Amina Rezkallah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amina Rezkallah has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Laurent Kodjikian
Department of Ophthalmology, Croix-Rousse University Hospital, Hospices Civils de Lyon, 69002 Lyon, France
14 shared publications - Thibaud Mathis
Ophthalmology Department Croix‐Rousse University Hospital, Hospices Civils de Lyon Lyon France
13 shared publications Philippe Denis
Service d'Ophtalmologie, Hôpital de la Croix-Rousse, Hospices Civils de Lyon, Lyon, France
6 shared publicationsP. Denis
Service d'ophtalmologie, hôpital de la Croix-Rousse, hospices civils de Lyon, 103, Grande-rue de la Croix-Rousse, 69317 Lyon cedex 4, France
5 shared publicationsT. Mathis
Service d'ophtalmologie, hôpital de la Croix-Rousse, hospices civils de Lyon, 103, Grande-rue de la Croix-Rousse, 69317 Lyon cedex 4, France; UMR-CNRS 5510 Matéis, université de médicine Lyon 1, Lyon, France
4 shared publications- Frédéric Matonti
Centre Monticelli Paradis, Marseille, France
3 shared publications
Latest Publications
- 7 October 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
Performance of 24-2C Visual Field Grid in Detecting Central Glaucomatous Defects: A Comparative Study with Microperimetry
Precis: Our study shows that the 24-2C VF test provides central functional information strongly correlated with 10-2 and MAIA measurements, with a shorter testing time. It may serve as a useful complementary tool in routine glaucoma assessment. Purpose: To compare performance of 24-2C visual field (VF) grid and microperimetry in detecting central defects in glaucoma patients, and to correlate perimetric parameters with anatomical alterations. Materials and Methods: This cross-sectional, single-center study included 214 eyes (118 glaucoma, 96 healthy). Participants underwent VF testing using 24-2C SITA-Faster, MAcular Integrity Assessment (MAIA) microperimetry, and 10-2 SITA-Standard grids. Macular imaging, including ganglion cell-inner plexiform layer complex (GC-IPL) analysis, was performed using Cirrus OCT. The primary outcome was a comparison of global indices between 24-2C grid and microperimetry. Secondary outcomes included comparisons with 10-2 grid, structure-function correlation, test duration, and 24-2C grid performance based on glaucoma severity. Results: 24-2C Mean Deviation (MD) correlated significantly ( P P P <0.001), particularly in the superior nasal sector (r=0.631). 24-2C grid demonstrated a stronger correlation with microperimetry for CMS, with r=0.674 in early-stage glaucoma and r=0.651 in advanced-stage glaucoma. Conclusion: 24-2C VF grid has a potential complementary role in glaucoma assessment for detecting central VF defects in glaucoma patients. Its structure-function correlation supports its use as a promising tool in routine clinical practice.
- 7 October 2026
- Published by Wolters Kluwer Health in Journal of Glaucoma
Performance of 24-2C Visual Field Grid in Detecting Central Glaucomatous Defects: A Comparative Study with Microperimetry
Precis: Our study shows that the 24-2C VF test provides central functional information strongly correlated with 10-2 and MAIA measurements, with a shorter testing time. It may serve as a useful complementary tool in routine glaucoma assessment. Purpose: To compare performance of 24-2C visual field (VF) grid and microperimetry in detecting central defects in glaucoma patients, and to correlate perimetric parameters with anatomical alterations. Materials and Methods: This cross-sectional, single-center study included 214 eyes (118 glaucoma, 96 healthy). Participants underwent VF testing using 24-2C SITA-Faster, MAcular Integrity Assessment (MAIA) microperimetry, and 10-2 SITA-Standard grids. Macular imaging, including ganglion cell-inner plexiform layer complex (GC-IPL) analysis, was performed using Cirrus OCT. The primary outcome was a comparison of global indices between 24-2C grid and microperimetry. Secondary outcomes included comparisons with 10-2 grid, structure-function correlation, test duration, and 24-2C grid performance based on glaucoma severity. Results: 24-2C Mean Deviation (MD) correlated significantly ( P P P <0.001), particularly in the superior nasal sector (r=0.631). 24-2C grid demonstrated a stronger correlation with microperimetry for CMS, with r=0.674 in early-stage glaucoma and r=0.651 in advanced-stage glaucoma. Conclusion: 24-2C VF grid has a potential complementary role in glaucoma assessment for detecting central VF defects in glaucoma patients. Its structure-function correlation supports its use as a promising tool in routine clinical practice.
