Victoria Anne Coleman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Victoria Anne Coleman has a total of 225 co-authors. Here are the top co-authors by number of shared publications:
- Chennupati Jagadish
The Australian National University
13 shared publications - Hark Hoe Tan
The Australian National University
8 shared publications Jan Herrmann
Nanometrology, National Measurement Institute Australia, PO Box 264, Lindfield, NSW 2070, Lindfield, New South Wales, 2070, AUSTRALIA
8 shared publicationsM. Inoue
Nanomaterials Microdevices Research Center, Osaka Institute of Technology, Asahi-ku Ohmiya, Osaka 535-8585, Japan
6 shared publicationsM. Yano
Nanomaterials Microdevices Research Center, Osaka Institute of Technology, Asahi-ku Ohmiya, Osaka 535-8585, Japan
6 shared publications- Jeffrey A. Davis
Optical Sciences Centre, Swinburne University of Technology, Hawthorn, 3122, Victoria, Australia
5 shared publications
Latest Publications
- Open Access
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Step height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.
- 12 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105018
Open AccessStep height measurement of monoatomic silicon crystal lattice steps with a commercial atomic force microscope
Precise control of advanced materials relies on accurate dimensional metrology at the sub-nanometre scale. At this scale, the accuracy of scanning probe microscopy (SPM) has been limited by the lack of traceable transfer standard artefacts with calibration structures of suitable dimensions. With the adoption in 2019 of the silicon crystal lattice spacing as a secondary realization of the metre in the International System of Units (SI), SPM users have direct access to a realization of the SI metre at the sub-nanometre level by means of the step height of self-assembled monatomic lattice steps that can form on the surface of silicon crystals. A key challenge of successfully adopting this pathway is establishing protocols to minimize measurement errors and artefacts in routine laboratory use. In this study, step height measurements of monoatomic lattice steps in an ordinal/staircase structure on a Si(111) crystal surface have been derived from images acquired with a commercially available, research-level atomic force microscope (AFM). Measurement results derived from AFM images using three different SPM image processing and analysis software packages are compared. Significant sources of measurement uncertainty are identified, principally the contribution from the dependence on scan direction. The calibration of the AFM derived from this measurement was used to traceably measure the sub-nanometre lattice steps on a silicon carbide crystal surface to demonstrate the viability of this calibration pathway.
- 16 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075007
Immersive visualisation for a large metrological data set
A purpose of scientific visualisation is to facilitate the extraction of information within underlying data. Visualisation of a large data set requires an appropriate visualisation method where, instead of focusing on expected features, all acquired data are treated on an equal footing. Here, we identify critical differences between raw and processed data acquired from displacement measurements at the nanoscale. We illustrate the strength of immersive data visualisation in rapidly and intuitively identifying non-obvious data trends, supported by correlation with the associated measurement uncertainties. These insights can be directly leveraged for optimisation of instrumentation and measurement protocols, application of appropriate measurement corrections, and iterative experimental design changes.
- 16 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075007
Immersive visualisation for a large metrological data set
A purpose of scientific visualisation is to facilitate the extraction of information within underlying data. Visualisation of a large data set requires an appropriate visualisation method where, instead of focusing on expected features, all acquired data are treated on an equal footing. Here, we identify critical differences between raw and processed data acquired from displacement measurements at the nanoscale. We illustrate the strength of immersive data visualisation in rapidly and intuitively identifying non-obvious data trends, supported by correlation with the associated measurement uncertainties. These insights can be directly leveraged for optimisation of instrumentation and measurement protocols, application of appropriate measurement corrections, and iterative experimental design changes.
