Serge Meimon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serge Meimon has a total of 250 co-authors. Here are the top co-authors by number of shared publications:
- Laurent M. Mugnier
DOTA, ONERA, Université Paris Saclay
16 shared publications Cyril Petit
15 shared publicationsThierry Fusco
Université Paris-Saclay
14 shared publicationsMichel Paques
Quinze-Vingts National Ophthalmology Hospital
13 shared publications- Pedro Mecê
Institut Langevin, ESPCI Paris, CNRS, PSL University, Paris, France
13 shared publications Jean-Marc Conan
11 shared publications
Latest Publications
- 25 June 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (21) , 7193
Shack–Hartmann wavefront sensing on extended source: experimental assessment of the impact of anisoplanatism
Atmospheric turbulence limits ground-to-target laser focusing, particularly for slant-path propagation where anisoplanatism degrades adaptive optics (AO) performance. We investigate the impact of the complex amplitude anisoplanatism measurement error on Shack–Hartmann wavefront sensing of extended targets. An experiment is specifically designed to enable the separation of phase and amplitude fluctuations, as well as their coupling. The setup allows an independent assessment of the main error contributions under representative conditions. Experimental results are compared with theoretical predictions, providing validation of the different error terms and insight into their relative impact on AO performance.
- 25 June 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (21) , 7193
Shack–Hartmann wavefront sensing on extended source: experimental assessment of the impact of anisoplanatism
Atmospheric turbulence limits ground-to-target laser focusing, particularly for slant-path propagation where anisoplanatism degrades adaptive optics (AO) performance. We investigate the impact of the complex amplitude anisoplanatism measurement error on Shack–Hartmann wavefront sensing of extended targets. An experiment is specifically designed to enable the separation of phase and amplitude fluctuations, as well as their coupling. The setup allows an independent assessment of the main error contributions under representative conditions. Experimental results are compared with theoretical predictions, providing validation of the different error terms and insight into their relative impact on AO performance.
- Open Access
- 27 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (26) , eadx2941
Revealing neurovascular coupling at a high spatial and temporal resolution in the living human retina
Neurovascular coupling (NVC) regulates local blood flow in response to neuronal activity, yet its precise characterization at the capillary level has been hindered by the lack of a noninvasive, high-resolution imaging method. Here, we introduce the adaptive optics rolling slit ophthalmoscope, a unique noninvasive, label-free, high-speed, cellular-resolution clinical imaging system for assessing retinal NVC in the living human eye. Using an off-axis phase contrast approach combined with camera-based confocal slit gating, our method provides large field-of-view imaging of arterial and venular walls, enabling the study of vascular dynamics with unprecedented spatiotemporal precision. Our findings highlight that this level of precision is essential for accurately distinguishing NVC-driven vasodilation from spontaneous fluctuations, such as vasomotion and the cardiac cycle. By bridging the gap between fundamental neurovascular research and clinical applications, this approach offers a powerful tool for neuroscience research and early disease detection and monitoring of neurodegenerative and vascular disorders.
- 27 June 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (26) , eadx2941
Open AccessRevealing neurovascular coupling at a high spatial and temporal resolution in the living human retina
Neurovascular coupling (NVC) regulates local blood flow in response to neuronal activity, yet its precise characterization at the capillary level has been hindered by the lack of a noninvasive, high-resolution imaging method. Here, we introduce the adaptive optics rolling slit ophthalmoscope, a unique noninvasive, label-free, high-speed, cellular-resolution clinical imaging system for assessing retinal NVC in the living human eye. Using an off-axis phase contrast approach combined with camera-based confocal slit gating, our method provides large field-of-view imaging of arterial and venular walls, enabling the study of vascular dynamics with unprecedented spatiotemporal precision. Our findings highlight that this level of precision is essential for accurately distinguishing NVC-driven vasodilation from spontaneous fluctuations, such as vasomotion and the cardiac cycle. By bridging the gap between fundamental neurovascular research and clinical applications, this approach offers a powerful tool for neuroscience research and early disease detection and monitoring of neurodegenerative and vascular disorders.
- Open Access
- 24 June 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (7) , 2923-2944
In vivo structured illumination ophthalmoscopy demonstration on the human retina using adaptive optics
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to high-resolution live imaging has been mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, multiple scattering, sample-induced optical aberrations, and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for moving and thick tissue, we successfully apply SIM to in vivo retinal imaging and demonstrate structured illumination ophthalmoscopy with optical sectioning and resolution improvement for in vivo imaging of the human retina.
