Aretha Heitor Veríssimo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aretha Heitor Veríssimo has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Adriana da Fonte Porto Carreiro
Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil
8 shared publications - Anne Kaline Claudino Ribeiro
Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil
7 shared publications A.B.N. Januário
6 shared publicationsD.M.D. Moura
Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Brazil
6 shared publicationsG.M. Araújo
Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Brazil
6 shared publicationsI.H.G. Carvalho
Department of Dentistry, Federal University of Rio Grande do Norte, Natal, Brazil
6 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (3) , 139-150
Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts
Claudino Ribeiro AK, et al. J Adv Prosthodont. 2024 Jun;16(3):139-150. https://doi.org/10.4047/jap.2024.16.3.139
- 1 January 2024
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 16 (3) , 139-150
Open AccessAccuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts
Claudino Ribeiro AK, et al. J Adv Prosthodont. 2024 Jun;16(3):139-150. https://doi.org/10.4047/jap.2024.16.3.139
- Open Access
- 25 January 2023
- Published by Centro Universitario Sagrado Coracao - Unisagrado in SALUSVITA
- Vol. 41 (01) , 168
Restabelecimento da dimensão vertical de oclusão com JIG estético modificado e prótese parcial removível overlay: relato de caso
A reabilitação de pacientes parcialmente edêntulos com desgaste dentário severo e dimensão vertical de oclusão reduzida é desafiadora e complexa. Objetivo: Descrever o restabelecimento da dimensão vertical de oclusão e parâmetros estéticos com uma prótese parcial removível do tipo overlay (PPRO) com auxílio de um JIG estético modificado. Relato de caso: Paciente do sexo masculino, 58 anos de idade, procurou serviço odontológico queixando-se de insatisfação com a estética do sorriso e perda dos dentes posteriores. Ao exame clínico, foram observados desgaste dentário excessivo e edentulismo parcial nas arcadas superior e inferior. Então, foi proposto tratamento em 2 etapas (provisória e definitiva) com PPRO em maxila. O JIG estético foi usado como guia de referência para incrementos em resina composta fotopolimerizável e o restabelecimento da dimensão vertical de oclusão foi determinado a partir de métodos métrico, fonético e estético. Os dentes desgastados foram aumentados e os dentes ausentes substituídos por dentes artificiais a partir de uma PPRO provisória. Após 2 meses de adaptação, a reabilitação final com PPRO definitiva foi conduzida baseando-se na reabilitação com a PPRO provisória. Conclusão: O paciente relatou satisfação com a estética e desempenho funcional com o tratamento. Portanto, o JIG estético beneficia o planejamento e tratamento para restabelecer a dimensão vertical de oclusão. Além disso, a PPRO é uma alternativa reversível, de baixo custo para reabilitar a estética e função de pacientes com desgaste severo e perda parcial dos dentes.
- 25 January 2023
- Published by Centro Universitario Sagrado Coracao - Unisagrado in SALUSVITA
- Vol. 41 (01) , 168
Open AccessRestabelecimento da dimensão vertical de oclusão com JIG estético modificado e prótese parcial removível overlay: relato de caso
A reabilitação de pacientes parcialmente edêntulos com desgaste dentário severo e dimensão vertical de oclusão reduzida é desafiadora e complexa. Objetivo: Descrever o restabelecimento da dimensão vertical de oclusão e parâmetros estéticos com uma prótese parcial removível do tipo overlay (PPRO) com auxílio de um JIG estético modificado. Relato de caso: Paciente do sexo masculino, 58 anos de idade, procurou serviço odontológico queixando-se de insatisfação com a estética do sorriso e perda dos dentes posteriores. Ao exame clínico, foram observados desgaste dentário excessivo e edentulismo parcial nas arcadas superior e inferior. Então, foi proposto tratamento em 2 etapas (provisória e definitiva) com PPRO em maxila. O JIG estético foi usado como guia de referência para incrementos em resina composta fotopolimerizável e o restabelecimento da dimensão vertical de oclusão foi determinado a partir de métodos métrico, fonético e estético. Os dentes desgastados foram aumentados e os dentes ausentes substituídos por dentes artificiais a partir de uma PPRO provisória. Após 2 meses de adaptação, a reabilitação final com PPRO definitiva foi conduzida baseando-se na reabilitação com a PPRO provisória. Conclusão: O paciente relatou satisfação com a estética e desempenho funcional com o tratamento. Portanto, o JIG estético beneficia o planejamento e tratamento para restabelecer a dimensão vertical de oclusão. Além disso, a PPRO é uma alternativa reversível, de baixo custo para reabilitar a estética e função de pacientes com desgaste severo e perda parcial dos dentes.
