Yan Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yan Shen has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jin-Ming Ge
Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China
5 shared publications - Fangwei Duan
State Grid Liaoning Electric Power Research Institute, Shenyang 110006, China
2 shared publications Wei Fan
State Grid Liaoning Electric Power Research Institute Shenyang China
2 shared publications- Wen-Bin Yu
Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150001, China
2 shared publications Wenbin Yu
Department of Electrical Engineering, Harbin Institute of Technology, Harbin 150080, China
2 shared publications- Yue Han
State Grid Liaoning Electric Power Research Institute, Shenyang 110006, China
2 shared publications
Latest Publications
- Open Access
Study on the Application of Optical Current Sensor for Lightning Current Measurement of Transmission Line
Accurate and reliable lightning current data are the basis of lightning protection design. To measure lightning current data at different measurement locations in a transmission system, the limitations of traditional lightning current sensors are analyzed, and optical current sensing technology is adopted, which has the advantages of no magnetic saturation and no bandwidth limitation. Compared with traditional application environments, the sensing technology is used in special environments in transmission systems. This paper analyzes the influence of environmental factors on sensors, and combines the extreme environmental requirements, such as temperature and insulation requirements, to study the sensor. Starting from the sensitivity, the sensing characteristics of the sensor are analyzed. The sensor is designed according to three aspects: sensing material selection, spatial measuring position, and sensing material size optimization, such that it can satisfy the different measurement requirements of towers, overhead ground wires, and transmission lines, respectively. The experiments indicate that the developed sensors can meet the measurement sensitivity requirements of different types of lightning strikes. The experimental results of sensors exhibit a reasonable amplitude measurement accuracy, linearity, and waveform measurement capability. These results provide important theoretical and experimental bases for the application of optical current sensing technology to the measurement of the lightning current of transmission systems.
Open AccessStudy on the Application of Optical Current Sensor for Lightning Current Measurement of Transmission Line
Accurate and reliable lightning current data are the basis of lightning protection design. To measure lightning current data at different measurement locations in a transmission system, the limitations of traditional lightning current sensors are analyzed, and optical current sensing technology is adopted, which has the advantages of no magnetic saturation and no bandwidth limitation. Compared with traditional application environments, the sensing technology is used in special environments in transmission systems. This paper analyzes the influence of environmental factors on sensors, and combines the extreme environmental requirements, such as temperature and insulation requirements, to study the sensor. Starting from the sensitivity, the sensing characteristics of the sensor are analyzed. The sensor is designed according to three aspects: sensing material selection, spatial measuring position, and sensing material size optimization, such that it can satisfy the different measurement requirements of towers, overhead ground wires, and transmission lines, respectively. The experiments indicate that the developed sensors can meet the measurement sensitivity requirements of different types of lightning strikes. The experimental results of sensors exhibit a reasonable amplitude measurement accuracy, linearity, and waveform measurement capability. These results provide important theoretical and experimental bases for the application of optical current sensing technology to the measurement of the lightning current of transmission systems.
- Open Access
A Direct Current Measurement Method Based on Terbium Gallium Garnet Crystal and a Double Correlation Detection Algorithm
When applying an optical current transformer (OCT) to direct current measurement, output signals exhibit a low signal-to-noise ratio and signal-to-noise band overlap. Sinusoidal wave modulation is used to solve this problem. A double correlation detection algorithm is used to extract the direct current (DC) signal, remove white noise and improve the signal-to-noise ratio. Our sensing unit uses a terbium gallium garnet crystal in order to increase the output signal-to-noise ratio and measurement sensitivity. Measurement errors of single correlation and double correlation detection algorithms are compared, and experimental results showed that this measurement method can control measurement error to about 0.3%, thus verifying its feasibility.
Open AccessA Direct Current Measurement Method Based on Terbium Gallium Garnet Crystal and a Double Correlation Detection Algorithm
When applying an optical current transformer (OCT) to direct current measurement, output signals exhibit a low signal-to-noise ratio and signal-to-noise band overlap. Sinusoidal wave modulation is used to solve this problem. A double correlation detection algorithm is used to extract the direct current (DC) signal, remove white noise and improve the signal-to-noise ratio. Our sensing unit uses a terbium gallium garnet crystal in order to increase the output signal-to-noise ratio and measurement sensitivity. Measurement errors of single correlation and double correlation detection algorithms are compared, and experimental results showed that this measurement method can control measurement error to about 0.3%, thus verifying its feasibility.
