Volker Herold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Volker Herold has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Peter Michael Jakob
Experimental Physics 5 University of Würzburg Würzburg Germany
9 shared publications Eberhard Rommel
Julius-Maximilians-Universität Würzburg, Lehrstuhl für Experimentelle Physik 5, Würzburg, Germany
3 shared publications- Wolfgang Rudolf Bauer
Department of Cardiovascular Imaging, Chair of Molecular and Cellular Imaging, Comprehensive Heart Failure Center University Hospital Würzburg Würzburg Germany
3 shared publications - Alma Zernecke
Institute of Experimental Biomedicine, University Hospital Würzburg , Josef-Schneider-Str. 2, D16, Würzburg 97080
2 shared publications - Axel Haase
Technische Universität München, Munich, Germany
2 shared publications - Christian Herbert Ziener
Department of Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
2 shared publications
Latest Publications
- Open Access
- 15 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (3) , 1232-1247
Enhancing quality and speed in database‐free neural network reconstructions of undersampled MRI with SCAMPI
Purpose: We present SCAMPI (Sparsity Constrained Application of deep Magnetic resonance Priors for Image reconstruction), an untrained deep Neural Network for MRI reconstruction without previous training on datasets. It expands the Deep Image Prior approach with a multidomain, sparsity‐enforcing loss function to achieve higher image quality at a faster convergence speed than previously reported methods.Methods: Two‐dimensional MRI data from the FastMRI dataset with Cartesian undersampling in phase‐encoding direction were reconstructed for different acceleration rates for single coil and multicoil data.Results: The performance of our architecture was compared to state‐of‐the‐art Compressed Sensing methods and ConvDecoder, another untrained Neural Network for two‐dimensional MRI reconstruction. SCAMPI outperforms these by better reducing undersampling artifacts and yielding lower error metrics in multicoil imaging. In comparison to ConvDecoder, the U‐Net architecture combined with an elaborated loss‐function allows for much faster convergence at higher image quality. SCAMPI can reconstruct multicoil data without explicit knowledge of coil sensitivity profiles. Moreover, it is a novel tool for reconstructing undersampled single coil k‐space data.Conclusion: Our approach avoids overfitting to dataset features, that can occur in Neural Networks trained on databases, because the network parameters are tuned only on the reconstruction data. It allows better results and faster reconstruction than the baseline untrained Neural Network approach.
- 15 May 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (3) , 1232-1247
Open AccessEnhancing quality and speed in database‐free neural network reconstructions of undersampled MRI with SCAMPI
Purpose: We present SCAMPI (Sparsity Constrained Application of deep Magnetic resonance Priors for Image reconstruction), an untrained deep Neural Network for MRI reconstruction without previous training on datasets. It expands the Deep Image Prior approach with a multidomain, sparsity‐enforcing loss function to achieve higher image quality at a faster convergence speed than previously reported methods.Methods: Two‐dimensional MRI data from the FastMRI dataset with Cartesian undersampling in phase‐encoding direction were reconstructed for different acceleration rates for single coil and multicoil data.Results: The performance of our architecture was compared to state‐of‐the‐art Compressed Sensing methods and ConvDecoder, another untrained Neural Network for two‐dimensional MRI reconstruction. SCAMPI outperforms these by better reducing undersampling artifacts and yielding lower error metrics in multicoil imaging. In comparison to ConvDecoder, the U‐Net architecture combined with an elaborated loss‐function allows for much faster convergence at higher image quality. SCAMPI can reconstruct multicoil data without explicit knowledge of coil sensitivity profiles. Moreover, it is a novel tool for reconstructing undersampled single coil k‐space data.Conclusion: Our approach avoids overfitting to dataset features, that can occur in Neural Networks trained on databases, because the network parameters are tuned only on the reconstruction data. It allows better results and faster reconstruction than the baseline untrained Neural Network approach.
