Zhenhui Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhenhui Du has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Jinyi Li
Tianjin Key Laboratory of Intelligent Control of Electrical Equipment, Tiangong University, Tianjin, China
47 shared publications - Kexin Xu
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China
6 shared publications - Kebin Tong
Tianjin Univ. (China)
5 shared publications - Liming Yuan
Tianjin Univ. (China)
5 shared publications Yiwen Ma
State Key Laboratory of Precision Measuring Technology and Instruments Tianjin University Tianjin 300072 China
5 shared publicationsZehua Wang
5 shared publications
Latest Publications
- Open Access
- 9 October 2026
- Published by American Physical Society (APS) in Physical Review Physics Education Research
- Vol. 22 (2)
Cultivating cross-disciplinary measurement literacy via a unified classical-to-quantum interferometry framework and metrological practices
Measurement claims carry high stakes, yet students and early-career professionals rarely receive explicit training in the reasoning chain that justifies them. Despite growing emphasis on transferable competence, measurement reasoning remains a blind spot: learners seldom map a measurand (the quantity of interest) to an estimand (the reported quantity inferred from data), anchor inference in an explicit noise or likelihood model, or report results with uncertainty and traceability. This fragmentation weakens rigor and communication across domains. We define cross-disciplinary measurement literacy as the ability to connect a measurand to an estimand, justify inference under explicit noise and likelihood models, and report results with uncertainty and traceability. We operationalized this construct through a unified Encoding → Evolution → Readout → Estimation schema integrated with metrological closure and implemented it in a 4 × 2 − h module. This multicohort descriptive evaluation includes five cohorts with verified pre- and postadministration records ( N = 114 ) and two undergraduate team-task cohorts. Cohort-level summaries showed immediate post-test means 34–54 points above pretest means and normalized gains of 0.642–0.782 on an intervention-aligned assessment. Team rubric summaries provided evidence of feasible group-level enactment of the schema, while uncertainty budgeting and traceability remained the principal difficulties. This study is designed as a bounded descriptive evaluation. It provides evidence for the schema’s teachability and its utility as a short-term organizer for measurement reasoning, specifically within the instructional context studied.
- 9 October 2026
- Published by American Physical Society (APS) in Physical Review Physics Education Research
- Vol. 22 (2)
Open AccessCultivating cross-disciplinary measurement literacy via a unified classical-to-quantum interferometry framework and metrological practices
Measurement claims carry high stakes, yet students and early-career professionals rarely receive explicit training in the reasoning chain that justifies them. Despite growing emphasis on transferable competence, measurement reasoning remains a blind spot: learners seldom map a measurand (the quantity of interest) to an estimand (the reported quantity inferred from data), anchor inference in an explicit noise or likelihood model, or report results with uncertainty and traceability. This fragmentation weakens rigor and communication across domains. We define cross-disciplinary measurement literacy as the ability to connect a measurand to an estimand, justify inference under explicit noise and likelihood models, and report results with uncertainty and traceability. We operationalized this construct through a unified Encoding → Evolution → Readout → Estimation schema integrated with metrological closure and implemented it in a 4 × 2 − h module. This multicohort descriptive evaluation includes five cohorts with verified pre- and postadministration records ( N = 114 ) and two undergraduate team-task cohorts. Cohort-level summaries showed immediate post-test means 34–54 points above pretest means and normalized gains of 0.642–0.782 on an intervention-aligned assessment. Team rubric summaries provided evidence of feasible group-level enactment of the schema, while uncertainty budgeting and traceability remained the principal difficulties. This study is designed as a bounded descriptive evaluation. It provides evidence for the schema’s teachability and its utility as a short-term organizer for measurement reasoning, specifically within the instructional context studied.