- 3 March 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (6) , 4633-4645
Incidence and risk factors for non-adaptation of new mandibular complete dentures: a clinical trial
Objective To investigate the incidence and risk factors for non-adaptation of the conventional mandibular complete denture (CMCD). Materials and methods A total of 108 edentulous patients were rehabilitated with complete dentures (CDs) and followed up at 3- and 6-month intervals. Adaptation was confirmed based on chewing, phonetics, and comfortable swallowing with the CDs. The risk factors among sociodemographic and patient-centered factors were analyzed. Statistical analyses included the chi-square test and then a multivariate analysis. Results After 3 months, 38.0% of patients showed non-adaptation to CMCDs. Non-adaptation was significantly associated with the absence of previous mandibular denture experience (p = 0.042), ulcerations after 15 days of rehabilitation (p < 0.001), and a reduced posterior mandibular ridge (p = 0.035). After 6 months, this incidence decreased to 14.1%. The factors associated with non-adaptation were ulcerative lesions after 15 (p < 0.001) and 30 (p < 0.001) days of the delivery of CDs and the non-regular use of mandibular CDs (p < 0.001). Conclusion The incidence of non-adaptation was higher after 3 months, with reduction after 6 months. Sociodemographic variables did not influence the adaptation. After 3 months, the absence of previous experience, traumatic ulcers, and reduced mandibular ridges hindered the adaptation of patients to mandibular CDs. After 6 months, only the occurrence of ulcerative lesions and non-regular wear of dentures were risk factors for non-adaptation. Clinical relevance A considerable number of patients have difficulties in adapting to the mandibular dentures. Identifying the factors of non-adaptation of the dentures will contribute to increasing the predictability of this critical adaptation period.
- 3 March 2022
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (6) , 4633-4645
Incidence and risk factors for non-adaptation of new mandibular complete dentures: a clinical trial
Objective To investigate the incidence and risk factors for non-adaptation of the conventional mandibular complete denture (CMCD). Materials and methods A total of 108 edentulous patients were rehabilitated with complete dentures (CDs) and followed up at 3- and 6-month intervals. Adaptation was confirmed based on chewing, phonetics, and comfortable swallowing with the CDs. The risk factors among sociodemographic and patient-centered factors were analyzed. Statistical analyses included the chi-square test and then a multivariate analysis. Results After 3 months, 38.0% of patients showed non-adaptation to CMCDs. Non-adaptation was significantly associated with the absence of previous mandibular denture experience (p = 0.042), ulcerations after 15 days of rehabilitation (p < 0.001), and a reduced posterior mandibular ridge (p = 0.035). After 6 months, this incidence decreased to 14.1%. The factors associated with non-adaptation were ulcerative lesions after 15 (p < 0.001) and 30 (p < 0.001) days of the delivery of CDs and the non-regular use of mandibular CDs (p < 0.001). Conclusion The incidence of non-adaptation was higher after 3 months, with reduction after 6 months. Sociodemographic variables did not influence the adaptation. After 3 months, the absence of previous experience, traumatic ulcers, and reduced mandibular ridges hindered the adaptation of patients to mandibular CDs. After 6 months, only the occurrence of ulcerative lesions and non-regular wear of dentures were risk factors for non-adaptation. Clinical relevance A considerable number of patients have difficulties in adapting to the mandibular dentures. Identifying the factors of non-adaptation of the dentures will contribute to increasing the predictability of this critical adaptation period.