- 6 November 2018
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 61 (2) , 490-497
Optimization of optical current sensor based on rare‐earth magneto‐optical glass
Compared to the present diamagnetic glass used in the sensing element of optical current sensors (OCSs), the high‐sensitivity characteristics of the rare‐earth magneto‐optical glass (REMOG) can significantly improve the performance of an REMOG sensing element. The optimization objective of this study was to enhance the sensitivity of the sensing element and reduce linear birefringence. Theoretical analysis and experimental data were combined to study the practical influences of a few factors, such as the size and spatial position of the glass, the wavelength of the incident light, and the rare‐earth doping concentration, on the sensitivity of an OCS sensing element. Finally, an optimal parameter combination was obtained. The experimental results showed that the response sensitivity of the REMOG sensing element is seven times the sensitivity using diamagnetic glass.
- 6 November 2018
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 61 (2) , 490-497
Optimization of optical current sensor based on rare‐earth magneto‐optical glass
Compared to the present diamagnetic glass used in the sensing element of optical current sensors (OCSs), the high‐sensitivity characteristics of the rare‐earth magneto‐optical glass (REMOG) can significantly improve the performance of an REMOG sensing element. The optimization objective of this study was to enhance the sensitivity of the sensing element and reduce linear birefringence. Theoretical analysis and experimental data were combined to study the practical influences of a few factors, such as the size and spatial position of the glass, the wavelength of the incident light, and the rare‐earth doping concentration, on the sensitivity of an OCS sensing element. Finally, an optimal parameter combination was obtained. The experimental results showed that the response sensitivity of the REMOG sensing element is seven times the sensitivity using diamagnetic glass.
- 26 September 2018
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 60 (10) , 2412-2420
Research on dichotomous optical current sensing technology
Existing optical current transformers (OCTs) have a low measurement accuracy, weak anti‐interference capability, and poor stability during long‐term operation. To address these problems, this paper proposes a dichotomous OCT unit. First, the structure of the unit is proposed, based on a mathematical model, and current measurement methods are presented. Then, a parameter optimization scheme for the shunt frame in the dichotomous OCT units is obtained by analyzing the proposed mathematical model, and a high‐accuracy measurement method is presented for reducing the influence of external magnetic field interferences. The simulation and experimental results show that the dichotomous OCT unit has a high measurement accuracy and strong resistance against external magnetic field interference.
- 26 September 2018
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 60 (10) , 2412-2420
Research on dichotomous optical current sensing technology
Existing optical current transformers (OCTs) have a low measurement accuracy, weak anti‐interference capability, and poor stability during long‐term operation. To address these problems, this paper proposes a dichotomous OCT unit. First, the structure of the unit is proposed, based on a mathematical model, and current measurement methods are presented. Then, a parameter optimization scheme for the shunt frame in the dichotomous OCT units is obtained by analyzing the proposed mathematical model, and a high‐accuracy measurement method is presented for reducing the influence of external magnetic field interferences. The simulation and experimental results show that the dichotomous OCT unit has a high measurement accuracy and strong resistance against external magnetic field interference.
- 1 December 2016
- Published by Elsevier in Sustainable Computing: Informatics and Systems
- Vol. 12, 34-42
Software power modeling method at architecture level based on complex networks
- 1 December 2016
- Published by Elsevier in Sustainable Computing: Informatics and Systems
- Vol. 12, 34-42
Software power modeling method at architecture level based on complex networks
- Open Access
- 16 July 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 87 (1) , 012089
Novel giant magnetostrictive material current sensor
Because of the shortcomings of the traditional inductive current sensor and optical current sensor, this paper proposes a new type of current sensor that uses a giant magnetostrictive material (GMM) to monitor and control power lines. This paper introduces operating principle and structure design of a GMM current sensor. To eliminate the frequency- doubled effect and to obtain good linearity, we set the bias magnetic field to 11.53 kA/m and the prestress force to 6 MPa. The strains of the 100- and 200-mm GMM sticks under the same magnetic field were compared; the results showed that the 100-mm stick had a larger strain. The magnetic field interference during a single-phase measurement of power lines was also studied. Finally, we analyzed the device sensitivity and discussed its influencing factors. The sensitivity reached 4 × 10-9 m2/A.
- 16 July 2015
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 87 (1) , 012089
Open AccessNovel giant magnetostrictive material current sensor
Because of the shortcomings of the traditional inductive current sensor and optical current sensor, this paper proposes a new type of current sensor that uses a giant magnetostrictive material (GMM) to monitor and control power lines. This paper introduces operating principle and structure design of a GMM current sensor. To eliminate the frequency- doubled effect and to obtain good linearity, we set the bias magnetic field to 11.53 kA/m and the prestress force to 6 MPa. The strains of the 100- and 200-mm GMM sticks under the same magnetic field were compared; the results showed that the 100-mm stick had a larger strain. The magnetic field interference during a single-phase measurement of power lines was also studied. Finally, we analyzed the device sensitivity and discussed its influencing factors. The sensitivity reached 4 × 10-9 m2/A.