- 20 March 2026
- Published by Elsevier in Measurement
- Vol. 273
Towards autonomous Spectroscopy: Harmonic geometry Unlocks Calibration-Free diagnostics
- 20 March 2026
- Published by Elsevier in Measurement
- Vol. 273
Towards autonomous Spectroscopy: Harmonic geometry Unlocks Calibration-Free diagnostics
- 1 December 2025
- Published by Elsevier in Measurement
- Vol. 261
Calibration-Free laser spectroscopic thermometry traceable to the Boltzmann constant for high-temperature gas diagnostics
- 1 December 2025
- Published by Elsevier in Measurement
- Vol. 261
Calibration-Free laser spectroscopic thermometry traceable to the Boltzmann constant for high-temperature gas diagnostics
- 23 May 2025
- Published by Elsevier in Measurement
- Vol. 254
Novel Voigt deconvolution for accurate determination of the Lorentzian and Gaussian widths in real-time
- 23 May 2025
- Published by Elsevier in Measurement
- Vol. 254
Novel Voigt deconvolution for accurate determination of the Lorentzian and Gaussian widths in real-time
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Oxygen Concentration and Temperature Mapping Using Single Diode Laser Wavelength Modulation Spectrometry
This study introduces a novel approach for gas concentration and temperature mapping utilizing wavelength modulation spectrometry with a single diode laser. Our method integrates camera imaging and phase-sensitive detection to map oxygen concentration and temperature accurately across various environmental conditions. Validation experiments demonstrate the capability of our system to measure oxygen concentrations as low as 4.2% and temperatures up to 1393.9 K. These results suggest significant potential for advancing multi-dimensional LiDAR technologies for environmental and industrial applications.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Oxygen Concentration and Temperature Mapping Using Single Diode Laser Wavelength Modulation Spectrometry
This study introduces a novel approach for gas concentration and temperature mapping utilizing wavelength modulation spectrometry with a single diode laser. Our method integrates camera imaging and phase-sensitive detection to map oxygen concentration and temperature accurately across various environmental conditions. Validation experiments demonstrate the capability of our system to measure oxygen concentrations as low as 4.2% and temperatures up to 1393.9 K. These results suggest significant potential for advancing multi-dimensional LiDAR technologies for environmental and industrial applications.
- Open Access
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Ultra-low noise front-end design for smart optical sensors with high sensitivity and wide dynamic range
Ultra-low noise is a critical component in the design of high-precision sensor front-ends. We introduced differential phase-sensitive detection (d-PSD) to mitigate both multiplicative and additive noise in optical sensors, aiming for an enhanced performance and cost-effectiveness. The d-PSD combines a capacitive transimpedance amplifier (C-TIA), a delta–sigma analog-to-digital converter (ΔΣ-ADC), and a software-based lock-in amplifier (s-LIA). The first two components utilize the DDC112 (a dual current input 20-bit ADC) for a minimal analog channel length, thus reducing noise efficiently, while the latter employs a cost-effective 32-bit microcontroller unit (MCU), the HC32F460. This approach was successfully implemented as the front-end for a smart optical sensor. Testing indicated that the sensor achieved an equivalent current noise level of 0.6 nA/√Hz, primarily attributed to the light source driver rather than the sensor’s front-end circuit. The sensor exhibited an exceptional performance, with a 3σ measurement precision of 5.4 × 10−4 over a 1-second integration time and a dynamic range of 100 dB, leveraging the proposed method and design. Furthermore, the front-end of the sensor boasts a compact size, low power consumption, and affordability, making it an ideal, versatile solution for ultra-high precision, smart optical sensors.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Open AccessUltra-low noise front-end design for smart optical sensors with high sensitivity and wide dynamic range
Ultra-low noise is a critical component in the design of high-precision sensor front-ends. We introduced differential phase-sensitive detection (d-PSD) to mitigate both multiplicative and additive noise in optical sensors, aiming for an enhanced performance and cost-effectiveness. The d-PSD combines a capacitive transimpedance amplifier (C-TIA), a delta–sigma analog-to-digital converter (ΔΣ-ADC), and a software-based lock-in amplifier (s-LIA). The first two components utilize the DDC112 (a dual current input 20-bit ADC) for a minimal analog channel length, thus reducing noise efficiently, while the latter employs a cost-effective 32-bit microcontroller unit (MCU), the HC32F460. This approach was successfully implemented as the front-end for a smart optical sensor. Testing indicated that the sensor achieved an equivalent current noise level of 0.6 nA/√Hz, primarily attributed to the light source driver rather than the sensor’s front-end circuit. The sensor exhibited an exceptional performance, with a 3σ measurement precision of 5.4 × 10−4 over a 1-second integration time and a dynamic range of 100 dB, leveraging the proposed method and design. Furthermore, the front-end of the sensor boasts a compact size, low power consumption, and affordability, making it an ideal, versatile solution for ultra-high precision, smart optical sensors.
