Hannah L. Nathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hannah L. Nathan has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Andrew H. Shennan
Department of Women and Children's Health St Thomas' Hospital, King's College London London UK
5 shared publications - Lucy C. Chappell
Department of Women and Children's Health, School of Life Course Sciences, King's College London, London, UK
5 shared publications - Mrutyunjaya B. Bellad
Department of Obstetrics and Gynecology, Jawaharlal Nehru Medical College, KLE Academy of Higher Education and Research, Belagavi 590010, Karnataka, India
4 shared publications - Paul Townsend Seed
Department of Women and Children's Health, King's College London, London, UK
4 shared publications - Shivaprasad S. Goudar
Jawaharlal Nehru Medical College, KLE Academy of Higher Education and Research
4 shared publications - Jane Sandall
Department of Women and Children's Health, King's College London, United Kingdom
3 shared publications
Latest Publications
- Open Access
- 26 March 2025
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 5 (3) , e0003890
Eclampsia among adolescent mothers in low- and middle-Income countries
Everyday, approximately 800 pregnant women die from preventable causes, with 95% of these deaths occurring in low- and middle-income countries. Adolescent mothers are disproportionally affected. Hypertensive disorders, including eclampsia, contribute to around 20% of direct maternal deaths, many of which are preventable with simple, cost-effective interventions. This study aims to quantify the risk of eclampsia among adolescent mothers in low- and middle-income countries. This secondary analysis used data from three large multi-center studies within the CRADLE programme of work, conducted across ten regions in Sub-Saharan Africa, India, and Haiti. Data on eclampsia and maternal age were prospectively collected from routine sources and active case finding. The incidence rates of eclampsia were calculated, and the relative risk of eclampsia in adolescents were calculated and compared to non-adolescent mothers. Among 601,343 deliveries, 3,098 cases of eclampsia were recorded (0·51%). The incidence of eclampsia varied widely, from 22 per 10,000 deliveries in Zambia to 142 per 10,000 deliveries in Sierra Leone, a 6·5-fold variation. Adolescents accounted for 34% of eclampsia cases (1065/3098). The relative risk of eclampsia in adolescents compared to older mothers ranged from 1·50 (95% CI 1.32 to 1.83) to 3·45 (95% CI 2.71 to 4.41) across sites (p<0.0001). Adolescent mothers in low- and middle- income countries studied faced a significantly higher risk of eclampsia compared to older mothers. The reproducibility of this finding across diverse settings and time periods highlights the vulnerability of adolescent mothers to health inequalities associated with hypertensive disorders. Further research is needed to explore mechanisms underlying eclampsia in this group, independent of the severity of maternal or fetal disease. Developing targeted interventions and strategies to improve maternal and perinatal outcomes in this high-risk group should be a priority.
- 26 March 2025
- Published by Public Library of Science (PLoS) in PLOS Global Public Health
- Vol. 5 (3) , e0003890
Open AccessEclampsia among adolescent mothers in low- and middle-Income countries
Everyday, approximately 800 pregnant women die from preventable causes, with 95% of these deaths occurring in low- and middle-income countries. Adolescent mothers are disproportionally affected. Hypertensive disorders, including eclampsia, contribute to around 20% of direct maternal deaths, many of which are preventable with simple, cost-effective interventions. This study aims to quantify the risk of eclampsia among adolescent mothers in low- and middle-income countries. This secondary analysis used data from three large multi-center studies within the CRADLE programme of work, conducted across ten regions in Sub-Saharan Africa, India, and Haiti. Data on eclampsia and maternal age were prospectively collected from routine sources and active case finding. The incidence rates of eclampsia were calculated, and the relative risk of eclampsia in adolescents were calculated and compared to non-adolescent mothers. Among 601,343 deliveries, 3,098 cases of eclampsia were recorded (0·51%). The incidence of eclampsia varied widely, from 22 per 10,000 deliveries in Zambia to 142 per 10,000 deliveries in Sierra Leone, a 6·5-fold variation. Adolescents accounted for 34% of eclampsia cases (1065/3098). The relative risk of eclampsia in adolescents compared to older mothers ranged from 1·50 (95% CI 1.32 to 1.83) to 3·45 (95% CI 2.71 to 4.41) across sites (p<0.0001). Adolescent mothers in low- and middle- income countries studied faced a significantly higher risk of eclampsia compared to older mothers. The reproducibility of this finding across diverse settings and time periods highlights the vulnerability of adolescent mothers to health inequalities associated with hypertensive disorders. Further research is needed to explore mechanisms underlying eclampsia in this group, independent of the severity of maternal or fetal disease. Developing targeted interventions and strategies to improve maternal and perinatal outcomes in this high-risk group should be a priority.
