Anthony McIntyre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anthony McIntyre has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Fergus Vincent Gleeson
Mayo Clinic, Rochester, United States of America
14 shared publications - Simon Clark
Public Health England, Microbiology Services, Porton Down, Salisbury, Wiltshire, United Kingdom
8 shared publications - Sally Sharpe
UK Health Security Agency, Porton Down, Wiltshire SP4 0JG, UK
6 shared publications - Andrew D. White
Research and Evaluation, UK Health Security Agency
5 shared publications A. Williams
Public Health England, Porton Down, Wiltshire, SP4 0JG, UK
4 shared publications- Ozkan Doganay
Department of Physics, Ryerson University, Toronto, Canada
4 shared publications
Latest Publications
- Open Access
- 6 November 2025
- Published by Elsevier in Radiography
- Vol. 32 (1) , 103214
Clinical and MRI variables in decision support systems for prostate MRI: A systematic review of decision support tools, nomograms, and risk models
- 6 November 2025
- Published by Elsevier in Radiography
- Vol. 32 (1) , 103214
Open AccessClinical and MRI variables in decision support systems for prostate MRI: A systematic review of decision support tools, nomograms, and risk models
- Top Cited Papers
- 24 May 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 709-717
Lung Abnormalities Detected with Hyperpolarized 129Xe MRI in Patients with Long COVID
Hyperpolarized xenon 129 MRI and total lung diffusion capacity for carbon monoxide demonstrate significantly impaired gas transfer in non-hospitalized post-COVID-19 condition participants with norm... Background Post-Covid-19 condition describes symptoms following COVID-19 infection after four weeks. Symptoms are wide-ranging but breathlessness is common. Purpose The purpose of this study was to...
- 24 May 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 709-717
Top Cited PapersLung Abnormalities Detected with Hyperpolarized 129Xe MRI in Patients with Long COVID
Hyperpolarized xenon 129 MRI and total lung diffusion capacity for carbon monoxide demonstrate significantly impaired gas transfer in non-hospitalized post-COVID-19 condition participants with norm... Background Post-Covid-19 condition describes symptoms following COVID-19 infection after four weeks. Symptoms are wide-ranging but breathlessness is common. Purpose The purpose of this study was to...
- Open Access
- 4 January 2021
- Published by Springer Nature in npj Vaccines
- Vol. 6 (1) , 1-10
MTBVAC vaccination protects rhesus macaques against aerosol challenge with M. tuberculosis and induces immune signatures analogous to those observed in clinical studies
A single intradermal vaccination with MTBVAC given to adult rhesus macaques was well tolerated and conferred a significant improvement in outcome following aerosol exposure to M. tuberculosis compared to that provided by a single BCG vaccination. Vaccination with MTBVAC resulted in a significant reduction in M. tuberculosis infection-induced disease pathology measured using in vivo medical imaging, in gross pathology lesion counts and pathology scores recorded at necropsy, the frequency and severity of pulmonary granulomas and the frequency of recovery of viable M. tuberculosis from extrapulmonary tissues following challenge. The immune profiles induced following immunisation with MTBVAC reflect those identified in human clinical trials of MTBVAC. Evaluation of MTBVAC- and TB peptide-pool-specific T-cell cytokine production revealed a predominantly Th1 response from poly- (IFN-γ+TNF-α+IL2+) and multi-(IFN-γ+TNF-α+) functional CD4 T cells, while only low levels of Th22, Th17 and cytokine-producing CD8 T-cell populations were detected together with low-level, but significant, increases in CFP10-specific IFN-γ secreting cells. In this report, we describe concordance between immune profiles measured in clinical trials and a macaque pre-clinical study demonstrating significantly improved outcome after M. tuberculosis challenge as evidence to support the continued development of MTBVAC as an effective prophylactic vaccine for TB vaccination campaigns.
