Sukhjeet Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sukhjeet Singh has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Amrinder Singh Minhas
5 shared publicationsNavin Kumar
Indian Institute of Technology
4 shared publicationsP.K. Kankar
3 shared publicationsGurpreet Singh
Guru Nanak Dev University
2 shared publications- Navin Kumar
Indian Institute of Technology [IIT] Ropar, Rupnagar, India
2 shared publications - Pavan Kumar Kankar
System Dynamics Lab, Department of Mechanical Engineering, Indian Institute of Technology Indore, Indore, India
2 shared publications
Latest Publications
- 1 February 2021
- Published by Elsevier in Measurement
- Vol. 169
Integrated approach based on flexible analytical wavelet transform and permutation entropy for fault detection in rotary machines
- 1 February 2021
- Published by Elsevier in Measurement
- Vol. 169
Integrated approach based on flexible analytical wavelet transform and permutation entropy for fault detection in rotary machines
- 1 January 2021
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 147
Bearing fault detection and recognition methodology based on weighted multiscale entropy approach
- 1 January 2021
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 147
Bearing fault detection and recognition methodology based on weighted multiscale entropy approach
- 1 December 2020
- Published by Elsevier in Asian Journal of Psychiatry
- Vol. 54, 102280
Psychological fear and anxiety caused by COVID-19: Insights from Twitter analytics
- 1 December 2020
- Published by Elsevier in Asian Journal of Psychiatry
- Vol. 54, 102280
Psychological fear and anxiety caused by COVID-19: Insights from Twitter analytics
- Open Access
- 3 November 2020
- Published by Scientific Scholar in Journal of Cardiac Critical Care TSS
- Vol. 4  (02) , 132-135
Technical Details of Aortic Valve Replacement using Carpentier–Edwards PERIMOUNT Magna Ease Aortic Bioprosthesis in a Sexagenarian Patient with Severe Calcific Aortic Stenosis: A Video Presentation
The current guidelines of the American Heart Association (AHA), American College of Cardiology (ACC) from 2014, and the European Society of Cardiology (ESC) from 2012 uniformly recommend mechanical aortic valve replacement in patients under 60 years of age and biologic aortic valve replacement in patients over 70 years of age.[1] [2] The recommendations are conflicting for patients between 60 and 70 years of age. The ESC guidelines recommend biologic prosthesis from the age of 65 years onward, whereas the newer AHA/ACC guidelines only recommend biological valves starting 70 years of age. Over the past 20 years, there is a shift away from a clear-cut age limit toward patient’s wish and lifestyle considerations.[3] The number of surgical aortic valve replacements using a bioprosthesis is increasing according to the annual surveys of thoracic surgery in 2013 and 2014 by the Japanese Association for Thoracic Surgery, which states that bioprostheses are used in three-quarters of all aortic valve replacements procedures.[4] In addition, the age limit for implantation of an aortic bioprosthesis is continuously being shifted down with bioprostheses used for aortic valve replacements in 60% of sexagenarian patients and 90% of septuagenarian or octogenarian patients.[3] [4] [5] [6] This may be related to the enhanced durability of new-generation bioprostheses, improved outcomes of redo valve replacement surgery, or the development of valve-in-valve (ViV) transcatheter aortic valve implantation.[3] [4] [5] [6] Randomized trials comparing biological and mechanical valve replacements are scanty. In 2009, Stassano and associates randomized 310 patients between 55 and 70 years of age into a mechanical and a biological prosthesis group to undergo aortic valve replacement. At a mean follow-up of 4 years, they found similar mortality and other adverse prosthesis-related events, namely, thromboembolic complications, bleeding, endocarditis, and structural valvular deterioration in the two group of patients.[7] In 2008, Brown and associates analyzed outcome after aortic valve replacement with mechanical versus biological prosthesis in patients aged between 50 and 70 years at operation. Freedom from reoperation was 98% for mechanical valve and 91% for bioprosthesis (p = 0.06). Rehospitalization for hemorrhagic events occurred in 15% of patients with mechanical valves and 7% of patients with bioprosthesis (p = 0.001). The 5- and 10-year unadjusted survivals were 87% and 68% for mechanical valves and 72% and 50% for bioprosthesis, respectively.[8] The reported incidence of survival following mechanical mitral valve replacement in the published literature at 10, 20, and 30 years was 61 to 75%, 36.5 to 39% and 22.6%, respectively.