- Open Access
- 1 May 2021
- Published by Wolters Kluwer Health in Hypertension
- Vol. 77 (5) , 1714-1722
Pregnancy Outcomes and Blood Pressure Visit-to-Visit Variability and Level in Three Less-Developed Countries
In pregnancy in well-resourced settings, limited data suggest that higher blood pressure (BP) visit-to-visit variability may be associated with adverse pregnancy outcomes. Included were pregnant women in 22 intervention clusters of the CLIP (Community-Level Interventions for Preeclampsia) cluster randomized trials, who had received at least 2 prenatal contacts from a community health worker, including standardized BP measurement. Mixed-effects adjusted logistic regression assessed relationships between pregnancy outcomes and both BP level (median [interquartile range]) and visit-to-visit variability (SD and average real variability [ARV], adjusted for BP level), among all women and those who became hypertensive. The primary outcome was the CLIP composite of maternal and perinatal mortality and morbidity. Among 17 770 pregnancies, higher systolic and diastolic BP levels were associated with increased odds of the composite outcome per 5 mm Hg increase in BP (odds ratio [OR], 1.05 [95% CI, 1.03–1.07] and OR, 1.08 [1.06–1.11], respectively). Higher BP visit-to-visit variability was associated with increased odds, per a SD increase in BP variability measure, of (1) hypertension (systolic: OR, 2.09 [1.98–2.21] for SD and 1.52 [1.45–1.60] for ARV; diastolic: OR, 2.70 [2.54–2.87] for SD and 1.86 [1.76–1.96] for ARV); and (2) the composite outcome (systolic: OR, 1.10 [1.06–1.14] for SD and 1.06 [1.02–1.10] for ARV; diastolic: OR, 1.07 [1.03–1.11] for SD and 1.06 [1.02–1.09] for ARV). In 3 less-developed countries, higher BP level and visit-to-visit variability predicted adverse pregnancy outcomes, providing an opportunity for high-definition medicine.
- 1 May 2021
- Published by Wolters Kluwer Health in Hypertension
- Vol. 77 (5) , 1714-1722
Open AccessPregnancy Outcomes and Blood Pressure Visit-to-Visit Variability and Level in Three Less-Developed Countries
In pregnancy in well-resourced settings, limited data suggest that higher blood pressure (BP) visit-to-visit variability may be associated with adverse pregnancy outcomes. Included were pregnant women in 22 intervention clusters of the CLIP (Community-Level Interventions for Preeclampsia) cluster randomized trials, who had received at least 2 prenatal contacts from a community health worker, including standardized BP measurement. Mixed-effects adjusted logistic regression assessed relationships between pregnancy outcomes and both BP level (median [interquartile range]) and visit-to-visit variability (SD and average real variability [ARV], adjusted for BP level), among all women and those who became hypertensive. The primary outcome was the CLIP composite of maternal and perinatal mortality and morbidity. Among 17 770 pregnancies, higher systolic and diastolic BP levels were associated with increased odds of the composite outcome per 5 mm Hg increase in BP (odds ratio [OR], 1.05 [95% CI, 1.03–1.07] and OR, 1.08 [1.06–1.11], respectively). Higher BP visit-to-visit variability was associated with increased odds, per a SD increase in BP variability measure, of (1) hypertension (systolic: OR, 2.09 [1.98–2.21] for SD and 1.52 [1.45–1.60] for ARV; diastolic: OR, 2.70 [2.54–2.87] for SD and 1.86 [1.76–1.96] for ARV); and (2) the composite outcome (systolic: OR, 1.10 [1.06–1.14] for SD and 1.06 [1.02–1.10] for ARV; diastolic: OR, 1.07 [1.03–1.11] for SD and 1.06 [1.02–1.09] for ARV). In 3 less-developed countries, higher BP level and visit-to-visit variability predicted adverse pregnancy outcomes, providing an opportunity for high-definition medicine.