- 14 August 2023
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 46 (10) , e361-e364
Glaucoma and conjunctival fibrosis: A case report
- 14 August 2023
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 46 (10) , e361-e364
Glaucoma and conjunctival fibrosis: A case report
- Open Access
- 29 May 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (6) , 1607
Relevance of Visual Acuity Measurement for Therapeutic Decisions in Diabetic Macular Edema
This study aimed to determine the validity of basing retreatment decisions on anatomical criteria alone (captured using optical coherence tomography (OCT)—OCT-guided strategy) rather than the gold standard (combined visual acuity (VA) and OCT) in patients with diabetic macular edema (DME). This cross-sectional study included 81 eyes undergoing treatment for DME from September 2021 to December 2021. An initial therapeutic treatment decision based on OCT results was made on inclusion. Subsequently, in light of the patient’s VA score, this initial decision was upheld or adjusted, and the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. In 67 out of the 81 eyes included in the study (82.7%), the OCT-guided strategy produced equivalent results to the gold standard. In this study, the OCT-guided retreatment decision strategy yielded sensitivity and specificity of 92.3% and 73.8%, respectively, and PPV and NPV of 76.6% and 91.2%, respectively. These findings differed according to the patient’s treatment regimen: the sensitivity and specificity for eyes under a treat and extend regimen was higher, 100% and 88.9%, respectively, than eyes under a Pro Re Nata regimen, 90% and 69.7%, respectively. These findings show that VA testing could be omitted from the follow-up of certain patients with DME treated with intravitreal injections without impacting the quality of care.
- 29 May 2023
- Published by MDPI AG in Pharmaceutics
- Vol. 15 (6) , 1607
Open AccessRelevance of Visual Acuity Measurement for Therapeutic Decisions in Diabetic Macular Edema
This study aimed to determine the validity of basing retreatment decisions on anatomical criteria alone (captured using optical coherence tomography (OCT)—OCT-guided strategy) rather than the gold standard (combined visual acuity (VA) and OCT) in patients with diabetic macular edema (DME). This cross-sectional study included 81 eyes undergoing treatment for DME from September 2021 to December 2021. An initial therapeutic treatment decision based on OCT results was made on inclusion. Subsequently, in light of the patient’s VA score, this initial decision was upheld or adjusted, and the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. In 67 out of the 81 eyes included in the study (82.7%), the OCT-guided strategy produced equivalent results to the gold standard. In this study, the OCT-guided retreatment decision strategy yielded sensitivity and specificity of 92.3% and 73.8%, respectively, and PPV and NPV of 76.6% and 91.2%, respectively. These findings differed according to the patient’s treatment regimen: the sensitivity and specificity for eyes under a treat and extend regimen was higher, 100% and 88.9%, respectively, than eyes under a Pro Re Nata regimen, 90% and 69.7%, respectively. These findings show that VA testing could be omitted from the follow-up of certain patients with DME treated with intravitreal injections without impacting the quality of care.
- 20 April 2023
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 46 (6) , 680-682
Kystotomie irienne au laser YAG
- 20 April 2023
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 46 (6) , 680-682
Kystotomie irienne au laser YAG
- Open Access
- 9 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 522
Relevance of Visual Acuity Measurement for Therapeutic Decisions in Age-Related Macular Degeneration
The aim of this study is to assess if the decision to retreat could be determined by anatomical criteria (mostly driven by optical coherence tomography (OCT)-guided strategy) rather than the gold standard (visual acuity (VA) and OCT) in patients with neovascular age-related macular degeneration (nAMD). A cross-sectional study of 142 eyes already treated for nAMD from September 2021 to December 2021 was performed. At inclusion, a first therapeutic decision was made based on the analysis of the OCT. This decision was then maintained or modified after being made aware of the patient’s VA. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. The OCT-guided strategy matched the gold standard for treatment decisions in 131 of the 142 eyes included (92.3%). The sensitivity and specificity of the OCT-guided strategy for the retreatment decision were 94.0% and 89.8%, respectively. PPV and NPV were 92.9% and 91.4%, respectively. Considering the treatment regimen, eyes followed under the Pro ReNata regimen showed better sensitivity (100%) and specificity (93.3%) than eyes followed under the treat and extend regimen (93.5% and 88.6%, respectively). Based on the findings of this study, the follow-up for selected patients with nAMD under anti-VEGF treatment could be monitored without regular VA testing with acceptable performance.
