OKOzden Kilinc

Ozden Kilinc

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ozden Kilinc has a total of 69 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • 4D Flow MRI derived aortic pulse wave velocity and wall shear stress in Covid-19

    by Ozden Kilinc, Jay Bharat Bisen, Anthony Maroun, Ethan Johnson, Sandra Quinn, Daniel Kim, Daniel C. Lee, Michael Markl, Bradley D. Allen


  • Open Access

    Aortic Hemodynamics with Accelerated Dual-Venc 4D Flow MRI in Type B Aortic Dissection

    by Ozden Kilinc, Justin Baraboo, Joshua Engel, Daniel Giese, Ning Jin, Elizabeth K. Weiss, Anthony Maroun, Kelvin Chow, Xiaoming Bi, Rachel Davids, et al.

    The aim of this study is to investigate the applicability of the dual-venc (DV) 4D flow magnetic resonance imaging (MRI) to quantify the complex flow patterns in type B aortic dissection (TBAD). One GRAPPA-accelerated single-venc (SV) and one compressed-sensing (CS) accelerated DV 4D flow MRI sequences are used to scan all subjects, including twelve chronic TBAD patients and two volunteers. The scans are performed twice for the reproducibility assessment of the scan protocols. Voxelwise quantitative flow parameters including kinetic energy (KE), peak velocity (PV), forward and reverse flows (FF, RF) and stasis are calculated. High-venc (HV) data from the DV acquisition are separately analyzed. The scan time reduction by the CS-accelerated DV 4D flow MRI acquisition is 46.4% compared with the SV acquisition. The DV velocity-to-noise ratio (VNR) is higher compared with HV (p = 0.000). No true lumen (TL) parameter shows a significant difference among the acquisition types (p > 0.05). The false lumen (FL) RF is higher in SV compared with the DV acquisition (p = 0.009). The KE is higher (p = 0.038) and stasis is lower (p = 0.01) in HV compared with SV acquisition. All FL parameters except stasis are higher and stasis is lower in HV compared with DV acquisition (p < 0.05). Positive Pearson correlations among the acquisition types in TL and high agreements between the two scans for all acquisition types are observed except HV RF in the FL, which demonstrates a moderate agreement. The CS-accelerated DV 4D flow MRI may have utility in the clinical daily routine with shortened scan times and improved velocity measurements while providing high VNR in TBAD. The observed hemodynamic flow trends are similar between GRAPPA-accelerated SV and CS-accelerated DV 4D flow MRI acquisitions; however, parameters are more impacted by CS-accelerated HV protocol in FL, which may be secondary to the CS regularization effects.


  • Open Access

    Entry tear hemodynamics using 4D flow MRI in a patient with acute type B aortic dissection

    by Sophia Z. Liu, Joshua S. Engel, Jay B. Bisen, Ozden Kilinc, Sandra Quinn, Andrew W. Hoel, Christopher K. Mehta, Michael Markl, Bradley D. Allen


  • Open Access

    Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI

    by Ozden Kilinc, Stanley Chu, Justin Baraboo, Elizabeth K. Weiss, Joshua Engel, Anthony Maroun, Daniel Giese, Ning Jin, Kelvin Chow, Xiaoming Bi, et al.

    Background: 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD).Purpose: To investigate CS‐accelerated 4D Flow MRI performance compared to GRAPP‐accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD.Study Type: Prospective.Population: Twelve TBAD patients, two volunteers.Field Strength/Sequence: 1.5T, 3D time‐resolved cine phase‐contrast gradient echo sequence.Assessment: GRAPPA (acceleration factor [R] = 2) and two CS‐accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane‐based mid‐lumen flows were quantified. Imaging times were recorded.Tests: Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance.Results: The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781–0.986]), and low to strong in FL (r = [0.347–0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732–0.989). The FF and net flow in mid‐descending aorta TL were significantly different between CS7.7 and CS10.2.Conclusion: CS‐accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS‐acceleration impacts KE, FF, RF, and stasis more in FL.Evidence Level: 1Technical Efficacy: Stage 2


  • Radiomic analysis of magnetic resonance fingerprinting in adult brain tumors

    by Sara Dastmalchian, Ozden Kilinc, Louisa Onyewadume, Charit Tippareddy, Debra McGivney, Dan Ma, Mark Griswold, Jeffrey Sunshine, Vikas Gulani, Jill S. Barnholtz-Sloan, et al.