- 4 January 2021
- Published by Springer Nature in npj Vaccines
- Vol. 6 (1) , 1-10
Open AccessMTBVAC vaccination protects rhesus macaques against aerosol challenge with M. tuberculosis and induces immune signatures analogous to those observed in clinical studies
A single intradermal vaccination with MTBVAC given to adult rhesus macaques was well tolerated and conferred a significant improvement in outcome following aerosol exposure to M. tuberculosis compared to that provided by a single BCG vaccination. Vaccination with MTBVAC resulted in a significant reduction in M. tuberculosis infection-induced disease pathology measured using in vivo medical imaging, in gross pathology lesion counts and pathology scores recorded at necropsy, the frequency and severity of pulmonary granulomas and the frequency of recovery of viable M. tuberculosis from extrapulmonary tissues following challenge. The immune profiles induced following immunisation with MTBVAC reflect those identified in human clinical trials of MTBVAC. Evaluation of MTBVAC- and TB peptide-pool-specific T-cell cytokine production revealed a predominantly Th1 response from poly- (IFN-γ+TNF-α+IL2+) and multi-(IFN-γ+TNF-α+) functional CD4 T cells, while only low levels of Th22, Th17 and cytokine-producing CD8 T-cell populations were detected together with low-level, but significant, increases in CFP10-specific IFN-γ secreting cells. In this report, we describe concordance between immune profiles measured in clinical trials and a macaque pre-clinical study demonstrating significantly improved outcome after M. tuberculosis challenge as evidence to support the continued development of MTBVAC as an effective prophylactic vaccine for TB vaccination campaigns.
- 26 March 2020
- Published by SAGE Publications in Laboratory Animals
- Vol. 54 (4) , 386-390
Use of high frequency jet ventilation as a refinement for imaging macaques with respiratory disease
Imaging is used in human medicine to diagnose disease and monitor treatment efficacy. Computed tomography (CT) positron emission tomography (PET) and magnetic resonance (MR) are applied to animal models of infectious diseases to increase data quality, enhance their relevance to the clinical situation, and to address ethical issues through reduction of numbers and refinement of study designs. The time required for collection of MR and PET-CT scans means that normal breathing produces motion artefacts that can render images unacceptable. We report, for the first time, the use of high frequency jet ventilation (HFJV) for respiratory management during imaging of macaques. HFJV enables continuous gaseous exchange, resulting in cessation of spontaneous breathing motion thus providing a motionless field without the potential stresses induced by repeated breath-hold strategies.
- 26 March 2020
- Published by SAGE Publications in Laboratory Animals
- Vol. 54 (4) , 386-390
Use of high frequency jet ventilation as a refinement for imaging macaques with respiratory disease
Imaging is used in human medicine to diagnose disease and monitor treatment efficacy. Computed tomography (CT) positron emission tomography (PET) and magnetic resonance (MR) are applied to animal models of infectious diseases to increase data quality, enhance their relevance to the clinical situation, and to address ethical issues through reduction of numbers and refinement of study designs. The time required for collection of MR and PET-CT scans means that normal breathing produces motion artefacts that can render images unacceptable. We report, for the first time, the use of high frequency jet ventilation (HFJV) for respiratory management during imaging of macaques. HFJV enables continuous gaseous exchange, resulting in cessation of spontaneous breathing motion thus providing a motionless field without the potential stresses induced by repeated breath-hold strategies.
