Petr Schauer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petr Schauer has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Miroslav Kucera
Faculty of Mathematics and Physics, Charles University, Ke Karlovu 5, 12116 Prague 2, Czech Republic
4 shared publications R. Autrata
Department of Electron Optics, Institute of Scientific Instruments, Czechoslovak Academy of Sciences, Brno, Czechoslovakia
4 shared publicationsJan Bok
3 shared publications- Ondřej Lalinský
Institute of Scientific Instruments Czech Academy of Sciences Kralovopolska 147 Brno 612 64 Czech Republic
3 shared publications Rudolf Autrata
Institute of Scientific Instruments, ASCR, Královopolská 147, CZ-61264 Brno, Czech Republic
3 shared publicationsB. Perner
Monokrystaly Leninova 175 51119 Turnov, Czechoslovakia
2 shared publications
Latest Publications
- 4 January 2022
- Published by Wiley in Microscopy Research and Technique
- Vol. 85 (5) , 1870-1883
Comparison of photon transport efficiency in simple scintillation electron detector configurations for scanning electron microscope
The purpose of this paper is to find some general rules for the design of robust scintillation electron detectors for a scanning electron microscope (SEM) that possesses an efficient light-guiding (LG) system. The paper offers some general instructions on how to avoid the improper design of highly inefficient LG configurations of the detectors. Attention was paid to the relevant optical properties of the scintillator, light guide, and other components used in the LG part of the scintillation detector. Utilizing the optical properties of the detector components, 3D Monte Carlo (MC) simulations of photon transport efficiency in the simple scintillation detector configurations were performed using the computer application called SCIUNI to assess shapes and dimensions of the LG part of the detector. The results of the simulation of both base-guided signal (BGS) configurations for SE detection and edge-guided signal (EGS) configurations for BSE detection are presented. It is demonstrated that the BGS configuration with a matted disc scintillator exit side connected to the cylindrical light guide without optical cement is almost always a sufficiently efficient system with a mean LG efficiency of about 20%. It is simulated that poorly designed EGS strip configurations have an extremely low mean LG efficiency of only 0.01%, which can significantly reduce detector performance. On the other hand, no simple nonoptimized EGS configuration with a light guide widening to a circular or square profile, with a polished cemented scintillator and with an indispensable hole in it has a mean LG efficiency lower than 6.5%.
- 4 January 2022
- Published by Wiley in Microscopy Research and Technique
- Vol. 85 (5) , 1870-1883
Comparison of photon transport efficiency in simple scintillation electron detector configurations for scanning electron microscope
The purpose of this paper is to find some general rules for the design of robust scintillation electron detectors for a scanning electron microscope (SEM) that possesses an efficient light-guiding (LG) system. The paper offers some general instructions on how to avoid the improper design of highly inefficient LG configurations of the detectors. Attention was paid to the relevant optical properties of the scintillator, light guide, and other components used in the LG part of the scintillation detector. Utilizing the optical properties of the detector components, 3D Monte Carlo (MC) simulations of photon transport efficiency in the simple scintillation detector configurations were performed using the computer application called SCIUNI to assess shapes and dimensions of the LG part of the detector. The results of the simulation of both base-guided signal (BGS) configurations for SE detection and edge-guided signal (EGS) configurations for BSE detection are presented. It is demonstrated that the BGS configuration with a matted disc scintillator exit side connected to the cylindrical light guide without optical cement is almost always a sufficiently efficient system with a mean LG efficiency of about 20%. It is simulated that poorly designed EGS strip configurations have an extremely low mean LG efficiency of only 0.01%, which can significantly reduce detector performance. On the other hand, no simple nonoptimized EGS configuration with a light guide widening to a circular or square profile, with a polished cemented scintillator and with an indispensable hole in it has a mean LG efficiency lower than 6.5%.
- 2 November 2020
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (4) , 753-770
Overview of S(T)EM electron detectors with garnet scintillators: Some potentials and limits
The paper is focused on a complete configuration and design of a scintillation electron detector in scanning electron and/or scanning transmission electron microscopes (S(T)EM) with garnet scintillators. All processes related to the scintillator and light guide were analyzed. In more detail, excitation electron trajectories and absorbed energy distributions, efficiencies and kinetics of scintillators, as well as the influence of their anti‐charging coatings and their substrates, assigned optical properties, and light guide efficiencies of different configurations were presented and discussed. The results indicate problems with low‐energy detection below 1 keV when the scandium conductive coating with a thickness of only 3 nm must be used to allow electron penetration without significant losses. It was shown that the short rise and decay time and low afterglow of LuGdGaAG:Ce liquid‐phase epitaxy garnet film scintillators guarantee a strong modulation transfer function of the entire imaging system resulting in a contrast transfer ability up to 0.6 lp/pixel. Small film scintillator thicknesses were found to be an advantage due to the low signal self‐absorption. The optical absorption coefficients, refractive indices, and the mirror optical reflectance of materials involved in the light transport to the photomultiplier tube photocathode were investigated. The computer‐optimized design SCIUNI application was used to configure the optimized light guide system. It was shown that nonoptimized edge‐guided systems possess very poor light guiding efficiency as low as 1%, while even very complex optimized ones can achieve more than 20%.
