Faisal Nouman Baig
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Faisal Nouman Baig has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Helen Ka Wai Law
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China
2 shared publications - Michael Ying
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
2 shared publications - Shea Ping Yip
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong
2 shared publications Chung Pui B Koo
1 shared publicationFrank F. Zhu
Affiliation HealthyMind Neuro-Wellness Centre, Central, Hong Kong
1 shared publicationHkw Law
1 shared publication
Latest Publications
- Open Access
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 234-235
Update on the therapeutic efficacy of noninvasive brain stimulation for the recovery of dysarthria: A systemic review
- 15 February 2023
- Published by Elsevier in Brain Stimulation
- Vol. 16 (1) , 234-235
Open AccessUpdate on the therapeutic efficacy of noninvasive brain stimulation for the recovery of dysarthria: A systemic review
- Open Access
- 13 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275779
Transcranial direct current stimulation over the primary motor cortex improves speech production in post-stroke dysarthric speakers: A randomized pilot study
Purpose: The current study investigated the therapeutic potential of transcranial direct current stimulation (tDCS) on speech intelligibility, speech-related physiological and vocal functions among post-stroke dysarthric patients. Method: Nine chronic post-stroke dysarthric patients were randomly assigned to the stimulation or sham group. The stimulation group received 2mA of anodal tDCS over the left inferior primary motor cortex for 15 minutes, while the sham group received 30s of stimulation under the same settings. All the participants received 10 daily 15 minutes of individualized speech therapy targeting their dominant phonological process or phonemes with the greatest difficulty. The outcome measures included (1) perceptual analysis of single words, passage reading and diadochokinetic rate, (2) acoustic analysis of a sustained vowel, and (3) kinematic analysis of rapid syllable repetitions and syllable production in sentence, conducted before and after the treatment. Results: The results revealed that both the stimulation and sham groups had improved perceptual speech intelligibility at the word level, reduced short rushes of speech during passage reading, improved rate during alternating motion rate, AMR-kha1, and improved articulatory kinematics in AMR-tha1 and syllables /tha1/ and /kha1/ production in sentence. Compared to the sham group, the stimulation group showed significant improvement in articulatory kinematics in AMR-kha1 and syllable /kha1/ production in sentence. The findings also showed that anodal stimulation led to reduced shimmer value in sustained vowel /a/ phonation, positive changes in articulatory kinematics in AMR-tha1 and syllables /pha1/ and /kha1/ production in sentence at the post treatment measure. In addition to positive effects on articulatory control, reduced perturbation of voice amplitude documented in the stimulation group post treatment suggests possible tDCS effects on the vocal function. Conclusions: The current study documented the beneficial effects of anodal tDCS over the primary motor cortex on speech production and suggested that combined tDCS and speech therapy may promote recovery from post-stroke dysarthria.
- 13 October 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (10) , e0275779
Open AccessTranscranial direct current stimulation over the primary motor cortex improves speech production in post-stroke dysarthric speakers: A randomized pilot study
Purpose: The current study investigated the therapeutic potential of transcranial direct current stimulation (tDCS) on speech intelligibility, speech-related physiological and vocal functions among post-stroke dysarthric patients. Method: Nine chronic post-stroke dysarthric patients were randomly assigned to the stimulation or sham group. The stimulation group received 2mA of anodal tDCS over the left inferior primary motor cortex for 15 minutes, while the sham group received 30s of stimulation under the same settings. All the participants received 10 daily 15 minutes of individualized speech therapy targeting their dominant phonological process or phonemes with the greatest difficulty. The outcome measures included (1) perceptual analysis of single words, passage reading and diadochokinetic rate, (2) acoustic analysis of a sustained vowel, and (3) kinematic analysis of rapid syllable repetitions and syllable production in sentence, conducted before and after the treatment. Results: The results revealed that both the stimulation and sham groups had improved perceptual speech intelligibility at the word level, reduced short rushes of speech during passage reading, improved rate during alternating motion rate, AMR-kha1, and improved articulatory kinematics in AMR-tha1 and syllables /tha1/ and /kha1/ production in sentence. Compared to the sham group, the stimulation group showed significant improvement in articulatory kinematics in AMR-kha1 and syllable /kha1/ production in sentence. The findings also showed that anodal stimulation led to reduced shimmer value in sustained vowel /a/ phonation, positive changes in articulatory kinematics in AMR-tha1 and syllables /pha1/ and /kha1/ production in sentence at the post treatment measure. In addition to positive effects on articulatory control, reduced perturbation of voice amplitude documented in the stimulation group post treatment suggests possible tDCS effects on the vocal function. Conclusions: The current study documented the beneficial effects of anodal tDCS over the primary motor cortex on speech production and suggested that combined tDCS and speech therapy may promote recovery from post-stroke dysarthria.
