NFNadia Falzone

Nadia Falzone

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nadia Falzone has a total of 135 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Equivalent physical dose (EPD) for improved precision in voxelized dosimetry

    by Elliot M. Abbott, Bleddyn Jones, Borivoj Vojnovic, Nadia Falzone, Adam Turner, Katherine A. Vallis

    Purpose: Equivalent dose in 2 Gy fractions (EQD2), based on the original biological effective dose (BED) equation, is frequently used to guide treatment in the clinic. This work addresses the limitations of EQD2 in the context of voxelized dosimetry, clarifies potential sources of confusion, and provides an alternative formulation for improved precision. Methods and Materials: The EQD2 formula was evaluated by a simple insertion of the EQD2 dose into the BED equation. The mathematically exact form of EQD2, referred to here as equivalent physical dose (EPD), was provided by solving the linear-quadratic model BED equation for dose using the quadratic formula. The EPD derivation was compared in terms of absolute error to the EQD2 derivation, which separates the Relative Effect term from the BED equation. Results: The EQD2 expression implicitly assumed a homogenous dose, demonstrating that its use in voxelized dosimetry can mislead. As an alternative formulation, EPD was shown to adhere more closely to the first principles of radiobiological modeling. An error analysis identified absolute errors from EQD2 sometimes in excess of 10%. Conclusions: Assumptions in the standard EQD2 equation are inappropriate in the context of voxelized dosimetry, where voxels within a structure, such as a target volume, may receive a dose that differs from the prescribed dose. Using EPD (or BED) instead of EQD2 would address these areas of confusion. Optimizing therapy according to biological properties in this way could provide enhanced and more reliable radiobiological input to radiotherapy treatment planning.

  • 9th international symposium on physical, molecular, cellular, and medical aspects of Auger processes: preface

    by Katherine A Vallis, Roger F. Martin, Nadia Falzone

    The 9th International Symposium on Physical, Molecular, Cellular, and Medical Aspects of Auger Processes took place from 22nd to 24th August 2019. This is a quadrennial event that has traditionally...


  • Open Access

    OpenDose: Open-Access Resource for Nuclear Medicine Dosimetry

    by Maxime Chauvin, Damian Borys, Francesca Botta, Pawel Bzowski, Jeremie Dabin, Ana Denis-Bacelar, Aurélie Desbrée, Nadia Falzone, Boon Lee, Andrea Mairiani, et al.

    Background: Radiopharmaceutical dosimetry depends on the localization in space and time of radioactive sources and requires the estimation of the amount of energy emitted by the sources deposited within targets. In particular, when computing resources are not accessible, this task can be carried out using precomputed tables of Specific Absorbed Fractions (SAFs) or S values based on dosimetric models. The OpenDose collaboration aims to generate and make freely available a range of dosimetric data and tools. Methods: OpenDose brings together resources and expertise from 18 international teams to produce and compare traceable dosimetric data using 6 of the most popular Monte Carlo codes in radiation transport (EGSnrc/EGS++, FLUKA, GATE, Geant4, MCNP/MCNPX and PENELOPE). SAFs are uploaded, together with their associated statistical uncertainties, in a relational database. S values are then calculated from mono-energetic SAFs, based on the radioisotope decay data presented in the International Commission on Radiological Protection (ICRP) publication 107. Results: The OpenDose collaboration produced SAFs for all source regions and targets combinations of the two ICRP 110 adult reference models. SAFs computed from the different Monte Carlo codes were in good agreement at all energies, with standard deviations below individual statistical uncertainties. Calculated S values were in good agreement with OLINDA 2 (commercial) and IDAC 2.1 (free) software. A dedicated website (www.opendose.org) has been developed to provide easy and open access to all data. Conclusion: The OpenDose website allows the display and download of SAFs and the corresponding S values for 1252 radionuclides. The OpenDose collaboration, open to new research teams, will extend data production to other dosimetric models and implement new free features, such as online dosimetric tools and patient-specific absorbed dose calculation software, together with educational resources.


