Arthur R. Ghigo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arthur R. Ghigo has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Pierre-Yves Lagrée
Sorbonne University
10 shared publications Jose-Maria Fullana
4 shared publications- José Maria Fullana
Department of Mechanical Engineering, Institut Jean Le Rond d'Alembert, UMR 7190, Sorbonne Université, CNRS, Paris 75005, France
3 shared publications - Jose-Maria Fullana
Sorbonne Université, UPMC UnivParis06, CNRS, UMR7190, Institut Jean Le Rond d'Alembert, 75005, Paris, France
2 shared publications - María Teresa Politi
Universidad de Buenos Aires
2 shared publications - Olivier Delestre
Science du sol INRA 0272 UR
2 shared publications
Latest Publications
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Reduced-order models for blood flow in networks of large arteries
Modèles simplifiés d’écoulements sanguins appliqués à des réseaux de grandes artères: La contraction périodique du coeur est à l’origine de l’onde de pouls qui, de part son interaction avec les artères élastiques, le sang et le réseau artériel lui-même, devient le signal observé quotidiennement par les médecins. Cette dynamique ondulatoire est d’une importance primordiale dans la compréhension de la genèse de nombreuses maladies cardiovasculaires. En effet, ce sont souvent des facteurs hémodynamiques qui sont à l’origine de la croissance de ces pathologies. Malheureusement, les mesures non-invasives et l’imagerie médicale sont souvent insuffisantes pour appréhender la complexité des écoulements sanguins. La simulation numérique est donc en plein essor car celle-ci permet d’obtenir des données précises dans des régions vasculaires difficiles d’accès. Bien que les modèles sanguins tridimensionnels soient très précis et permettent de reproduire fidèlement la géométrie vasculaire, leur coût, à la fois numérique et paramétrique, est trop important pour que ceux-ci soient utilisés dans de grands réseaux vasculaires. Nous avons donc choisi d’utiliser des modèles simplifiés qui permettent d’accéder à cette dynamique de réseau si importante. Premièrement, nous nous sommes intéressés aux modèles unidimensionnels et nous avons développé de nouvelles approches permettant de prendre en compte l’aspect non-Newtonien du sang et la viscoélasticité des parois artérielles. Secondement, nous avons proposé un modèle bidimensionnel, que nous avons utilisé pour simuler l’écoulement dans des sténoses et anévrismes. Finalement, nous avons utilisé ces modèles pour décrire l’écoulement du sang dans de grands réseaux artériels et pour optimiser un pontage extracorporel.
- 2 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Reduced-order models for blood flow in networks of large arteries
Modèles simplifiés d’écoulements sanguins appliqués à des réseaux de grandes artères: La contraction périodique du coeur est à l’origine de l’onde de pouls qui, de part son interaction avec les artères élastiques, le sang et le réseau artériel lui-même, devient le signal observé quotidiennement par les médecins. Cette dynamique ondulatoire est d’une importance primordiale dans la compréhension de la genèse de nombreuses maladies cardiovasculaires. En effet, ce sont souvent des facteurs hémodynamiques qui sont à l’origine de la croissance de ces pathologies. Malheureusement, les mesures non-invasives et l’imagerie médicale sont souvent insuffisantes pour appréhender la complexité des écoulements sanguins. La simulation numérique est donc en plein essor car celle-ci permet d’obtenir des données précises dans des régions vasculaires difficiles d’accès. Bien que les modèles sanguins tridimensionnels soient très précis et permettent de reproduire fidèlement la géométrie vasculaire, leur coût, à la fois numérique et paramétrique, est trop important pour que ceux-ci soient utilisés dans de grands réseaux vasculaires. Nous avons donc choisi d’utiliser des modèles simplifiés qui permettent d’accéder à cette dynamique de réseau si importante. Premièrement, nous nous sommes intéressés aux modèles unidimensionnels et nous avons développé de nouvelles approches permettant de prendre en compte l’aspect non-Newtonien du sang et la viscoélasticité des parois artérielles. Secondement, nous avons proposé un modèle bidimensionnel, que nous avons utilisé pour simuler l’écoulement dans des sténoses et anévrismes. Finalement, nous avons utilisé ces modèles pour décrire l’écoulement du sang dans de grands réseaux artériels et pour optimiser un pontage extracorporel.