- Open Access
- 28 June 2018
- Published by Hong Kong Academy of Medicine Press in Hong Kong Journal of Radiology
- Vol. 21 (2) , 82-83
Update on Ultrasound Diagnosis for Thyroid Cancer
Hong Kong Journal of Radiology
- 28 June 2018
- Published by Hong Kong Academy of Medicine Press in Hong Kong Journal of Radiology
- Vol. 21 (2) , 82-83
Open AccessUpdate on Ultrasound Diagnosis for Thyroid Cancer
Hong Kong Journal of Radiology
- Open Access
- 30 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 14350
Computer-aided assessment of regional vascularity of thyroid nodules for prediction of malignancy
Color Doppler vascular index (VI) was assessed alone and in combination with grey-scale ultrasound (GSU) in regionally subdivided thyroid nodules in diagnosing thyroid cancer. Color Doppler sonograms of 111 thyroid nodules were evaluated by a home-developed algorithm that performed “offsetting” (algorithm for changing the area of a region of interest, ROI, without distorting the ROI’s contour) and assessed peripheral, central and overall VI of thyroid nodules. Results showed that the optimum offset for dividing peripheral and central regions of nodule was 22%. At the optimum offset, the mean VI of peripheral, central, and overall regions of malignant nodules were significantly higher than those of benign nodules (26.5 ± 16.2%, 21.7 ± 19.6%, 23.8 ± 4.6% v/s 18.2 ± 16.7%, 11.9 ± 15.1% and 16.6 ± 1.8% respectively, P < 0.05). The optimum cut-off of peripheral, central, and overall VI was 19.7%, 9.1% and 20.2% respectively. When compared to GSU alone, combination of VI assessment with GSU evaluation of thyroid nodules increased the diagnostic accuracy from 58.6% to 79.3% (P < 0.05). In conclusion, a novel algorithm for regional subdivision and quantification of thyroid nodular VI in ultrasound images was established, and the optimum offset and cut-off were derived. Assessment of intranodular VI in conjunction with GSU can increase the accuracy in ultrasound diagnosis of thyroid cancer.
- 30 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 14350
Open AccessComputer-aided assessment of regional vascularity of thyroid nodules for prediction of malignancy
Color Doppler vascular index (VI) was assessed alone and in combination with grey-scale ultrasound (GSU) in regionally subdivided thyroid nodules in diagnosing thyroid cancer. Color Doppler sonograms of 111 thyroid nodules were evaluated by a home-developed algorithm that performed “offsetting” (algorithm for changing the area of a region of interest, ROI, without distorting the ROI’s contour) and assessed peripheral, central and overall VI of thyroid nodules. Results showed that the optimum offset for dividing peripheral and central regions of nodule was 22%. At the optimum offset, the mean VI of peripheral, central, and overall regions of malignant nodules were significantly higher than those of benign nodules (26.5 ± 16.2%, 21.7 ± 19.6%, 23.8 ± 4.6% v/s 18.2 ± 16.7%, 11.9 ± 15.1% and 16.6 ± 1.8% respectively, P < 0.05). The optimum cut-off of peripheral, central, and overall VI was 19.7%, 9.1% and 20.2% respectively. When compared to GSU alone, combination of VI assessment with GSU evaluation of thyroid nodules increased the diagnostic accuracy from 58.6% to 79.3% (P < 0.05). In conclusion, a novel algorithm for regional subdivision and quantification of thyroid nodular VI in ultrasound images was established, and the optimum offset and cut-off were derived. Assessment of intranodular VI in conjunction with GSU can increase the accuracy in ultrasound diagnosis of thyroid cancer.
