Élida Beatriz Hermida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Élida Beatriz Hermida has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
F. Povolo
Unidad de Actividad Materiales CAC–CNEA, San Martín, Argentina
18 shared publicationsOxana Yashchuk
UNSAM - National University of San Martín, Av. 25 de mayo 1169, (B1650HMK) San Martín, Buenos Aires, Argentina
3 shared publications- Daiana Nygaard
School of Science and Technology, National University of San Martín (UNSAM), Av. 25 de mayo 1147, B1650HMK, San Martín, Buenos Aires, Argentina
2 shared publications Diego G. Melo
Facultad de Ciencias Exactas y Naturales, Departamento Física , Universidad de Buenos Aires , Ciudad Universitaria, Pab. I, Buenos Aires, C1428, Argentina
2 shared publicationsF Povolo
2 shared publications- Mercedes Pérez-Recalde
Instituto de Tecnologías Emergentes y Ciencias Aplicadas (ITECA), National Scientific and Technical Research Council (CONICET), National University of General San Martin (UNSAM), San Martin 1650, Buenos Aires, Argentina
2 shared publications
Latest Publications
- Open Access
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Development of sustainable and tunable molasses-derived PHBV inks for 3D tissue engineering scaffolds using innovative in-situ viscosity monitoring
Transforming industrial molasses into high-value biomaterials, this study reports the development of sustainable, tunable 3D-printable inks based on poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) for biomedical applications. The extracted, purified, and characterized polymers exhibited high purity and an adjustable 3-hydroxyvalerate (3HV) content from 6.4 to 25.7 mol %. To engineer the inks, PHBV with varying 3HV ratios was formulated in chloroform at 13% w/v. As a key engineering contribution, an innovative low-volume, in-situ viscosity monitoring system utilizing a force resistive resistor (FSR) was developed to precisely measure rheological behavior under actual processing shear conditions. The apparent viscosity increased from 10 Pa·s to 22 Pa·s, directly linking polymer composition to the fluid properties. This platform enabled the fabrication of extrusion-based 3D-printed scaffolds with precisely controlled architectures and a tunable tensile modulus between 72 and 249 MPa, due to interlayer macromolecular interdiffusion. Based on these mechanical properties, the optimal formulation (19 mol % 3HV) was selected for in vitro biological validation using NIH3T3 fibroblasts. The optimized scaffolds demonstrated high cytocompatibility, achieving a cell viability of 101%. Optical and scanning electron microscopy analyses further revealed robust cell adhesion, spreading, and active migration throughout the interconnected network driven by architectural mechanotransduction cues. These results highlight the successful, integration of an innovative in-situ monitoring tool and a sustainable, tunable PHBV ink platform, offering a promising environmentally friendly engineering solution for future tissue regeneration.
- 31 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of sustainable and tunable molasses-derived PHBV inks for 3D tissue engineering scaffolds using innovative in-situ viscosity monitoring
Transforming industrial molasses into high-value biomaterials, this study reports the development of sustainable, tunable 3D-printable inks based on poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) for biomedical applications. The extracted, purified, and characterized polymers exhibited high purity and an adjustable 3-hydroxyvalerate (3HV) content from 6.4 to 25.7 mol %. To engineer the inks, PHBV with varying 3HV ratios was formulated in chloroform at 13% w/v. As a key engineering contribution, an innovative low-volume, in-situ viscosity monitoring system utilizing a force resistive resistor (FSR) was developed to precisely measure rheological behavior under actual processing shear conditions. The apparent viscosity increased from 10 Pa·s to 22 Pa·s, directly linking polymer composition to the fluid properties. This platform enabled the fabrication of extrusion-based 3D-printed scaffolds with precisely controlled architectures and a tunable tensile modulus between 72 and 249 MPa, due to interlayer macromolecular interdiffusion. Based on these mechanical properties, the optimal formulation (19 mol % 3HV) was selected for in vitro biological validation using NIH3T3 fibroblasts. The optimized scaffolds demonstrated high cytocompatibility, achieving a cell viability of 101%. Optical and scanning electron microscopy analyses further revealed robust cell adhesion, spreading, and active migration throughout the interconnected network driven by architectural mechanotransduction cues. These results highlight the successful, integration of an innovative in-situ monitoring tool and a sustainable, tunable PHBV ink platform, offering a promising environmentally friendly engineering solution for future tissue regeneration.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 98 (2) , e20241058
Potential of Cupriavidus necator as a versatile platform for producing a wide range of polyhydroxyalkanoates