- 9 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 522
Open AccessRelevance of Visual Acuity Measurement for Therapeutic Decisions in Age-Related Macular Degeneration
The aim of this study is to assess if the decision to retreat could be determined by anatomical criteria (mostly driven by optical coherence tomography (OCT)-guided strategy) rather than the gold standard (visual acuity (VA) and OCT) in patients with neovascular age-related macular degeneration (nAMD). A cross-sectional study of 142 eyes already treated for nAMD from September 2021 to December 2021 was performed. At inclusion, a first therapeutic decision was made based on the analysis of the OCT. This decision was then maintained or modified after being made aware of the patient’s VA. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. The OCT-guided strategy matched the gold standard for treatment decisions in 131 of the 142 eyes included (92.3%). The sensitivity and specificity of the OCT-guided strategy for the retreatment decision were 94.0% and 89.8%, respectively. PPV and NPV were 92.9% and 91.4%, respectively. Considering the treatment regimen, eyes followed under the Pro ReNata regimen showed better sensitivity (100%) and specificity (93.3%) than eyes followed under the treat and extend regimen (93.5% and 88.6%, respectively). Based on the findings of this study, the follow-up for selected patients with nAMD under anti-VEGF treatment could be monitored without regular VA testing with acceptable performance.
- Open Access
- 16 December 2022
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 13 (3) , 1024-1029
Preserflo Microshunt Surgery for Ocular Hypertension following Intravitreal Fluocinolone Acetonide Implant Removal: A Case Report
Diabetic macular edema (DME) is now a well-known condition for which a number of treatments have been shown to be effective. Intraocular corticosteroids are part of this therapeutic arsenal but are sometimes responsible for ocular hypertension. We describe here the case of a 60-year-old man with a history of bilateral DME who received an intravitreal injection of 190 µg fluocinolone acetonide (FAc) (ILUVIEN®, Alimera Sciences, Alpharetta, GA, USA) who presented a persistent ocular hypertension in one eye despite FAc removal by pars plana vitrectomy and was successfully managed by Preserflo® microshunt surgery.
- 16 December 2022
- Published by S. Karger AG in Case Reports in Ophthalmology
- Vol. 13 (3) , 1024-1029
Open AccessPreserflo Microshunt Surgery for Ocular Hypertension following Intravitreal Fluocinolone Acetonide Implant Removal: A Case Report
Diabetic macular edema (DME) is now a well-known condition for which a number of treatments have been shown to be effective. Intraocular corticosteroids are part of this therapeutic arsenal but are sometimes responsible for ocular hypertension. We describe here the case of a 60-year-old man with a history of bilateral DME who received an intravitreal injection of 190 µg fluocinolone acetonide (FAc) (ILUVIEN®, Alimera Sciences, Alpharetta, GA, USA) who presented a persistent ocular hypertension in one eye despite FAc removal by pars plana vitrectomy and was successfully managed by Preserflo® microshunt surgery.
