Chutham Sawigun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Chutham Sawigun has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Surachoke Thanapitak
Faculty of Engineering, Mahidol University, Salaya, Thailand
6 shared publications - Carolina Mora Lopez
IMEC
2 shared publications - Xiaolin Yang
IMEC, Leuven, Belgium
2 shared publications - Andrea Cossettini
Department of Information Technology and Electrical Engineering (D-ITET), ETH Zrich, Zrich, Switzerland
1 shared publication - Aris Siskos
Electrical Engineering Department ESAT, KU Leuven, Leuven, Belgium
1 shared publication - Chen Wang
IMEC, Leuven, Belgium
1 shared publication
Latest Publications
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (4) , 526-527
Guest Editorial—Special Section on Selected Papers From IEEE BioCAS 2025
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (4) , 526-527
Guest Editorial—Special Section on Selected Papers From IEEE BioCAS 2025
- Open Access
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. PP, 1
A High-Gain, Low-Voltage Operational Amplifier With Bias-Stress and PVT Robustness for Large-Area Temperature Sensing on LTPS Substrates
This paper analyzes the temperature coefficients of low temperature polysilicon (LTPS) devices and investigates critical blocks of a system architecture for large-area temperature sensing, which integrates sensors and readout circuits monolithically. As part of this system, a low-voltage folded-cascode (LV-FC) operational amplifier (OpAmp) with a class-AB output stage was designed and implemented using an LTPS thin film transistor (TFT) process on a 15μm-thick polyimide flexible substrate. The performance of 20 amplifier samples was thoroughly characterized under DC, AC, long-term bias-stress (up to 40,000 seconds), and temperature conditions (0∘C to 80∘C). The amplifier achieves a maximum DC gain of 64.2 dB and a gain-bandwidth product of 400 kHz, while operating reliably under a 6 V supply with a peak power consumption of 0.6 mW in a compact area of 1.38 mm2. Under bias stress, the gain degraded by only 2.5 dB and the offset shifted by 1.5 mV. Over the full temperature range, the average gain varied by less than 2 dB and the offset by under 6 mV. These results demonstrate strong robustness against PVT variations and prolonged stress, confirming the suitability of the proposed LV-FC amplifier for flexible, long-term, and large-area temperature sensing applications.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Circuits and Systems
- Vol. PP, 1
Open AccessA High-Gain, Low-Voltage Operational Amplifier With Bias-Stress and PVT Robustness for Large-Area Temperature Sensing on LTPS Substrates
This paper analyzes the temperature coefficients of low temperature polysilicon (LTPS) devices and investigates critical blocks of a system architecture for large-area temperature sensing, which integrates sensors and readout circuits monolithically. As part of this system, a low-voltage folded-cascode (LV-FC) operational amplifier (OpAmp) with a class-AB output stage was designed and implemented using an LTPS thin film transistor (TFT) process on a 15μm-thick polyimide flexible substrate. The performance of 20 amplifier samples was thoroughly characterized under DC, AC, long-term bias-stress (up to 40,000 seconds), and temperature conditions (0∘C to 80∘C). The amplifier achieves a maximum DC gain of 64.2 dB and a gain-bandwidth product of 400 kHz, while operating reliably under a 6 V supply with a peak power consumption of 0.6 mW in a compact area of 1.38 mm2. Under bias stress, the gain degraded by only 2.5 dB and the offset shifted by 1.5 mV. Over the full temperature range, the average gain varied by less than 2 dB and the offset by under 6 mV. These results demonstrate strong robustness against PVT variations and prolonged stress, confirming the suitability of the proposed LV-FC amplifier for flexible, long-term, and large-area temperature sensing applications.
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Magazine
- Vol. 15 (4) , 50-57
Ultra-Low-Power Voltage References: Exploring picowatt-level design using CMOS and hybrid architectures
Voltage references (VRs) play a crucial role in the PMUs of electronic systems, providing a stable voltage regardless of process variations, supply voltage fluctuations, and temperature changes. The BGR has been widely employed as a reliable VR since the 1980s [1] , delivering approximately 1.2 V based on the silicon bandgap voltage ( V BG ). However, designing a low-power and compact BGR presents challenges because of the power–area tradeoff [2] .