- 1 December 2017
- Published by Elsevier in Journal of Computational Physics
- Vol. 350, 136-165
A 2D nonlinear multiring model for blood flow in large elastic arteries
- 1 December 2017
- Published by Elsevier in Journal of Computational Physics
- Vol. 350, 136-165
A 2D nonlinear multiring model for blood flow in large elastic arteries
- 11 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 43 (1) , 39-47
A one-dimensional arterial network model for bypass graft assessment
We propose an arterial network model based on one-dimensional hemodynamic equations to study the behavior of different vascular surgical bypass grafts in the case of an arterial occlusive pathology: a stenosis of the Right Iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obstruction of the stenosis. Numerical simulations show that all bypass grafts are efficient since we retrieve in each case the healthy hemodynamics downstream of the stenosed region while ensuring at the same time a global healthy circulation. We analyze in detail the behavior of the Axillo-Femoral bypass graft by performing hundreds of simulations where we vary the values of its Young's modulus [0.1-50 MPa] and radius [0.01-5 cm]. Our analysis shows that Young's modulus and radius of commercial bypass grafts are optimal in terms of hemodynamic considerations. Our numerical findings prove that this model approach can be used to optimize or plan patient-specific surgeries, to numerically assess the viability of bypass grafts and to perform parametric analysis and error propagation evaluations by running extensive simulations.
- 11 March 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 43 (1) , 39-47
A one-dimensional arterial network model for bypass graft assessment
We propose an arterial network model based on one-dimensional hemodynamic equations to study the behavior of different vascular surgical bypass grafts in the case of an arterial occlusive pathology: a stenosis of the Right Iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obstruction of the stenosis. Numerical simulations show that all bypass grafts are efficient since we retrieve in each case the healthy hemodynamics downstream of the stenosed region while ensuring at the same time a global healthy circulation. We analyze in detail the behavior of the Axillo-Femoral bypass graft by performing hundreds of simulations where we vary the values of its Young's modulus [0.1-50 MPa] and radius [0.01-5 cm]. Our analysis shows that Young's modulus and radius of commercial bypass grafts are optimal in terms of hemodynamic considerations. Our numerical findings prove that this model approach can be used to optimize or plan patient-specific surgeries, to numerically assess the viability of bypass grafts and to perform parametric analysis and error propagation evaluations by running extensive simulations.
- Open Access
One-dimensional Arterial Network Model for Bypass Grafts Assessment
We propose an arterial network model based on 1D blood hemodynamic equations to study the behavior of different vascular surgical bypass grafts in case of an arterial occlusive pathology: an obliteration or stenosis of the iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obliteration of the stenosis. Numerical simulations show that all bypass grafts are efficient since we retrieve in all cases the normal hemodynamics in the stenosed region while ensuring at the same time a global healthy circulation. We analyze in particular the Axillo-Femoral bypass graft by performing hundreds of simulations by varying the values of the Young's modulus [0.1--50 MPa] and the radius [0.01--5 cm] of the bypass graft. We show that the Young's modulus and radius of commercial bypass grafts are optimal in terms of hemodynamic considerations. The numerical findings prove that this approach could be used to optimize or plan surgeries for specific patients, to perform parameter's statistics and error propagation evaluations by running extensive simulations, or to characterize numerically specific bypass grafts.
Open AccessOne-dimensional Arterial Network Model for Bypass Grafts Assessment
We propose an arterial network model based on 1D blood hemodynamic equations to study the behavior of different vascular surgical bypass grafts in case of an arterial occlusive pathology: an obliteration or stenosis of the iliac artery. We investigate the performances of three different bypass grafts (Aorto-Femoral, Axillo-Femoral and cross-over Femoral) depending on the degree of obliteration of the stenosis. Numerical simulations show that all bypass grafts are efficient since we retrieve in all cases the normal hemodynamics in the stenosed region while ensuring at the same time a global healthy circulation. We analyze in particular the Axillo-Femoral bypass graft by performing hundreds of simulations by varying the values of the Young's modulus [0.1--50 MPa] and the radius [0.01--5 cm] of the bypass graft. We show that the Young's modulus and radius of commercial bypass grafts are optimal in terms of hemodynamic considerations. The numerical findings prove that this approach could be used to optimize or plan surgeries for specific patients, to perform parameter's statistics and error propagation evaluations by running extensive simulations, or to characterize numerically specific bypass grafts.
