Ion Evangelos Stamatelatos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ion Evangelos Stamatelatos has a total of 114 co-authors. Here are the top co-authors by number of shared publications:
- Theodora Vasilopoulou
INRASTES, NCSR "Demokritos
7 shared publications T. Vasilopoulou
5 shared publicationsJ. Kalef-Ezra
Medical School, University of Ioannina
4 shared publicationsJet Contributors
4 shared publications- Marilia I. Savva
Institute of Nuclear and Radiological Sciences, Technology, Energy and Safety, N.C.S.R. “Demokritos”, Aghia Paraskevi, 15310 Athens, Greece
4 shared publications - Antigoni Kalamara
Department of Physics, National Technical University of Athens, Zografou Campus, 15780 Athens, Greece
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (9) , 095011
Neutron measurements with VERDI detectors in the long term irradiation station at JET tokamak during Deuterium–Tritium operation
The VERDI detector is a passive neutron detector using the multi-foil activation technique to measure neutron fluence in extreme fusion conditions. It features a low-activation capsule that contains a defined concentration of metallic elements. The robustness of the detector is ensured by the capsule material, while neutron detection relies on activation of the metallic elements. Post-irradiation gamma spectrometry combined with computational unfolding enables reconstruction of the neutron fluence and energy spectrum. This study reviews the development of the VERDI detector and reports the first deployment of VERDI detectors in an operational Deuterium–Tritium fusion environment in the long-term irradiation station of Joint European Torus tokamak during the DTE2 campaign, featuring a neutron spectrum representative of future fusion devices such as ITER and DEMO. The results provide benchmarks for validating neutronic simulations and nuclear data, supporting the design optimization and safety assessment of future fusion power plants.
- 1 September 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (9) , 095011
Open AccessNeutron measurements with VERDI detectors in the long term irradiation station at JET tokamak during Deuterium–Tritium operation
The VERDI detector is a passive neutron detector using the multi-foil activation technique to measure neutron fluence in extreme fusion conditions. It features a low-activation capsule that contains a defined concentration of metallic elements. The robustness of the detector is ensured by the capsule material, while neutron detection relies on activation of the metallic elements. Post-irradiation gamma spectrometry combined with computational unfolding enables reconstruction of the neutron fluence and energy spectrum. This study reviews the development of the VERDI detector and reports the first deployment of VERDI detectors in an operational Deuterium–Tritium fusion environment in the long-term irradiation station of Joint European Torus tokamak during the DTE2 campaign, featuring a neutron spectrum representative of future fusion devices such as ITER and DEMO. The results provide benchmarks for validating neutronic simulations and nuclear data, supporting the design optimization and safety assessment of future fusion power plants.
- Open Access
- 24 February 2026
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 32, 16-19
Simulations for Optimization of Proton Dose Delivery using the Advanced Markus Chamber
The Advanced Markus chamber is a vented, plane-parallel ionization chamber widely used in proton dosimetry, particularly in cases involving narrow spread-out Bragg peaks or steep depth-dose gradients. As part of the NuCapCure project, a series of in vitro and animal model irradiation experiments will be conducted to evaluate the efficacy of novel radiosensitive compounds designed to enhance the cancer cell-killing potential of proton therapy. To support these experiments, Monte Carlo simulations were carried out using the MCNP 6.1 code to model the irradiation setup at the Oslo Cyclotron Laboratory (OCL) that employs the MC-35 Scanditronix AB cyclotron. The computational model included the 16 MeV proton source, a tungsten filter, a beam monitor, and the Advanced Markus chamber. Special attention was paid to the effect of the chamber’s entrance window, as it influences the location of the proton Bragg peak. The results of this study allow the optimal positioning of both the Markus chamber and the biological samples, thereby maximizing dose delivery during proton irradiation experiments.
- 24 February 2026
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 32, 16-19
Open AccessSimulations for Optimization of Proton Dose Delivery using the Advanced Markus Chamber
The Advanced Markus chamber is a vented, plane-parallel ionization chamber widely used in proton dosimetry, particularly in cases involving narrow spread-out Bragg peaks or steep depth-dose gradients. As part of the NuCapCure project, a series of in vitro and animal model irradiation experiments will be conducted to evaluate the efficacy of novel radiosensitive compounds designed to enhance the cancer cell-killing potential of proton therapy. To support these experiments, Monte Carlo simulations were carried out using the MCNP 6.1 code to model the irradiation setup at the Oslo Cyclotron Laboratory (OCL) that employs the MC-35 Scanditronix AB cyclotron. The computational model included the 16 MeV proton source, a tungsten filter, a beam monitor, and the Advanced Markus chamber. Special attention was paid to the effect of the chamber’s entrance window, as it influences the location of the proton Bragg peak. The results of this study allow the optimal positioning of both the Markus chamber and the biological samples, thereby maximizing dose delivery during proton irradiation experiments.