- 16 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Magazine
- Vol. 15 (4) , 50-57
Ultra-Low-Power Voltage References: Exploring picowatt-level design using CMOS and hybrid architectures
Voltage references (VRs) play a crucial role in the PMUs of electronic systems, providing a stable voltage regardless of process variations, supply voltage fluctuations, and temperature changes. The BGR has been widely employed as a reliable VR since the 1980s [1] , delivering approximately 1.2 V based on the silicon bandgap voltage ( V BG ). However, designing a low-power and compact BGR presents challenges because of the power–area tradeoff [2] .
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 458-469
A Micropower Chopper CBIA Using DSL-Embedded Input Stage With 0.4 V EO Tolerance for Dry-Electrode Biopotential Recording
A chopper instrumentation amplifier (IA) dedicated for bio-potential acquisition usually requires a linearized input stage for large electrode offset voltage accommodation. This linearization leads to excessive power consumption when sufficiently low input-referred noise (IRN) is required. We present a current-balance IA (CBIA) without the need for the input stage linearization. It uses two transistors to operate as an input transconductance stage and a dc-servo loop (DSL) at the same time. An off-chip capacitor completes the DSL by ac coupling the source terminals of the input transistors via chopping switches realizing a sub-Hz high-pass cutoff frequency for dc rejection. Fabricated in a 0.35-μm CMOS process, the proposed CBIA occupies 0.41 mm 2 and consumes 1.19 μW from a 3 V dc supply. Measurements show that the IA achieves an input-referred noise of 0.91 μV rms over 100 Hz bandwidth. This corresponds to a noise efficiency factor of 2.22. Typical CMRR of 102.1 dB is achieved for zero offset and degraded to 85.9 dB when a ±0.3 V input offset was applied. Gain variation of 0.5% is maintained within the range of ±0.4 V input offset. The resulting performance meets well with the requirement for ECG and EEG recording using dry electrodes. A demonstration for the use of the proposed IA on a human subject is also provided.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (3) , 458-469
A Micropower Chopper CBIA Using DSL-Embedded Input Stage With 0.4 V EO Tolerance for Dry-Electrode Biopotential Recording
A chopper instrumentation amplifier (IA) dedicated for bio-potential acquisition usually requires a linearized input stage for large electrode offset voltage accommodation. This linearization leads to excessive power consumption when sufficiently low input-referred noise (IRN) is required. We present a current-balance IA (CBIA) without the need for the input stage linearization. It uses two transistors to operate as an input transconductance stage and a dc-servo loop (DSL) at the same time. An off-chip capacitor completes the DSL by ac coupling the source terminals of the input transistors via chopping switches realizing a sub-Hz high-pass cutoff frequency for dc rejection. Fabricated in a 0.35-μm CMOS process, the proposed CBIA occupies 0.41 mm 2 and consumes 1.19 μW from a 3 V dc supply. Measurements show that the IA achieves an input-referred noise of 0.91 μV rms over 100 Hz bandwidth. This corresponds to a noise efficiency factor of 2.22. Typical CMRR of 102.1 dB is achieved for zero offset and degraded to 85.9 dB when a ±0.3 V input offset was applied. Gain variation of 0.5% is maintained within the range of ±0.4 V input offset. The resulting performance meets well with the requirement for ECG and EEG recording using dry electrodes. A demonstration for the use of the proposed IA on a human subject is also provided.