- Open Access
- 18 April 2019
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 98 (9) , 1178-1186
Shock index thresholds to predict adverse outcomes in maternal hemorrhage and sepsis: A prospective cohort study
Introduction: Shock index (SI) is a predictor of hemodynamic compromise in obstetric patients. The SI threshold for action is not well understood. We aimed to evaluate SI thresholds as predictors of outcomes in obstetric patients.Material and methods: We undertook a prospective cohort study at three South African hospitals of women with postpartum hemorrhage (n = 283) or maternal sepsis (n = 126). The “first” and “worst” SI following diagnosis were recorded. SI was compared with conventional vital signs as predictors of outcomes. The performance of SI <.9, SI .9‐1.69 and SI ≥1.7 to predict outcomes (maternal death; Critical Care Unit admission; major procedure; hysterectomy) and hemorrhage‐specific outcomes (lowest hemoglobin <70 g/l; blood transfusion ≥4 IU) were evaluated.Results: “First” SI was one of two best performing vital signs for every outcome in postpartum hemorrhage and sepsis. In hemorrhage, risk of all outcomes increased with increasing “first” SI; for blood transfusion ≥4 IU odds ratio was 4.24 (95% confidence interval 1.25‐14.36) for SI ≥1.7 vs SI .9‐1.69. In sepsis, risk of all outcomes increased with increasing “worst” SI. Sensitivity, specificity, positive and negative predictive values of “first” SI <.9 vs SI ≥.9 for maternal death were 100.0%, 55.2%, 4.6% and 100.0%, respectively, in hemorrhage and 80.0%, 50.4%, 12.3% and 96.7%, respectively, in sepsis.Conclusions: The shock index was a consistent predictor of outcomes compared with conventional vital signs in postpartum hemorrhage and sepsis. SI <.9 performed well as a rule‐out test and SI .9‐1.69 and SI ≥1.7 indicated increased risk of all outcomes in both cohorts. These thresholds may alert to the need for urgent intervention and prevent maternal deaths.
- 18 April 2019
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 98 (9) , 1178-1186
Open AccessShock index thresholds to predict adverse outcomes in maternal hemorrhage and sepsis: A prospective cohort study
Introduction: Shock index (SI) is a predictor of hemodynamic compromise in obstetric patients. The SI threshold for action is not well understood. We aimed to evaluate SI thresholds as predictors of outcomes in obstetric patients.Material and methods: We undertook a prospective cohort study at three South African hospitals of women with postpartum hemorrhage (n = 283) or maternal sepsis (n = 126). The “first” and “worst” SI following diagnosis were recorded. SI was compared with conventional vital signs as predictors of outcomes. The performance of SI <.9, SI .9‐1.69 and SI ≥1.7 to predict outcomes (maternal death; Critical Care Unit admission; major procedure; hysterectomy) and hemorrhage‐specific outcomes (lowest hemoglobin <70 g/l; blood transfusion ≥4 IU) were evaluated.Results: “First” SI was one of two best performing vital signs for every outcome in postpartum hemorrhage and sepsis. In hemorrhage, risk of all outcomes increased with increasing “first” SI; for blood transfusion ≥4 IU odds ratio was 4.24 (95% confidence interval 1.25‐14.36) for SI ≥1.7 vs SI .9‐1.69. In sepsis, risk of all outcomes increased with increasing “worst” SI. Sensitivity, specificity, positive and negative predictive values of “first” SI <.9 vs SI ≥.9 for maternal death were 100.0%, 55.2%, 4.6% and 100.0%, respectively, in hemorrhage and 80.0%, 50.4%, 12.3% and 96.7%, respectively, in sepsis.Conclusions: The shock index was a consistent predictor of outcomes compared with conventional vital signs in postpartum hemorrhage and sepsis. SI <.9 performed well as a rule‐out test and SI .9‐1.69 and SI ≥1.7 indicated increased risk of all outcomes in both cohorts. These thresholds may alert to the need for urgent intervention and prevent maternal deaths.
