SCSebastião Cronemberger

Sebastião Cronemberger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastião Cronemberger has a total of 62 co-authors. Here are the top co-authors by number of shared publications:

  • Alberto Diniz-Filho

    Department of Ophthalmology and Otorhinolaryngology, Federal University of Minas Gerais, Belo Horizonte, Brazil

    5 shared publications
  • Artur W. Veloso

    Glaucoma Service Professor Nassim Calixto, Hospital São Geraldo, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil

    5 shared publications
  • Nassim Calixto

    Department of Ophthalmology, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil

    4 shared publications
  • Rafael Vidal Merola

    Nassim Calixto Glaucoma Service of São Geraldo Eye Hospital, Clinic Hospital, Federal University of Minas Gerais-Belo Horizonte, Belo Horizonte 30130-100, State of Minas Gerais, Brazil

    4 shared publications
  • Alexandre Higino Gonçalves da Silva

    Glaucoma Service Professor Nassim Calixto, Hospital São Geraldo, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil

    2 shared publications
  • Artur William Veloso

    Nassim Calixto Glaucoma Service of São Geraldo Eye Hospital, Clinic Hospital, Federal University of Minas Gerais-Belo Horizonte, Belo Horizonte 30130-100, State of Minas Gerais, Brazil

    2 shared publications

Latest Publications

  • Association Between 24-Hour Intraocular Pressure Fluctuation and Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography

    by Artur W. Veloso, Sebastião Cronemberger, Camilo Brandão-De-Resende, Alessandro A. Jammal, Alberto Diniz-Filho

    Précis: Abnormal short-term fluctuation of intraocular pressure is associated with thinner global retinal nerve fiber layer thickness in subjects with primary open angle glaucoma and glaucoma suspects. Purpose: To evaluate the relationship between 24-hour fluctuation of intraocular pressure (IOP F ) and RNFL thickness measured by spectral-domain optical coherence tomography (SD-OCT). Methods: The study included 153 eyes of 80 patients. Seventy-five eyes (49%) were considered glaucoma suspects, and 78 (51%) had a diagnosis of POAG. All eyes underwent peripapillary RNFL imaging with SD-OCT, standard automated perimetry (SAP), and 24-hour IOP measurements. Generalized linear mixed models were used to investigate the relationship between IOP F and RNFL thickness, adjusting for potential confounders, including age, glaucoma diagnosis, central corneal thickness, number of medications, mean IOP over 24 hours, and disease severity. Results: The mean age was 60.0±18.7 years for glaucoma suspects and 64.7±12.4 years for POAG patients. In univariable analyses, IOP F was associated with global RNFL thickness ( P =0.012), but mean and peak IOP during the 24-hour period were not ( P =0.492 and 0.229, respectively). When adjusted for confounding factors in the multivariable analysis, each 1 mm Hg increase in IOP F was associated with a 2.30 µm thinner global RNFL (95% CI: −4.25 to −0.36 µm, P =0.021). Conclusion: Higher IOP F was associated with thinner global RNFL thickness measured by SD-OCT. This finding corroborates a potential role for IOP fluctuation as a risk factor for structural loss in glaucoma.

  • Open Access

    Quantitative analysis of intraocular pressure and clinical-morphometric characteristics in Peters’ anomaly: a single-center study

    by Sebastião Cronemberger, Artur W. Veloso, Maria Valeria C. Pereira, Felipe Leão de Lima, Alexandre Higino Gonçalves da Silva, Luciana de Figueiredo Barbosa, Eduardo Gutemberg Milhomens, Márcio Placedino Martins

    Purpose: To quantitatively analyze intraocular pressure (IOP) alongside clinical and morphometric findings in a cohort of children with Peters’ anomaly (PA).Methods: This single-center retrospective study included a series of 46 children with PA. Glaucoma diagnosis in a subset was based on abnormal values of IOP, horizontal corneal diameter (HCD), or axial length (AL), individually or combined, compared to pediatric controls utilizing age-specific normative data. Patients were clinically classified into Peters I, II, III, and Peters-plus syndrome. Ultrasound biomicroscopy (UBM) was performed in 10 children.Results: The cohort of 46 children comprised 27 males and 19 females. All presented with central discoid corneal opacities; 33 cases were bilateral, 13 unilateral. Clinical classifications included 26 Peters I, 10 Peters II, 7 Peters III, and 3 Peters-plus syndrome. In the 29 children analyzed for biometrics, the median age at diagnosis was 7 months (IQR: 1.00–21.00). Median AL was 20.84 mm (IQR: 19.36–22.47 mm) for OD and 20.19 mm (IQR: 18.67–24.05 mm) for OS. Median HCD was 11.5 mm (IQR: 10.50–12.50 mm) for OD and 11.5 mm (IQR: 10.50–13.00 mm) for OS. Glaucoma was diagnosed in 14 patients (48.3%). A significant increase in glaucoma prevalence was observed in children >6 months old (53.6%) compared to those 0–6 months old (26.7%) (p = 0.03).Conclusion: HCD and AL in PA often remain within normal limits, suggesting unique corneal biomechanics. Glaucoma in PA frequently manifests after 6 months of age, necessitating continuous monitoring.