- Open Access
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 1, 67-78
A Compact Chopper Stabilized Δ-ΔΣ Neural Readout IC With Input Impedance Boosting
This paper presents a scalable neural recording analog front-end architecture enabling simultaneous acquisition of action potentials, local field potentials, electrode DC offsets and stimulation artifacts without saturation. By combining a DC-coupled$\Delta $ -$\Delta \Sigma $ architecture with new bootstrapping and chopping schemes, the proposed readout IC achieves an area of 0.0077 mm 2 per channel, an input-referred noise of 5.53 ± 0.36$\mu \text{V}_{\mathrm{ rms}}$ in the action potential band and 2.88 ± 0.18$\mu \text{V}_{\mathrm{ rms}}$ in the local field potential band, a dynamic range of 77 dB, an electrode-DC-offset tolerance of ±70 mV and an input impedance of 663$\text{M}\Omega $ . To validate this neural readout architecture, we fabricated a 16-channel proof of-concept IC and validated it in an in vitro setting, demonstrating the capability to record extracellular signals even when using small, high-impedance electrodes. Because of the small area achieved, this architecture can be used to implement ultra-high-density neural probes for large-scale electrophysiology.- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 1, 67-78
Open AccessA Compact Chopper Stabilized Δ-ΔΣ Neural Readout IC With Input Impedance Boosting
This paper presents a scalable neural recording analog front-end architecture enabling simultaneous acquisition of action potentials, local field potentials, electrode DC offsets and stimulation artifacts without saturation. By combining a DC-coupled$\Delta $ -$\Delta \Sigma $ architecture with new bootstrapping and chopping schemes, the proposed readout IC achieves an area of 0.0077 mm 2 per channel, an input-referred noise of 5.53 ± 0.36$\mu \text{V}_{\mathrm{ rms}}$ in the action potential band and 2.88 ± 0.18$\mu \text{V}_{\mathrm{ rms}}$ in the local field potential band, a dynamic range of 77 dB, an electrode-DC-offset tolerance of ±70 mV and an input impedance of 663$\text{M}\Omega $ . To validate this neural readout architecture, we fabricated a 16-channel proof of-concept IC and validated it in an in vitro setting, demonstrating the capability to record extracellular signals even when using small, high-impedance electrodes. Because of the small area achieved, this architecture can be used to implement ultra-high-density neural probes for large-scale electrophysiology. - 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (3) , 549-558
A Compact Sub-μW CMOS ECG Amplifier With 57.5-MΩ Zin, 2.02 NEF, 8.16 PEF and 83.24-dB CMRR
This paper presents a compact DDA-based fully-differential CMOS instrumentation amplifier dedicated for micro-power ECG monitoring. Only eight transistors are employed to realize a power-efficient current-sharing DDA. A RC network (using MOS pseudo resistors and poly capacitors) forms feedback loops around the DDA creating an ac-only amplification. The proposed amplifier is dc-coupled via gate terminals of the p-channel input transistors. It thus achieves sufficiently high input impedance over the entire ECG frequency range. Fabricated in a 0.35-μm CMOS process, the proposed amplifier occupies 0.0712 mm 2 . It operates from a 2 V dc supply with 336 nA current consumption. Measurements show that the amplifier attains its input impedance of 57.5 MΩ at 150 Hz and achieves 1.54 μV rms input-referred noise over 0.1-300 Hz. Noise and power efficiency factors are 2.02 and 8.16, respectively. At 50 Hz, the mean CMRR of 83.24 dB is obtained from 11-chip measurement. Experiments performed on a human subject confirm the functionality of the proposed amplifier in a real measurement scenario.
- 3 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (3) , 549-558
A Compact Sub-μW CMOS ECG Amplifier With 57.5-MΩ Zin, 2.02 NEF, 8.16 PEF and 83.24-dB CMRR
This paper presents a compact DDA-based fully-differential CMOS instrumentation amplifier dedicated for micro-power ECG monitoring. Only eight transistors are employed to realize a power-efficient current-sharing DDA. A RC network (using MOS pseudo resistors and poly capacitors) forms feedback loops around the DDA creating an ac-only amplification. The proposed amplifier is dc-coupled via gate terminals of the p-channel input transistors. It thus achieves sufficiently high input impedance over the entire ECG frequency range. Fabricated in a 0.35-μm CMOS process, the proposed amplifier occupies 0.0712 mm 2 . It operates from a 2 V dc supply with 336 nA current consumption. Measurements show that the amplifier attains its input impedance of 57.5 MΩ at 150 Hz and achieves 1.54 μV rms input-referred noise over 0.1-300 Hz. Noise and power efficiency factors are 2.02 and 8.16, respectively. At 50 Hz, the mean CMRR of 83.24 dB is obtained from 11-chip measurement. Experiments performed on a human subject confirm the functionality of the proposed amplifier in a real measurement scenario.
