MBMario Berth

Mario Berth

*This is an algorithmically generated author record based on publicly available information.

Mario Berth has a total of 221 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nationwide Harmonization Effort for Semi-Quantitative Reporting of SARS-CoV-2 PCR Test Results in Belgium

    by Lize Cuypers, Jannes Bode, Kurt Beuselinck, Lies Laenen, Klaas Dewaele, Reile Janssen, Arnaud Capron, Yves Lafort, Henry Paridaens, Bertrand Bearzatto, et al.

    From early 2020, a high demand for SARS-CoV-2 tests was driven by several testing indications, including asymptomatic cases, resulting in the massive roll-out of PCR assays to combat the pandemic. Considering the dynamic of viral shedding during the course of infection, the demand to report cycle threshold (Ct) values rapidly emerged. As Ct values can be affected by a number of factors, we considered that harmonization of semi-quantitative PCR results across laboratories would avoid potential divergent interpretations, particularly in the absence of clinical or serological information. A proposal to harmonize reporting of test results was drafted by the National Reference Centre (NRC) UZ/KU Leuven, distinguishing four categories of positivity based on RNA copies/mL. Pre-quantified control material was shipped to 124 laboratories with instructions to setup a standard curve to define thresholds per assay. For each assay, the mean Ct value and corresponding standard deviation was calculated per target gene, for the three concentrations (107, 105 and 103 copies/mL) that determine the classification. The results of 17 assays are summarized. This harmonization effort allowed to ensure that all Belgian laboratories would report positive PCR results in the same semi-quantitative manner to clinicians and to the national database which feeds contact tracing interventions.


  • Interference of anti-streptavidin antibodies in immunoassays: a very rare phenomenon or a more common finding?

    by Nick Verougstraete, Mario Berth, Mario Vaneechoutte, Joris Delanghe, Nico Callewaert

    Background: Anti-streptavidin antibodies (ASA) may cause analytical interference on certain immunoassay platforms. Streptavidin is purified from the non-pathogenic Streptomyces avidinii soil bacterium. In contrast to interference with biotin, ASA interference is supposed to be much rarer. In-depth studies on this topic are lacking. Therefore, we carried out an analysis toward the prevalence and the possible underlying cause of this interference. Methods: Anti-streptavidin (AS)-immunoglobulin G (IgG) and AS-IgM concentrations were determined on multiple samples from two patients with ASA interference and on 500 random samples. On a subset of 100 samples, thyroid-stimulating hormone (TSH) was measured on a Cobas analyzer before and after performing a neutralization protocol which removes ASA. The relationship between the ratio of TSH after neutralization/TSH before neutralization and the ASA concentration was evaluated. Subsequently, an extract of S. avidinii colonies was analyzed using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and immunoblotting. Results: A positive correlation between AS-IgM concentrations and TSH ratio was obtained. Eight samples out of 500 exceeded the calculated AS-IgM cut-off value. In comparison to the AS-IgM concentrations in the population, titers from the two described cases clearly stood out. The isolated cases represent the end of a broader spectrum as there is a continuum of AS-IgM reactivity in the general population. We could not observe any differences in the immunoblot patterns between the cases and controls, which may indicate the general presence of ASA in the population. Conclusions: Interference due to ASA is more prevalent than initially thought and is caused by IgM antibodies.


  • Physiological changes during first encounters and their role in determining the perceived interaction quality

    by Konrad Rudnicki, Carolyn Declerck, Charlotte De Backer, Mario Berth

    What determines if the first interaction between strangers will be a pleasant experience? We conducted an experiment to investigate the extent to which the perceived quality of an interaction is influenced by conversation content and context, and we document the physiological changes that are likely to play a role in establishing rapport. Females who did not know each other met in pairs and conducted a gossip- or creativity task, either face-to-face or online. The conversation content had no effect on the quality of online interactions. However in the face-to-face condition gossip was associated with better interaction quality. Tonic electrodermal activity steadily declined throughout the interaction, while phasic electrodermal activity first peaked and then returned to baseline. Neither were related to perceived interaction quality. Heart rate variability (HRV) dropped at first but then remained stable. A smaller drop in HRV drop corresponded to higher ratings of rapport and liking. Together these results suggest that gossip can improve the quality of a face-to-face interaction between strangers, and support the conjecture that parasympathetic activity is a marker of human openness to social engagement.