- 7 September 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (2) , 1835-1842
Factors associated with edentulous patients’ willingness about implant-supported complete denture: a multivariate analysis
Objective The aim of this study was to evaluate the factors influencing edentulous patients’ willingness about mandibular implant-supported complete denture. Materials and methods A cross-sectional study was carried out with 117 bimaxillary edentulous patients wearing removable complete dentures (CDs). Patients were assessed concerning denture-related items (number of previous mandibular CDs, previous denture wearing period, dentures maker professional, and regular wearing of previous mandibular dentures) and individual-related aspects, such as mandibular edentulousness period, mandibular bone height, and willingness to the use of mandibular implant-supported complete denture. Masticatory performance was evaluated by the median particle diameter. Mandibular bone height and satisfaction were assessed using a validated method. The Chi-square test was used for data analysis and prevalence ratios were adjusted by using multivariate Poisson regression, both with 95% confidence interval. Results A total of 78 participants (66.7%) were interested in mandibular implant-supported overdenture (mean age 65.33 ± 9.49). Masticatory performance was not influenced by choosing mandibular implant-supported complete denture. The preference about mandibular implant-supported complete denture was correlated with longer mandibular complete denture experience (p = 0.021) and it was significantly associated with dissatisfaction about retention (p = 0.005). Conclusion Previous experience with mandibular complete dentures and dissatisfaction about retention influence the willingness about mandibular implant-supported overdenture. Clinical relevance Many factors are associated with rehabilitation preferences for edentulous patients and mandibular implant-supported complete denture is one of the available alternatives. Therefore, this study has demonstrated the factors influencing the decision to replace a mandibular conventional complete denture by dental implant treatment based on patient’s outcomes. Such finding may be considered as a relevant aspect towards shared decision-making for prosthodontic rehabilitation of edentulous patients.
- 7 September 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (2) , 1835-1842
Factors associated with edentulous patients’ willingness about implant-supported complete denture: a multivariate analysis
Objective The aim of this study was to evaluate the factors influencing edentulous patients’ willingness about mandibular implant-supported complete denture. Materials and methods A cross-sectional study was carried out with 117 bimaxillary edentulous patients wearing removable complete dentures (CDs). Patients were assessed concerning denture-related items (number of previous mandibular CDs, previous denture wearing period, dentures maker professional, and regular wearing of previous mandibular dentures) and individual-related aspects, such as mandibular edentulousness period, mandibular bone height, and willingness to the use of mandibular implant-supported complete denture. Masticatory performance was evaluated by the median particle diameter. Mandibular bone height and satisfaction were assessed using a validated method. The Chi-square test was used for data analysis and prevalence ratios were adjusted by using multivariate Poisson regression, both with 95% confidence interval. Results A total of 78 participants (66.7%) were interested in mandibular implant-supported overdenture (mean age 65.33 ± 9.49). Masticatory performance was not influenced by choosing mandibular implant-supported complete denture. The preference about mandibular implant-supported complete denture was correlated with longer mandibular complete denture experience (p = 0.021) and it was significantly associated with dissatisfaction about retention (p = 0.005). Conclusion Previous experience with mandibular complete dentures and dissatisfaction about retention influence the willingness about mandibular implant-supported overdenture. Clinical relevance Many factors are associated with rehabilitation preferences for edentulous patients and mandibular implant-supported complete denture is one of the available alternatives. Therefore, this study has demonstrated the factors influencing the decision to replace a mandibular conventional complete denture by dental implant treatment based on patient’s outcomes. Such finding may be considered as a relevant aspect towards shared decision-making for prosthodontic rehabilitation of edentulous patients.
- 27 August 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (1) , 889-900
Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study
Objective To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). Materials and methods A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: “in situ aging” (non-aged and aged (A)) and “finishing/polishing” (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey’s test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal–Wallis tests. Results For flexural resistance, the “finishing/polishing” factor was statistically significant (P = 0.0001); however, the “in situ aging” factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. Conclusions The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. Clinical relevance Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.
- 27 August 2021
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 26 (1) , 889-900
Effect of finishing/polishing techniques and aging on topography, C. albicans adherence, and flexural strength of ultra-translucent zirconia: an in situ study
Objective To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). Materials and methods A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: “in situ aging” (non-aged and aged (A)) and “finishing/polishing” (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (μm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey’s test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal–Wallis tests. Results For flexural resistance, the “finishing/polishing” factor was statistically significant (P = 0.0001); however, the “in situ aging” factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. Conclusions The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. Clinical relevance Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.