[9] [10] [11] [12] [13] [14] The Carpentier–Edwards pericardial prosthesis commercially available since 1980 is the bioprosthesis, which is the most used worldwide. As a second-generation pericardial bioprosthesis, the Carpentier–Edwards pericardial valve was designed to minimize structural valvular deterioration, which plagued the first-generation prosthesis while retaining the hemodynamic superiority conferred by pericardial valve substitutes.[14] [15] [16] [17] Published literature documents excellent long-term outcomes with the Carpentier–Edwards pericardial valve ([Table 1]).[15] [18] [19] [20] [21] [22] The PERIMOUNT Magna Ease which is a further development of the PERIMOUNT Magna prosthesis (Edwards Lifesciences, Irvine, CA, USA) belongs to the latest generation of aortic valve prostheses. The manufacturers points the following advantages: lower profile, contoured and complaint sewing rings, and larger effective orifice areas, which would result in easier insertion and higher coronary ostial clearance; further, it lowers transprosthetic gradients and avoids prosthesis-patient mismatch; also, lower gradients together with an anticalcification technology prevents early structural valve deterioration.[23] [24] [25] Although the Carpentier–Edwards PERIMOUNT Magna Ease valve is a bioprosthesis with documented excellent hemodynamics and other advantages as stated above, the valve has a gap between the cobalt-chromium-nickel alloy stent and silicone sewing ring. This gap, which is widest just below each of the three commissural struts, lacks silicone and leaves the two-layer polytetrafluoroethylene fabric unprotected. The passage of a needle through this weak area may result in fabric tear, resulting in a true cuff leakage and not the usual paravalvular leakage. To date, there are four case reports of cuff leakage in the literature diagnosed by transesophageal echocardiography. Three patients with cuff leakage were managed conservatively, and in one patient, it was sutured using polypropylene suture.[26] [27] [28] [29] Pledgeted mattress sutures like we have used in our case in this manuscript have been advocated by other authors to prevent this complication.[29] We report herein a 61-year-old male patient (body surface area 1.7 m2) diagnosed with severe calcific aortic stenosis, with a peak systolic left ventricle-to-aortic gradient of 110 mm Hg and normal coronaries undergoing aortic valve replacement using a 21 mm Carpentier–Edwards PERIMOUNT Magna Ease aortic prosthesis under moderately hypothermic cardiopulmonary bypass, St. Thomas (II)-based cold blood cardioplegia and iced normal saline. Postoperative recovery was uneventful. Publication Date: 03 November 2020 (online) © 2020. Official Publication of The Simulation Society TSS, accredited by International Society of Cardiovascular Ultrasound ISCU. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/.) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 3 November 2020
- Published by Scientific Scholar in Journal of Cardiac Critical Care TSS
- Vol. 4  (02) , 132-135
Open AccessTechnical Details of Aortic Valve Replacement using Carpentier–Edwards PERIMOUNT Magna Ease Aortic Bioprosthesis in a Sexagenarian Patient with Severe Calcific Aortic Stenosis: A Video Presentation
The current guidelines of the American Heart Association (AHA), American College of Cardiology (ACC) from 2014, and the European Society of Cardiology (ESC) from 2012 uniformly recommend mechanical aortic valve replacement in patients under 60 years of age and biologic aortic valve replacement in patients over 70 years of age.[1] [2] The recommendations are conflicting for patients between 60 and 70 years of age. The ESC guidelines recommend biologic prosthesis from the age of 65 years onward, whereas the newer AHA/ACC guidelines only recommend biological valves starting 70 years of age. Over the past 20 years, there is a shift away from a clear-cut age limit toward patient’s wish and lifestyle considerations.[3] The number of surgical aortic valve replacements using a bioprosthesis is increasing according to the annual surveys of thoracic surgery in 2013 and 2014 by the Japanese Association for Thoracic Surgery, which states that bioprostheses are used in three-quarters of all aortic valve replacements procedures.[4] In addition, the age limit for implantation of an aortic bioprosthesis is continuously being shifted down with bioprostheses used for aortic valve replacements in 60% of sexagenarian patients and 90% of septuagenarian or octogenarian patients.[3] [4] [5] [6] This may be related to the enhanced durability of new-generation bioprostheses, improved outcomes of redo valve replacement surgery, or the development of valve-in-valve (ViV) transcatheter aortic valve implantation.