  • Short communication: Sensitivity of estrus alerts and relationship with timing of the luteinizing hormone surge

    by Ines Adriaens, Wouter Saeys, Chris Lamberigts, Mario Berth, Katleen Geerinckx, Jo Leroy, Bart De Ketelaere, Ben Aernouts

    Both the sensitivity of an estrus detection system and the consistency of alarms relative to ovulation determine its value for a farmer. The objective of this study was to compare an activity-based system and a milk progesterone-based system for their ability to detect estrus reliably, and to investigate how their alerts are linked to the time of the LH surge preceding ovulation. The study was conducted on an experimental research farm in Flanders, Belgium. The activity alerts were generated by a commercial activity meter (ActoFIT, DeLaval, Tumba, Sweden), and milk progesterone was measured using a commercial ELISA kit. Sensitivity and positive predictive value of both systems were calculated based on 35 estrus periods over 43 d. Blood samples were taken for determination of the LH surge, and the intervals between timing of the alerts and the LH surge were investigated based on their range and standard deviation (SD). Activity alerts had a sensitivity of 80% and a positive predictive value of 65.9%. Alerts were detected from 39 h before until 8 h after the LH surge (range: 47 h, SD: 16 h). Alerts based on milk progesterone were obtained from a recently developed monitoring algorithm using a mathematical model and synergistic control. All estruses were correctly identified by this algorithm, and the LH surge followed, on average, 62 h later. Using the mathematical model, model-based indicators for the estimation of ovulation time can be calculated. Depending on which model-based indicator was used, ranges of 33 to 35 h and SD of about 11 h were obtained. Because detection of the LH surge was very labor intensive, only a limited number of potential estrus periods could be studied.


  • Open Access

    Impact of particulate matter on mothers and babies in Antwerp (IPANEMA): a prospective cohort study on the impact of pollutants and particulate matter in pregnancy

    by Lena Van Den Eeden, Nathalie Lambrechts, Veerle Verheyen, Mario Berth, Greet Schoeters, Yves Jacquemyn

    Introduction Air pollution is a hot topic and is known to cause multiple health issues. Especially pregnant women seem to be vulnerable to environmental issues. There are data suggesting that exposure contributes to hypertensive disorders. This study aims to evaluate the effects of exposure to particulate matter (PM) and outdoor air pollutants on the clinical pregnancy outcome for mother and child and to determine which biochemical changes in maternal, placental and cord blood best explain this effect. Methods and analysis This study is a prospective cohort study. We aim to recruit 200 pregnant women. The outcome measurements will include maternal parameters, labour parameters and neonatal parameters. Multiple samples will be analysed such as maternal urine samples (8-oxo-deoxyguanosine), maternal blood samples (routine blood sampling, biomarkers of pre-eclampsia and transcript markers), maternal hair samples, neonatal blood samples (transcript markers) combined with extensive questionnaires. Ethics and dissemination We obtain informed consent from each participant prior to enrolment in the study. The study has received approval by the Ethical Committee of the Antwerp University Hospital (14/40/411). IPANEMA is the first prospective study to assess the impact of PM on mothers and babies in Antwerp, Belgium. Findings from this study will contribute to improve knowledge on the impact of exposure to air pollution on mothers and babies and will also define biomarkers as predictors for pregnant women at risk. Trial registration ClinicalTrials.gov: 14/40/411. Registered 22-10-2015.