- Open Access
- 12 April 2019
- Published by Public Library of Science (PLoS) in PLOS Medicine
- Vol. 16 (4) , e1002783
The incidence of pregnancy hypertension in India, Pakistan, Mozambique, and Nigeria: A prospective population-level analysis
Most pregnancy hypertension estimates in less-developed countries are from cross-sectional hospital surveys and are considered overestimates. We estimated population-based rates by standardised methods in 27 intervention clusters of the Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised trials. CLIP-eligible pregnant women identified in their homes or local primary health centres (2013–2017). Included here are women who had delivered by trial end and received a visit from a community health worker trained to provide supplementary hypertension-oriented care, including standardised blood pressure (BP) measurement. Hypertension (BP ≥ 140/90 mm Hg) was defined as chronic (first detected at p < 0.05 considered significant). In 28,420 pregnancies studied, women were usually young (median age 23–28 years), parous (53.7%–77.3%), with singletons (≥97.5%), and enrolled at a median gestational age of 10.4 (India) to 25.9 weeks (Mozambique). Basic education varied (22.8% in Pakistan to 57.9% in India). Pregnancy hypertension incidence was lower in Pakistan (9.3%) than India (10.3%), Mozambique (10.9%), or Nigeria (10.2%) (p = 0.001). Most hypertension was diastolic only (46.4% in India, 72.7% in Pakistan, 61.3% in Mozambique, and 63.3% in Nigeria). At first presentation with elevated BP, gestational hypertension was most common diagnosis (particularly in Mozambique [8.4%] versus India [6.9%], Pakistan [6.5%], and Nigeria [7.1%]; p < 0.001), followed by pre-eclampsia (India [3.8%], Nigeria [3.0%], Pakistan [2.4%], and Mozambique [2.3%]; p < 0.001) and chronic hypertension (especially in Mozambique [2.5%] and Nigeria [2.8%], compared with India [1.2%] and Pakistan [1.5%]; p < 0.001). Inclusion of additional diagnoses of hypertension and related complications, from household surveys or facility record review (unavailable in Nigeria), revealed higher hypertension incidence: 14.0% in India, 11.6% in Pakistan, and 16.8% in Mozambique; eclampsia was rare (<0.5%). Pregnancy hypertension is common in less-developed settings. Most women in this study presented with gestational hypertension amenable to surveillance and timed delivery to improve outcomes. This study is a secondary analysis of a clinical trial - ClinicalTrials.gov registration number NCT01911494.