Polyhydroxyalkanoates (PHAs) are bioplastics with increasing commercial interest due to their thermomechanical properties, which are comparable to those of petrochemical plastics. Furthermore, they biodegrade in various environments and biocompatible. Applications related to both packaging and biomedical purposes have therefore prompted research to improve their production. Among the microorganisms capable of producing them, Cupriavidus necator stands out as one of the most widely studied and efficient platforms and is the model microorganism for PHA production. This bacterium is highly versatile, capable of utilizing diverse carbon sources, from sugars and organic acids to CO2 and hydrogen, to produce a wide range of polymers in high concentrations. This review provides a comprehensive overview of C. necator covering its taxonomic history, metabolic pathways, and the genetic regulation of PHA synthesis. We examine the stoichiometry of growth and polymer production, presenting generalized equations for different carbon sources. Furthermore, we discuss the biotechnological production of PHAs, comparing performance between Erlenmeyer flasks and bioreactors, and analyzing the effect of different feeding strategies on polymer yield and composition. Finally, current challenges and prospects are addressed, emphasizing the potential of C. necator as a sustainable and versatile cell factory for the large-scale production of biopolymers.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 98 (2) , e20241058
Open AccessPotential of Cupriavidus necator as a versatile platform for producing a wide range of polyhydroxyalkanoates
Polyhydroxyalkanoates (PHAs) are bioplastics with increasing commercial interest due to their thermomechanical properties, which are comparable to those of petrochemical plastics. Furthermore, they biodegrade in various environments and biocompatible. Applications related to both packaging and biomedical purposes have therefore prompted research to improve their production. Among the microorganisms capable of producing them, Cupriavidus necator stands out as one of the most widely studied and efficient platforms and is the model microorganism for PHA production. This bacterium is highly versatile, capable of utilizing diverse carbon sources, from sugars and organic acids to CO2 and hydrogen, to produce a wide range of polymers in high concentrations. This review provides a comprehensive overview of C. necator covering its taxonomic history, metabolic pathways, and the genetic regulation of PHA synthesis. We examine the stoichiometry of growth and polymer production, presenting generalized equations for different carbon sources. Furthermore, we discuss the biotechnological production of PHAs, comparing performance between Erlenmeyer flasks and bioreactors, and analyzing the effect of different feeding strategies on polymer yield and composition. Finally, current challenges and prospects are addressed, emphasizing the potential of C. necator as a sustainable and versatile cell factory for the large-scale production of biopolymers.
- Open Access
Effects of Polyhydroxybutyrate-co-hydroxyvalerate Microparticle Loading on Rheology, Microstructure, and Processability of Hydrogel-Based Inks for Bioprinted and Moulded Scaffolds
Resorbable microparticles can be added to hydrogel-based biocompatible scaffolds to improve their mechanical characteristics and allow localised drug delivery, which will aid in tissue repair and regeneration. It is well-known that bioprinting is important for producing scaffolds personalised to patients by loading them with their own cells and printing them with specified shapes and dimensions. The question is how the addition of such particles affects the rheological responsiveness of the hydrogels (which is critical during the printing process) as well as mechanical parameters like the elastic modulus. This study tries to answer this question using a specific system: an alginate-gelatine hydrogel containing polyhydroxybutyrate-co-hydroxyvalerate (PHBV) microparticles. Scaffolds were made by bioprinting and moulding incorporating PHBV microspheres (7–12 μm in diameter) into alginate–gelatine inks (4.5 to 9.0% w/v). The microparticles (MP) were predominantly located within the polymeric matrix at concentrations up to 10 mg MP/mL ink. Higher particle concentrations disrupted their spatial distribution. Inks pre-crosslinked with 15 mM calcium and containingMPat concentrations ranging from 0 to 10 mg/mL demonstrated rheological characteristics appropriate for bioprinting, such as solid-like behaviour (G′ = 1060–1300 Pa, G″ = 720–930 Pa), yield stresses of 320–400 Pa, and pseudoplastic behaviour (static viscosities of 4000–5600 Pa·s and ~100 Pa·s at bioprinting shear rates). Furthermore, these inks allow high printing quality, assessed through scaffold dimensions, filament widths, and printability (Pr > 0.94). The modulus of elasticity in compression (E) of the scaffolds varied according to the content of MP and the manufacturing technique, with values resembling those of soft tissues (200–600 kPa) and exhibiting a maximum reinforcement effect with 3 mg MP/mL ink (bioprinted E = 273 ± 28 kPa; moulded E = 541 ± 66 kPa). Over the course of six days, the sample’s mass and shape remained stable during degradation in simulated body fluid (SBF). Thus, the alginate–gelatine hydrogel loaded with PHBV microspheres inks shows promise for targeted drug delivery in soft tissue bioengineering applications.