  • Open Access

    Reply to Barone to 24-hour intraocular pressure monitoring: past, present and future

    by Sebastião Cronemberger

    Dear Editor, I deeply thank Dr. Borrone for his comments on the Editorial published at Revista Brasileira de Oftalmologia, volume 83.() Very interesting paper published by Dr. Borrone in the European Journal of Ophthalmology, which should have to be quoted.() However, our experience is different. In ARVO, 2016, we presented the Abstract Comparison of 24-Hour IOP Measurements in Sitting and Supine Positions in Glaucoma with the purpose of assessing the correlation and agreement between sitting and supine intraocular pressure (IOP) [...] Dear Editor, I deeply thank Dr. Borrone for his comments on the Editorial published at Revista Brasileira de Oftalmologia, volume 83.() Very interesting paper published by Dr. Borrone in the European Journal of Ophthalmology, which should have to be quoted.() However, our experience is different. In ARVO, 2016, we presented the Abstract Comparison of 24-Hour IOP Measurements in Sitting and Supine Positions in Glaucoma with the purpose of assessing the correlation and agreement between sitting and supine intraocular pressure (IOP)

  • Open Access

    24-hour intraocular pressure monitoring: past, present, and future

    by Sebastião Cronemberger

    HISTORY Richard Banister (1622) was the first to associate the loss of vision by glaucoma with high levels of IOP.() Adolph Weber (1855) was the first to establish the concept of glaucoma as an optic neuropathy.() In 1864, eserine and physostigmine (miotics) were introduced as the first drugs extracted from a plant used to treat the progression of glaucoma.() It is well known that elevated or uncontrolled IOP cause the excavation of the optic disc (glaucomatous excavation) and visual field [...] HISTORY Richard Banister (1622) was the first to associate the loss of vision by glaucoma with high levels of IOP.() Adolph Weber (1855) was the first to establish the concept of glaucoma as an optic neuropathy.() In 1864, eserine and physostigmine (miotics) were introduced as the first drugs extracted from a plant used to treat the progression of glaucoma.() It is well known that elevated or uncontrolled IOP cause the excavation of the optic disc (glaucomatous excavation) and visual field


  • Open Access

    Glaucoma drainage devices in children: an updated review

    by Alex Teles Vasconcelos, José Aloisio Massote, Cassia Senger, Lívia Prudente Barbieri, Sebastião Cronemberger, Jayter Silva Paula

    Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


  • Influence of unilateral eyelid spasms and botulinum toxin treatment on intraocular pressure measured by transpalpebral tonometer

    by Danielle Pimenta Viana Trindade, Sebastião Cronemberger, Artur W. Veloso, Francisco Eduardo Costa Cardoso, Tammy H. Osaki

    Purpose Eyelid spasms might be associated with elevated intraocular pressure (IOP) in hemifacial spasm (HFS) patients. IOP assessment using a Goldmann applanation tonometer (GAT) is often compromised by eyelid spasms. This study aimed to assess the effect of HFS on IOP measurements using the transpalpebral tonometer Diaton® before and after treatment with botulinum toxin type A (BTX-A) and compared Diaton® and GAT measurements after treatment with BTX-A. Methods IOP measurements were obtained with Diaton® in 27 patients with moderate-to-severe HFS before and after treatment with BTX-A. After treatment, the IOP was also measured using GAT and the results were compared with the ones measured with a Diaton®. The patients underwent automated perimetry, OCT, and pachymetry for screening to glaucoma. Results Mean IOP with Diaton® was 11 ± 3.42 mmHg before treatment in the affected eye and 9 ± 2.98 mmHg in the contralateral eye. This difference was statistically significant (P = 0.012). However, after treatment with BTX-A, no interocular difference was found in IOP obtained with Diaton® (P = 0.204) or GAT (P = 0.971). Comparison between GAT and Diaton® measurements showed no significant differences after BTX-A treatment between the affected (P = 0.212) and contralateral eye (P = 0.971). Conclusions A significant reduction in IOP measurements on the affected side of HFS patients was observed after treatment with BTX-A, demonstrating that eyelid spasms may increase the IOP. No significant difference was observed between Diaton® and GAT measurements after the application of BTX-A. No differences were found in automated perimetry, OCT, and CCT when comparing affected eyes with contralateral eyes.