- 12 April 2019
- Published by Public Library of Science (PLoS) in PLOS Medicine
- Vol. 16 (4) , e1002783
Open AccessThe incidence of pregnancy hypertension in India, Pakistan, Mozambique, and Nigeria: A prospective population-level analysis
Most pregnancy hypertension estimates in less-developed countries are from cross-sectional hospital surveys and are considered overestimates. We estimated population-based rates by standardised methods in 27 intervention clusters of the Community-Level Interventions for Pre-eclampsia (CLIP) cluster randomised trials. CLIP-eligible pregnant women identified in their homes or local primary health centres (2013–2017). Included here are women who had delivered by trial end and received a visit from a community health worker trained to provide supplementary hypertension-oriented care, including standardised blood pressure (BP) measurement. Hypertension (BP ≥ 140/90 mm Hg) was defined as chronic (first detected at p < 0.05 considered significant). In 28,420 pregnancies studied, women were usually young (median age 23–28 years), parous (53.7%–77.3%), with singletons (≥97.5%), and enrolled at a median gestational age of 10.4 (India) to 25.9 weeks (Mozambique). Basic education varied (22.8% in Pakistan to 57.9% in India). Pregnancy hypertension incidence was lower in Pakistan (9.3%) than India (10.3%), Mozambique (10.9%), or Nigeria (10.2%) (p = 0.001). Most hypertension was diastolic only (46.4% in India, 72.7% in Pakistan, 61.3% in Mozambique, and 63.3% in Nigeria). At first presentation with elevated BP, gestational hypertension was most common diagnosis (particularly in Mozambique [8.4%] versus India [6.9%], Pakistan [6.5%], and Nigeria [7.1%]; p < 0.001), followed by pre-eclampsia (India [3.8%], Nigeria [3.0%], Pakistan [2.4%], and Mozambique [2.3%]; p < 0.001) and chronic hypertension (especially in Mozambique [2.5%] and Nigeria [2.8%], compared with India [1.2%] and Pakistan [1.5%]; p < 0.001). Inclusion of additional diagnoses of hypertension and related complications, from household surveys or facility record review (unavailable in Nigeria), revealed higher hypertension incidence: 14.0% in India, 11.6% in Pakistan, and 16.8% in Mozambique; eclampsia was rare (<0.5%). Pregnancy hypertension is common in less-developed settings. Most women in this study presented with gestational hypertension amenable to surveillance and timed delivery to improve outcomes. This study is a secondary analysis of a clinical trial - ClinicalTrials.gov registration number NCT01911494.
- Open Access
- 19 September 2018
- Published by BMJ in BMJ Innovations
- Vol. 4 (4) , 192-198
Development and evaluation of a novel Vital Signs Alert device for use in pregnancy in low-resource settings
Objectives Haemorrhage, hypertension, sepsis and abortion complications (often from haemorrhage or sepsis) contribute to 60% of all maternal deaths. Each is associated with vital signs (blood pressure (BP) and pulse) abnormalities, and the majority of deaths are preventable through simple and timely intervention. This paper presents the development and evaluation of the CRADLE Vital Signs Alert (VSA), an accurate, low-cost and easy-to-use device measuring BP and pulse with an integrated traffic light early warning system. The VSA was designed to be used by all cadres of healthcare providers for pregnant women in low-resource settings with the aim to prevent avoidable maternal mortality and morbidity. Methods The development and the mixed-methods clinical evaluation of the VSA are described. Results Preliminary fieldwork identified that introduction of BP devices to rural clinics improved antenatal surveillance of BP in pregnant women. The aesthetics of the integrated traffic light system were developed through iterative qualitative evaluation. The traffic lights trigger according to evidence-based vital sign thresholds in hypertension and haemodynamic compromise from haemorrhage and sepsis. The VSA can be reliably used as an auscultatory device, as well as its primary semiautomated function, and is suitable as a self-monitor used by pregnant women. Conclusion The VSA is an accurate device incorporating an evidence-based traffic light early warning system. It is designed to ensure suitability for healthcare providers with limited training and may improve care for women in pregnancy, childbirth and in the postnatal period.