- Open Access
- 4 September 2019
- Published by Springer Nature in European Radiology
- Vol. 30 (2) , 1145-1155
Delayed ventilation assessment using fast dynamic hyperpolarised Xenon-129 magnetic resonance imaging
Objectives To investigate the use of a fast dynamic hyperpolarised 129Xe ventilation magnetic resonance imaging (DXeV-MRI) method for detecting and quantifying delayed ventilation in patients with chronic obstructive pulmonary disease (COPD). Methods Three male participants (age range 31–43) with healthy lungs and 15 patients (M/F = 12:3, age range = 48–73) with COPD (stages II–IV) underwent spirometry tests, quantitative chest computed tomography (QCT), and DXeV-MRI at 1.5-Tesla. Regional delayed ventilation was captured by measuring the temporal signal change in each lung region of interest (ROI) in comparison to that in the trachea. In addition to its qualitative assessment through visual inspection by a clinical radiologist, delayed ventilation was quantitatively captured by calculating a covariance measurement of the lung ROI and trachea signals, and quantified using both the time delay, and the difference between the integrated areas covered by the signal-time curves of the two signals. Results Regional temporal ventilation, consistent with the expected physiological changes across a free breathing cycle, was demonstrated with DXeV-MRI in all patients. Delayed ventilation was observed in 13 of the 15 COPD patients and involved variable lung ROIs. This was in contrast to the control group, where no delayed ventilation was demonstrated (p = 0.0173). Conclusions DXeV-MRI offers a non-invasive way of detecting and quantifying delayed ventilation in patients with COPD, and provides physiological information on regional pulmonary function during a full breathing cycle. Key Points • Dynamic xenon MRI allows for the non-invasive detection and measurement of delayed ventilation in COPD patients. • Dynamic xenon MRI during a free breathing cycle can provide unique information about pulmonary physiology and pulmonary disease pathophysiology. • With further validation, dynamic xenon MRI could offer a non-invasive way of measuring collateral ventilation which can then be used to guide lung volume reduction therapy (LVRT) for certain COPD patients.
- 4 September 2019
- Published by Springer Nature in European Radiology
- Vol. 30 (2) , 1145-1155
Open AccessDelayed ventilation assessment using fast dynamic hyperpolarised Xenon-129 magnetic resonance imaging
Objectives To investigate the use of a fast dynamic hyperpolarised 129Xe ventilation magnetic resonance imaging (DXeV-MRI) method for detecting and quantifying delayed ventilation in patients with chronic obstructive pulmonary disease (COPD). Methods Three male participants (age range 31–43) with healthy lungs and 15 patients (M/F = 12:3, age range = 48–73) with COPD (stages II–IV) underwent spirometry tests, quantitative chest computed tomography (QCT), and DXeV-MRI at 1.5-Tesla. Regional delayed ventilation was captured by measuring the temporal signal change in each lung region of interest (ROI) in comparison to that in the trachea. In addition to its qualitative assessment through visual inspection by a clinical radiologist, delayed ventilation was quantitatively captured by calculating a covariance measurement of the lung ROI and trachea signals, and quantified using both the time delay, and the difference between the integrated areas covered by the signal-time curves of the two signals. Results Regional temporal ventilation, consistent with the expected physiological changes across a free breathing cycle, was demonstrated with DXeV-MRI in all patients. Delayed ventilation was observed in 13 of the 15 COPD patients and involved variable lung ROIs. This was in contrast to the control group, where no delayed ventilation was demonstrated (p = 0.0173). Conclusions DXeV-MRI offers a non-invasive way of detecting and quantifying delayed ventilation in patients with COPD, and provides physiological information on regional pulmonary function during a full breathing cycle. Key Points • Dynamic xenon MRI allows for the non-invasive detection and measurement of delayed ventilation in COPD patients. • Dynamic xenon MRI during a free breathing cycle can provide unique information about pulmonary physiology and pulmonary disease pathophysiology. • With further validation, dynamic xenon MRI could offer a non-invasive way of measuring collateral ventilation which can then be used to guide lung volume reduction therapy (LVRT) for certain COPD patients.
- Open Access
- 14 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4058-4067
Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT
To derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs).
- 14 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4058-4067
Open AccessTime-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT
To derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs).