[3] [4] [5] [6] Randomized trials comparing biological and mechanical valve replacements are scanty. In 2009, Stassano and associates randomized 310 patients between 55 and 70 years of age into a mechanical and a biological prosthesis group to undergo aortic valve replacement. At a mean follow-up of 4 years, they found similar mortality and other adverse prosthesis-related events, namely, thromboembolic complications, bleeding, endocarditis, and structural valvular deterioration in the two group of patients.[7] In 2008, Brown and associates analyzed outcome after aortic valve replacement with mechanical versus biological prosthesis in patients aged between 50 and 70 years at operation. Freedom from reoperation was 98% for mechanical valve and 91% for bioprosthesis (p = 0.06). Rehospitalization for hemorrhagic events occurred in 15% of patients with mechanical valves and 7% of patients with bioprosthesis (p = 0.001). The 5- and 10-year unadjusted survivals were 87% and 68% for mechanical valves and 72% and 50% for bioprosthesis, respectively.[8] The reported incidence of survival following mechanical mitral valve replacement in the published literature at 10, 20, and 30 years was 61 to 75%, 36.5 to 39% and 22.6%, respectively.[9] [10] [11] [12] [13] [14] The Carpentier–Edwards pericardial prosthesis commercially available since 1980 is the bioprosthesis, which is the most used worldwide. As a second-generation pericardial bioprosthesis, the Carpentier–Edwards pericardial valve was designed to minimize structural valvular deterioration, which plagued the first-generation prosthesis while retaining the hemodynamic superiority conferred by pericardial valve substitutes.[14] [15] [16] [17] Published literature documents excellent long-term outcomes with the Carpentier–Edwards pericardial valve ([Table 1]).[15] [18] [19] [20] [21] [22] The PERIMOUNT Magna Ease which is a further development of the PERIMOUNT Magna prosthesis (Edwards Lifesciences, Irvine, CA, USA) belongs to the latest generation of aortic valve prostheses. The manufacturers points the following advantages: lower profile, contoured and complaint sewing rings, and larger effective orifice areas, which would result in easier insertion and higher coronary ostial clearance; further, it lowers transprosthetic gradients and avoids prosthesis-patient mismatch; also, lower gradients together with an anticalcification technology prevents early structural valve deterioration.[23] [24] [25] Although the Carpentier–Edwards PERIMOUNT Magna Ease valve is a bioprosthesis with documented excellent hemodynamics and other advantages as stated above, the valve has a gap between the cobalt-chromium-nickel alloy stent and silicone sewing ring. This gap, which is widest just below each of the three commissural struts, lacks silicone and leaves the two-layer polytetrafluoroethylene fabric unprotected. The passage of a needle through this weak area may result in fabric tear, resulting in a true cuff leakage and not the usual paravalvular leakage. To date, there are four case reports of cuff leakage in the literature diagnosed by transesophageal echocardiography. Three patients with cuff leakage were managed conservatively, and in one patient, it was sutured using polypropylene suture.[26] [27] [28] [29] Pledgeted mattress sutures like we have used in our case in this manuscript have been advocated by other authors to prevent this complication.[29] We report herein a 61-year-old male patient (body surface area 1.7 m2) diagnosed with severe calcific aortic stenosis, with a peak systolic left ventricle-to-aortic gradient of 110 mm Hg and normal coronaries undergoing aortic valve replacement using a 21 mm Carpentier–Edwards PERIMOUNT Magna Ease aortic prosthesis under moderately hypothermic cardiopulmonary bypass, St. Thomas (II)-based cold blood cardioplegia and iced normal saline. Postoperative recovery was uneventful. Publication Date: 03 November 2020 (online) © 2020. Official Publication of The Simulation Society TSS, accredited by International Society of Cardiovascular Ultrasound ISCU. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/.) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- Open Access
- 1 November 2020
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 20  (6) , 286-289
Long QT syndrome with AV Wenckebaching & bundle branch block in a neonate
- 1 November 2020
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 20  (6) , 286-289
Open AccessLong QT syndrome with AV Wenckebaching & bundle branch block in a neonate
- 30 October 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 235  (2) , 167-184
Spectral features based convolutional neural network for accurate and prompt identification of schizophrenic patients
