SLSheng Liu

Sheng Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sheng Liu has a total of 113 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Turret-based multiscale oblique plane microscopy

    by Chitra Shaji, Sheng Liu, Balasubramanian Chellammal Muthubharathi, Nikhil Sain, Wishwa Herath, Aadil Qadir Bhat, Tae-Hyung Kim, Olga Ponomarova, Tonmoy Chakraborty

    Oblique plane microscopy (OPM) has transformed light-sheet imaging, yet single-objective systems typically trade resolution for field of view. We present multiscale OPM that incorporates two turret-mounted objectives, allowing rapid switching between imaging modes. The 1.35 NA objective provides subcellular resolution, while the 0.75 NA objective enables wide-field coverage of spatially extended biological events. Switching modes requires only turret rotation and adjustment of the remote-focusing lens, while preserving the intrinsic strengths of OPM, including high-speed volumetric acquisition, low phototoxicity, and compatibility with standard sample formats. By combining wide-field and high-resolution imaging in a single platform, this system enables multiscale interrogation of dynamic biological processes without the need for multiple microscopes or complex realignment, as demonstrated through imaging of multiple Caenorhabditis elegans specimens and cultured cell lines.

  • Open Access

    Separation estimation of two freely rotating dipole emitters near the quantum limit

    by Sheng Liu, Sujeet Pani, Sajjad A. Khan, Francisco E. Becerra, Keith A. Lidke

    According to Rayleigh's criterion, two incoherent emitters with a separation below the diffraction limit are not resolvable with a conventional fluorescence microscope. One method of superresolution microscopy (SRM) circumvents the diffraction-limited resolution by precisely estimating the position of spatiotemporally independent emitters. However, these methods of SRM techniques are not optimal for estimating the separation of two simultaneously excited emitters. Recently, a number of detection methods based on modal imaging have been developed to achieve the quantum Cramér-Rao lower bound (QCRB) to estimate the separations between two nearby emitters. The QCRB determines the minimum achievable precision for all possible detection methods. Current modal imaging techniques assume a scalar field generated from a point source, such as a distant source from an optical fiber or a pinhole. However, for fluorescently labeled samples, point emitters are single fluorophores that are modeled as dipole emitters and, in practice, are often freely rotating. Dipole radiation must be described by vectorial theory, and the assumption of a scalar field no longer holds. Here, we present a method to numerically calculate the QCRB for measuring the separation of two dipole emitters, incorporating the vectorial theory. Furthermore, we propose a near-quantum optimal detection scheme based on one of the modal imaging techniques, superlocalization by image inversion interferometry (SLIVER), for estimating the separation of two freely rotating dipoles. In the proposed method, we introduce a vortex wave plate before the SLIVER detection to separate the radial and azimuthal components of the dipole radiation. With numerical simulations, we demonstrated that our method achieves nondivergent precision at any separation between two dipole emitters. We investigated several practical effects relevant to experimental measurements in superresolution microscopy, including numerical aperture, detection bandwidth, number of estimation parameters, background, and misalignment on separation estimation. Our proposed measurement provides a near-quantum-limited detection scheme for measuring the separation of two freely rotating dipole emitters, such as fluorescently tagged molecules, which are commonly used in superresolution microscopy.

  • Enhanced supercritical angle localization microscopy through point spread function modeling

    by Sajjad A. Khan, Keith A. Lidke, Sheng Liu

    Single-molecule localization microscopy (SMLM) enables precise spatial localization of single molecules in cellular structures. A phenomenon called supercritical angle fluorescence (SAF) is utilized in SMLM (SAF-SMLM) to estimate the axial positions of single fluorophores. It is based on the fact that SAF intensity is highly sensitive to the fluorophore-coverslip distance. Conventional SAF-SMLM methods typically involve splitting the fluorescence emission into supercritical and undercritical components, which requires a complicated two-channel system and can lead to reduced light efficiency. In this work, we introduce a simplified approach to traditional SAF-SMLM by directly detecting all fluorescence into a single channel. Through simulations, we found that by accurately modeling the point spread function (PSF) with SAF, a single-channel system achieves better localization precision than two-channel-based SAF-SMLM systems. Furthermore, we developed a stage-tilt correction algorithm, incorporating stage tilt in the PSF model, to improve axial precision over the entire field of view. We applied our method experimentally by imaging F-actin filaments in HeLa cells. We demonstrate that our method efficiently exploits the information from SAF and achieves enhanced axial localization precision and accuracy compared to traditional SMLM localization methods for single-channel systems.