- 25 November 2016
- Published by Elsevier in Journal of Computational Physics
- Vol. 331, 108-136
Low-Shapiro hydrostatic reconstruction technique for blood flow simulation in large arteries with varying geometrical and mechanical properties
- 25 November 2016
- Published by Elsevier in Journal of Computational Physics
- Vol. 331, 108-136
Low-Shapiro hydrostatic reconstruction technique for blood flow simulation in large arteries with varying geometrical and mechanical properties
- 4 November 2016
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 139 (1) , 011003
Linear and Nonlinear Viscoelastic Arterial Wall Models: Application on Animals
This work deals with the viscoelasticity of the arterial wall and its influence on the pulse waves. We describe the viscoelasticity by a nonlinear Kelvin–Voigt model in which the coefficients are fitted using experimental time series of pressure and radius measured on a sheep's arterial network. We obtained a good agreement between the results of the nonlinear Kelvin–Voigt model and the experimental measurements. We found that the viscoelastic relaxation time—defined by the ratio between the viscoelastic coefficient and the Young's modulus—is nearly constant throughout the network. Therefore, as it is well known that smaller arteries are stiffer, the viscoelastic coefficient rises when approaching the peripheral sites to compensate the rise of the Young's modulus, resulting in a higher damping effect. We incorporated the fitted viscoelastic coefficients in a nonlinear 1D fluid model to compute the pulse waves in the network. The damping effect of viscoelasticity on the high-frequency waves is clear especially at the peripheral sites.
- 4 November 2016
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 139 (1) , 011003
Linear and Nonlinear Viscoelastic Arterial Wall Models: Application on Animals
This work deals with the viscoelasticity of the arterial wall and its influence on the pulse waves. We describe the viscoelasticity by a nonlinear Kelvin–Voigt model in which the coefficients are fitted using experimental time series of pressure and radius measured on a sheep's arterial network. We obtained a good agreement between the results of the nonlinear Kelvin–Voigt model and the experimental measurements. We found that the viscoelastic relaxation time—defined by the ratio between the viscoelastic coefficient and the Young's modulus—is nearly constant throughout the network. Therefore, as it is well known that smaller arteries are stiffer, the viscoelastic coefficient rises when approaching the peripheral sites to compensate the rise of the Young's modulus, resulting in a higher damping effect. We incorporated the fitted viscoelastic coefficients in a nonlinear 1D fluid model to compute the pulse waves in the network. The damping effect of viscoelasticity on the high-frequency waves is clear especially at the peripheral sites.
- Open Access
An analytic solution for blood flow in an artery with varying geometrical and mechanical properties
In this note, we present an analytic/exact solution of the one-dimensional model for blood flow. This solution describes the oscillation of a pulse wave in an artery with varying characteristics: cross-sectional area at rest and arterial wall rigidity. It is useful for the validation of numerical methods, especially well-balanced numerical methods.
Open AccessAn analytic solution for blood flow in an artery with varying geometrical and mechanical properties
In this note, we present an analytic/exact solution of the one-dimensional model for blood flow. This solution describes the oscillation of a pulse wave in an artery with varying characteristics: cross-sectional area at rest and arterial wall rigidity. It is useful for the validation of numerical methods, especially well-balanced numerical methods.
- 5 October 2016
- Published by Springer Nature in Health and Technology
- Vol. 6 (3) , 229-237
Impact of arterial cross-clamping during vascular surgery on arterial stiffness measured by the augmentation index and fractal dimension of arterial pressure
- 5 October 2016
- Published by Springer Nature in Health and Technology
- Vol. 6 (3) , 229-237
Impact of arterial cross-clamping during vascular surgery on arterial stiffness measured by the augmentation index and fractal dimension of arterial pressure
- 1 May 2016
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 72, 54-64
The dicrotic notch analyzed by a numerical model
- 1 May 2016
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 72, 54-64
The dicrotic notch analyzed by a numerical model