The central pulse wave profile was determined by radial artery tonometry through the generalized transfer function.Results: At baseline, cf-PWV, cr-PWV, and fp-PWV were 12.12 ± 3.36, 9.51 ± 1.81, and 9.71 ± 1.89 m/s, respectively. After the administration of NTG, there was a significant reduction in cr-PWV of 0.86 ± 1.27 m/s (p < 0.001) and fp-PWV of 1.12 ± 1.74 m/s (p < 0.001), without any significant changes in cf-PWV (p = 0.928), leading to a significant increase in the AB-PWV ratio (1.30 ± 0.39 vs. 1.42 ± 0.46; p = 0.001) and AF-PWV ratio (1.38 ± 0.47 vs. 1.56 ± 0.53; p = 0.001). There was a significant correlation between changes in the AF-PWV ratio and changes in the timing of wave reflection (r = 0.289; p = 0.042) and the amplitude of the heart rate-adjusted augmented pressure (r = − 0.467; p < 0.001).Conclusion: This study shows that acute administration of NTG reduces PWV of muscular arteries (brachial and femoral) without modifying aortic PWV. This results in an unfavorable profile of AB-PWV and AF-PWV ratios, which could lead to higher pulse pressure transmission into the microcirculation.
- 15 December 2021
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 774056
Open AccessModulation of Arterial Stiffness Gradient by Acute Administration of Nitroglycerin
Background: Physiologically, the aorta is less stiff than peripheral conductive arteries, creating an arterial stiffness gradient, protecting microcirculation from high pulsatile pressure. However, the pharmacological manipulation of arterial stiffness gradient has not been thoroughly investigated. We hypothesized that acute administration of nitroglycerin (NTG) may alter the arterial stiffness gradient through a more significant effect on the regional stiffness of medium-sized muscular arteries, as measured by pulse wave velocity (PWV). The aim of this study was to examine the differential impact of NTG on regional stiffness, and arterial stiffness gradient as measured by the aortic-brachial PWV ratio (AB-PWV ratio) and aortic-femoral PWV ratio (AF-PWV ratio).Methods: In 93 subjects (age: 61 years, men: 67%, chronic kidney disease [CKD]: 41%), aortic, brachial, and femoral stiffnesses were determined by cf-PWV, carotid-radial (cr-PWV), and femoral-dorsalis pedis artery (fp-PWV) PWVs, respectively. The measurements were repeated 5 min after the sublingual administration of NTG (0.4 mg). The AB-PWV and AF-PWV ratios were obtained by dividing cf-PWV by cr-PWV or fp-PWV, respectively. The central pulse wave profile was determined by radial artery tonometry through the generalized transfer function.Results: At baseline, cf-PWV, cr-PWV, and fp-PWV were 12.12 ± 3.36, 9.51 ± 1.81, and 9.71 ± 1.89 m/s, respectively. After the administration of NTG, there was a significant reduction in cr-PWV of 0.86 ± 1.27 m/s (p < 0.001) and fp-PWV of 1.12 ± 1.74 m/s (p < 0.001), without any significant changes in cf-PWV (p = 0.928), leading to a significant increase in the AB-PWV ratio (1.30 ± 0.39 vs. 1.42 ± 0.46; p = 0.001) and AF-PWV ratio (1.38 ± 0.47 vs. 1.56 ± 0.53; p = 0.001). There was a significant correlation between changes in the AF-PWV ratio and changes in the timing of wave reflection (r = 0.289; p = 0.042) and the amplitude of the heart rate-adjusted augmented pressure (r = − 0.467; p < 0.001).Conclusion: This study shows that acute administration of NTG reduces PWV of muscular arteries (brachial and femoral) without modifying aortic PWV. This results in an unfavorable profile of AB-PWV and AF-PWV ratios, which could lead to higher pulse pressure transmission into the microcirculation.