  • Upsampled PSF enables high accuracy 3D superresolution imaging with sparse sampling rate

    by Jianwei Chen, Wei Shi, Jianzheng Feng, Jianlin Wang, Sheng Liu, Yiming Li

    Single-molecule localization microscopy (SMLM) provides nanoscale imaging, but pixel integration of acquired SMLM images limited the choice of sampling rate, which restricts the information content conveyed within each image. We propose an upsampled point spread function (PSF) inverse modeling method for large-pixel single-molecule localization, enabling precise three-dimensional superresolution imaging with a sparse sampling rate. Our approach could reduce data volume or expand the field of view by nearly an order of magnitude, while maintaining high localization accuracy and greatly improving the imaging throughput with the limited pixels available in existing cameras.


  • Open Access

    A MATLAB-based Instrument Control (MIC) package for fluorescence imaging

    by Sajjad A. Khan, Sandeep Pallikkuth, David J. Schodt, Marjolein B. M. Meddens, Hanieh Mazloom-Farsibaf, Michael J. Wester, Sheng Liu, Ellyse Taylor, Mohamadreza Fazel, Farzin Farzam, et al.

    MATLAB Instrument Control (MIC) is a software package designed to facilitate data collection for custom-built microscopes. Utilizing object-oriented programming, MIC provides a class for each low-level instrument. These classes inherit from a common MIC abstract class, ensuring a uniform interface across different instruments. Key components such as lasers, stages, power meter and cameras are grouped under abstract subclasses, which standardize interfaces and simplify the development of control classes for new instruments. Both simple and complex systems can be built from these lower level tools. Since the interoperation is developed by the end user, the modes or sequence of operations can be flexibly designed with interactive or automated data collection and integrated analysis. MATLAB provides the ability to create GUIs and therefore MIC allows for both rapid prototyping and for building custom, high-level user interfaces that can be used for production instruments.


  • Open Access

    Separation estimation of two freely rotating dipole emitters near the quantum limit

    by Sheng Liu, Sujeet Pani, Sajjad A. Khan, Francisco E. Becerra, Keith A. Lidke

    According to Rayleigh’s criterion, two incoherent emitters with a separation below the diffraction limit are not resolvable with a conventional fluorescence microscope. One method of Super-Resolution Microscopy (SRM) circumvents the diffraction-limited resolution by precisely estimating the position of spatiotemporally independent emitters. However, these methods of SRM techniques are not optimal for estimating the separation of two simultaneously excited emitters. Recently, a number of detection methods based on modal imaging have been developed to achieve the quantum Cramér-Rao lower bound (QCRB) to estimate the separations between two nearby emitters. The QCRB determines the minimum achievable precision for all possible detection methods. Current modal imaging techniques assume a scalar field generated from a point source, such as a distant source from an optical fiber or a pinhole. However, for fluorescently labeled samples, point emitters are single fluorophores that are modeled as dipole emitters and, in practice, are often freely rotating. Dipole radiation must be described by vectorial theory, and the assumption of a scalar field no longer holds. Here, we present a method to numerically calculate the QCRB for measuring the separation of two dipole emitters, incorporating the vectorial theory. Furthermore, we propose a near-quantum optimal detection scheme based on one of the modal imaging techniques, super-localization by image inversion interferometry (SLIVER), for estimating the separation of two freely rotating dipoles. In the proposed method, we introduce a vortex wave plate before the SLIVER detection to separate the radial and azimuthal components of the dipole radiation. With numerical simulations, we demonstrated that our method achieves non-divergent precision at any separation between two dipole emitters. We investigated several practical effects relevant to experimental measurements in super-resolution microscopy, including numerical aperture, detection bandwidth, number of estimation parameters, background, and misalignment on separation estimation. Our proposed measurement provides a near quantum-limited detection scheme for measuring the separation of two freely-rotating dipole emitters, such as fluorescently tagged molecules, which are commonly used in super-resolution microscopy.