- Open Access
- 18 August 2021
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 32 (9) , 1-13
Comparative analysis of the hemostatic, analgesic and healing effects of cyanoacrylate on free gingival graft surgical wounds in donor and recipient areas: a systematic review
To analyze the hemostatic, Dsurgical wounds in donor and recipient areas of free gingival grafts (FGG). Five databases (PubMed, Scopus, Science Direct, Cochrane and Web of Science) were searched up to March 2021 (PROSPERO CRD42019134497). The focus of the study (cyanoacrylate) was combined with the condition (periodontal surgery OR free gingival graft OR free soft tissue graft OR autografts), and outcome (healing OR epithelialization OR pain OR analgesia OR bleeding OR hemostasis OR hemostatic). Studies reporting cyanoacrylate isolated or associated with another substance in FGG stabilization and closure were investigated and assessed for the quality and risk of bias through the Cochrane Manual. Six studies with 323 participants were included. Evaluation of the quality and risk of bias highlighted a low risk for four articles, intermediate for one and unclear for another. The use of cyanoacrylate associated or not with the hemostatic sponge or the platelet-rich fibrin was more effective in healing (three studies), analgesia (four studies), and hemostasis in one study (p < 0.05). However, groups with the association in cyanoacrylate showed superior healing, and analgesic action to the isolated cyanoacrylate group. In addition, two studies demonstrated that cyanoacrylate use reduces surgery duration, one study showed that it reduces postoperative sensibility, and another present hemostatic effect (p < 0.05). There is scarce literature for the use of cyanoacrylate in FGG wounds indicates that it can promote a minor inflammatory response, reduce operation time, does not interfere with healing, relieves postoperative discomfort, and suggests the possibility immediate hemostasis. Its use presents an alternative to suturing in FGG surgeries. But, the limited number of cases and the relative heterogeneity of the included studies suggest caution in generalizing the indication. Clinical relevance: Cyanoacrylate seems to present analgesic effects and less pain when applied to wound closure and covering donor and recipient areas reducing the need for postoperative analgesic medication; and has a healing effect in the closure of the donor area on the palate. In addition, it can reduce bleeding time after surgery, and prevents late bleeding during the first postsurgical week. Scientific justification: To evaluate the hemostatic, analgesic and healing actions of cyanoacrylate compared to the suture thread and other agents when used to close surgical wounds from periodontal free gingival graft surgical wounds in both the donor and recipient areas of the graft. Main findings: The use of cyanoacrylate individually or in association with wound dressing agents presents analgesic effects because the patient reports less pain experienced when cyanoacrylate is applied to the wound closure and covering, thereby reducing the need for postoperative analgesic medication. In addition, a healing effect is observed in the closure of the donor area on the palate; as well as it seems to present hemostatic effects, reducing the bleeding time after surgery, and preventing late bleeding during the first postsurgical week. Practical implications: Dentists may cautiously apply cyanoacrylate after periodontal surgeries for free gingival graft in both the donor and recipient areas of the graft. However, they must consider the limitations of the surgery, tension-free positioning, the patient’s dyscrasia and postoperative care, constituting a set of predictors for adequate clinical decision-making. Widespread use of such material for all patients and surgical configurations may not be recommended.
- 18 August 2021
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 32 (9) , 1-13
Open AccessComparative analysis of the hemostatic, analgesic and healing effects of cyanoacrylate on free gingival graft surgical wounds in donor and recipient areas: a systematic review
To analyze the hemostatic, Dsurgical wounds in donor and recipient areas of free gingival grafts (FGG). Five databases (PubMed, Scopus, Science Direct, Cochrane and Web of Science) were searched up to March 2021 (PROSPERO CRD42019134497). The focus of the study (cyanoacrylate) was combined with the condition (periodontal surgery OR free gingival graft OR free soft tissue graft OR autografts), and outcome (healing OR epithelialization OR pain OR analgesia OR bleeding OR hemostasis OR hemostatic). Studies reporting cyanoacrylate isolated or associated with another substance in FGG stabilization and closure were investigated and assessed for the quality and risk of bias through the Cochrane Manual. Six studies with 323 participants were included. Evaluation of the quality and risk of bias highlighted a low risk for four articles, intermediate for one and unclear for another. The use of cyanoacrylate associated or not with the hemostatic sponge or the platelet-rich fibrin was more effective in healing (three studies), analgesia (four studies), and hemostasis in one study (p < 0.05). However, groups with the association in cyanoacrylate showed superior healing, and analgesic