- Open Access
- 25 October 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (11) , 1103
Shear Wave Elastography Combining with Conventional Grey Scale Ultrasound Improves the Diagnostic Accuracy in Differentiating Benign and Malignant Thyroid Nodules
Shear wave elastography provides information about the stiffness of thyroid nodules that could be a new indicator of malignancy. The current study aimed to investigate the feasibility of using shear wave elastography (SWE) alone and in conjunction with grey scale ultrasound (GSU) to predict malignancy in 111 solitary thyroid nodules. Malignant thyroid nodules tended to have microcalcification, hypoechogenicity, tall to width ratio >1, and irregular borders (p < 0.05). SWE indices (Emaximum and Emean) of malignant nodules (median ± standard error: 85.2 ± 8.1 kPa and 26.6 ± 2.5 kPa) were significantly higher than those of benign nodules (median ± standard error: 50.3 ± 3.1 kPa and 20.2 ± 1 kPa) (p < 0.05). The optimal cut-off of Emaximum and Emean for distinguishing benign and malignant nodules was 67.3 kPa and 23.1 kPa, respectively. Diagnostic performances for GSU + Emaximum, GSU + Emean, GSU, Emaximum and Emean were: 70.4%, 74.1%, 96.3%, 70.4% and 74.1% for sensitivity, 83.3%, 79.8%, 46.4%, 70.2%, and 66.7% for specificity, and 80.2%, 78.4%, 58.5%, 70.3%, and 68.5% for accuracy, respectively. Our results suggested that combining GSU with SWE (using Emaximum or Emean) increased the overall diagnostic accuracy in distinguishing benign and malignant thyroid nodules.
- 25 October 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (11) , 1103
Open AccessShear Wave Elastography Combining with Conventional Grey Scale Ultrasound Improves the Diagnostic Accuracy in Differentiating Benign and Malignant Thyroid Nodules
Shear wave elastography provides information about the stiffness of thyroid nodules that could be a new indicator of malignancy. The current study aimed to investigate the feasibility of using shear wave elastography (SWE) alone and in conjunction with grey scale ultrasound (GSU) to predict malignancy in 111 solitary thyroid nodules. Malignant thyroid nodules tended to have microcalcification, hypoechogenicity, tall to width ratio >1, and irregular borders (p < 0.05). SWE indices (Emaximum and Emean) of malignant nodules (median ± standard error: 85.2 ± 8.1 kPa and 26.6 ± 2.5 kPa) were significantly higher than those of benign nodules (median ± standard error: 50.3 ± 3.1 kPa and 20.2 ± 1 kPa) (p < 0.05). The optimal cut-off of Emaximum and Emean for distinguishing benign and malignant nodules was 67.3 kPa and 23.1 kPa, respectively. Diagnostic performances for GSU + Emaximum, GSU + Emean, GSU, Emaximum and Emean were: 70.4%, 74.1%, 96.3%, 70.4% and 74.1% for sensitivity, 83.3%, 79.8%, 46.4%, 70.2%, and 66.7% for specificity, and 80.2%, 78.4%, 58.5%, 70.3%, and 68.5% for accuracy, respectively. Our results suggested that combining GSU with SWE (using Emaximum or Emean) increased the overall diagnostic accuracy in distinguishing benign and malignant thyroid nodules.