- Open Access
- 5 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (5) , 2283-2292
Magnetic resonance imaging of the time course of hyperpolarized 129Xe gas exchange in the human lungs and heart
Purpose To perform magnetic resonance imaging (MRI), human lung imaging, and quantification of the gas-transfer dynamics of hyperpolarized xenon-129 (HPX) from the alveoli into the blood plasma. Materials and methods HPX MRI with iterative decomposition of water and fat with echo asymmetry and least-square estimation (IDEAL) approach were used with multi-interleaved spiral k-space sampling to obtain HPX gas and dissolved phase images. IDEAL time-series images were then obtained from ten subjects including six normal subjects and four patients with pulmonary emphysema to test the feasibility of the proposed technique for capturing xenon-129 gas-transfer dynamics (XGTD). The dynamics of xenon gas diffusion over the entire lung was also investigated by measuring the signal intensity variations between three regions of interest, including the left and right lungs and the heart using Welch’s t test. Results The technique enabled the acquisition of HPX gas and dissolved phase compartment images in a single breath-hold interval of 8 s. The y-intersect of the XGTD curves were also found to be statistically lower in the patients with lung emphysema than in the healthy group (p < 0.05). Conclusion This time-series IDEAL technique enables the visualization and quantification of inhaled xenon from the alveoli to the left ventricle with a clinical gradient strength magnet during a single breath-hold, in healthy and diseased lungs. Key Points • The proposed hyperpolarized xenon-129 gas and dissolved magnetic resonance imaging technique can provide regional and temporal measurements of xenon-129 gas-transfer dynamics. • Quantitative measurement of xenon-129 gas-transfer dynamics from the alveolar to the heart was demonstrated in normal subjects and pulmonary emphysema. • Comparison of gas-transfer dynamics in normal subjects and pulmonary emphysema showed that the proposed technique appears sensitive to changes affecting the alveoli, pulmonary interstitium, and capillaries.
- 5 December 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (5) , 2283-2292
Open AccessMagnetic resonance imaging of the time course of hyperpolarized 129Xe gas exchange in the human lungs and heart
Purpose To perform magnetic resonance imaging (MRI), human lung imaging, and quantification of the gas-transfer dynamics of hyperpolarized xenon-129 (HPX) from the alveoli into the blood plasma. Materials and methods HPX MRI with iterative decomposition of water and fat with echo asymmetry and least-square estimation (IDEAL) approach were used with multi-interleaved spiral k-space sampling to obtain HPX gas and dissolved phase images. IDEAL time-series images were then obtained from ten subjects including six normal subjects and four patients with pulmonary emphysema to test the feasibility of the proposed technique for capturing xenon-129 gas-transfer dynamics (XGTD). The dynamics of xenon gas diffusion over the entire lung was also investigated by measuring the signal intensity variations between three regions of interest, including the left and right lungs and the heart using Welch’s t test. Results The technique enabled the acquisition of HPX gas and dissolved phase compartment images in a single breath-hold interval of 8 s. The y-intersect of the XGTD curves were also found to be statistically lower in the patients with lung emphysema than in the healthy group (p < 0.05). Conclusion This time-series IDEAL technique enables the visualization and quantification of inhaled xenon from the alveoli to the left ventricle with a clinical gradient strength magnet during a single breath-hold, in healthy and diseased lungs. Key Points • The proposed hyperpolarized xenon-129 gas and dissolved magnetic resonance imaging technique can provide regional and temporal measurements of xenon-129 gas-transfer dynamics. • Quantitative measurement of xenon-129 gas-transfer dynamics from the alveolar to the heart was demonstrated in normal subjects and pulmonary emphysema. • Comparison of gas-transfer dynamics in normal subjects and pulmonary emphysema showed that the proposed technique appears sensitive to changes affecting the alveoli, pulmonary interstitium, and capillaries.
- 26 February 2018
- Published by SAGE Publications in Laboratory Animals
- Vol. 52 (6) , 599-610
Refinement and reduction through application of a quantitative score system for estimation of TB-induced disease burden using computed tomography
Until validated correlates of protection are identified, animal models remain the only way to test the efficacy of the new vaccines and drugs urgently needed to fight the global epidemic caused by infection with Mycobacterium tuberculosis. Non-human primates (NHP) offer the most relevant models of human tuberculosis (TB) and are central to the development process for new interventions. Efficacy evaluations are dependent on the capability of the test model to discriminate improved outcomes between treated groups after experimental exposure to M. tuberculosis and therefore the ability to measure TB-induced disease burden is central to the process. We have developed a score system that allows us to quantify the disease burden induced in macaques by infection with M. tuberculosis, based on the extent and features of disease visible on computed tomography (CT) images. The CT determined disease burden was then verified against that obtained using an established pathology-based approach. Trials of the system as a tool to measure disease burden have shown the approach capable of revealing differences between treatment groups in order to: (a) characterise outcome of infection and enable model refinement; (b) demonstrate the efficacy of drug treatment regimens by showing differences in outcome between test groups. Initial trials suggest that the imaging-based score system provides a valuable additional tool for the measurement of TB-induced disease burden that offers the opportunity to apply both refinement and reduction within studies.