- 24 June 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (7) , 2923-2944
Open AccessIn vivo structured illumination ophthalmoscopy demonstration on the human retina using adaptive optics
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to high-resolution live imaging has been mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, multiple scattering, sample-induced optical aberrations, and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for moving and thick tissue, we successfully apply SIM to in vivo retinal imaging and demonstrate structured illumination ophthalmoscopy with optical sectioning and resolution improvement for in vivo imaging of the human retina.
- Open Access
Adaptive Optics Rolling Slit Ophthalmoscope: Combining cellular-resolution, high-speed and large field-of-view in a multimodal retinal imager
Label-free optical imaging systems capable of monitoring dynamic biological processes over a large field-of-view (FOV) are essential for advancing our understanding of retinal and neurovascular health. However, existing imaging modalities often involve trade-offs between spatial resolution, contrast, FOV, and frame rate. In this study, we present the Adaptive Optics Rolling Slit Ophthalmoscope (AO-RSO), a novel imaging system that integrates the high-speed, wide-FOV capabilities of camera-based systems with the enhanced contrast and multimodal functionality of point-scanning techniques—without compromising resolution or speed. The AO-RSO utilizes line illumination synchronized with the rolling shutter of a high-speed sCMOS camera, enabling precise and dynamic spatial selection of detected photons: back-scattered photons for near-confocal bright-field imaging and forward-scattered photons for phase-contrast imaging of translucent retinal features. This system successfully visualizes diverse retinal structures, including cone and rod photoreceptors, nerve fiber bundles, red blood cells, vessel walls, and ganglion cells, across a wide retinal area (4.5°× 2.5°). With a large FOV and frame rates up to 200 Hz, the AO-RSO enables the quantification of blood flow, tracking of red blood cells within hundreds of capillaries, and evaluation of thousands of photoreceptors in the living human retina. This capability opens new opportunities for functional neuronal imaging, neurovascular coupling studies, and the early detection of retinal and neurodegenerative diseases.
Open AccessAdaptive Optics Rolling Slit Ophthalmoscope: Combining cellular-resolution, high-speed and large field-of-view in a multimodal retinal imager
Label-free optical imaging systems capable of monitoring dynamic biological processes over a large field-of-view (FOV) are essential for advancing our understanding of retinal and neurovascular health. However, existing imaging modalities often involve trade-offs between spatial resolution, contrast, FOV, and frame rate. In this study, we present the Adaptive Optics Rolling Slit Ophthalmoscope (AO-RSO), a novel imaging system that integrates the high-speed, wide-FOV capabilities of camera-based systems with the enhanced contrast and multimodal functionality of point-scanning techniques—without compromising resolution or speed. The AO-RSO utilizes line illumination synchronized with the rolling shutter of a high-speed sCMOS camera, enabling precise and dynamic spatial selection of detected photons: back-scattered photons for near-confocal bright-field imaging and forward-scattered photons for phase-contrast imaging of translucent retinal features. This system successfully visualizes diverse retinal structures, including cone and rod photoreceptors, nerve fiber bundles, red blood cells, vessel walls, and ganglion cells, across a wide retinal area (4.5°× 2.5°). With a large FOV and frame rates up to 200 Hz, the AO-RSO enables the quantification of blood flow, tracking of red blood cells within hundreds of capillaries, and evaluation of thousands of photoreceptors in the living human retina. This capability opens new opportunities for functional neuronal imaging, neurovascular coupling studies, and the early detection of retinal and neurodegenerative diseases.