- 27 September 2022
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 45 (9) , 1095-1096
Obstruction d’un MIGS
- 27 September 2022
- Published by Elsevier in Journal Français d'Ophtalmologie
- Vol. 45 (9) , 1095-1096
Obstruction d’un MIGS
- Open Access
- 23 August 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (9) , 1756
Intra-Ocular Pressure Response to Dexamethasone Implant Injections in Patients with a History of Filtering Surgery: The TRABEX Study
Patients with both macular edemas, of various etiologies such as diabetes and glaucoma, may suffer serious loss of vision if either disease goes untreated. Where no effective alternative therapies are available, dexamethasone implant (DEX-I) injections may be the only choice of treatment, despite the risk of a possible increase in intraocular pressure (IOP) when using steroids. Although many studies have reported on IOP evolution in eyes treated with DEX-I, little is known specifically about eyes with a history of filtering surgery. The aim of this observational series was to evaluate the IOP response following DEX-I injection in eyes presenting conventional filtering surgeries or microinvasive glaucoma surgeries (MIGS). Twenty-five eyes were included in this study. A total of 64% of the eyes did not experience OHT during follow-up. Additional IOP-lowering therapy was needed for 32% of eyes, and 20% of eyes (all showing bleb fibrosis) required further filtering surgery: 50% of eyes in the MIGS group and 10.5% of eyes in the conventional filtering surgery group. A significant positive correlation was found between IOP at baseline and the maximum IOP throughout follow-ups after DEX-I (r = 0.45, p = 0.02). In conclusion, if DEX-I is used when there are no alternative therapies for treating macular edema, IOP in eyes with a history of filtering surgery is generally manageable. Those eyes which previously underwent conventional therapy with effective blebs obtained better IOP control after DEX-I injections and mostly did not require any additional IOP-lowering therapy or surgery.
- 23 August 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (9) , 1756
Open AccessIntra-Ocular Pressure Response to Dexamethasone Implant Injections in Patients with a History of Filtering Surgery: The TRABEX Study
Patients with both macular edemas, of various etiologies such as diabetes and glaucoma, may suffer serious loss of vision if either disease goes untreated. Where no effective alternative therapies are available, dexamethasone implant (DEX-I) injections may be the only choice of treatment, despite the risk of a possible increase in intraocular pressure (IOP) when using steroids. Although many studies have reported on IOP evolution in eyes treated with DEX-I, little is known specifically about eyes with a history of filtering surgery. The aim of this observational series was to evaluate the IOP response following DEX-I injection in eyes presenting conventional filtering surgeries or microinvasive glaucoma surgeries (MIGS). Twenty-five eyes were included in this study. A total of 64% of the eyes did not experience OHT during follow-up. Additional IOP-lowering therapy was needed for 32% of eyes, and 20% of eyes (all showing bleb fibrosis) required further filtering surgery: 50% of eyes in the MIGS group and 10.5% of eyes in the conventional filtering surgery group. A significant positive correlation was found between IOP at baseline and the maximum IOP throughout follow-ups after DEX-I (r = 0.45, p = 0.02). In conclusion, if DEX-I is used when there are no alternative therapies for treating macular edema, IOP in eyes with a history of filtering surgery is generally manageable. Those eyes which previously underwent conventional therapy with effective blebs obtained better IOP control after DEX-I injections and mostly did not require any additional IOP-lowering therapy or surgery.
- Open Access
- 19 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (16) , 4880
Evaluation of the Correlation between Regional Retinal Ganglion Cell Damage and Visual Field Sensitivity in Patients with Advanced Glaucoma
(1) Background: to investigate the correlation between structural (retinal ganglion cells and retinal nerve fibers) and functional alterations analyzed point-by-point in the central 10 degrees of the visual field of patients with advanced glaucoma using Humphrey 10-2 visual field tests. (2) Methods: Single-center prospective cohort study carried on from October 2018 to February 2019 at the Croix-Rousse hospital, Lyon, France. The primary outcome measure was the point-by-point correlation between retinal sensitivity (Humphrey 10-2) and retinal ganglion cell complex (GCC) thickness. (3) Results: 29 eyes of 27 patients were examined. Of these, 15 eyes had a mean deviation (MD) less than −20 dB. There were statistically significant linear relationships between GCC thickness and 10-2 visual field sensitivity for several points in the lower part of the visual field, with lower retinal sensitivity being associated with thicker GCC layers. There were no strong linear relationships or statistically significant correlations in the other regions of the visual field. For the patients with MD < −20 dB, there were statistically significant linear relationships between GCC thickness and 10-2 visual field sensitivity for several points in the superior nasal region. Retinal sensitivity was not correlated with retinal nerve fibre layer thickness. (4) Conclusions: In this study of patients with advanced glaucoma, GCC thickness was linearly associated with 10-2 visual field sensitivity in certain regions, negatively for patients with less-severe glaucoma. The initial thickening raises questions about the apoptosis mechanism, while the thinning observed in the most severe cases is consistent with the ganglion cell death identified on visual field tests.