action to the isolated cyanoacrylate group. In addition, two studies demonstrated that cyanoacrylate use reduces surgery duration, one study showed that it reduces postoperative sensibility, and another present hemostatic effect (p < 0.05). There is scarce literature for the use of cyanoacrylate in FGG wounds indicates that it can promote a minor inflammatory response, reduce operation time, does not interfere with healing, relieves postoperative discomfort, and suggests the possibility immediate hemostasis. Its use presents an alternative to suturing in FGG surgeries. But, the limited number of cases and the relative heterogeneity of the included studies suggest caution in generalizing the indication. Clinical relevance: Cyanoacrylate seems to present analgesic effects and less pain when applied to wound closure and covering donor and recipient areas reducing the need for postoperative analgesic medication; and has a healing effect in the closure of the donor area on the palate. In addition, it can reduce bleeding time after surgery, and prevents late bleeding during the first postsurgical week. Scientific justification: To evaluate the hemostatic, analgesic and healing actions of cyanoacrylate compared to the suture thread and other agents when used to close surgical wounds from periodontal free gingival graft surgical wounds in both the donor and recipient areas of the graft. Main findings: The use of cyanoacrylate individually or in association with wound dressing agents presents analgesic effects because the patient reports less pain experienced when cyanoacrylate is applied to the wound closure and covering, thereby reducing the need for postoperative analgesic medication. In addition, a healing effect is observed in the closure of the donor area on the palate; as well as it seems to present hemostatic effects, reducing the bleeding time after surgery, and preventing late bleeding during the first postsurgical week. Practical implications: Dentists may cautiously apply cyanoacrylate after periodontal surgeries for free gingival graft in both the donor and recipient areas of the graft. However, they must consider the limitations of the surgery, tension-free positioning, the patient’s dyscrasia and postoperative care, constituting a set of predictors for adequate clinical decision-making. Widespread use of such material for all patients and surgical configurations may not be recommended.
- Open Access
- 1 January 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (1)
Reabilitação oral com implante e carga imediata unitária por cirurgia guiada: relato de caso
O edentulismo é um desafio extremamente frequente no dia-a-dia do cirurgião dentista. A busca de soluções funcionais e estéticas para estes casos têm proporcionado diversas inovações no mercado de materiais odontológicos como, por exemplo, os implantes dentais osseointegráveis, próteses, coroas e guias cirúrgicas. O aprimoramento de materiais e métodos em Implantodontia trouxeram possibilidades de intervenção, que por meio do planejamento digital e confecção de guias cirúrgicas 3D, concedem menor tempo de trabalho para assim, ofertar ao paciente maior conforto através de técnicas menos invasivas e cruentas, com a finalidade de reestabelecer a função, estética e condição biopsicossocial do paciente. Este caso clínico visa descrever o planejamento e instalação de implante dentário cone morse imediato (Drive, Neodent®, Curitiba, Brasil) utilizando a técnica com guia cirúrgica 3D (3D Studio – Planejamento Virtual da Face®, Natal- RN, Brasil), planejada através de tomografia computadorizada cone beam analisada através do software Blue Sky Bio LLC (Libertyville, Illinois), além da realização de enxertia com estrutura óssea mineral bovina (Lumina-Bone Fino, Criteria®, SP- São Paulo, Brasil) seguido da confecção de coroa unitária e instalação de carga imediata em área estética.
- 1 January 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (1)
Open AccessReabilitação oral com implante e carga imediata unitária por cirurgia guiada: relato de caso
O edentulismo é um desafio extremamente frequente no dia-a-dia do cirurgião dentista. A busca de soluções funcionais e estéticas para estes casos têm proporcionado diversas inovações no mercado de materiais odontológicos como, por exemplo, os implantes dentais osseointegráveis, próteses, coroas e guias cirúrgicas. O aprimoramento de materiais e métodos em Implantodontia trouxeram possibilidades de intervenção, que por meio do planejamento digital e confecção de guias cirúrgicas 3D, concedem menor tempo de trabalho para assim, ofertar ao paciente maior conforto através de técnicas menos invasivas e cruentas, com a finalidade de reestabelecer a função, estética e condição biopsicossocial do paciente. Este caso clínico visa descrever o planejamento e instalação de implante dentário cone morse imediato (Drive, Neodent®, Curitiba, Brasil) utilizando a técnica com guia cirúrgica 3D (3D Studio – Planejamento Virtual da Face®, Natal- RN, Brasil), planejada através de tomografia computadorizada cone beam analisada através do software Blue Sky Bio LLC (Libertyville, Illinois), além da realização de enxertia com estrutura óssea mineral bovina (Lumina-Bone Fino, Criteria®, SP- São Paulo, Brasil) seguido da confecção de coroa unitária e instalação de carga imediata em área estética.