  • Anti-streptavidin IgG antibody interference in anti-cyclic citrullinated peptide (CCP) IgG antibody assays is a rare but important cause of false-positive anti-CCP results

    by Mario Berth, Sofie Willaert, Carol De Ridder

    Background: The detection of anti-cyclic citrullinated peptide (anti-CCP) IgG antibodies in blood is mainly used for the diagnosis of rheumatoid arthritis. Falsely elevated anti-CCP IgG antibodies due to anti-streptavidin IgG antibodies were suspected in our laboratory.Methods: In this study, we evaluated, in a standardized approach, the prevalence of anti-streptavidin IgG antibodies in a primary care setting and the effect of anti-streptavidin IgG antibodies on anti-CCP IgG assays from three different important commercial manufacturers (Abbott, Roche Diagnostics, Thermo Fisher Scientific). Three different populations were consecutively and prospectively studied: serum samples from 1000 ambulatory patients, 286 serum samples from patients for which anti-CCP was requested and 89 serum samples from patients which had previously given a positive anti-CCP result on Architect®i2000.Results: The frequency of confirmed anti-streptavidin IgG-positive samples detected in this study was 0.6% (8/1375). Anti-CCP IgG was determined on the eight samples with confirmed anti-streptavidin IgG antibodies: with the Cobas®method, seven positive anti-CCP results were observed and five positive anti-CCP results with the Architect®method. No positive anti-CCP IgG results were obtained with the EliA™ method. Rheumatoid factor was negative in these eight samples.Conclusions: Anti-streptavidin IgG antibodies rarely cause false-positive results in some anti-CCP assays. However, despite being an infrequent assay problem, it could possibly lead to diagnostic confusion or even an incorrect diagnosis of rheumatoid arthritis.


  • The importance of detecting anti-DFS70 in routine clinical practice: comparison of different care settings

    by Carolien Bonroy, Sofie Schouwers, Mario Berth, Muriel Stubbe, Yves Piette, Ilse Hoffman, Katrien Devreese, Lieve Van Hoovels

    Background: Screening for antinuclear antibodies by indirect immunofluorescence (ANA-IIF) is essential in the diagnostic workup of ANA-associated autoimmune rheumatic diseases (AARDs). However, also healthy individuals may test positive, making the interpretation challenging. Recent reports suggest that dense fine speckled 70 antibodies (anti-DFS70) may facilitate this challenge. Here, we investigate their clinical importance based on data from four Belgian laboratories (one primary, two secondary and one tertiary care).Methods: At least one specific DFS70 assay (DFS70 IgG ELISA or lineblot [Euroimmun, full length antigen] and/or DFS70 IgG CLIA [Inova Diagnostics, truncated antigen]) was performed on four consecutive cohorts of homogeneous-like ANA-IIF samples (n=697). Co-occurrence with AARD-specific ANA and clinical information were documented in the anti-DFS70-positive samples.Results: Using a combination of solid phase techniques, we found between 7.6% and 26% anti-DFS70 in the different cohorts. Focusing on anti-DFS70 CLIA-positive samples without co-occurrence of AARD-specific ANA, we observed a trend towards lower frequency in tertiary (8% [p=0.0786]) and secondary care (12% [p=0.1275] and 6% [p<0.001]) compared to primary care (21%). Moreover, in this specific subpopulation, AARD was less frequent (0%–50% compared to 6%–77% in the total anti-DFS70-positive group).Conclusions: Anti-DFS70 prevalence depends on the applied assay and care setting. Our data suggest that, for an ANA-IIF-positive patient, it is rather the absence of AARD-associated ANA and clinical symptoms that contribute to the exclusion of AARD than the presence of anti-DFS70. Nevertheless, isolated anti-DFS70 helps to clarify positive ANA-IIF results, especially if pretest probability for AARD is low.


  • Open Access

    Interpretive Summary. Heat detection alerts and LH surge. Adriaens

    by Ines Adriaens, Wouter Saeys, Chris Lamberigts, Mario Berth, Katleen Geerinckx, Jo Leroy, Bart De Ketelaere, Ben Aernouts

    Both estrus detection and timely insemination are important factors in optimizing fertility management. The latter is dependent on ovulation time, which is preceded by the LH surge. The performance of an estrus detection system based on activity and based on milk progesterone was evaluated and the timing of the alerts was contrasted against the moment of the LH surge. Activity alerts had a sensitivity of 83% and a positive predictive value of 66%; the LH surge followed average 9.4 ± 16.1 hours later. Using milk progesterone, one can reliably detect luteolysis, which is followed by the LH surge after 62 ± 12 hours.