  • Open Access

    Radiosensitivity of colorectal cancer to 90Y and the radiobiological implications for radioembolisation therapy

    by Boon Quan Lee, Elliot M Abbott, Sarah Able, James M Thompson, Mark A Hill, Christiana Kartsonaki, Katherine A Vallis, Nadia Falzone

    Approximately 50% of all colorectal cancer (CRC) patients will develop metastasis to the liver. 90Y selective internal radiation therapy (SIRT) is an established treatment for metastatic CRC. There is still a fundamental lack of understanding regarding the radiobiology underlying the dose response. This study was designed to determine the radiosensitivity of two CRC cell lines (DLD-1 and HT-29) to 90Y β − radiation exposure, and thus the relative effectiveness of 90Y SIRT in relation to external beam radiotherapy (EBRT). A 90Y-source dish was sandwiched between culture dishes to irradiate DLD-1 or HT-29 cells for a period of 6 d. Cell survival was determined by clonogenic assay. Dose absorbed per 90Y disintegration was calculated using the PENELOPE Monte Carlo code. PENELOPE simulations were benchmarked against relative dose measurements using EBT3 GAFchromic™ film. Statistical regression based on the linear-quadratic model was used to determine the radiosensitivity parameters and using R. These results were compared to radiosensitivity parameters determined for 6 MV clinical x-rays and 137Cs γ-ray exposure. Equivalent dose of EBRT in 2 Gy ( ) and 10 Gy ( ) fractions were derived for 90Y dose. HT-29 cells were more radioresistant than DLD-1 for all treatment modalities. Radiosensitivity parameters determined for 6 MV x-rays and 137Cs γ-ray were equivalent for both cell lines. The ratio for 90Y β −-particle exposure was over an order of magnitude higher than the other two modalities due to protraction of dose delivery. Consequently, an 90Y SIRT absorbed dose of 60 Gy equates to an of 28.7 and 54.5 Gy and an of 17.6 and 19.3 Gy for DLD-1 and HT-29 cell lines, respectively. We derived radiosensitivity parameters for two CRC cell lines exposed to 90Y β −-particles, 6 MV x-rays, and 137Cs γ-ray irradiation. These radiobiological parameters are critical to understanding the dose response of CRC lesions and ultimately informs the efficacy of 90Y SIRT relative to other radiation therapy modalities.


  • Clinical trials in molecular radiotherapy—Tribulations and Triumphs Report of the NCRI CTRad meeting held at the Lift Islington, 8 June 2018

    by Nadia Falzone, Rebecca Gregory, Matthew Aldridge, Samantha Ya Terry, Glenn Flux

    It has been almost a decade since the commentary Molecular radiotherapy — the radionuclide raffle? by Gaze and Flux (2010). The overarching feeling then was that no individual or organisation has taken up the challenge, nationally or internationally, of championing molecular targeted radionuclide therapy in all its aspects. Here, we report on the recent NCRI–CTRad (Clinical Trials in Molecular Radiotherapy–Tribulations and Triumphs) meeting, held in London on the 8 June 2018. The meeting was organized by the NCRI–CTRad to review the challenges and opportunities for clinical trials in molecular radiotherapy, particularly focussing on investigator-led trials that incorporate imaging and dosimetry, and to discuss how the community can move forward. This meeting was organised in conjunction with the British Nuclear Medicine Society and reflects the progress of Nuclear Medicine in the UK.


  • Open Access

    Targeted Radionuclide Therapy: New Advances for Improvement of Patient Management and Response

    by Javian Malcolm, Nadia Falzone, Boon Q. Lee, Katherine A. Vallis

    Compared to external beam radiotherapy, targeted radionuclide therapy (TRT) allows for systemic radiation treatment of metastatic lesions. Published work on recent strategies to improve patient management and response to TRT through individualising patient treatment, modifying treatment pharmacokinetics and increasing anticancer potency are discussed in this review, with a special focus on the application of clinically evaluated radiolabelled ligands and peptides in the treatment of neuroendocrine and prostate cancers.


  • Open Access

    Dosimetric evaluation of radionuclides for VCAM-1-targeted radionuclide therapy of early brain metastases

    by Nadia Falzone, Nicole L. Ackerman, Liset de la Fuente Rosales, Mario A. Bernal, Xiaoxuan Liu, Sarah Gja Peeters, Manuel Sarmiento Soto, Aurélien Corroyer-Dulmont, Myriam Bernaudin, Elisa Grimoin, et al.

    Brain metastases develop frequently in patients with breast cancer, and present a pressing therapeutic challenge. Expression of vascular cell adhesion molecule 1 (VCAM-1) is upregulated on brain endothelial cells during the early stages of metastasis and provides a target for the detection and treatment of early brain metastases. The aim of this study was to use a model of early brain metastasis to evaluate the efficacy of α-emitting radionuclides, 149Tb, 211At, 212Pb, 213Bi and 225Ac; β-emitting radionuclides, 90Y, 161Tb and 177Lu; and Auger electron (AE)-emitters 67Ga, 89Zr, 111In and 124I, for targeted radionuclide therapy (TRT).