  • Fast and universal single-molecule localization using multi-dimensional point spread functions

    by Mengfan Li, Wei Shi, Sheng Liu, Shuang Fu, Yue Fei, Lulu Zhou, Ke Fang, Yiming Li

    The recent development of single-molecule imaging techniques has enabled not only high accuracy spatial resolution imaging but also information rich functional imaging. Abundant information about single molecules can be encoded in its diffraction pattern and be extracted precisely (e.g. 3D position, wavelength, dipole orientation). However, sophisticated high dimensional point spread function (PSF) modeling and analyzing methods have greatly impeded the broad accessibility of these techniques. Here, we present a graphics processing unit (GPU) -based B-spline PSF modeling method that could flexibly model high dimensional PSFs with arbitrary shape without greatly increasing the model parameters. Our B-spline fitter achieves 100 times speed improvement and minimal uncertainty for each dimension, enabling efficient high dimensional single-molecule analysis. We demonstrated, both in simulations and experiments, the universality and flexibility of our B-spline fitter to accurately extract the abundant information from different types of high dimensional single-molecule data, including multicolor PSF (3D + color), multi-channel four-dimensional 4Pi-PSF (3D + interference phase) and five-dimensional vortex PSF (3D + dipole orientation).


  • Open Access

    Up sampled PSF enables high accuracy 3D super-resolution imaging with sparse sampling rate

    by Jianwei Chen, Wei Shi, Jianzheng Feng, Jianlin Wang, Sheng Liu, Yiming Li

    Single-molecule localization microscopy (SMLM) provides nanoscale imaging, but pixel integration of acquired SMLM images limited the choice of sample rate which restricts the information content conveyed within each image. We propose an up-sampled point spread function (PSF) inverse modeling method for large-pixel single molecule localization, enabling precise 3D super-resolution imaging with sparse sampling rate. Our approach could reduce data volume or expand the field of view by nearly an order of magnitude, while maintaining high localization accuracy, greatly improving the imaging throughput with limited pixels offered by the existing cameras.

  • Open Access

    Axial de-scanning using remote focusing in the detection arm of light-sheet microscopy

    by Hassan Dibaji, Ali Kazemi Nasaban Shotorban, Rachel M. Grattan, Shayna Lucero, David J. Schodt, Keith A. Lidke, Jonathan Petruccelli, Diane S. Lidke, Sheng Liu, Tonmoy Chakraborty

    Rapid, high-resolution volumetric imaging without moving heavy objectives or disturbing delicate samples remains challenging. Pupil-matched remote focusing offers a promising solution for high NA systems, but the fluorescence signal’s incoherent and unpolarized nature complicates its application. Thus, remote focusing is mainly used in the illumination arm with polarized laser light to improve optical coupling. Here, we introduce a novel optical design that can de-scan the axial focus movement in the detection arm of a microscope. Our method splits the fluorescence signal into S and P-polarized light, lets them pass through the remote focusing module separately, and combines them with the camera. This allows us to use only one focusing element to perform aberration-free, multi-color, volumetric imaging without (a) compromising the fluorescent signal and (b) needing to perform sample/detection-objective translation. We demonstrate the capabilities of this scheme by acquiring fast dual-color 4D (3D space + time) image stacks with an axial range of 70 μm and camera-limited acquisition speed. Owing to its general nature, we believe this technique will find its application in many other microscopy techniques that currently use an adjustable Z-stage to carry out volumetric imaging, such as confocal, 2-photon, and light sheet variants.


  • Universal inverse modeling of point spread functions for SMLM localization and microscope characterization

    by Sheng Liu, Jianwei Chen, Jonas Hellgoth, Lucas-Raphael Müller, Boris Ferdman, Christian Karras, Dafei Xiao, Keith A. Lidke, Rainer Heintzmann, Yoav Shechtman, et al.

    The point spread function (PSF) of a microscope describes the image of a point emitter. Knowing the accurate PSF model is essential for various imaging tasks, including single-molecule localization, aberration correction and deconvolution. Here we present universal inverse modeling of point spread functions (uiPSF), a toolbox to infer accurate PSF models from microscopy data, using either image stacks of fluorescent beads or directly images of blinking fluorophores, the raw data in single-molecule localization microscopy (SMLM). Our modular framework is applicable to a variety of microscope modalities and the PSF model incorporates system- or sample-specific characteristics, for example, the bead size, field- and depth- dependent aberrations, and transformations among channels. We demonstrate its application in single or multiple channels or large field-of-view SMLM systems, 4Pi-SMLM, and lattice light-sheet microscopes using either bead data or single-molecule blinking data.