Schizophrenia is a fatal mental disorder, which affects millions of people globally by the disturbance in their thinking, feeling and behaviour. In the age of the internet of things assisted with cloud computing and machine learning techniques, the computer-aided diagnosis of schizophrenia is essentially required to provide its patients with an opportunity to own a better quality of life. In this context, the present paper proposes a spectral features based convolutional neural network (CNN) model for accurate identification of schizophrenic patients using spectral analysis of multichannel EEG signals in real-time. This model processes acquired EEG signals with filtering, segmentation and conversion into frequency domain. Then, given frequency domain segments are divided into six distinct spectral bands like delta, theta-1, theta-2, alpha, beta and gamma. The spectral features including mean spectral amplitude, spectral power and Hjorth descriptors (Activity, Mobility and Complexity) are extracted from each band. These features are independently fed to the proposed spectral features-based CNN and long short-term memory network (LSTM) models for classification. This work also makes use of raw time-domain and frequency-domain EEG segments for classification using temporal CNN and spectral CNN models of same architectures respectively. The overall analysis of simulation results of all models exhibits that the proposed spectral features based CNN model is an efficient technique for accurate and prompt identification of schizophrenic patients among healthy individuals with average classification accuracies of 94.08% and 98.56% for two different datasets with optimally small classification time.
- 30 October 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 235  (2) , 167-184
Spectral features based convolutional neural network for accurate and prompt identification of schizophrenic patients
Schizophrenia is a fatal mental disorder, which affects millions of people globally by the disturbance in their thinking, feeling and behaviour. In the age of the internet of things assisted with cloud computing and machine learning techniques, the computer-aided diagnosis of schizophrenia is essentially required to provide its patients with an opportunity to own a better quality of life. In this context, the present paper proposes a spectral features based convolutional neural network (CNN) model for accurate identification of schizophrenic patients using spectral analysis of multichannel EEG signals in real-time. This model processes acquired EEG signals with filtering, segmentation and conversion into frequency domain. Then, given frequency domain segments are divided into six distinct spectral bands like delta, theta-1, theta-2, alpha, beta and gamma. The spectral features including mean spectral amplitude, spectral power and Hjorth descriptors (Activity, Mobility and Complexity) are extracted from each band. These features are independently fed to the proposed spectral features-based CNN and long short-term memory network (LSTM) models for classification. This work also makes use of raw time-domain and frequency-domain EEG segments for classification using temporal CNN and spectral CNN models of same architectures respectively. The overall analysis of simulation results of all models exhibits that the proposed spectral features based CNN model is an efficient technique for accurate and prompt identification of schizophrenic patients among healthy individuals with average classification accuracies of 94.08% and 98.56% for two different datasets with optimally small classification time.
- Open Access
- 20 October 2020
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 42  (11) , 1-21
Improvement in classification accuracy and computational speed in bearing fault diagnosis using multiscale fuzzy entropy
- 20 October 2020
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 42  (11) , 1-21
Open AccessImprovement in classification accuracy and computational speed in bearing fault diagnosis using multiscale fuzzy entropy
- 9 July 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234  (10) , 1083-1093
Comparing the capabilities of transfer learning models to detect skin lesion in humans
Effective diagnosis of skin tumours mainly relies on the analysis of the characteristics of the lesion. Automatic detection of malignant skin lesion has become a mandatory task to reduce the risk of human deaths and increase their survival. This article proposes a study of skin lesion classification using transfer learning approach. The transfer learning model uses four different state-of-the-art architectures, namely Inception v3, Residual Networks (ResNet 50), Dense Convolutional Networks (DenseNet 201) and Inception Residual Networks (Inception ResNet v2). These models are trained under the dataset comprising seven different classes of skin lesions. The skin lesion images are pre-processed using image quantization, grayscaling and the Wiener filter before final training step. These models are compared for performance evaluation on different metrics. The present study shows the efficacy of the methodology for automated classification of lesion images.