Open AccessEffects of Polyhydroxybutyrate-co-hydroxyvalerate Microparticle Loading on Rheology, Microstructure, and Processability of Hydrogel-Based Inks for Bioprinted and Moulded Scaffolds
Resorbable microparticles can be added to hydrogel-based biocompatible scaffolds to improve their mechanical characteristics and allow localised drug delivery, which will aid in tissue repair and regeneration. It is well-known that bioprinting is important for producing scaffolds personalised to patients by loading them with their own cells and printing them with specified shapes and dimensions. The question is how the addition of such particles affects the rheological responsiveness of the hydrogels (which is critical during the printing process) as well as mechanical parameters like the elastic modulus. This study tries to answer this question using a specific system: an alginate-gelatine hydrogel containing polyhydroxybutyrate-co-hydroxyvalerate (PHBV) microparticles. Scaffolds were made by bioprinting and moulding incorporating PHBV microspheres (7–12 μm in diameter) into alginate–gelatine inks (4.5 to 9.0% w/v). The microparticles (MP) were predominantly located within the polymeric matrix at concentrations up to 10 mg MP/mL ink. Higher particle concentrations disrupted their spatial distribution. Inks pre-crosslinked with 15 mM calcium and containingMPat concentrations ranging from 0 to 10 mg/mL demonstrated rheological characteristics appropriate for bioprinting, such as solid-like behaviour (G′ = 1060–1300 Pa, G″ = 720–930 Pa), yield stresses of 320–400 Pa, and pseudoplastic behaviour (static viscosities of 4000–5600 Pa·s and ~100 Pa·s at bioprinting shear rates). Furthermore, these inks allow high printing quality, assessed through scaffold dimensions, filament widths, and printability (Pr > 0.94). The modulus of elasticity in compression (E) of the scaffolds varied according to the content of MP and the manufacturing technique, with values resembling those of soft tissues (200–600 kPa) and exhibiting a maximum reinforcement effect with 3 mg MP/mL ink (bioprinted E = 273 ± 28 kPa; moulded E = 541 ± 66 kPa). Over the course of six days, the sample’s mass and shape remained stable during degradation in simulated body fluid (SBF). Thus, the alginate–gelatine hydrogel loaded with PHBV microspheres inks shows promise for targeted drug delivery in soft tissue bioengineering applications.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 97 (3) , e20241453
Creep of Alginate-Gelatin-Hyaluronic acid strands and cell viability after bioprinting
The success of 3D bioprinting in tissue engineering relies on i) precise bioink deposition for creating intricate tissue architectures and ii) good cell viability after printing. However, printed strands made of hydrogels are susceptible to time-dependent deformation —known as creep— which can compromise printing accuracy. Creep might be reduced by increasing the crosslink density, but this could be deleterious for cells in the bioink. Therefore, this study investigates the impact of creep on the printability of an Alginate-Gelatin-Hyaluronic acid bioink. Creep data were fitted with a linear rheological model that enables to predict the strand deformation over time. Furthermore, creep curves measured at different temperatures allow to determine an Arrhenius dependence of the parameters of the rheological model with time. The activation energies of the mechanisms involved in the rheological behavior of the bioink suggest that gelatin plays a significant role in the viscous response, while the network made by the entangled chains of alginate and hyaluronic acid is responsible for the anelastic deformation. This deformation decreased with simultaneous nebulization with CaCl2. Additionally, this bioink exhibited a high percentage of viable NIH/3T3 fibroblasts (78-90%) after 3D-bioprinting and Ca2+ immersion crosslinking processes.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 97 (3) , e20241453
Open AccessCreep of Alginate-Gelatin-Hyaluronic acid strands and cell viability after bioprinting