- 24 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 66 (5) , 1746-1757
A Nanopower Biopotential Lowpass Filter Using Subthreshold Current-Reuse Biquads With Bulk Effect Self-Neutralization
A nanopower CMOS 4th-order lowpass filter suitable for biomedical applications is presented. The filter is formed by cascading two types of subthreshold current-reuse biquadratic cell. Each proposed cell is capable of neutralizing the bulk effect that induces the passband attenuation. The nearly 0-dB passband gain can thus be maintained, while the entire filter circuit remains compact and power-efficient. Designed for electrocardiogram detection as an example of application, the filter prototype has been fabricated in a 0.35 μm CMOS process occupying 269 μm x 383 μm chip area. Measurements verify that the filter can operate from a 1.5-V single supply and consumes 5.25 nW, while providing a cutoff frequency of 100 Hz and input-referred noise of 39.38 μVrms. The intermodulation-free dynamic range of 51.48 dB is obtained from a two-tone test of 50 and 60 Hz input frequencies. Compared with state-of-the-art nanopower lowpass filters using the most relevant and reasonable figure of merit, the proposed filter ranks the best.
- 24 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 66 (5) , 1746-1757
A Nanopower Biopotential Lowpass Filter Using Subthreshold Current-Reuse Biquads With Bulk Effect Self-Neutralization
A nanopower CMOS 4th-order lowpass filter suitable for biomedical applications is presented. The filter is formed by cascading two types of subthreshold current-reuse biquadratic cell. Each proposed cell is capable of neutralizing the bulk effect that induces the passband attenuation. The nearly 0-dB passband gain can thus be maintained, while the entire filter circuit remains compact and power-efficient. Designed for electrocardiogram detection as an example of application, the filter prototype has been fabricated in a 0.35 μm CMOS process occupying 269 μm x 383 μm chip area. Measurements verify that the filter can operate from a 1.5-V single supply and consumes 5.25 nW, while providing a cutoff frequency of 100 Hz and input-referred noise of 39.38 μVrms. The intermodulation-free dynamic range of 51.48 dB is obtained from a two-tone test of 50 and 60 Hz input frequencies. Compared with state-of-the-art nanopower lowpass filters using the most relevant and reasonable figure of merit, the proposed filter ranks the best.
- 29 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (11) , 2290-2298
A 0.9-nW, 101-Hz, and 46.3- $\mu$ Vrms IRN Low-Pass Filter for ECG Acquisition Using FVF BiquadsThis paper presents a differential fourth-order low-pass filter suitable for electrocardiography (ECG) acquisition. It is formed by cascading two compact and power-efficient biquads operating in the subthreshold region. Each biquad combines two capacitors and a flipped voltage follower circuit. The filter attains a cutoff frequency adjustable to cover the entire range of ECG (150–250 Hz). The filter prototype has been fabricated in a 0.35- $\mu \text{m}$ CMOS technology. It occupies an area of $362\,\,\mu \text {m} \times 466 \,\,\mu \text{m}$ and operates from a 0.6-V supply. Measurements confirm that the filter consumes 0.9-nW static power for a 101-Hz cutoff frequency and contributes the input-referred noise of 46.27 $\mu \text{V}_{\mathbf {rms}}$ . For a 60-Hz input frequency, the filter achieves a dynamic range of 47 dB where the third-harmonic distortion of −60 dB is produced. This leads to the figure of merit of $46.5 \times 10^{-18}$ J. When the chip area is also concerned, the proposed filter performs comparably to the recent state-of-the-art nanowatt-class low-pass filter.
- 29 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 26 (11) , 2290-2298
A 0.9-nW, 101-Hz, and 46.3- $\mu$ Vrms IRN Low-Pass Filter for ECG Acquisition Using FVF BiquadsThis paper presents a differential fourth-order low-pass filter suitable for electrocardiography (ECG) acquisition. It is formed by cascading two compact and power-efficient biquads operating in the subthreshold region. Each biquad combines two capacitors and a flipped voltage follower circuit. The filter attains a cutoff frequency adjustable to cover the entire range of ECG (150–250 Hz). The filter prototype has been fabricated in a 0.35- $\mu \text{m}$ CMOS technology. It occupies an area of $362\,\,\mu \text {m} \times 466 \,\,\mu \text{m}$ and operates from a 0.6-V supply. Measurements confirm that the filter consumes 0.9-nW static power for a 101-Hz cutoff frequency and contributes the input-referred noise of 46.27 $\mu \text{V}_{\mathbf {rms}}$ . For a 60-Hz input frequency, the filter achieves a dynamic range of 47 dB where the third-harmonic distortion of −60 dB is produced. This leads to the figure of merit of $46.5 \times 10^{-18}$ J. When the chip area is also concerned, the proposed filter performs comparably to the recent state-of-the-art nanowatt-class low-pass filter.