- Open Access
- 3 March 2023
- Published by Springer Nature in Research Square
SCAMPI – database-free neural network reconstruction for undersampled Magnetic Resonance Imaging
Reducing acquisition time in Magnetic Resonance Imaging (MRI) is mainly based on vast undersampling of the data measured in spatial frequency domain. The resulting artifacts are reduced by various reconstruction algorithms. Here, we present SCAMPI Sparsity Constrained Application of deep Magnetic resonance Priors for Image reconstruction), a deep Neural Network, that utilizes the Deep Image Prior approach together with sparsity constraints to reconstruct undersampled MRI data without any previous training on external datasets. Two-dimensional MRI data from the public FastMRI dataset with Cartesian undersampling in phase-encoding direction were reconstructed for different acceleration rates for single coil and multicoil data. Performance of the proposed architecture was compared to Parallel Imaging with Compressed Sensing. SCAMPI outperforms these state-of-the-art algorithms by better reducing undersampling artifacts and yielding lower error metrics in multicoil imaging. It is a novel tool for reconstructing undersampled single coil k-space data. Furthermore, SCAMPI works on multicoil data without explicit knowledge of coil sensitivity profiles. The presented approach avoids overfitting to dataset features, that can occur in Neural Networks trained on databases.
- 3 March 2023
- Published by Springer Nature in Research Square
Open AccessSCAMPI – database-free neural network reconstruction for undersampled Magnetic Resonance Imaging
Reducing acquisition time in Magnetic Resonance Imaging (MRI) is mainly based on vast undersampling of the data measured in spatial frequency domain. The resulting artifacts are reduced by various reconstruction algorithms. Here, we present SCAMPI Sparsity Constrained Application of deep Magnetic resonance Priors for Image reconstruction), a deep Neural Network, that utilizes the Deep Image Prior approach together with sparsity constraints to reconstruct undersampled MRI data without any previous training on external datasets. Two-dimensional MRI data from the public FastMRI dataset with Cartesian undersampling in phase-encoding direction were reconstructed for different acceleration rates for single coil and multicoil data. Performance of the proposed architecture was compared to Parallel Imaging with Compressed Sensing. SCAMPI outperforms these state-of-the-art algorithms by better reducing undersampling artifacts and yielding lower error metrics in multicoil imaging. It is a novel tool for reconstructing undersampled single coil k-space data. Furthermore, SCAMPI works on multicoil data without explicit knowledge of coil sensitivity profiles. The presented approach avoids overfitting to dataset features, that can occur in Neural Networks trained on databases.
- Open Access
- 7 December 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1856
2D Projection Maps of WSS and OSI Reveal Distinct Spatiotemporal Changes in Hemodynamics in the Murine Aorta during Ageing and Atherosclerosis
Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe−/−, n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.
- 7 December 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (12) , 1856
Open Access2D Projection Maps of WSS and OSI Reveal Distinct Spatiotemporal Changes in Hemodynamics in the Murine Aorta during Ageing and Atherosclerosis
Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe−/−, n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe−/− mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability.
- Open Access
- 12 February 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (2) , 185
Evaluation of Plaque Characteristics and Inflammation Using Magnetic Resonance Imaging
Atherosclerosis is an inflammatory disease of large and medium-sized arteries, characterized by the growth of atherosclerotic lesions (plaques). These plaques often develop at inner curvatures of arteries, branchpoints, and bifurcations, where the endothelial wall shear stress is low and oscillatory. In conjunction with other processes such as lipid deposition, biomechanical factors lead to local vascular inflammation and plaque growth. There is also evidence that low and oscillatory shear stress contribute to arterial remodeling, entailing a loss in arterial elasticity and, therefore, an increased pulse-wave velocity. Although altered shear stress profiles, elasticity and inflammation are closely intertwined and critical for plaque growth, preclinical and clinical investigations for atherosclerosis mostly focus on the investigation of one of these parameters only due to the experimental limitations. However, cardiovascular magnetic resonance imaging (MRI) has been demonstrated to be a potent tool which can be used to provide insights into a large range of biological parameters in one experimental session. It enables the evaluation of the dynamic process of atherosclerotic lesion formation without the need for harmful radiation. Flow-sensitive MRI provides the assessment of hemodynamic parameters such as wall shear stress and pulse wave velocity which may replace invasive and radiation-based techniques for imaging of the vascular function and the characterization of early plaque development. In combination with inflammation imaging, the analyses and correlations of these parameters could not only significantly advance basic preclinical investigations of atherosclerotic lesion formation and progression, but also the diagnostic clinical evaluation for early identification of high-risk plaques, which are prone to rupture. In this review, we summarize the key applications of magnetic resonance imaging for the evaluation of plaque characteristics through flow sensitive and morphological measurements. The simultaneous measurements of functional and structural parameters will further preclinical research on atherosclerosis and has the potential to fundamentally improve the detection of inflammation and vulnerable plaques in patients.