- 26 February 2018
- Published by SAGE Publications in Laboratory Animals
- Vol. 52 (6) , 599-610
Refinement and reduction through application of a quantitative score system for estimation of TB-induced disease burden using computed tomography
Until validated correlates of protection are identified, animal models remain the only way to test the efficacy of the new vaccines and drugs urgently needed to fight the global epidemic caused by infection with Mycobacterium tuberculosis. Non-human primates (NHP) offer the most relevant models of human tuberculosis (TB) and are central to the development process for new interventions. Efficacy evaluations are dependent on the capability of the test model to discriminate improved outcomes between treated groups after experimental exposure to M. tuberculosis and therefore the ability to measure TB-induced disease burden is central to the process. We have developed a score system that allows us to quantify the disease burden induced in macaques by infection with M. tuberculosis, based on the extent and features of disease visible on computed tomography (CT) images. The CT determined disease burden was then verified against that obtained using an established pathology-based approach. Trials of the system as a tool to measure disease burden have shown the approach capable of revealing differences between treatment groups in order to: (a) characterise outcome of infection and enable model refinement; (b) demonstrate the efficacy of drug treatment regimens by showing differences in outcome between test groups. Initial trials suggest that the imaging-based score system provides a valuable additional tool for the measurement of TB-induced disease burden that offers the opportunity to apply both refinement and reduction within studies.
- Open Access
- 2 December 2017
- Published by Springer Nature in Sleep and Breathing
- Vol. 22 (3) , 673-681
Relationships between MRI fat distributions and sleep apnea and obesity hypoventilation syndrome in very obese patients
Purpose Obesity is associated with both obstructive sleep apnea (OSA) and obesity hypoventilation. Differences in adipose tissue distribution are thought to underlie the development of both OSA and hypoventilation. We explored the relationships between the distribution of upper airway, neck, chest, abdominal and muscle fat in very obese individuals. Methods We conducted a cross-sectional cohort study of individuals presenting to a tertiary sleep clinic or for assessment for bariatric surgery. Individuals underwent magnetic resonance (MR) imaging of their upper airway, neck, chest, abdomen and thighs; respiratory polygraphy; 1 week of autotitrating CPAP; and morning arterial blood gas to determine carbon dioxide partial pressure and base excess. Results Fifty-three individuals were included, with mean age of 51.6 ± 8.4 years and mean BMI of 44.3 ± 7.9 kg/m2; there were 27 males (51%). Soft palate, tongue and lateral wall volumes were significantly associated with the AHI in univariable analyses (p < 0.001). Gender was a significant confounder in these associations. No significant associations were found between MRI measures of adiposity and hypoventilation. Conclusions In very obese individuals, our results indicate that increased volumes of upper airway structures are associated with increased severity of OSA, as previously reported in less obese individuals. Increasingly large upper airway structures that reduce pharyngeal lumen size are likely to lead to OSA by increasing the collapsibility of the upper airway. However, we did not show any significant association between regional fat distribution and propensity for hypoventilation, in this population.
