Takuya Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Takuya Yamamoto has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Sergey V. Komarov
Tohoku Univ, Grad Sch Engn, Dept Met, Miyagi 9808579, Japan
21 shared publications- Kanji D. Hattori
Department of Chemical Engineering, Graduate School of Engineering, Osaka Metropolitan University, 1-1, Gakuen-cho, Naka-ku, Sakai, Osaka 599-8531, Japan
5 shared publications Yasuo Ishiwata
Nippon Light Metal Co, Ltd., Shizuoka, Japan
5 shared publicationsSergey Komarov
4 shared publications- Yu Fang
Graduate School of Environmental Studies, Tohoku University, 6-6-02 Aza Aoba, Aramaki, Aoba-Ku, Sendai 980-8579, Japan
4 shared publications Keisuke Kamiya
Casting Technology Research Section, Research and Development Division, UACJ Corporation, Nagoya, Japan
3 shared publications
Latest Publications
- Open Access
- 6 August 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 132, 107995
Influence of harmonic waves on rectified diffusion around acoustic cavitation bubble under kHz ultrasound
- 6 August 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 132, 107995
Open AccessInfluence of harmonic waves on rectified diffusion around acoustic cavitation bubble under kHz ultrasound
- Open Access
- 15 June 2026
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 66 (7) , 821-829
Continuum Species Transfer Model for Reactive Mass Transfer from a Dissolving Bubble Floating at High Péclet Number
In the present study, the numerical accuracy of a continuum species transfer (CST) model coupled with the volume-of-fluid (VOF) method for high Schmidt number fluids with or without chemical reactions was evaluated for the purpose of creating a numerical model of multiphase flow for use in a steel-making process. Even under the condition without a chemical reaction, the original CST model is incapable of accurately calculating mass transfer under conditions characterized by a high Péclet (Pe) number. However, the compressive CST (C-CST) model has been demonstrated to possess the capacity to accurately calculate mass transfer under conditions characterized by a high Pe number. The C-CST model, when coupled with a chemical reaction, was also validated for chemical absorption. The C-CST model with a chemical reaction can calculate the entire mass transfer involving a chemical reaction, particularly in conditions characterized by high Schmidt and Péclet numbers. However, numerical inaccuracies have been observed in the local mass transfer and chemical reaction due to calculation errors in the interfacial curvature necessary for the VOF method.
- 15 June 2026
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 66 (7) , 821-829
Open AccessContinuum Species Transfer Model for Reactive Mass Transfer from a Dissolving Bubble Floating at High Péclet Number
In the present study, the numerical accuracy of a continuum species transfer (CST) model coupled with the volume-of-fluid (VOF) method for high Schmidt number fluids with or without chemical reactions was evaluated for the purpose of creating a numerical model of multiphase flow for use in a steel-making process. Even under the condition without a chemical reaction, the original CST model is incapable of accurately calculating mass transfer under conditions characterized by a high Péclet (Pe) number. However, the compressive CST (C-CST) model has been demonstrated to possess the capacity to accurately calculate mass transfer under conditions characterized by a high Pe number. The C-CST model, when coupled with a chemical reaction, was also validated for chemical absorption. The C-CST model with a chemical reaction can calculate the entire mass transfer involving a chemical reaction, particularly in conditions characterized by high Schmidt and Péclet numbers. However, numerical inaccuracies have been observed in the local mass transfer and chemical reaction due to calculation errors in the interfacial curvature necessary for the VOF method.
- Open Access
- 7 June 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 131, 107918
Multiscale numerical simulation based on Caflisch model to interpret power-induced quenching for sonochemical reactions
- 7 June 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 131, 107918
Open AccessMultiscale numerical simulation based on Caflisch model to interpret power-induced quenching for sonochemical reactions
- Open Access
- 22 May 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 130, 107898
Interaction between number of formed bubbles, reaction rate and flow velocity of acoustic streaming in the initiation period of power-induced quenching
- 22 May 2026
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 130, 107898
Open AccessInteraction between number of formed bubbles, reaction rate and flow velocity of acoustic streaming in the initiation period of power-induced quenching
- Open Access
- 1 April 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (4)
Dominant mode shift of bubble shape instability due to surface tension variation under MHz ultrasound
Occurrence condition for non-spherical shape mode of acoustically oscillated lipidic-coated bubble was numerically investigated by solving both the Keller–Miksis equation and dynamic equation for distortion amplitude of spherical harmonics. To simply model the lipidic-coated bubble, apparent surface tension is introduced into the numerical model. The numerical simulation indicated that the growth rate of distortion amplitude in an ultrasonic cycle is an important factor to predict the shape mode of a non-spherically oscillating bubble under MHz ultrasound. According to the occurrence condition of non-spherical oscillation modes derived from the growth of distortion amplitude, larger degree of spherical harmonics is dominant with increasing the equilibrium bubble radius, and the degree is not significantly impacted by pressure amplitude. When the apparent surface tension is reduced to model lipidic-coated bubbles, shape instability occurs in smaller bubbles, yielding numerical results that are consistent with experimental observations conducted previously by other researchers.