- Open Access
- 16 March 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (22) , 225702
Thickness measurements of graphene oxide flakes using atomic force microscopy: results of an international interlaboratory comparison
Flake thickness is one of the defining properties of graphene-related 2D materials (GR2Ms), and therefore requires reliable, accurate, and reproducible measurements with well-understood uncertainties. This is needed regardless of the production method or manufacturer because it is important for all GR2M products to be globally comparable. An international interlaboratory comparison on thickness measurements of graphene oxide flakes using atomic force microscopy has been completed in technical working area 41 of versailles project on advanced materials and standards. Twelve laboratories participated in the comparison project, led by NIM, China, to improve the equivalence of thickness measurement for two-dimensional flakes. The measurement methods, uncertainty evaluation and a comparison of the results and analysis are reported in this manuscript. The data and results of this project will be directly used to support the development of an ISO standard.
- 16 March 2023
- Published by IOP Publishing in Nanotechnology
- Vol. 34 (22) , 225702
Open AccessThickness measurements of graphene oxide flakes using atomic force microscopy: results of an international interlaboratory comparison
Flake thickness is one of the defining properties of graphene-related 2D materials (GR2Ms), and therefore requires reliable, accurate, and reproducible measurements with well-understood uncertainties. This is needed regardless of the production method or manufacturer because it is important for all GR2M products to be globally comparable. An international interlaboratory comparison on thickness measurements of graphene oxide flakes using atomic force microscopy has been completed in technical working area 41 of versailles project on advanced materials and standards. Twelve laboratories participated in the comparison project, led by NIM, China, to improve the equivalence of thickness measurement for two-dimensional flakes. The measurement methods, uncertainty evaluation and a comparison of the results and analysis are reported in this manuscript. The data and results of this project will be directly used to support the development of an ISO standard.
- 14 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (12) , 5176-5186
International Interlaboratory Comparison of Thermogravimetric Analysis of Graphene-Related Two-Dimensional Materials
Research on graphene-related two-dimensional (2D) materials (GR2Ms) in recent years is strongly moving from academia to industrial sectors with many new developed products and devices on the market. Characterization and quality control of the GR2Ms and their properties are critical for growing industrial translation, which requires the development of appropriate and reliable analytical methods. These challenges are recognized by International Organization for Standardization (ISO 229) and International Electrotechnical Commission (IEC 113) committees to facilitate the development of these methods and standards which are currently in progress. Toward these efforts, the aim of this study was to perform an international interlaboratory comparison (ILC), conducted under Versailles Project on Advanced Materials and Standards (VAMAS) Technical Working Area (TWA) 41 "Graphene and Related 2D Materials" to evaluate the performance (reproducibility and confidence) of the thermogravimetric analysis (TGA) method as a potential new method for chemical characterization of GR2Ms. Three different types of representative and industrially manufactured GR2Ms samples, namely, pristine few-layer graphene (FLG), graphene oxide (GO), and reduced graphene oxide (rGO), were used and supplied to ILC participants to complete the study. The TGA method performance was evaluated by a series of measurements of selected parameters of the chemical and physical properties of these GR2Ms including the number of mass loss steps, thermal stability, temperature of maximum mass change rate (Tp) for each decomposition step, and the mass contents (%) of moisture, oxygen groups, carbon, and impurities (organic and non-combustible residue). TGA measurements determining these parameters were performed using the provided optimized TGA protocol on the same GR2Ms by 12 participants across academia, industry stakeholders, and national metrology institutes. This paper presents these results with corresponding statistical analysis showing low standard deviation and statistical conformity across all participants that confirm that the TGA method can be satisfactorily used for characterization of these parameters and the chemical characterization and quality control of GR2Ms. The common measurement uncertainty for each parameter, key contribution factors were identified with explanations and recommendations for their elimination and improvements toward their implementation for the development of the ISO/IEC standard for chemical characterization of GR2Ms.