- 1 April 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (4) , H1361-H1369
Radial-digital pulse wave velocity: a noninvasive method for assessing stiffness of small conduit arteries
Pulse wave velocity (PWV) is used to evaluate regional stiffness of large and medium-sized arteries. Here, we examine the feasibility and reliability of radial-digital PWV (RD-PWV) as a measure of regional stiffness of small conduit arteries and its response to changes in hydrostatic pressure. In 29 healthy subjects, we used Complior Analyse piezoelectric probes to record arterial pulse wave at the radial artery and the tip of the index. We determined transit time by second-derivative and intersecting tangents using the device-embedded algorithms and in-house MATLAB-based analyses of only reliable waves and by numerical simulation using a one-dimensional (1-D) arterial tree model coupled with a heart model. Second-derivative RD-PWV was 4.68 ± 1.18, 4.69 ± 1.21, and 4.32 ± 1.19 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersecting-tangent RD-PWV was 4.73 ± 1.20, 4.45 ± 1.08, and 4.50 ± 0.84 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersession coefficients of variation were 7.0% ± 4.9% and 3.2% ± 1.9% (P = 0.04) for device-embedded and MATLAB-based second-derivative algorithms, respectively. In 15 subjects, we examined the response of RD-PWV to changes in local hydrostatic pressure by vertical displacement of the hand. For an increase of 10 mmHg in local hydrostatic pressure, RD-PWV increased by 0.28 m/s (95% confidence interval: 0.16–0.40; P < 0.001). This study shows that RD-PWV can be used for the noninvasive assessment of regional stiffness of small conduit arteries. This finding allows for an integrated approach for assessing arterial stiffness gradient from the aorta to medium-sized arteries and now to small conduit arteries. NEW & NOTEWORTHY The interaction between the stiffness of various arterial segments is important in understanding the behavior of pressure and flow waves along the arterial tree. In this article, we provide a novel and noninvasive method of assessing the regional stiffness of small conduit arteries using the same piezoelectric sensors used for determination of pulse wave velocity over large- and medium-sized arteries. This development allows for an integrated approach for studying arterial stiffness gradient.
- 1 April 2021
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 320 (4) , H1361-H1369
Radial-digital pulse wave velocity: a noninvasive method for assessing stiffness of small conduit arteries
Pulse wave velocity (PWV) is used to evaluate regional stiffness of large and medium-sized arteries. Here, we examine the feasibility and reliability of radial-digital PWV (RD-PWV) as a measure of regional stiffness of small conduit arteries and its response to changes in hydrostatic pressure. In 29 healthy subjects, we used Complior Analyse piezoelectric probes to record arterial pulse wave at the radial artery and the tip of the index. We determined transit time by second-derivative and intersecting tangents using the device-embedded algorithms and in-house MATLAB-based analyses of only reliable waves and by numerical simulation using a one-dimensional (1-D) arterial tree model coupled with a heart model. Second-derivative RD-PWV was 4.68 ± 1.18, 4.69 ± 1.21, and 4.32 ± 1.19 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersecting-tangent RD-PWV was 4.73 ± 1.20, 4.45 ± 1.08, and 4.50 ± 0.84 m/s for device-embedded, MATLAB-based, and numerical simulation analyses, respectively. Intersession coefficients of variation were 7.0% ± 4.9% and 3.2% ± 1.9% (P = 0.04) for device-embedded and MATLAB-based second-derivative algorithms, respectively. In 15 subjects, we examined the response of RD-PWV to changes in local hydrostatic pressure by vertical displacement of the hand. For an increase of 10 mmHg in local hydrostatic pressure, RD-PWV increased by 0.28 m/s (95% confidence interval: 0.16–0.40; P < 0.001). This study shows that RD-PWV can be used for the noninvasive assessment of regional stiffness of small conduit arteries. This finding allows for an integrated approach for assessing arterial stiffness gradient from the aorta to medium-sized arteries and now to small conduit arteries. NEW & NOTEWORTHY The interaction between the stiffness of various arterial segments is important in understanding the behavior of pressure and flow waves along the arterial tree. In this article, we provide a novel and noninvasive method of assessing the regional stiffness of small conduit arteries using the same piezoelectric sensors used for determination of pulse wave velocity over large- and medium-sized arteries. This development allows for an integrated approach for studying arterial stiffness gradient.