  • Open Access

    Improved outcome of 131 I-mIBG treatment through combination with external beam radiotherapy in the SK-N-SH mouse model of neuroblastoma

    by Aurélien Corroyer-Dulmont, Nadia Falzone, Veerle Kersemans, James Thompson, Danny P. Allen, Sarah Able, Christiana Kartsonaki, Javian Malcolm, Paul Kinchesh, Mark A. Hill, et al.


  • Open Access

    An efficient and robust MRI-guided radiotherapy planning approach for targeting abdominal organs and tumours in the mouse

    by Veerle Kersemans, John S. Beech, Stuart Gilchrist, Paul Kinchesh, Philip D. Allen, James Thompson, Ana L. Gomes, Zenobia D’cOsta, Luke Bird, Iain D. C. Tullis, et al.

    Preclinical CT-guided radiotherapy platforms are increasingly used but the CT images are characterized by poor soft tissue contrast. The aim of this study was to develop a robust and accurate method of MRI-guided radiotherapy (MR-IGRT) delivery to abdominal targets in the mouse. A multimodality cradle was developed for providing subject immobilisation and its performance was evaluated. Whilst CT was still used for dose calculations, target identification was based on MRI. Each step of the radiotherapy planning procedure was validated initially in vitro using BANG gel dosimeters. Subsequently, MR-IGRT of normal adrenal glands with a size-matched collimated beam was performed. Additionally, the SK-N-SH neuroblastoma xenograft model and the transgenic KPC model of pancreatic ductal adenocarcinoma were used to demonstrate the applicability of our methods for the accurate delivery of radiation to CT-invisible abdominal tumours. The BANG gel phantoms demonstrated a targeting efficiency error of 0.56 ± 0.18 mm. The in vivo stability tests of body motion during MR-IGRT and the associated cradle transfer showed that the residual body movements are within this MR-IGRT targeting error. Accurate MR-IGRT of the normal adrenal glands with a size-matched collimated beam was confirmed by γH2AX staining. Regression in tumour volume was observed almost immediately post MR-IGRT in the neuroblastoma model, further demonstrating accuracy of x-ray delivery. Finally, MR-IGRT in the KPC model facilitated precise contouring and comparison of different treatment plans and radiotherapy dose distributions not only to the intra-abdominal tumour but also to the organs at risk. This is, to our knowledge, the first study to demonstrate preclinical MR-IGRT in intra-abdominal organs. The proposed MR-IGRT method presents a state-of-the-art solution to enabling robust, accurate and efficient targeting of extracranial organs in the mouse and can operate with a sufficiently high throughput to allow fractionated treatments to be given.


  • Absorbed dose evaluation of Auger electron-emitting radionuclides: impact of input decay spectra on dose point kernels and S -values

    by Nadia Falzone, Boon Q Lee, José M Fernández-Varea, Christiana Kartsonaki, Andrew E Stuchbery, Tibor Kibédi, Katherine A Vallis

    The aim of this study was to investigate the impact of decay data provided by the newly developed stochastic atomic relaxation model BrIccEmis on dose point kernels (DPKs - radial dose distribution around a unit point source) and S -values (absorbed dose per unit cumulated activity) of 14 Auger electron (AE) emitting radionuclides, namely 67 Ga, 80m Br, 89 Zr, 90 Nb, 99m Tc, 111 In, 117m Sn, 119 Sb, 123 I, 124 I, 125 I, 135 La, 195m Pt and 201 Tl. Radiation spectra were based on the nuclear decay data from the medical internal radiation dose (MIRD) RADTABS program and the BrIccEmis code, assuming both an isolated-atom and condensed-phase approach. DPKs were simulated with the PENELOPE Monte Carlo (MC) code using event-by-event electron and photon transport. S -values for concentric spherical cells of various sizes were derived from these DPKs using appropriate geometric reduction factors. The number of Auger and Coster–Kronig (CK) electrons and x-ray photons released per nuclear decay (yield) from MIRD-RADTABS were consistently higher than those calculated using BrIccEmis . DPKs for the electron spectra from BrIccEmis were considerably different from MIRD-RADTABS in the first few hundred nanometres from a point source where most of the Auger electrons are stopped. S -values were, however, not significantly impacted as the differences in DPKs in the sub-micrometre dimension were quickly diminished in larger dimensions. Overestimation in the total AE energy output by MIRD-RADTABS leads to higher predicted energy deposition by AE emitting radionuclides, especially in the immediate vicinity of the decaying radionuclides. This should be taken into account when MIRD-RADTABS data are used to simulate biological damage at nanoscale dimensions.