- 2 December 2017
- Published by Springer Nature in Sleep and Breathing
- Vol. 22 (3) , 673-681
Open AccessRelationships between MRI fat distributions and sleep apnea and obesity hypoventilation syndrome in very obese patients
Purpose Obesity is associated with both obstructive sleep apnea (OSA) and obesity hypoventilation. Differences in adipose tissue distribution are thought to underlie the development of both OSA and hypoventilation. We explored the relationships between the distribution of upper airway, neck, chest, abdominal and muscle fat in very obese individuals. Methods We conducted a cross-sectional cohort study of individuals presenting to a tertiary sleep clinic or for assessment for bariatric surgery. Individuals underwent magnetic resonance (MR) imaging of their upper airway, neck, chest, abdomen and thighs; respiratory polygraphy; 1 week of autotitrating CPAP; and morning arterial blood gas to determine carbon dioxide partial pressure and base excess. Results Fifty-three individuals were included, with mean age of 51.6 ± 8.4 years and mean BMI of 44.3 ± 7.9 kg/m2; there were 27 males (51%). Soft palate, tongue and lateral wall volumes were significantly associated with the AHI in univariable analyses (p < 0.001). Gender was a significant confounder in these associations. No significant associations were found between MRI measures of adiposity and hypoventilation. Conclusions In very obese individuals, our results indicate that increased volumes of upper airway structures are associated with increased severity of OSA, as previously reported in less obese individuals. Increasingly large upper airway structures that reduce pharyngeal lumen size are likely to lead to OSA by increasing the collapsibility of the upper airway. However, we did not show any significant association between regional fat distribution and propensity for hypoventilation, in this population.
- Open Access
- 16 September 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (5) , 2597-2606
Fast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
Purpose: To develop and optimize a rapid dynamic hyperpolarized 129Xe ventilation (DXeV) MRI protocol and investigate the feasibility of capturing pulmonary signal‐time curves in human lungs.Theory and Methods: Spiral k‐space trajectories were designed with the number of interleaves Nint = 1, 2, 4, and 8 corresponding to voxel sizes of 8 mm, 5 mm, 4 mm, and 2.5 mm, respectively, for field of view = 15 cm. DXeV images were acquired from a gas‐flow phantom to investigate the ability of Nint = 1, 2, 4, and 8 to capture signal‐time curves. A finite element model was constructed to investigate gas‐flow dynamics corroborating the experimental signal‐time curves. DXeV images were also carried out in six subjects (three healthy and three chronic obstructive pulmonary disease subjects).Results: DXeV images and numerical modelling of signal‐time curves permitted the quantification of temporal and spatial resolutions for different numbers of spiral interleaves. The two‐interleaved spiral (Nint = 2) was found to be the most time‐efficient to obtain DXeV images and signal‐time curves of whole lungs with a temporal resolution of 624 ms for 13 slices. Signal‐time curves were well matched in three healthy volunteers. The Spearman's correlations of chronic obstructive pulmonary disease subjects were statistically different from three healthy subjects (P < 0.05).Conclusion: The Nint = 2 spiral demonstrates the successful acquisition of DXeV images and signal‐time curves in healthy subjects and chronic obstructive pulmonary disease patients. Magn Reson Med 79:2597–2606, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
- 16 September 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (5) , 2597-2606
Open AccessFast dynamic ventilation MRI of hyperpolarized 129Xe using spiral imaging
Purpose: To develop and optimize a rapid dynamic hyperpolarized 129Xe ventilation (DXeV) MRI protocol and investigate the feasibility of capturing pulmonary signal‐time curves in human lungs.Theory and Methods: Spiral k‐space trajectories were designed with the number of interleaves Nint = 1, 2, 4, and 8 corresponding to voxel sizes of 8 mm, 5 mm, 4 mm, and 2.5 mm, respectively, for field of view = 15 cm. DXeV images were acquired from a gas‐flow phantom to investigate the ability of Nint = 1, 2, 4, and 8 to capture signal‐time curves. A finite element model was constructed to investigate gas‐flow dynamics corroborating the experimental signal‐time curves. DXeV images were also carried out in six subjects (three healthy and three chronic obstructive pulmonary disease subjects).Results: DXeV images and numerical modelling of signal‐time curves permitted the quantification of temporal and spatial resolutions for different numbers of spiral interleaves. The two‐interleaved spiral (Nint = 2) was found to be the most time‐efficient to obtain DXeV images and signal‐time curves of whole lungs with a temporal resolution of 624 ms for 13 slices. Signal‐time curves were well matched in three healthy volunteers. The Spearman's correlations of chronic obstructive pulmonary disease subjects were statistically different from three healthy subjects (P < 0.05).Conclusion: The Nint = 2 spiral demonstrates the successful acquisition of DXeV images and signal‐time curves in healthy subjects and chronic obstructive pulmonary disease patients. Magn Reson Med 79:2597–2606, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.