Jayasree Pillarisetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jayasree Pillarisetti has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Dhanunjaya Lakkireddy
University of Kansas Hospital & Medical Center
16 shared publications Madhu Reddy
UT Health San Antonio, KCHRI, University of Kansas Hospital, Kansas City, KS, USA
13 shared publicationsSudharani Bommana
UT Health San Antonio, KCHRI, University of Kansas Hospital, Kansas City, KS, USA
13 shared publicationsDonita Atkins
UT Health San Antonio, KCHRI, University of Kansas Hospital, Kansas City, KS, USA
12 shared publications- Arun Kanmanthareddy
The University of Kansas Medical Center, Kansas City, KS
9 shared publications Arun Raghav Mahankali Sridhar
5 shared publications
Latest Publications
- Open Access
- 1 November 2020
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 20 (6) , 261-264
Comparison of peri-procedural anticoagulation with rivaroxaban and apixaban during radiofrequency ablation of atrial fibrillation
- 1 November 2020
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 20 (6) , 261-264
Open AccessComparison of peri-procedural anticoagulation with rivaroxaban and apixaban during radiofrequency ablation of atrial fibrillation
- 15 November 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 58 (2) , 141-146
Peri-procedural use of direct anticoagulation agents during cardiac device implantation: vitamin K antagonists vs direct oral anticoagulants
Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied.
- 15 November 2019
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 58 (2) , 141-146
Peri-procedural use of direct anticoagulation agents during cardiac device implantation: vitamin K antagonists vs direct oral anticoagulants
Warfarin is deemed safe compared to bridging with heparin in the peri-procedure setting while implanting cardiac devices. The timing of discontinuation and re-initiation of direct anticoagulant agents (DOACs) such as dabigatran, apixaban, and rivaroxaban in the peri-procedural setting in comparison to warfarin is not well studied.
- 1 February 2017
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 48 (3) , 283-289
Risk of ventricular tachyarrhythmias following improvement of left ventricular ejection fraction in patients with implantable cardiac defibrillators implanted for primary prevention of sudden cardiac death
In patients who undergo implantable cardiac defibrillator (ICD) implantation for primary prevention of sudden cardiac death (SCD), data is unclear whether their ICD generator needs to be replaced at end of life if their left ventricular ejection fraction (EF) improves. Despite improvement in EF, the underlying scar may represent a potential substrate for ventricular arrhythmias. Data on 280 patients who underwent ICD implantation for primary prevention of SCD was obtained from two centers. Patients were followed for any improvement in EF to ≥35%. All arrhythmic events during follow-up, including appropriate and inappropriate shocks/ATP, were recorded. Thirty percent (n = 86/280) of patients improved their EF to >35% of which 41% (n = 37) underwent a generator change by the study ending period with the rest not yet at ERI. Mean baseline EF in patients with and without target EF improvement was 26 ± 7 and 23 ± 7% (p = 0.2). After excluding patients whose arrhythmic events data were unavailable, the final sample consisted of 62 patients in the EF improvement group and 156 patients in the group without EF improvement. In the group with EF improvement, appropriate events (shock + ATP) were noted in 19% of patients (n = 12/62) and inappropriate shocks and ATP in 6% of (n = 4/62) patients after their EF improved to >35%. Four patients received appropriate therapies when their EF was low prior to improvement. In contrast, in patients who had no improvement in EF, 27% (n = 43/156) received an appropriate therapy (p = 0.6) while 11% (n = 18/156) (p = 0.2) received inappropriate shocks and ATP. All-cause mortality was higher in patients without subsequent improvement in EF versus those with EF improvement (31 vs. 15% (p = .005). There was no significant difference in the number of appropriate therapies received by each group. Patients continue to be at high risk for sudden cardiac death despite improvement in EF.
- 1 February 2017
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 48 (3) , 283-289
Risk of ventricular tachyarrhythmias following improvement of left ventricular ejection fraction in patients with implantable cardiac defibrillators implanted for primary prevention of sudden cardiac death
In patients who undergo implantable cardiac defibrillator (ICD) implantation for primary prevention of sudden cardiac death (SCD), data is unclear whether their ICD generator needs to be replaced at end of life if their left ventricular ejection fraction (EF) improves. Despite improvement in EF, the underlying scar may represent a potential substrate for ventricular arrhythmias. Data on 280 patients who underwent ICD implantation for primary prevention of SCD was obtained from two centers. Patients were followed for any improvement in EF to ≥35%. All arrhythmic events during follow-up, including appropriate and inappropriate shocks/ATP, were recorded. Thirty percent (n = 86/280) of patients improved their EF to >35% of which 41% (n = 37) underwent a generator change by the study ending period with the rest not yet at ERI. Mean baseline EF in patients with and without target EF improvement was 26 ± 7 and 23 ± 7% (p = 0.2). After excluding patients whose arrhythmic events data were unavailable, the final sample consisted of 62 patients in the EF improvement group and 156 patients in the group without EF improvement. In the group with EF improvement, appropriate events (shock + ATP) were noted in 19% of patients (n = 12/62) and inappropriate shocks and ATP in 6% of (n = 4/62) patients after their EF improved to >35%. Four patients received appropriate therapies when their EF was low prior to improvement. In contrast, in patients who had no improvement in EF, 27% (n = 43/156) received an appropriate therapy (p = 0.6) while 11% (n = 18/156) (p = 0.2) received inappropriate shocks and ATP. All-cause mortality was higher in patients without subsequent improvement in EF versus those with EF improvement (31 vs. 15% (p = .005). There was no significant difference in the number of appropriate therapies received by each group. Patients continue to be at high risk for sudden cardiac death despite improvement in EF.
- 1 May 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 187, 12-16
Impact of gender on outcomes after atrial fibrillation ablation
- 1 May 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 187, 12-16
Impact of gender on outcomes after atrial fibrillation ablation