- 14 March 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (12) , 5176-5186
International Interlaboratory Comparison of Thermogravimetric Analysis of Graphene-Related Two-Dimensional Materials
Research on graphene-related two-dimensional (2D) materials (GR2Ms) in recent years is strongly moving from academia to industrial sectors with many new developed products and devices on the market. Characterization and quality control of the GR2Ms and their properties are critical for growing industrial translation, which requires the development of appropriate and reliable analytical methods. These challenges are recognized by International Organization for Standardization (ISO 229) and International Electrotechnical Commission (IEC 113) committees to facilitate the development of these methods and standards which are currently in progress. Toward these efforts, the aim of this study was to perform an international interlaboratory comparison (ILC), conducted under Versailles Project on Advanced Materials and Standards (VAMAS) Technical Working Area (TWA) 41 "Graphene and Related 2D Materials" to evaluate the performance (reproducibility and confidence) of the thermogravimetric analysis (TGA) method as a potential new method for chemical characterization of GR2Ms. Three different types of representative and industrially manufactured GR2Ms samples, namely, pristine few-layer graphene (FLG), graphene oxide (GO), and reduced graphene oxide (rGO), were used and supplied to ILC participants to complete the study. The TGA method performance was evaluated by a series of measurements of selected parameters of the chemical and physical properties of these GR2Ms including the number of mass loss steps, thermal stability, temperature of maximum mass change rate (Tp) for each decomposition step, and the mass contents (%) of moisture, oxygen groups, carbon, and impurities (organic and non-combustible residue). TGA measurements determining these parameters were performed using the provided optimized TGA protocol on the same GR2Ms by 12 participants across academia, industry stakeholders, and national metrology institutes. This paper presents these results with corresponding statistical analysis showing low standard deviation and statistical conformity across all participants that confirm that the TGA method can be satisfactorily used for characterization of these parameters and the chemical characterization and quality control of GR2Ms. The common measurement uncertainty for each parameter, key contribution factors were identified with explanations and recommendations for their elimination and improvements toward their implementation for the development of the ISO/IEC standard for chemical characterization of GR2Ms.
- 6 February 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (5) , 054006
Local geometric error corrections for a metrological scanning probe microscope
A local geometric error correction method is developed for a metrological scanning probe microscope. The method corrects geometric errors in stage displacements using the interferometric measurements of angular position and known geometric offsets. Local and global error correction methods are considered and general scaling dependences on the number of measured steps or points are derived and compared. For the local method, the total uncertainty scales the same or decreases with a sufficient number of measurement steps compared with the global method. Implementation of the local geometric error correction method is demonstrated on measurements of a three-dimensional height standard artefact. The applied error correction method reduces the contribution of geometric errors to the uncertainty budget by two orders of magnitude. The presented approach can be extended to any scanning technique where a measurement translation mechanism can be identified and accurately quantified by relating the measured values with a measurand.
- 6 February 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (5) , 054006
Local geometric error corrections for a metrological scanning probe microscope
A local geometric error correction method is developed for a metrological scanning probe microscope. The method corrects geometric errors in stage displacements using the interferometric measurements of angular position and known geometric offsets. Local and global error correction methods are considered and general scaling dependences on the number of measured steps or points are derived and compared. For the local method, the total uncertainty scales the same or decreases with a sufficient number of measurement steps compared with the global method. Implementation of the local geometric error correction method is demonstrated on measurements of a three-dimensional height standard artefact. The applied error correction method reduces the contribution of geometric errors to the uncertainty budget by two orders of magnitude. The presented approach can be extended to any scanning technique where a measurement translation mechanism can be identified and accurately quantified by relating the measured values with a measurand.
- 25 October 2019
- Published by Elsevier
Contributors
- 1 October 2019
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 554, 388-395
Does gas supersaturation by a chemical reaction produce bulk nanobubbles?
- 1 October 2019
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 554, 388-395
Does gas supersaturation by a chemical reaction produce bulk nanobubbles?