- 9 July 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 234  (10) , 1083-1093
Comparing the capabilities of transfer learning models to detect skin lesion in humans
Effective diagnosis of skin tumours mainly relies on the analysis of the characteristics of the lesion. Automatic detection of malignant skin lesion has become a mandatory task to reduce the risk of human deaths and increase their survival. This article proposes a study of skin lesion classification using transfer learning approach. The transfer learning model uses four different state-of-the-art architectures, namely Inception v3, Residual Networks (ResNet 50), Dense Convolutional Networks (DenseNet 201) and Inception Residual Networks (Inception ResNet v2). These models are trained under the dataset comprising seven different classes of skin lesions. The skin lesion images are pre-processed using image quantization, grayscaling and the Wiener filter before final training step. These models are compared for performance evaluation on different metrics. The present study shows the efficacy of the methodology for automated classification of lesion images.
- 3 June 2020
- Published by Springer Nature
- p. 629-637
Fault Detection in Complex Mechanical Systems Using Wavelet Transforms and Autoregressive Coefficients
- 3 June 2020
- Published by Springer Nature
- p. 629-637
Fault Detection in Complex Mechanical Systems Using Wavelet Transforms and Autoregressive Coefficients
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 841  (1) , 012006
Fault Diagnosis of Ball Bearing Using Hilbert Huang Transform and LASSO Feature Ranking Technique
Bearings are one of the crucial components of any machine having rotary parts. They are employed to support and ensure smooth operations of the shafts in the rotary machinery. Therefore, any fault in the bearings can lead to a decline in the level of production and equipment. For this reason, it is important to monitor the bearing health. This paper presents a signal analysis technique for machine health monitoring using the Hilbert-Huang Transform (HHT). HHT is a time domain approach which extracts instantaneous frequency data from a signal by decomposing the signal into Intrinsic Mode Functions (IMF) using the Empirical Mode Decomposition (EMD). The Least Absolute Shrinkage and Selection Operator (LASSO) is used as feature ranking method which is used to improve the prediction accuracy by reducing input data to machine learning model by aiding to select only a subset of the feature vector rather than using all of the features. In the present work, training and tenfold cross-validation accuracy or two classifiers have been compared. The comparative analysis presented in this paper reveals that the utilization of LASSO as a feature ranking method shows a substantial decrease in the data to be handled and improving the diagnosis accuracy.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 841  (1) , 012006
Open AccessFault Diagnosis of Ball Bearing Using Hilbert Huang Transform and LASSO Feature Ranking Technique
Bearings are one of the crucial components of any machine having rotary parts. They are employed to support and ensure smooth operations of the shafts in the rotary machinery. Therefore, any fault in the bearings can lead to a decline in the level of production and equipment. For this reason, it is important to monitor the bearing health. This paper presents a signal analysis technique for machine health monitoring using the Hilbert-Huang Transform (HHT). HHT is a time domain approach which extracts instantaneous frequency data from a signal by decomposing the signal into Intrinsic Mode Functions (IMF) using the Empirical Mode Decomposition (EMD). The Least Absolute Shrinkage and Selection Operator (LASSO) is used as feature ranking method which is used to improve the prediction accuracy by reducing input data to machine learning model by aiding to select only a subset of the feature vector rather than using all of the features. In the present work, training and tenfold cross-validation accuracy or two classifiers have been compared. The comparative analysis presented in this paper reveals that the utilization of LASSO as a feature ranking method shows a substantial decrease in the data to be handled and improving the diagnosis accuracy.