- 9 April 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Experimental validation of transmutation products calculations in neutron irradiated tungsten
- 9 April 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 215
Experimental validation of transmutation products calculations in neutron irradiated tungsten
- Open Access
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 189-194
Microdosimetric Modelling of Neutron Capture Therapy Effectiveness
Monte Carlo simulations were carried out using the MCNP 6.1 code to predict the energy deposition at microscopic level in in vitro Neutron Capture Therapy studies. Irradiations with neutron beams of energies from 25 meV to 14.2 MeV of small spherical targets loaded with either 1000 ppm natB (200 ppm 10B) or natGd (156 ppm 157Gd) and located at the center of a small phantom were simulated. ENDF/B-VII.1 and TENDL-2017 libraries, as well as INCL4/ABLA and Bertini models were tested using published experimental data as benchmark, i.e. a spherical proportional counter that simulated a 1 μm in diameter tissue equivalent site irradiated with 13.9 MeV neutrons. The methodology, as developed, was applied to assess the microdistribution spectra to the target in terms of yd(y), yF, yD and the kerma to flux ratio for the prediction of the biological response of in vitro cells irradiations.
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 189-194
Open AccessMicrodosimetric Modelling of Neutron Capture Therapy Effectiveness
Monte Carlo simulations were carried out using the MCNP 6.1 code to predict the energy deposition at microscopic level in in vitro Neutron Capture Therapy studies. Irradiations with neutron beams of energies from 25 meV to 14.2 MeV of small spherical targets loaded with either 1000 ppm natB (200 ppm 10B) or natGd (156 ppm 157Gd) and located at the center of a small phantom were simulated. ENDF/B-VII.1 and TENDL-2017 libraries, as well as INCL4/ABLA and Bertini models were tested using published experimental data as benchmark, i.e. a spherical proportional counter that simulated a 1 μm in diameter tissue equivalent site irradiated with 13.9 MeV neutrons. The methodology, as developed, was applied to assess the microdistribution spectra to the target in terms of yd(y), yF, yD and the kerma to flux ratio for the prediction of the biological response of in vitro cells irradiations.
- Open Access
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 215-218
Absorbed Dose Distribution in Boron Neutron Capture Therapy for the Treatment of Brain Cancer
Boron Neutron Capture Therapy (BNCT) is a promising re-emerging therapeutic approach for brain tumors, such as glioblastoma multiforme, where conventional treatments have limited efficacy. BNCT is based on neutron irradiation of tumors to selectively kill malignant cells that have accumulated boron compounds with high LET particles produced from the thermal neutron absorption reaction in 10B. Two sets of simulations were performed using the MCNP6.1 code. The first involves the study of the dose components as a function of depth in a cylindrical head phantom consisting of water. The second one deals with the estimation of macroscopic dosimetric quantities to the critical structures in the voxelized Zubal anthropomorphic head/neck phantom. Simulations were performed for different neutron energy spectra, beam radii, as well as boron concentrations in the tumor and the surrounding healthy tissues. The findings contribute to the optimized irradiation of the target in BNCT, while sparing of the patient’s surrounding healthy tissues.
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 215-218
Open AccessAbsorbed Dose Distribution in Boron Neutron Capture Therapy for the Treatment of Brain Cancer
Boron Neutron Capture Therapy (BNCT) is a promising re-emerging therapeutic approach for brain tumors, such as glioblastoma multiforme, where conventional treatments have limited efficacy. BNCT is based on neutron irradiation of tumors to selectively kill malignant cells that have accumulated boron compounds with high LET particles produced from the thermal neutron absorption reaction in 10B. Two sets of simulations were performed using the MCNP6.1 code. The first involves the study of the dose components as a function of depth in a cylindrical head phantom consisting of water. The second one deals with the estimation of macroscopic dosimetric quantities to the critical structures in the voxelized Zubal anthropomorphic head/neck phantom. Simulations were performed for different neutron energy spectra, beam radii, as well as boron concentrations in the tumor and the surrounding healthy tissues. The findings contribute to the optimized irradiation of the target in BNCT, while sparing of the patient’s surrounding healthy tissues.
- Open Access
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 207-210
Neutron dosimetry at HK-1 beam line of LVR-15 reactor for biomedical sample irradiations
The HK-1 neutron beam line at the LVR-15 reactor in ÚJV Řež, Czech Republic, was used for in vitro cell studies carried out in the framework of the FRINGE project, aiming on the development of a novel neutron capture therapy technique using Gd containing compounds. The neutron fluence rate close the HK-1 beam exit was experimentally assessed. Neutron fluence rate data were combined with Monte Carlo simulations performed using the MCNP 6.1 code, to model a well-type vial containing a thin layer of cells, with and without Gd, as well as the supporting media. Aim of the study was to evaluate the energy deposited by the neutrons in the cell monolayers and delineate the contribution of the various dose components in an attempt to interpretate the findings of the in vitro studies.