- 12 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 65 (9) , 2774-2783
A Subthreshold Buffer-Based Biquadratic Cell and its Application to Biopotential Filter Design
This paper develops a compact power-efficient CMOS buffer to operate as a nanopower lowpass biquadratic cell. Unlike other recently reported CMOS biquads with passband gains that are attenuated by the bulk effect, this biquad attains a near 0-dB passband gain without gain compensation. It acquires the same levels of input and output common-mode voltages making it useful for cascade realization of a higher order lowpass filter. To demonstrate the potential application of the proposed biquad, a fourth-order lowpass filter was designed based on the proposed biquad circuit and fabricated in the 0.35-μm CMOS process to serve electrocardiography readout systems. Measurement results show that the filter consumes 4.26-nW static power from a 0.9-V supply providing a 100-Hz cutoff frequency. The prototype chip occupies a silicon area of 0.11 mm² and contributes an input-referred noise of 80.5 μVrms. For a 60-Hz input frequency associated with -50-dB third-order harmonic distortion, a dynamic range of 48.2 dB is achieved. The lowest power supply rejection ratio of 40 dB was obtained at 100 Hz. Compared with the previous state-of-the-art designs in the category of nanopower filters, the proposed filter consumes the least power from the lowest supply voltage.
- 12 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 65 (9) , 2774-2783
A Subthreshold Buffer-Based Biquadratic Cell and its Application to Biopotential Filter Design
This paper develops a compact power-efficient CMOS buffer to operate as a nanopower lowpass biquadratic cell. Unlike other recently reported CMOS biquads with passband gains that are attenuated by the bulk effect, this biquad attains a near 0-dB passband gain without gain compensation. It acquires the same levels of input and output common-mode voltages making it useful for cascade realization of a higher order lowpass filter. To demonstrate the potential application of the proposed biquad, a fourth-order lowpass filter was designed based on the proposed biquad circuit and fabricated in the 0.35-μm CMOS process to serve electrocardiography readout systems. Measurement results show that the filter consumes 4.26-nW static power from a 0.9-V supply providing a 100-Hz cutoff frequency. The prototype chip occupies a silicon area of 0.11 mm² and contributes an input-referred noise of 80.5 μVrms. For a 60-Hz input frequency associated with -50-dB third-order harmonic distortion, a dynamic range of 48.2 dB is achieved. The lowest power supply rejection ratio of 40 dB was obtained at 100 Hz. Compared with the previous state-of-the-art designs in the category of nanopower filters, the proposed filter consumes the least power from the lowest supply voltage.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A 9.19 nW hybrid OTA — Source follower biquad lowpass filter
The hybrid fully differential second order Gm - C lowpass filter constructed from an operational transconductance amplifier and a PMOS source follower is presented in this paper. This proposed LPF is simulated using 0.35 μm standard CMOS process and consumes 9.19 nW at 1.5 V power supply for 100 Hz bandwidth. The bandwidth of this proposed LPF is tunable from 10 Hz to 1 kHz. The benchmarks between this LPF and the other recent work exhibit an improvement on linearity, dynamic range and FoM.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A 9.19 nW hybrid OTA — Source follower biquad lowpass filter
The hybrid fully differential second order Gm - C lowpass filter constructed from an operational transconductance amplifier and a PMOS source follower is presented in this paper. This proposed LPF is simulated using 0.35 μm standard CMOS process and consumes 9.19 nW at 1.5 V power supply for 100 Hz bandwidth. The bandwidth of this proposed LPF is tunable from 10 Hz to 1 kHz. The benchmarks between this LPF and the other recent work exhibit an improvement on linearity, dynamic range and FoM.