- 2 November 2020
- Published by Wiley in Microscopy Research and Technique
- Vol. 84 (4) , 753-770
Overview of S(T)EM electron detectors with garnet scintillators: Some potentials and limits
The paper is focused on a complete configuration and design of a scintillation electron detector in scanning electron and/or scanning transmission electron microscopes (S(T)EM) with garnet scintillators. All processes related to the scintillator and light guide were analyzed. In more detail, excitation electron trajectories and absorbed energy distributions, efficiencies and kinetics of scintillators, as well as the influence of their anti‐charging coatings and their substrates, assigned optical properties, and light guide efficiencies of different configurations were presented and discussed. The results indicate problems with low‐energy detection below 1 keV when the scandium conductive coating with a thickness of only 3 nm must be used to allow electron penetration without significant losses. It was shown that the short rise and decay time and low afterglow of LuGdGaAG:Ce liquid‐phase epitaxy garnet film scintillators guarantee a strong modulation transfer function of the entire imaging system resulting in a contrast transfer ability up to 0.6 lp/pixel. Small film scintillator thicknesses were found to be an advantage due to the low signal self‐absorption. The optical absorption coefficients, refractive indices, and the mirror optical reflectance of materials involved in the light transport to the photomultiplier tube photocathode were investigated. The computer‐optimized design SCIUNI application was used to configure the optimized light guide system. It was shown that nonoptimized edge‐guided systems possess very poor light guiding efficiency as low as 1%, while even very complex optimized ones can achieve more than 20%.
- 19 June 2019
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (18)
Influence of Mg‐to‐Ce Concentration Ratio on Cathodoluminescence in LuAG and LuGAGG Single‐Crystalline Films
The cathodoluminescence (CL) characterizations of Lu3Al5O12:Ce,Mg (LuAG:Ce,Mg) and of multicomponent (Lu0.25Gd0.74)3(Ga2.48Al2.52)O12:Ce,Mg (LuGAGG:Ce,Mg) single‐crystalline garnet films are supported by the optical absorption spectroscopy. Using this approach, the influence of the Mg‐to‐Ce concentration ratio on the CL spectra and the CL decay is analyzed. The crucial role of stable Ce4+ centers in CL is shown in Mg‐rich film studies. Although the CL intensity is somewhat reduced, drastic improvements in timing performance are demonstrated, including the CL decay time as low as 4.2 ns and the afterglow as low as 0.015% at 500 ns after the e‐beam excitation cutoff. These results predetermine the utilization of the LuAG:Ce,Mg and LuGAGG:Ce,Mg single‐crystalline films in e‐beam detection systems, where especially fast scintillator response is crucial.
- 19 June 2019
- Published by Wiley in Physica Status Solidi (a)
- Vol. 216 (18)
Influence of Mg‐to‐Ce Concentration Ratio on Cathodoluminescence in LuAG and LuGAGG Single‐Crystalline Films
The cathodoluminescence (CL) characterizations of Lu3Al5O12:Ce,Mg (LuAG:Ce,Mg) and of multicomponent (Lu0.25Gd0.74)3(Ga2.48Al2.52)O12:Ce,Mg (LuGAGG:Ce,Mg) single‐crystalline garnet films are supported by the optical absorption spectroscopy. Using this approach, the influence of the Mg‐to‐Ce concentration ratio on the CL spectra and the CL decay is analyzed. The crucial role of stable Ce4+ centers in CL is shown in Mg‐rich film studies. Although the CL intensity is somewhat reduced, drastic improvements in timing performance are demonstrated, including the CL decay time as low as 4.2 ns and the afterglow as low as 0.015% at 500 ns after the e‐beam excitation cutoff. These results predetermine the utilization of the LuAG:Ce,Mg and LuGAGG:Ce,Mg single‐crystalline films in e‐beam detection systems, where especially fast scintillator response is crucial.