- 31 August 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 304, 123335
A miniaturized photometric ozone sensor using ultraviolet LED with unbalance differential correction and 3D printing
- 31 August 2023
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 304, 123335
A miniaturized photometric ozone sensor using ultraviolet LED with unbalance differential correction and 3D printing
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Simultaneous Measurement of Multiparameter of Diesel Engine Exhaust Based on Mid-Infrared Laser Absorption Spectroscopy
Exhaust parameters of an engine carry vital information that can help to understand its transient duty cycles. We developed a mid-infrared wavelength modulation spectroscopic sensor for simultaneous measurement of exhaust temperature, pressure, and NO and NO 2 concentrations by using two quantum cascade lasers (QCLs) for the first time. The dual-channel signals were demodulated and normalized respectively with a specially designed digital lock-in amplifier, achieving calibration-free measurements to adapt to the harsh and variable working conditions of diesel engines. Two-line thermometry was performed using a newly selected spectral line pair of NO 2 (1629.85 and 1630.33 cm -1 ). Simultaneous measurement of the quadruple parameter of diesel exhaust, i.e. temperature, pressure, and NO and NO 2 concentrations, was first achieved using only three spectral lines and a developed multi-parameter inversion algorithm. The feasibility of the sensor was demonstrated in field tests in an in-service vehicle. Exhaust temperature, pressure, and NO and NO 2 concentrations were obtained continuously with 0.1 s time intervals, which clearly show these parameters in the transition and steady stages of the engine, respectively. The method and results can be used to evaluate the engine operation performance and combustion diagnostics.
- 11 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Simultaneous Measurement of Multiparameter of Diesel Engine Exhaust Based on Mid-Infrared Laser Absorption Spectroscopy
Exhaust parameters of an engine carry vital information that can help to understand its transient duty cycles. We developed a mid-infrared wavelength modulation spectroscopic sensor for simultaneous measurement of exhaust temperature, pressure, and NO and NO 2 concentrations by using two quantum cascade lasers (QCLs) for the first time. The dual-channel signals were demodulated and normalized respectively with a specially designed digital lock-in amplifier, achieving calibration-free measurements to adapt to the harsh and variable working conditions of diesel engines. Two-line thermometry was performed using a newly selected spectral line pair of NO 2 (1629.85 and 1630.33 cm -1 ). Simultaneous measurement of the quadruple parameter of diesel exhaust, i.e. temperature, pressure, and NO and NO 2 concentrations, was first achieved using only three spectral lines and a developed multi-parameter inversion algorithm. The feasibility of the sensor was demonstrated in field tests in an in-service vehicle. Exhaust temperature, pressure, and NO and NO 2 concentrations were obtained continuously with 0.1 s time intervals, which clearly show these parameters in the transition and steady stages of the engine, respectively. The method and results can be used to evaluate the engine operation performance and combustion diagnostics.
- 1 January 2023
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 21 (1) , 011202
Preliminary study on direct measurements and diagnostics for chemical reaction dynamics of NOx by using laser wavelength modulation spectroscopy
Studies on the kinetics of gas-phase chemical reactions currently rely on calculations or simulations and lack simple, fast, and accurate direct measurement methods. We developed a tunable laser molecular absorption spectroscopy measurement system to achieve direct measurements of such reactions by using wavelength modulated spectroscopy and performed online measurements and diagnostics of molecular concentration, reaction temperature, and pressure change during the redox reaction of ozone with nitrogen oxides (NOx) with 0.1 s temporal resolution. This study provides a promising diagnostic tool for studying gas-phase chemical reaction kinetics.
- 1 January 2023
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 21 (1) , 011202
Preliminary study on direct measurements and diagnostics for chemical reaction dynamics of NOx by using laser wavelength modulation spectroscopy
Studies on the kinetics of gas-phase chemical reactions currently rely on calculations or simulations and lack simple, fast, and accurate direct measurement methods. We developed a tunable laser molecular absorption spectroscopy measurement system to achieve direct measurements of such reactions by using wavelength modulated spectroscopy and performed online measurements and diagnostics of molecular concentration, reaction temperature, and pressure change during the redox reaction of ozone with nitrogen oxides (NOx) with 0.1 s temporal resolution. This study provides a promising diagnostic tool for studying gas-phase chemical reaction kinetics.