  • Bilateral acute iris transillumination (BAIT) syndrome: Differential diagnosis based on clinical, OCT and UBM findings

    by Sebastião Cronemberger, Daniel Vítor Vasconcelos-Santos, Clóvis Correia de Carvalho, José Herculano Carvalho, Júlia Calixto, Alberto Diniz-Filho

    Introduction: Bilateral acute iris transillumination (BAIT) is a relatively new syndrome whose etiopathogenesis is still not fully understood. It is characterized by acute bilateral onset of intense pigment dispersion in the anterior chamber, iris depigmentation with severe transillumination defects, accentuated pigment deposition in the angle, and elevated intraocular pressure (IOP). In literature, the first case was of bilateral acute iris depigmentation (BADI) reported in 2004 in a 77-year-old woman. In 2019, Perone et al. published a review about BAIT syndrome. They reported a total of 79 cases have been published up that date, mainly in Europe and especially in Turkey and Belgium. The majority of reported cases were of bilateral acute iris depigmentation (BADI). BAIT syndrome might be mainly confused with acute iridocyclitis, acute primary angle-closure (APAC) and pigment dispersion syndrome (PDS). In relation to BAIT, controversies still exist regarding the etiology being the differential diagnosis of paramount importance for adequate treatment. Purpose: To report a case of BAIT syndrome associated to refractory glaucoma and to discuss the differential diagnosis based on clinical, OCT and UBM findings. Methods: We present a case of BAIT syndrome in which clinical, OCT and UBM findings have pointed out the similarities and, mainly the diagnosis differences with other ocular diseases. Conclusions: BAIT syndrome with accentuated IOP rise must be differentiated of other ocular diseases. It requires urgent clinical therapy and/or surgical management as occurred in the present case for avoiding structural damage in OCT and visual field loss. OCT and UBM are critical for early recognition, differential diagnosis and management.


  • Outcomes of early versus delayed trabeculotomy for primary congenital glaucoma

    by Sebastião Cronemberger, Artur W. Veloso, Pedro Lins, Ana Catarina Melo, Alexandre Higino Gonçalves da Silva, Luciana de Figueiredo Barbosa, Márcio Placedino Martins

    Purpose: In patients with primary congenital glaucoma (PCG), elevated intraocular pressure (IOP) causes abnormal eye growth. This study compared the outcomes of children with PCG who underwent ab externo trabeculotomy (TROC) at age ≤ 6 months (early TROC) and of those who underwent TROC at age > 6 months (delayed TROC).Methods: Intraocular pressure, horizontal corneal diameter (HCD), central corneal thickness (CCT) and axial length (AL) were compared before TROC and at 1‐, 3‐, 6‐ and 12‐month follow‐up visits between the groups of children who underwent TROC until or after 6 months of age. The ALs of these groups were also compared with the ALs of healthy age‐matched eyes examined under the same conditions.Results: Trabeculotomy was performed in 43 children: 18 (33 eyes) aged 6 months (group 1) and 25 (37 eyes) aged >6 months (group 2); the mean ages were 86.56 ± 53.64 and 504.48 ± 448.14 days, respectively. The mean pre‐ and 12‐month postoperative IOP values were 15.97 ± 4.78/16.62 ± 4.85 and 9.77 ± 2.88/10.93 ± 4.83 mmHg, respectively. Delayed TROC was associated with abnormal AL in 31 (88.6%) out of 37 eyes, while after early TROC, only 13 (41.9%) out of 33 eyes had abnormal AL (chi‐square, 8.00; p = 0.03). In multivariable analysis, each 1‐mmHg increase in preoperative IOP was associated with a 0.25‐mmHg increase at 12 months (p = 0.04). On average, the mean IOP of the delayed TROC group was higher than that of the early TROC group by 3.72 mmHg at postoperative month 12 (95% CI = 0.44–6.99; p = 0.02).Conclusion: Compared with delayed TROC, early TROC is associated with reduced IOP and substantially reduced incidence of abnormal AL at postoperative month 12.


  • Open Access

    SD-OCT assessment and visual field changes 1 year or more after a single episode of unilateral acute primary angle closure

    by Rafael Vidal Merola, Sebastião Cronemberger, Érica de Abreu Borges, Jamily Batista Prates

    Objective: To evaluate structural and visual field (VF) changes after ≥1 year of a single acute primary angle closure (APAC) attack using spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP). Methods: Patients with a single unilateral APAC crisis at least 1 year ago were included consecutively from 2013 to 2016. Contralateral eye was used as control. All patients underwent ophthalmic examination, RNFL imaging by SD-OCT, and SAP using Octopus 1-2-3. Results: 54 eyes (27 patients) were enrolled. [...] ABSTRACT Objective: To evaluate structural and visual field (VF) changes after ≥1 year of a single acute primary angle closure (APAC) attack using spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP). Methods: Patients with a single unilateral APAC crisis at least 1 year ago were included consecutively from 2013 to 2016. Contralateral eye was used as control. All patients underwent ophthalmic examination, RNFL imaging by SD-OCT, and SAP using Octopus 1-2-3. Results: 54 eyes (27 patients) were enrolled.


  • Glaucoma drainage devices

    by José Aloisio Massote, Victor Dias Massote Mourão Oliveira, Sebastião Cronemberger

    Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and [...] ABSTRACT Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and