The success of 3D bioprinting in tissue engineering relies on i) precise bioink deposition for creating intricate tissue architectures and ii) good cell viability after printing. However, printed strands made of hydrogels are susceptible to time-dependent deformation —known as creep— which can compromise printing accuracy. Creep might be reduced by increasing the crosslink density, but this could be deleterious for cells in the bioink. Therefore, this study investigates the impact of creep on the printability of an Alginate-Gelatin-Hyaluronic acid bioink. Creep data were fitted with a linear rheological model that enables to predict the strand deformation over time. Furthermore, creep curves measured at different temperatures allow to determine an Arrhenius dependence of the parameters of the rheological model with time. The activation energies of the mechanisms involved in the rheological behavior of the bioink suggest that gelatin plays a significant role in the viscous response, while the network made by the entangled chains of alginate and hyaluronic acid is responsible for the anelastic deformation. This deformation decreased with simultaneous nebulization with CaCl2. Additionally, this bioink exhibited a high percentage of viable NIH/3T3 fibroblasts (78-90%) after 3D-bioprinting and Ca2+ immersion crosslinking processes.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (08) , 1448-1454
Device for Cell Culture under Variable Mechanical Stress by Controlling Deformation on its Substrate
Mechanotransduction can enhance cell cultures when its substrate is subjected to dynamic strain. This paper presents the design and implementation of a device that applies variable mechanical stress on a flexible biocompatible substrate. An embedded system implements a closed-loop PID control that acts on a proportional valve, which regulates the negative pressure in a chamber, generated by a miniature vacuum pump. The top cover of the chamber is a membrane that stretches according to the generated vacuum and is used for cell culture. The elastic modulus of the produced membrane was 260 kPa, similar to soft biological tissue. The deformation of the membrane was quantified by image processing and a linear pressure-deformation relationship was achieved (r and gt; 0.99). The controller was designed based on the identified valve's dynamic and it allowed variable deformations on the membrane with an amplitude of 20 % and a frequency of 2 Hz, selected by the user. The implemented device is PC independent and has a cost, size and weight almost two orders of magnitude lower than a similar commercial version.
- 9 June 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (08) , 1448-1454
Device for Cell Culture under Variable Mechanical Stress by Controlling Deformation on its Substrate
Mechanotransduction can enhance cell cultures when its substrate is subjected to dynamic strain. This paper presents the design and implementation of a device that applies variable mechanical stress on a flexible biocompatible substrate. An embedded system implements a closed-loop PID control that acts on a proportional valve, which regulates the negative pressure in a chamber, generated by a miniature vacuum pump. The top cover of the chamber is a membrane that stretches according to the generated vacuum and is used for cell culture. The elastic modulus of the produced membrane was 260 kPa, similar to soft biological tissue. The deformation of the membrane was quantified by image processing and a linear pressure-deformation relationship was achieved (r and gt; 0.99). The controller was designed based on the identified valve's dynamic and it allowed variable deformations on the membrane with an amplitude of 20 % and a frequency of 2 Hz, selected by the user. The implemented device is PC independent and has a cost, size and weight almost two orders of magnitude lower than a similar commercial version.
- 1 February 2020
- Published by Elsevier in Polymer Testing
- Vol. 82
Collagen and chitosan blends for 3D bioprinting: A rheological and printability approach
- 1 February 2020
- Published by Elsevier in Polymer Testing
- Vol. 82
Collagen and chitosan blends for 3D bioprinting: A rheological and printability approach
- 1 January 2018
- Published by Elsevier in Phytomedicine
- Vol. 38, 57-65
Could essential oils enhance biopolymers performance for wound healing? A systematic review
- 1 January 2018
- Published by Elsevier in Phytomedicine
- Vol. 38, 57-65
Could essential oils enhance biopolymers performance for wound healing? A systematic review
- 1 August 2016
- Published by Elsevier in Polymer Testing
- Vol. 53, 58-69
Evaluation of the rate of abiotic and biotic degradation of oxo-degradable polyethylene
- 1 August 2016
- Published by Elsevier in Polymer Testing
- Vol. 53, 58-69
Evaluation of the rate of abiotic and biotic degradation of oxo-degradable polyethylene