- 19 September 2018
- Published by BMJ in BMJ Innovations
- Vol. 4 (4) , 192-198
Open AccessDevelopment and evaluation of a novel Vital Signs Alert device for use in pregnancy in low-resource settings
Objectives Haemorrhage, hypertension, sepsis and abortion complications (often from haemorrhage or sepsis) contribute to 60% of all maternal deaths. Each is associated with vital signs (blood pressure (BP) and pulse) abnormalities, and the majority of deaths are preventable through simple and timely intervention. This paper presents the development and evaluation of the CRADLE Vital Signs Alert (VSA), an accurate, low-cost and easy-to-use device measuring BP and pulse with an integrated traffic light early warning system. The VSA was designed to be used by all cadres of healthcare providers for pregnant women in low-resource settings with the aim to prevent avoidable maternal mortality and morbidity. Methods The development and the mixed-methods clinical evaluation of the VSA are described. Results Preliminary fieldwork identified that introduction of BP devices to rural clinics improved antenatal surveillance of BP in pregnant women. The aesthetics of the integrated traffic light system were developed through iterative qualitative evaluation. The traffic lights trigger according to evidence-based vital sign thresholds in hypertension and haemodynamic compromise from haemorrhage and sepsis. The VSA can be reliably used as an auscultatory device, as well as its primary semiautomated function, and is suitable as a self-monitor used by pregnant women. Conclusion The VSA is an accurate device incorporating an evidence-based traffic light early warning system. It is designed to ensure suitability for healthcare providers with limited training and may improve care for women in pregnancy, childbirth and in the postnatal period.
- Open Access
- 27 April 2018
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 18 (1) , 115
Evaluation of a novel vital sign device to reduce maternal mortality and morbidity in low-resource settings: a mixed method feasibility study for the CRADLE-3 trial
The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined. The fidelity, dose, feasibility and acceptability of implementation and training materials were assessed in three representative non-trial sites (Zimbabwe, Ethiopia, India) using multiple-choice questionnaires, evaluation of clinical management (action log), healthcare provider (HCP) semi-structured interviews and focus groups 4–10 weeks after implementation. Simultaneously, the 10 sites included in the main trial (eight countries) collected primary outcome data to inform the power calculation and randomisation allocation and assess the feasibility of data collection. The package was implemented with high fidelity (85% of HCP trained, n = 204). The questionnaires indicated a good understanding of device use with 75% of participants scoring > 75% (n = 97; 90% of those distributed). Action logs were inconsistently completed but indicated that the majority of HCP responded appropriately to abnormal results. From 18 HCP interviews and two focus groups it was widely reported that the intervention improved capacity to make clinical decisions, escalate care and make appropriate referrals. Nine of the ten main trial sites achieved ethical approval for pilot data collection. Intensive care was an inconsistent marker of morbidity and stroke an infrequent outcome and therefore they were removed from the main trial composite outcome. Tools and methods of data collection were optimized and event rates used to inform randomisation. This feasibility study demonstrates that the components of the intervention were acceptable, methods of implementing were successful and the main trial design would be feasible. Qualitative work identified key moderators that informed the main trial process evaluation. Changes to the training package, implementation strategy, study design and processes were identified to refine the implementation in the main trial. ISRCTN41244132 ; Registered 24/11/2015.