- Open Access
- 31 December 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (S1) , S48
P.25 Radial-Digital Pulse Wave Velocity: A Non-Invasive Method for Assessing Stiffness of Peripheral Small Arteries
Pulse wave velocity (PWV) has been used to evaluate arterial stiffness of large arteries. Here, we examine the feasibility of radialdigital PWV (RD-PWV) as a measure of stiffness of smaller arteries, and its response to changes in local mean arterial pressure. In 29 healthy subjects, we used Complior probes to record arterial pulse wave at radial artery and tip of the index. To determine transit time, we used both second derivative and intersecting tangents of the entire recordings using the device-embedded algorithms, in house Matlab analyses of only reliable waves, and by numerical simulation using arterial tree model. In 15 subjects, we examine the response of RD-PWV to changes in local MAP by vertical displacement of the hand above and below the mid-axillary line. Using second derivative, RD-PWV were 4.68 ± 1.18, 4.69 ± 1.21, 4.32 ± 1.19 m/s respectively for deviceembedded, Matlab-based and numerical simulation analyses, respectively. Using intersecting tangents RD-PWV were 4.73 ± 1.20, 4.45 ± 1.08, 4.50 ± 0.84 m/s, respectively for device-embedded, Matlab-based and numerical simulation analyses, respectively. The strongest correlation (r = 0.92) was seen between device-embedded and Matlab-based second derivatives. The intersession coefficients of variation were 7.0 ± 4.9% and 3.2 ± 1.9% (p = 0.04) for device-embedded and Matlab-based second derivative algorithms. We estimated that each increase of 10 mm Hg in local MAP by vertical displacement of the hand resulted in an increase in RD-PWV of 0.28 m/s. This study shows that RD-PWV can be used for the non-invasive assessment of stiffness of small-sized arteries.
- 31 December 2020
- Published by Springer Nature in Artery Research
- Vol. 26 (S1) , S48
Open AccessP.25 Radial-Digital Pulse Wave Velocity: A Non-Invasive Method for Assessing Stiffness of Peripheral Small Arteries
Pulse wave velocity (PWV) has been used to evaluate arterial stiffness of large arteries. Here, we examine the feasibility of radialdigital PWV (RD-PWV) as a measure of stiffness of smaller arteries, and its response to changes in local mean arterial pressure. In 29 healthy subjects, we used Complior probes to record arterial pulse wave at radial artery and tip of the index. To determine transit time, we used both second derivative and intersecting tangents of the entire recordings using the device-embedded algorithms, in house Matlab analyses of only reliable waves, and by numerical simulation using arterial tree model. In 15 subjects, we examine the response of RD-PWV to changes in local MAP by vertical displacement of the hand above and below the mid-axillary line. Using second derivative, RD-PWV were 4.68 ± 1.18, 4.69 ± 1.21, 4.32 ± 1.19 m/s respectively for deviceembedded, Matlab-based and numerical simulation analyses, respectively. Using intersecting tangents RD-PWV were 4.73 ± 1.20, 4.45 ± 1.08, 4.50 ± 0.84 m/s, respectively for device-embedded, Matlab-based and numerical simulation analyses, respectively. The strongest correlation (r = 0.92) was seen between device-embedded and Matlab-based second derivatives. The intersession coefficients of variation were 7.0 ± 4.9% and 3.2 ± 1.9% (p = 0.04) for device-embedded and Matlab-based second derivative algorithms. We estimated that each increase of 10 mm Hg in local MAP by vertical displacement of the hand resulted in an increase in RD-PWV of 0.28 m/s. This study shows that RD-PWV can be used for the non-invasive assessment of stiffness of small-sized arteries.
- 1 July 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (7) , 078002
Reply to Comment on ‘Numerical assessment and comparison of pulse wave velocity methods aiming at measuring aortic stiffness’
Dear editor, dear referees, please find below the point to point responses to the review of our reply on comments (RE: PMEA-102395) entitled: NUMERICAL ASSESSMENT AND COMPARISON OF PULSE WAVE VELOCITY METHODS AIMING AT MEASURING AORTIC STIFFNESS. We addressed all the questions and tried to modify the text each time it was possible. We hope that our answers will satisfy the referees.
- 1 July 2018
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (7) , 078002
Reply to Comment on ‘Numerical assessment and comparison of pulse wave velocity methods aiming at measuring aortic stiffness’
Dear editor, dear referees, please find below the point to point responses to the review of our reply on comments (RE: PMEA-102395) entitled: NUMERICAL ASSESSMENT AND COMPARISON OF PULSE WAVE VELOCITY METHODS AIMING AT MEASURING AORTIC STIFFNESS. We addressed all the questions and tried to modify the text each time it was possible. We hope that our answers will satisfy the referees.