- 31 July 2024
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 30, 207-210
Open AccessNeutron dosimetry at HK-1 beam line of LVR-15 reactor for biomedical sample irradiations
The HK-1 neutron beam line at the LVR-15 reactor in ÚJV Řež, Czech Republic, was used for in vitro cell studies carried out in the framework of the FRINGE project, aiming on the development of a novel neutron capture therapy technique using Gd containing compounds. The neutron fluence rate close the HK-1 beam exit was experimentally assessed. Neutron fluence rate data were combined with Monte Carlo simulations performed using the MCNP 6.1 code, to model a well-type vial containing a thin layer of cells, with and without Gd, as well as the supporting media. Aim of the study was to evaluate the energy deposited by the neutrons in the cell monolayers and delineate the contribution of the various dose components in an attempt to interpretate the findings of the in vitro studies.
- Open Access
- 5 May 2023
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 29, 167-170
Compton Suppression System performance evaluation for measurement of VERDI activation detectors
The VERDI detector was developed for accurate neutron measurements in the plasma-facing modules of a tokamak. It comprises a low activation capsule, capable to withstand the harsh conditions of the fusion environment, containing a defined mass of metallic foils. The neutron fluence and energy spectrum are derived by analysis of the gamma lines produced by neutron activation of the metallic elements. In this work, the use of a Compton Suppression System (CSS) is investigated aiming to enhance the sensitivity of VERDI detector analysis. The CSS consists of a 40% HPGe primary detector coupled to a set of NaI secondary detectors. The apparatus was set to discard signals simultaneously recorded on both primary and secondary detectors, thus lowering the Compton continuum. The VERDI detectors were irradiated at the Joint European Torus (JET) during the 2019 Deuterium-Deuterium (DD) campaign. The CSS performance was studied by calculating peak and continuum suppression factors. The advantage introduced by Compton suppressed gamma spectrometry for each nuclide of interest is explored and the suitability of this system for VERDI detector measurements is discussed.
- 5 May 2023
- Published by National Documentation Centre (EKT) in HNPS Advances in Nuclear Physics
- Vol. 29, 167-170
Open AccessCompton Suppression System performance evaluation for measurement of VERDI activation detectors
The VERDI detector was developed for accurate neutron measurements in the plasma-facing modules of a tokamak. It comprises a low activation capsule, capable to withstand the harsh conditions of the fusion environment, containing a defined mass of metallic foils. The neutron fluence and energy spectrum are derived by analysis of the gamma lines produced by neutron activation of the metallic elements. In this work, the use of a Compton Suppression System (CSS) is investigated aiming to enhance the sensitivity of VERDI detector analysis. The CSS consists of a 40% HPGe primary detector coupled to a set of NaI secondary detectors. The apparatus was set to discard signals simultaneously recorded on both primary and secondary detectors, thus lowering the Compton continuum. The VERDI detectors were irradiated at the Joint European Torus (JET) during the 2019 Deuterium-Deuterium (DD) campaign. The CSS performance was studied by calculating peak and continuum suppression factors. The advantage introduced by Compton suppressed gamma spectrometry for each nuclide of interest is explored and the suitability of this system for VERDI detector measurements is discussed.
- 21 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 191
Application of VERDI detectors for ITER materials activation product inventory characterization
- 21 February 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 191
Application of VERDI detectors for ITER materials activation product inventory characterization
- 6 December 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 104 (6) , 064603
Cross-section measurements of the reaction at neutron energies higher than 17 MeVIn the present work the cross section of the reaction ( MeV) was measured at neutron beam energies above 17 MeV: 17.1, 18.1, and 19.0 MeV. The irradiations were performed at the 5.5-MV tandem accelerator of the Institute of Nuclear and Particle Physics at N.C.S.R. “Demokritos”, where quasi-monoenergetic neutron beams were produced via the reaction. The cross-section measurements were performed by means of the activation technique relative to the reference reaction. Within the present work the experimental study is framed by theoretical calculations performed via the talys code (version 1.95).- 6 December 2021
- Published by American Physical Society (APS) in Physical Review C
- Vol. 104 (6) , 064603
Cross-section measurements of the reaction at neutron energies higher than 17 MeVIn the present work the cross section of the reaction ( MeV) was measured at neutron beam energies above 17 MeV: 17.1, 18.1, and 19.0 MeV. The irradiations were performed at the 5.5-MV tandem accelerator of the Institute of Nuclear and Particle Physics at N.C.S.R. “Demokritos”, where quasi-monoenergetic neutron beams were produced via the reaction. The cross-section measurements were performed by means of the activation technique relative to the reference reaction. Within the present work the experimental study is framed by theoretical calculations performed via the talys code (version 1.95).- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2658-2662
Neutron spectrum unfolding for the development of a novel neutron detector for fusion
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2658-2662
Neutron spectrum unfolding for the development of a novel neutron detector for fusion