- 19 August 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (16) , 4880
Open AccessEvaluation of the Correlation between Regional Retinal Ganglion Cell Damage and Visual Field Sensitivity in Patients with Advanced Glaucoma
(1) Background: to investigate the correlation between structural (retinal ganglion cells and retinal nerve fibers) and functional alterations analyzed point-by-point in the central 10 degrees of the visual field of patients with advanced glaucoma using Humphrey 10-2 visual field tests. (2) Methods: Single-center prospective cohort study carried on from October 2018 to February 2019 at the Croix-Rousse hospital, Lyon, France. The primary outcome measure was the point-by-point correlation between retinal sensitivity (Humphrey 10-2) and retinal ganglion cell complex (GCC) thickness. (3) Results: 29 eyes of 27 patients were examined. Of these, 15 eyes had a mean deviation (MD) less than −20 dB. There were statistically significant linear relationships between GCC thickness and 10-2 visual field sensitivity for several points in the lower part of the visual field, with lower retinal sensitivity being associated with thicker GCC layers. There were no strong linear relationships or statistically significant correlations in the other regions of the visual field. For the patients with MD < −20 dB, there were statistically significant linear relationships between GCC thickness and 10-2 visual field sensitivity for several points in the superior nasal region. Retinal sensitivity was not correlated with retinal nerve fibre layer thickness. (4) Conclusions: In this study of patients with advanced glaucoma, GCC thickness was linearly associated with 10-2 visual field sensitivity in certain regions, negatively for patients with less-severe glaucoma. The initial thickening raises questions about the apoptosis mechanism, while the thinning observed in the most severe cases is consistent with the ganglion cell death identified on visual field tests.
- 16 June 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (4) , NP32-NP36
XEN® 63 gel stent to treat a refractory uveitic glaucoma: A case report
Purpose: To describe the effectiveness of the XEN® 63 gel stent in a refractory uveitic glaucoma after failure of an Ahmed Glaucoma Valve. Case description: We report the case of a 54-year-old man with a history of uveitic glaucoma on his left eye due to Fuchs heterochromic iridocyclitis and neovascular glaucoma after a central retinal vein occlusion. Pre-operative intraocular pressure was 30 mmHg despite a QD (once-daily) dosed bimatoprost 0.3 mg and timolol 5 mg topical medication. At week 1, the eye exam showed an intraocular pressure of 6 mmHg with a well-formed bleb, a very mild hyphema and a localized choroidal detachment. At month 1, intraocular pressure was 14 mmHg with a formed bleb. Both hyphema and choroidal detachments had resolved. After a year, intraocular pressure was 16 mmHg without any medication and the bleb was still well-formed. Conclusion: The XEN® 63 gel stent provides a good intraocular pressure reduction and can be an efficient alternative for tube and filtration surgery in refractory glaucoma. Its long-term effectiveness needs to be evaluated.
- 16 June 2022
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (4) , NP32-NP36
XEN® 63 gel stent to treat a refractory uveitic glaucoma: A case report
Purpose: To describe the effectiveness of the XEN® 63 gel stent in a refractory uveitic glaucoma after failure of an Ahmed Glaucoma Valve. Case description: We report the case of a 54-year-old man with a history of uveitic glaucoma on his left eye due to Fuchs heterochromic iridocyclitis and neovascular glaucoma after a central retinal vein occlusion. Pre-operative intraocular pressure was 30 mmHg despite a QD (once-daily) dosed bimatoprost 0.3 mg and timolol 5 mg topical medication. At week 1, the eye exam showed an intraocular pressure of 6 mmHg with a well-formed bleb, a very mild hyphema and a localized choroidal detachment. At month 1, intraocular pressure was 14 mmHg with a formed bleb. Both hyphema and choroidal detachments had resolved. After a year, intraocular pressure was 16 mmHg without any medication and the bleb was still well-formed. Conclusion: The XEN® 63 gel stent provides a good intraocular pressure reduction and can be an efficient alternative for tube and filtration surgery in refractory glaucoma. Its long-term effectiveness needs to be evaluated.