- 27 December 2018
- Published by Wiley in Microscopy Research and Technique
- Vol. 82 (3) , 272-282
Prospective scintillation electron detectors for S(T)EM based on garnet film scintillators
The performance of a scintillation electron detector for a scanning electron microscope and/or a scanning transmission electron microscope (S(T)EM) based on new epitaxial garnet film scintillators was explored. The LuGAGG:Ce and LuGAGG:Ce,Mg film scintillators with chemical formula (Ce0.01Lu0.27Gd0.74)3–wMgw(Ga2.48Al2.46)O12 were prepared and their cathodoluminescence (CL) and optical properties were studied and compared with the properties of current standard bulk single crystal YAG:Ce and YAP:Ce scintillators. More specifically, CL decay characteristics, CL emission spectra, CL intensities, optical absorption coefficients, and the refractive indices of the mentioned scintillators were measured. Furthermore, electron interaction volumes with absorbed energy distributions, photomultiplier (PMT) photocathode matchings, modulation transfer functions (MTF), and the photon transport efficiencies of scintillation detectors with the mentioned scintillators were calculated. A CL decay time for the LuGAGG:Ce,Mg film scintillator as low as 28 ns with an afterglow of only 0.02% at 1 μs after the e‐beam excitation was observed. As determined from calculated MTFs, the scintillation detectors with the new film scintillators lose contrast transfer ability above 0.6 lp/pixel, while the currently commonly used YAG:Ce single crystal scintillators already do so above 0.1 lp/pixel. It was also calculated that the new studied film scintillators have an 8% higher photon transfer efficiency, even for a simple disk shape compared with the standard bulk single crystal YAG:Ce scintillator. The studied LuGAGG:Ce,Mg epitaxial garnet film scintillators were evaluated as prospective fast scintillators for electron detectors, not only in S(T)EM but also in other e‐beam devices.
- 27 December 2018
- Published by Wiley in Microscopy Research and Technique
- Vol. 82 (3) , 272-282
Prospective scintillation electron detectors for S(T)EM based on garnet film scintillators
The performance of a scintillation electron detector for a scanning electron microscope and/or a scanning transmission electron microscope (S(T)EM) based on new epitaxial garnet film scintillators was explored. The LuGAGG:Ce and LuGAGG:Ce,Mg film scintillators with chemical formula (Ce0.01Lu0.27Gd0.74)3–wMgw(Ga2.48Al2.46)O12 were prepared and their cathodoluminescence (CL) and optical properties were studied and compared with the properties of current standard bulk single crystal YAG:Ce and YAP:Ce scintillators. More specifically, CL decay characteristics, CL emission spectra, CL intensities, optical absorption coefficients, and the refractive indices of the mentioned scintillators were measured. Furthermore, electron interaction volumes with absorbed energy distributions, photomultiplier (PMT) photocathode matchings, modulation transfer functions (MTF), and the photon transport efficiencies of scintillation detectors with the mentioned scintillators were calculated. A CL decay time for the LuGAGG:Ce,Mg film scintillator as low as 28 ns with an afterglow of only 0.02% at 1 μs after the e‐beam excitation was observed. As determined from calculated MTFs, the scintillation detectors with the new film scintillators lose contrast transfer ability above 0.6 lp/pixel, while the currently commonly used YAG:Ce single crystal scintillators already do so above 0.1 lp/pixel. It was also calculated that the new studied film scintillators have an 8% higher photon transfer efficiency, even for a simple disk shape compared with the standard bulk single crystal YAG:Ce scintillator. The studied LuGAGG:Ce,Mg epitaxial garnet film scintillators were evaluated as prospective fast scintillators for electron detectors, not only in S(T)EM but also in other e‐beam devices.
- 1 October 2017
- Published by Elsevier in Optical Materials
- Vol. 72, 359-366
Effect of Mg co-doping on cathodoluminescence properties of LuGAGG:Ce single crystalline garnet films
- 1 October 2017
- Published by Elsevier in Optical Materials
- Vol. 72, 359-366
Effect of Mg co-doping on cathodoluminescence properties of LuGAGG:Ce single crystalline garnet films
- Open Access
- 20 December 2016
- Published by Wiley
- p. 374-375
Multicomponent garnet film scintillators for SEM electron detectors
- 20 December 2016
- Published by Wiley
- p. 374-375
Open AccessMulticomponent garnet film scintillators for SEM electron detectors
- 1 January 2016
- Published by Elsevier in Journal of Luminescence
- Vol. 169, 674-677
Scintillation response of Ce3+ doped GdGa-LuAG multicomponent garnet films under e-beam excitation
- 1 January 2016
- Published by Elsevier in Journal of Luminescence
- Vol. 169, 674-677
Scintillation response of Ce3+ doped GdGa-LuAG multicomponent garnet films under e-beam excitation
- 14 May 2014
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 25 (7)
Apparatus for temperature-dependent cathodoluminescence characterization of materials
- 14 May 2014
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 25 (7)
Apparatus for temperature-dependent cathodoluminescence characterization of materials
Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function
Summary: In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e‐beam is used in order to create well‐defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart–Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single‐crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e‐beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point‐by‐point and continual‐sweep e‐beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. SCANNING 36:384–393, 2014.
Performance of SEM scintillation detector evaluated by modulation transfer function and detective quantum efficiency function
Summary: In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector's influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for the SEM detector are described. In this technique, the time modulated e‐beam is used in order to create well‐defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart–Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single‐crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type of the e‐beam scan. The results demonstrate the great benefit of the description of SEM detectors using the MTF and DQE. In addition, point‐by‐point and continual‐sweep e‐beam scans in SEM were discussed and their influence on the image quality was revealed using the MTF. SCANNING 36:384–393, 2014.