- 27 April 2018
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 18 (1) , 115
Open AccessEvaluation of a novel vital sign device to reduce maternal mortality and morbidity in low-resource settings: a mixed method feasibility study for the CRADLE-3 trial
The CRADLE-3 trial is a stepped-wedge randomised controlled trial aiming to reduce maternal mortality and morbidity by implementing a novel vital sign device (CRADLE Vital Sign Alert) and training package into routine maternity care in 10 low-income sites. The MRC Guidance on complex interventions proposes that interventions and implementation strategies be shaped by early phase piloting and development work. We present the findings of a three-month mixed-methodology feasibility study for this trial, describe how this was informed by the MRC guidance and the study design was refined. The fidelity, dose, feasibility and acceptability of implementation and training materials were assessed in three representative non-trial sites (Zimbabwe, Ethiopia, India) using multiple-choice questionnaires, evaluation of clinical management (action log), healthcare provider (HCP) semi-structured interviews and focus groups 4–10 weeks after implementation. Simultaneously, the 10 sites included in the main trial (eight countries) collected primary outcome data to inform the power calculation and randomisation allocation and assess the feasibility of data collection. The package was implemented with high fidelity (85% of HCP trained, n = 204). The questionnaires indicated a good understanding of device use with 75% of participants scoring > 75% (n = 97; 90% of those distributed). Action logs were inconsistently completed but indicated that the majority of HCP responded appropriately to abnormal results. From 18 HCP interviews and two focus groups it was widely reported that the intervention improved capacity to make clinical decisions, escalate care and make appropriate referrals. Nine of the ten main trial sites achieved ethical approval for pilot data collection. Intensive care was an inconsistent marker of morbidity and stroke an infrequent outcome and therefore they were removed from the main trial composite outcome. Tools and methods of data collection were optimized and event rates used to inform randomisation. This feasibility study demonstrates that the components of the intervention were acceptable, methods of implementing were successful and the main trial design would be feasible. Qualitative work identified key moderators that informed the main trial process evaluation. Changes to the training package, implementation strategy, study design and processes were identified to refine the implementation in the main trial. ISRCTN41244132 ; Registered 24/11/2015.
- Open Access
- 1 April 2018
- Published by Elsevier in Pregnancy Hypertension
- Vol. 12, 183-188
Early warning system hypertension thresholds to predict adverse outcomes in pre-eclampsia: A prospective cohort study
- 1 April 2018
- Published by Elsevier in Pregnancy Hypertension
- Vol. 12, 183-188
Open AccessEarly warning system hypertension thresholds to predict adverse outcomes in pre-eclampsia: A prospective cohort study
- Open Access
- 5 January 2018
- Published by Springer Nature in Reproductive Health
- Vol. 15 (1) , 5
The CRADLE vital signs alert: qualitative evaluation of a novel device designed for use in pregnancy by healthcare workers in low-resource settings
Vital signs measurement can identify pregnant and postpartum women who require urgent treatment or referral. In low-resource settings, healthcare workers have limited access to accurate vital signs measuring devices suitable for their environment and training. The CRADLE Vital Signs Alert (VSA) is a novel device measuring blood pressure and pulse that is accurate in pregnancy and designed for low-resource settings. Its traffic light early warning system alerts healthcare workers to the need for escalation of care for women with hypertension, haemorrhage or sepsis. This study evaluated the usability and acceptability of the CRADLE VSA device. Evaluation was conducted in community and primary care settings in India, Mozambique and Nigeria and tertiary hospitals in South Africa. Purposeful sampling was used to convene 155 interviews and six focus groups with healthcare workers using the device (n = 205) and pregnant women and their family members (n = 41). Interviews and focus groups were conducted in the local language and audio-recorded, transcribed and translated into English for analysis. Thematic analysis was undertaken using an a priori thematic framework, as well as an inductive approach. Most healthcare workers perceived the CRADLE device to be easy to use and accurate. The traffic lights early warning system was unanimously reported positively, giving healthcare workers confidence with decision-making and a sense of professionalism. However, a minority in South Africa described manual inflation as tiring, particularly when measuring vital signs in obese and hypertensive women (n = 4) and a few South African healthcare workers distrusted the device’s accuracy (n = 7). Unanimously, pregnant women liked the CRADLE device. The traffic light early warning system gave women and their families a better understanding of the importance of vital signs in pregnancy and during the postpartum period. The CRADLE device was well accepted by healthcare workers from a range of countries and levels of facility, including those with no previous vital signs measurement experience. The device motivated women to attend primary care and encouraged them to accept treatment and referral.