- 12 February 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (2) , 185
Open AccessEvaluation of Plaque Characteristics and Inflammation Using Magnetic Resonance Imaging
Atherosclerosis is an inflammatory disease of large and medium-sized arteries, characterized by the growth of atherosclerotic lesions (plaques). These plaques often develop at inner curvatures of arteries, branchpoints, and bifurcations, where the endothelial wall shear stress is low and oscillatory. In conjunction with other processes such as lipid deposition, biomechanical factors lead to local vascular inflammation and plaque growth. There is also evidence that low and oscillatory shear stress contribute to arterial remodeling, entailing a loss in arterial elasticity and, therefore, an increased pulse-wave velocity. Although altered shear stress profiles, elasticity and inflammation are closely intertwined and critical for plaque growth, preclinical and clinical investigations for atherosclerosis mostly focus on the investigation of one of these parameters only due to the experimental limitations. However, cardiovascular magnetic resonance imaging (MRI) has been demonstrated to be a potent tool which can be used to provide insights into a large range of biological parameters in one experimental session. It enables the evaluation of the dynamic process of atherosclerotic lesion formation without the need for harmful radiation. Flow-sensitive MRI provides the assessment of hemodynamic parameters such as wall shear stress and pulse wave velocity which may replace invasive and radiation-based techniques for imaging of the vascular function and the characterization of early plaque development. In combination with inflammation imaging, the analyses and correlations of these parameters could not only significantly advance basic preclinical investigations of atherosclerotic lesion formation and progression, but also the diagnostic clinical evaluation for early identification of high-risk plaques, which are prone to rupture. In this review, we summarize the key applications of magnetic resonance imaging for the evaluation of plaque characteristics through flow sensitive and morphological measurements. The simultaneous measurements of functional and structural parameters will further preclinical research on atherosclerosis and has the potential to fundamentally improve the detection of inflammation and vulnerable plaques in patients.
- Open Access
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 77
Assessment of local pulse wave velocity distribution in mice using k-t BLAST PC-CMR with semi-automatic area segmentation
- 1 December 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 19 (1) , 77
Open AccessAssessment of local pulse wave velocity distribution in mice using k-t BLAST PC-CMR with semi-automatic area segmentation
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 88
Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 88
Open AccessFast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory
- Open Access
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 72
Regional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 72
Open AccessRegional in vivo transit time measurements of aortic pulse wave velocity in mice with high-field CMR at 17.6 Tesla
- Open Access
- 7 April 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (6) , 1293-1299
In vivo measurement of local aortic pulse‐wave velocity in mice with MR microscopy at 17.6 tesla
Transgenic mouse models of human diseases have gained increasing importance in the pathophysiology of cardiovascular diseases (CVD). As an indirect measure of vascular stiffness, aortic pulse‐wave velocity (PWV) is an important predictor of cardiovascular risk. This study presents an MRI approach that uses a flow area method to estimate local aortic pulse‐wave velocity at different sites in the murine aorta. By simultaneously measuring the cross‐sectional area and the through‐plane velocity with a phase‐contrast CINE method, it was possible to measure average values for the PWV in the ascending and descending aorta within the range of 2.4–4.3 m/s for C57BL/6J mice (ages 2 and 8 months) and apoE‐knockout mice (age 8 months). Statistically significant differences of the mean values of the PWV of both groups could be determined. By repeating CINE measurements with a time delay of 1 ms between two subsequent data sets, an effective temporal resolution of 1000 frames/s (fps) could be achieved. Magn Reson Med, 2009.