- Open Access
- 17 September 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (10)
Alternative impression technique for edentulous anterior maxillary flabby tissue
This present study describes an impression technique to rehabilitate patients with flabby ridge in pre-maxilla through complete dentures. The proposed technique consists on the association of nondisplacive impression of the flabby area in the primary and functional impression. Therefore, a primary impression was performed with irreversible hydrocolloid with a dual impression. The impression material was removed at the region corresponding to the flabby area, characterizing a window, where a re-impression was conducted with the same material in a more fluid consistency. The functional impression was executed with a custom tray with perforations at the flabby area fabricated over a primary anatomic cast previously relieved. As a result, an anatomic impression with reduced compression over the flabby ridge was obtained. Moreover, an accentuated decrease of the mucosa compression was obtained through the material overflow from the custom tray perforations at the functional impression. After the acrylization of the prosthetic piece, a delimited box corresponding to the flabby mucosa in the prosthesis base was verified. Thus, it is concluded that the association of techniques proposed in this study reduced the compression over the flabby ridge area resulting in a complete denture copying anatomically the flabby area at rest. Thereby, in this case through a precise negative reproduction, a more favorable retention of the maxillary complete denture was obtained in patients with flabby ridge at the pre-maxillary area.
- 17 September 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (10)
Open AccessAlternative impression technique for edentulous anterior maxillary flabby tissue
This present study describes an impression technique to rehabilitate patients with flabby ridge in pre-maxilla through complete dentures. The proposed technique consists on the association of nondisplacive impression of the flabby area in the primary and functional impression. Therefore, a primary impression was performed with irreversible hydrocolloid with a dual impression. The impression material was removed at the region corresponding to the flabby area, characterizing a window, where a re-impression was conducted with the same material in a more fluid consistency. The functional impression was executed with a custom tray with perforations at the flabby area fabricated over a primary anatomic cast previously relieved. As a result, an anatomic impression with reduced compression over the flabby ridge was obtained. Moreover, an accentuated decrease of the mucosa compression was obtained through the material overflow from the custom tray perforations at the functional impression. After the acrylization of the prosthetic piece, a delimited box corresponding to the flabby mucosa in the prosthesis base was verified. Thus, it is concluded that the association of techniques proposed in this study reduced the compression over the flabby ridge area resulting in a complete denture copying anatomically the flabby area at rest. Thereby, in this case through a precise negative reproduction, a more favorable retention of the maxillary complete denture was obtained in patients with flabby ridge at the pre-maxillary area.
- Open Access
- 17 September 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (10)
A simplified technique to fabricate complete dentures from the previous prosthesis duplication for elderly patients
Introduction: The time required for the complete dentures confection may be a limiting factor in the treatment of geriatric patients since these patients have age-related systemic conditions and morbidities that limit their mobility. Also, the elderly ability to adapt to a new prosthesis with very different characteristics from the existing ones can be difficult. Methodology: This present study aims to describe a simplified technique to fabricate the complete dentures in two visits by duplicating the patient existent prosthesis, with the teeth area confectioned in wax and the other parts made of acrylic resin. The technique consists of using the replica of the patient's existent prosthesis to record the maxillomandibular relations and as a vehicle for obtaining the functional cast. Results: This technique showed the improvement of the esthetic factors, an increase of the occlusal vertical dimension, and lip support when compared to the patient’s previous prosthesis. Conclusion: This technique allows the reduction of clinical steps and provides the patients with an easier adaptation of the new prosthesis.
- 17 September 2020
- Published by Research, Society and Development in Research, Society and Development
- Vol. 9 (10)
Open AccessA simplified technique to fabricate complete dentures from the previous prosthesis duplication for elderly patients
Introduction: The time required for the complete dentures confection may be a limiting factor in the treatment of geriatric patients since these patients have age-related systemic conditions and morbidities that limit their mobility. Also, the elderly ability to adapt to a new prosthesis with very different characteristics from the existing ones can be difficult. Methodology: This present study aims to describe a simplified technique to fabricate the complete dentures in two visits by duplicating the patient existent prosthesis, with the teeth area confectioned in wax and the other parts made of acrylic resin. The technique consists of using the replica of the patient's existent prosthesis to record the maxillomandibular relations and as a vehicle for obtaining the functional cast. Results: This technique showed the improvement of the esthetic factors, an increase of the occlusal vertical dimension, and lip support when compared to the patient’s previous prosthesis. Conclusion: This technique allows the reduction of clinical steps and provides the patients with an easier adaptation of the new prosthesis.