- 5 January 2018
- Published by Springer Nature in Reproductive Health
- Vol. 15 (1) , 5
Open AccessThe CRADLE vital signs alert: qualitative evaluation of a novel device designed for use in pregnancy by healthcare workers in low-resource settings
Vital signs measurement can identify pregnant and postpartum women who require urgent treatment or referral. In low-resource settings, healthcare workers have limited access to accurate vital signs measuring devices suitable for their environment and training. The CRADLE Vital Signs Alert (VSA) is a novel device measuring blood pressure and pulse that is accurate in pregnancy and designed for low-resource settings. Its traffic light early warning system alerts healthcare workers to the need for escalation of care for women with hypertension, haemorrhage or sepsis. This study evaluated the usability and acceptability of the CRADLE VSA device. Evaluation was conducted in community and primary care settings in India, Mozambique and Nigeria and tertiary hospitals in South Africa. Purposeful sampling was used to convene 155 interviews and six focus groups with healthcare workers using the device (n = 205) and pregnant women and their family members (n = 41). Interviews and focus groups were conducted in the local language and audio-recorded, transcribed and translated into English for analysis. Thematic analysis was undertaken using an a priori thematic framework, as well as an inductive approach. Most healthcare workers perceived the CRADLE device to be easy to use and accurate. The traffic lights early warning system was unanimously reported positively, giving healthcare workers confidence with decision-making and a sense of professionalism. However, a minority in South Africa described manual inflation as tiring, particularly when measuring vital signs in obese and hypertensive women (n = 4) and a few South African healthcare workers distrusted the device’s accuracy (n = 7). Unanimously, pregnant women liked the CRADLE device. The traffic light early warning system gave women and their families a better understanding of the importance of vital signs in pregnancy and during the postpartum period. The CRADLE device was well accepted by healthcare workers from a range of countries and levels of facility, including those with no previous vital signs measurement experience. The device motivated women to attend primary care and encouraged them to accept treatment and referral.
- 1 February 2015
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 20 (1) , 52-55
An accurate semiautomated oscillometric blood pressure device for use in pregnancy (including pre-eclampsia) in a low-income and middle-income country population
Objectives To assess the accuracy of the Microlife 3AS1-2 blood pressure device in pregnancy and pre-eclampsia in a low-resource setting. Methods Prospective validation according to the British Hypertension Society protocol. A total of 45 pregnant women were recruited from Kimberley Hospital (South Africa), of whom 15 had pre-eclampsia. Results The Microlife 3AS1-2 device achieved an overall B/A grade in pregnancy (including pre-eclampsia), passing the British Hypertension Society protocol requirements and achieving the International Organization for Standardization standard with a mean difference and SD of −3.8±7.3 and −1.5±6.2 mmHg for systolic and diastolic pressures, respectively. Conclusion The Microlife 3AS1-2 device can be recommended for use in pregnancy, including pre-eclampsia. In addition, it fulfils the requirements stipulated by the WHO for an automated blood pressure device suitable for use in a low-resource setting. This makes it the ideal device for antenatal clinics and primary healthcare facilities in low-income and middle-income countries.
- 1 February 2015
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 20 (1) , 52-55
An accurate semiautomated oscillometric blood pressure device for use in pregnancy (including pre-eclampsia) in a low-income and middle-income country population
Objectives To assess the accuracy of the Microlife 3AS1-2 blood pressure device in pregnancy and pre-eclampsia in a low-resource setting. Methods Prospective validation according to the British Hypertension Society protocol. A total of 45 pregnant women were recruited from Kimberley Hospital (South Africa), of whom 15 had pre-eclampsia. Results The Microlife 3AS1-2 device achieved an overall B/A grade in pregnancy (including pre-eclampsia), passing the British Hypertension Society protocol requirements and achieving the International Organization for Standardization standard with a mean difference and SD of −3.8±7.3 and −1.5±6.2 mmHg for systolic and diastolic pressures, respectively. Conclusion The Microlife 3AS1-2 device can be recommended for use in pregnancy, including pre-eclampsia. In addition, it fulfils the requirements stipulated by the WHO for an automated blood pressure device suitable for use in a low-resource setting. This makes it the ideal device for antenatal clinics and primary healthcare facilities in low-income and middle-income countries.