- 7 April 2009
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (6) , 1293-1299
Open AccessIn vivo measurement of local aortic pulse‐wave velocity in mice with MR microscopy at 17.6 tesla
Transgenic mouse models of human diseases have gained increasing importance in the pathophysiology of cardiovascular diseases (CVD). As an indirect measure of vascular stiffness, aortic pulse‐wave velocity (PWV) is an important predictor of cardiovascular risk. This study presents an MRI approach that uses a flow area method to estimate local aortic pulse‐wave velocity at different sites in the murine aorta. By simultaneously measuring the cross‐sectional area and the through‐plane velocity with a phase‐contrast CINE method, it was possible to measure average values for the PWV in the ascending and descending aorta within the range of 2.4–4.3 m/s for C57BL/6J mice (ages 2 and 8 months) and apoE‐knockout mice (age 8 months). Statistically significant differences of the mean values of the PWV of both groups could be determined. By repeating CINE measurements with a time delay of 1 ms between two subsequent data sets, an effective temporal resolution of 1000 frames/s (fps) could be achieved. Magn Reson Med, 2009.
- 20 January 2009
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 22 (3) , 159-166
In vivo comparison of atherosclerotic plaque progression with vessel wall strain and blood flow velocity in apoE−/− mice with MR microscopy at 17.6 T
At present, in vivo plaque characterization in mice by MRI is typically limited to the visualization of vascular lesions with no accompanying analysis of vessel wall function. The aim of this study was to analyze the influence of atherosclerotic plaque development on the morphological and mechanical characteristics of the aortic vessel wall in a pre-clinical murine model of atherosclerosis.
- 20 January 2009
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 22 (3) , 159-166
In vivo comparison of atherosclerotic plaque progression with vessel wall strain and blood flow velocity in apoE−/− mice with MR microscopy at 17.6 T
At present, in vivo plaque characterization in mice by MRI is typically limited to the visualization of vascular lesions with no accompanying analysis of vessel wall function. The aim of this study was to analyze the influence of atherosclerotic plaque development on the morphological and mechanical characteristics of the aortic vessel wall in a pre-clinical murine model of atherosclerosis.
- Open Access
- 4 April 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (5) , 1058-1064
In vivo quantitative three‐dimensional motion mapping of the murine myocardium with PC‐MRI at 17.6 T
This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired at three different levels in the murine myocardium with an in-plane resolution of 98 μm, a slice thickness of 0.6 mm, and a temporal resolution of 6 ms. The applied PC-MRI method was validated with phantom experiments that confirmed the correctness of the method with deviations of <1.7%. Myocardial in-plane velocities between 0.5 cm/s and 2.2 cm/s were determined for the healthy murine myocardium. Through-plane velocities of 0.1–0.83 cm/s were measured. Velocity data was also used to calculate the myocardial twist angle during systole at different slices in the short-axis view. Magn Reson Med, 2006.
- 4 April 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (5) , 1058-1064
Open AccessIn vivo quantitative three‐dimensional motion mapping of the murine myocardium with PC‐MRI at 17.6 T
This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired at three different levels in the murine myocardium with an in-plane resolution of 98 μm, a slice thickness of 0.6 mm, and a temporal resolution of 6 ms. The applied PC-MRI method was validated with phantom experiments that confirmed the correctness of the method with deviations of <1.7%. Myocardial in-plane velocities between 0.5 cm/s and 2.2 cm/s were determined for the healthy murine myocardium. Through-plane velocities of 0.1–0.83 cm/s were measured. Velocity data was also used to calculate the myocardial twist angle during systole at different slices in the short-axis view. Magn Reson Med, 2006.