    Purpose This is a radiomics study investigating the ability of texture analysis of MRF maps to improve differentiation between intra-axial adult brain tumors and to predict survival in the glioblastoma cohort. Methods Magnetic resonance fingerprinting (MRF) acquisition was performed on 31 patients across 3 groups: 17 glioblastomas, 6 low-grade gliomas, and 8 metastases. Using regions of interest for the solid tumor and peritumoral white matter on T1 and T2 maps, second-order texture features were calculated from gray-level co-occurrence matrices and gray-level run length matrices. Selected features were compared across the three tumor groups using Wilcoxon rank-sum test. Receiver operating characteristic curve analysis was performed for each feature. Kaplan-Meier method was used for survival analysis with log rank tests. Results Low-grade gliomas and glioblastomas had significantly higher run percentage, run entropy, and information measure of correlation 1 on T1 than metastases (p < 0.017). The best separation of all three tumor types was seen utilizing inverse difference normalized and homogeneity values for peritumoral white matter in both T1 and T2 maps (p < 0.017). In solid tumor T2 maps, lower values in entropy and higher values of maximum probability and high-gray run emphasis were associated with longer survival in glioblastoma patients (p < 0.05). Several texture features were associated with longer survival in glioblastoma patients on peritumoral white matter T1 maps (p < 0.05). Conclusion Texture analysis of MRF-derived maps can improve our ability to differentiate common adult brain tumors by characterizing tumor heterogeneity, and may have a role in predicting outcomes in patients with glioblastoma.


  • Cutaneous silent period in myofascial pain syndrome

    by Ozden Kilinc, Savas Sencan, Tulay Ercalik, Pinar Kahraman Koytak, Hande Alibas, Osman Hakan Gunduz, Tulin Tanridag, Kayihan Uluc

    Introduction: An increased response to painful stimuli without spontaneous pain suggests a role of central hyperexcitability of pain pathways in the pathogenesis of myofascial pain syndrome (MPS). In this study we aimed to test the hypothesis that spinal pain pathways are affected in MPS. We used cutaneous silent period (CSP) parameters to demonstrate the hyperexcitability of spinal pain pathways in MPS. Methods: Twenty‐nine patients diagnosed with MPS and 30 healthy volunteers were included in the study. The CSP recordings were performed in the right upper and left lower extremities. Results: In both upper and lower extremities, patients had prolonged CSP latencies (P = 0.034 and P = 0.049 respectively) and shortened CSP durations (P = 0.009 and P = 0.008, respectively). Discussion: Delayed and shortened CSP in MPS patients implies dysfunction in the inhibitory mechanism of the spinal/supraspinal pain pathways, suggesting central sensitization in the pathogenesis of MPS and supporting our research hypothesis. Muscle Nerve 57: E24–E28, 2018


  • Open Access

    Assessment of Time and Frequency Domain Parameters of Heart Rate Variability and Interictal Cardiac Rhythm Abnormalities in Drug-naïve Patients with Idiopathic Generalized Epilepsy

    by Ozden Kilinc, Altug Cincin, Aslihan Pehlivan, Ipek Midi, Alper Kepez, Kadriye Agan

    Epilepsy is a disease known to occur with autonomous phenomenons. Earlier studies indicate decreased heart rate variability (HRV) during ictal and interictal periods among epilepsy patients. In this study, we aim to investigate cardiac rhythm abnormalities and HRV during interictal period between drug-naïve patients with idiopathic generalized epilepsy (IGE) and healthy control group. Twenty-six patients with IGE and 26 healthy individuals included in the study. In order to eliminate any structural cardiac pathology, transthoracic echocardiography was performed in all subjects and time and frequency domain parameters of HRV were evaluated after 24-hour rhythm holter monitoring. Between two groups, no significant difference was detected in terms of mean heart rate and maximum duration between the start of the Q waves and the end of the T waves (QT intervals). In the time domain analysis of HRV, no statically significant difference was detected for standard deviation of all R - R intervals and root-mean-square of successive differences between patient and control group (p = 0,070 and p = 0,104 respectively). In the frequency domain analysis of HRV, patients tended to display lower total power and very low frequency power than did healthy subjects, but the differences were not statistically significant. Our results suggest that there is no major effect of the epilepsy on HRV in patients with IGE. It should be emphasized that, in this study, HRV was evaluated only in patients with IGE and that the results are not proper to be generalized for patients with partial seizures.