- Open Access
- 12 March 2019
- Published by MDPI AG in Separations
- Vol. 6 (1) , 15
Establishing SI-Traceability of Nanoparticle Size Values Measured with Line-Start Incremental Centrifugal Liquid Sedimentation
Line-start incremental centrifugal liquid sedimentation (disc-CLS) is a powerful technique to determine particle size based on the principles of Stokes’ law. As most input quantities of the Stokes equation cannot be easily determined for typical instruments used for this method, an alternative method which depends on calibrating the sedimentation time scale with reference particles has become common practice. Unfortunately, most of these calibration materials (calibrants) come with limited information regarding their metrological reliability (e.g., lack of measurement uncertainties and traceability statements, incomplete measurand definitions). As a consequence, routine particle size results obtained by disc-CLS are mostly only traceable to the calibrant used, and effective comparisons can only be made for those results originating from measurements performed with the same types of calibrants. In this study, we discuss the concept of metrological traceability and demonstrate that particle size results obtained by disc-CLS can be traceable to the ultimate metrological reference, i.e., the unit of length in the International System of Units (SI), the meter. Using the example of two colloidal silica certified reference materials, we describe how laboratories can realize metrological traceability to the SI by simplifying complex traceability networks.
- 12 March 2019
- Published by MDPI AG in Separations
- Vol. 6 (1) , 15
Open AccessEstablishing SI-Traceability of Nanoparticle Size Values Measured with Line-Start Incremental Centrifugal Liquid Sedimentation
Line-start incremental centrifugal liquid sedimentation (disc-CLS) is a powerful technique to determine particle size based on the principles of Stokes’ law. As most input quantities of the Stokes equation cannot be easily determined for typical instruments used for this method, an alternative method which depends on calibrating the sedimentation time scale with reference particles has become common practice. Unfortunately, most of these calibration materials (calibrants) come with limited information regarding their metrological reliability (e.g., lack of measurement uncertainties and traceability statements, incomplete measurand definitions). As a consequence, routine particle size results obtained by disc-CLS are mostly only traceable to the calibrant used, and effective comparisons can only be made for those results originating from measurements performed with the same types of calibrants. In this study, we discuss the concept of metrological traceability and demonstrate that particle size results obtained by disc-CLS can be traceable to the ultimate metrological reference, i.e., the unit of length in the International System of Units (SI), the meter. Using the example of two colloidal silica certified reference materials, we describe how laboratories can realize metrological traceability to the SI by simplifying complex traceability networks.
- 26 October 2017
- Published by IOP Publishing in Nanotechnology
- Vol. 28 (47) , 475702
Quantification of nanoparticle concentration in colloidal suspensions by a non-destructive optical method
The estimation of nanoparticle number concentration in colloidal suspensions is a prerequisite in many procedures, and in particular in multi-stage, low-yield reactions. Here, we describe a rapid, non-destructive method based on optical extinction and dynamic light scattering (DLS), which combines measurements using common bench-top instrumentation with a numerical algorithm to calculate the particle size distribution (PSD) and concentration. These quantities were derived from Mie theory applied to measurements of the optical extinction spectrum of homogeneous, non-absorbing nanoparticles, and the relative PSD of a colloidal suspension. The work presents an approach to account for PSDs achieved by DLS which, due to the underlying model, may not be representative of the true sample PSD. The presented approach estimates the absolute particle number concentration of samples with mono-, bi-modal and broad size distributions with <50% precision. This provides a convenient and practical solution for number concentration estimation required during many applications of colloidal nanomaterials.
- 26 October 2017
- Published by IOP Publishing in Nanotechnology
- Vol. 28 (47) , 475702
Quantification of nanoparticle concentration in colloidal suspensions by a non-destructive optical method
The estimation of nanoparticle number concentration in colloidal suspensions is a prerequisite in many procedures, and in particular in multi-stage, low-yield reactions. Here, we describe a rapid, non-destructive method based on optical extinction and dynamic light scattering (DLS), which combines measurements using common bench-top instrumentation with a numerical algorithm to calculate the particle size distribution (PSD) and concentration. These quantities were derived from Mie theory applied to measurements of the optical extinction spectrum of homogeneous, non-absorbing nanoparticles, and the relative PSD of a colloidal suspension. The work presents an approach to account for PSDs achieved by DLS which, due to the underlying model, may not be representative of the true sample PSD. The presented approach estimates the absolute particle number concentration of samples with mono-, bi-modal and broad size distributions with <50% precision. This provides a convenient and practical solution for number concentration estimation required during many applications of colloidal nanomaterials.