- 1 April 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (4)
Open AccessDominant mode shift of bubble shape instability due to surface tension variation under MHz ultrasound
Occurrence condition for non-spherical shape mode of acoustically oscillated lipidic-coated bubble was numerically investigated by solving both the Keller–Miksis equation and dynamic equation for distortion amplitude of spherical harmonics. To simply model the lipidic-coated bubble, apparent surface tension is introduced into the numerical model. The numerical simulation indicated that the growth rate of distortion amplitude in an ultrasonic cycle is an important factor to predict the shape mode of a non-spherically oscillating bubble under MHz ultrasound. According to the occurrence condition of non-spherical oscillation modes derived from the growth of distortion amplitude, larger degree of spherical harmonics is dominant with increasing the equilibrium bubble radius, and the degree is not significantly impacted by pressure amplitude. When the apparent surface tension is reduced to model lipidic-coated bubbles, shape instability occurs in smaller bubbles, yielding numerical results that are consistent with experimental observations conducted previously by other researchers.
- Open Access
- 24 June 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 120, 107444
Stability analysis of the effect of harmonic waves on the shape stability of acoustic cavitation bubbles
- 24 June 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 120, 107444
Open AccessStability analysis of the effect of harmonic waves on the shape stability of acoustic cavitation bubbles
- Open Access
- 6 June 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 120, 107419
Revisit to the mechanism of quenching: Power effects for sonochemical reactions
- 6 June 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 120, 107419
Open AccessRevisit to the mechanism of quenching: Power effects for sonochemical reactions
- Open Access
- 17 April 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 117, 107361
Does macroscopic mass transfer affect sonochemical reaction rate in an ultrasonic bath?
- 17 April 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 117, 107361
Open AccessDoes macroscopic mass transfer affect sonochemical reaction rate in an ultrasonic bath?
- Open Access
- 28 February 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 115, 107295
Mass transfer of acoustic cavitation bubbles in multi-bubble environment
- 28 February 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 115, 107295
Open AccessMass transfer of acoustic cavitation bubbles in multi-bubble environment
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Linear stability analysis for bubble shape of acoustic cavitation with different ultrasonic frequencies
In the present study, the bubble shape stability of acoustic cavitation is numerically investigated with different ultrasonic frequencies by solving the Keller equation and dynamic equation of distortion amplitude simultaneously to investigate the effect of ultrasonic frequency on the stability. The bubble shape is distorted at higher pressure amplitude and larger bubble size, and the lower degree of spherical harmonics contributes to the instabilities. The stable zone in a stability diagram of parametric instability is similar to that of afterbounce instability at small ultrasonic frequency (∼20 kHz), although the parametric instability becomes the main factor to cause bubble shape instability at higher ultrasonic frequency (f > 40 kHz) because the afterbounce instability becomes difficult to occur due to the short time period from Rayleigh collapse to the start moment of the next ultrasonic cycle. Moreover, the slope of the main stable and unstable boundaries in a phase diagram between pressure amplitude and bubble radius becomes smaller with ultrasonic frequency suggesting that the width of bubble equilibrium size distribution becomes narrower at higher ultrasonic frequency.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Linear stability analysis for bubble shape of acoustic cavitation with different ultrasonic frequencies
In the present study, the bubble shape stability of acoustic cavitation is numerically investigated with different ultrasonic frequencies by solving the Keller equation and dynamic equation of distortion amplitude simultaneously to investigate the effect of ultrasonic frequency on the stability. The bubble shape is distorted at higher pressure amplitude and larger bubble size, and the lower degree of spherical harmonics contributes to the instabilities. The stable zone in a stability diagram of parametric instability is similar to that of afterbounce instability at small ultrasonic frequency (∼20 kHz), although the parametric instability becomes the main factor to cause bubble shape instability at higher ultrasonic frequency (f > 40 kHz) because the afterbounce instability becomes difficult to occur due to the short time period from Rayleigh collapse to the start moment of the next ultrasonic cycle. Moreover, the slope of the main stable and unstable boundaries in a phase diagram between pressure amplitude and bubble radius becomes smaller with ultrasonic frequency suggesting that the width of bubble equilibrium size distribution becomes narrower at higher ultrasonic frequency.