- Open Access
Measuring flicker induced vasodilation at a high spatial and temporal resolution in the human retina
Neurovascular coupling (NVC) is a crucial process in which blood flow is dynamically adjusted to meet the metabolic demands of active neurons. In this study, we introduce an innovative method for in-vivo imaging of retinal blood vessel dilation in response to visible light stimulation, offering insights into the functional regulation of retinal blood flow. Using high-resolution, high-speed phase contrast imaging, we continuously monitored retinal vessel dynamics in eight healthy subjects, capturing precise temporal and spatial changes in vessel size under both stimulated and baseline conditions. We have measured a significant vessel dilation of 5.2% ± 1.6% (4.4 µm ± 1.3 µm) during flicker-stimulation compared to a dilation of 2.5% ± 1% (2.1 µm ± 0.9 µm) without stimulation. The flexibility of our method also allowed for the exploration of various acquisition and stimulation settings, broadening possibilities for investigating neurovascular coupling in the retina. This work not only enhances our understanding of neurovascular coupling but also has the potential to identify new biomarkers for vision-impairing conditions and neurodegenerative diseases. Significance: Neurovascular coupling is a fundamental mechanism of the brain which locally regulates blood flow in response to changes in neuronal activity. Here, we present a new imaging technique that enables measuring vasodilation in response to visible light stimulation of the neurons at high spatial and temporal resolution in the living human retina. Owing to the unprecedented measurement precision of the presented technique, we provide new insights into the inner working of functional blood flow regulation in the retina. Clinically, this method holds promise for vascular dysfunction early detection, which can improve diagnosis of retinal and neurodegenerative diseases, as well as assist the development of new targeted therapies.
Open AccessMeasuring flicker induced vasodilation at a high spatial and temporal resolution in the human retina
Neurovascular coupling (NVC) is a crucial process in which blood flow is dynamically adjusted to meet the metabolic demands of active neurons. In this study, we introduce an innovative method for in-vivo imaging of retinal blood vessel dilation in response to visible light stimulation, offering insights into the functional regulation of retinal blood flow. Using high-resolution, high-speed phase contrast imaging, we continuously monitored retinal vessel dynamics in eight healthy subjects, capturing precise temporal and spatial changes in vessel size under both stimulated and baseline conditions. We have measured a significant vessel dilation of 5.2% ± 1.6% (4.4 µm ± 1.3 µm) during flicker-stimulation compared to a dilation of 2.5% ± 1% (2.1 µm ± 0.9 µm) without stimulation. The flexibility of our method also allowed for the exploration of various acquisition and stimulation settings, broadening possibilities for investigating neurovascular coupling in the retina. This work not only enhances our understanding of neurovascular coupling but also has the potential to identify new biomarkers for vision-impairing conditions and neurodegenerative diseases. Significance: Neurovascular coupling is a fundamental mechanism of the brain which locally regulates blood flow in response to changes in neuronal activity. Here, we present a new imaging technique that enables measuring vasodilation in response to visible light stimulation of the neurons at high spatial and temporal resolution in the living human retina. Owing to the unprecedented measurement precision of the presented technique, we provide new insights into the inner working of functional blood flow regulation in the retina. Clinically, this method holds promise for vascular dysfunction early detection, which can improve diagnosis of retinal and neurodegenerative diseases, as well as assist the development of new targeted therapies.
- 11 July 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (14) , 3785-3788
Multimodal high-resolution retinal imaging using a camera-based DMD-integrated adaptive optics flood-illumination ophthalmoscope
We demonstrate the feasibility of a multimodal adaptive optics flood-illumination ophthalmoscope, able to provide both bright-field and dark-field images (such as phase contrast). The multimodality was made possible by integrating a digital micromirror device (DMD) at the illumination path to project a sequence of complementary high-resolution patterns into the retina. Through a versatile post-processing method that digitally selects backscattered or multiply scattered photons, we were able: (1) to achieve up to four-fold contrast increase of bright-field images when imaging the photoreceptor mosaic and nerve fibers; and (2) to visualize translucent retinal features such as capillaries, red blood cells, vessel walls, ganglion cells, and photoreceptor inner segments through phase contrast.
- 11 July 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (14) , 3785-3788
Multimodal high-resolution retinal imaging using a camera-based DMD-integrated adaptive optics flood-illumination ophthalmoscope
We demonstrate the feasibility of a multimodal adaptive optics flood-illumination ophthalmoscope, able to provide both bright-field and dark-field images (such as phase contrast). The multimodality was made possible by integrating a digital micromirror device (DMD) at the illumination path to project a sequence of complementary high-resolution patterns into the retina. Through a versatile post-processing method that digitally selects backscattered or multiply scattered photons, we were able: (1) to achieve up to four-fold contrast increase of bright-field images when imaging the photoreceptor mosaic and nerve fibers; and (2) to visualize translucent retinal features such as capillaries, red blood cells, vessel walls, ganglion cells, and photoreceptor inner segments through phase contrast.
- 13 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47179-47198
Feasibility demonstration of AO pre-compensation for GEO feeder links in a relevant environment
Optical technologies are extremely competitive candidates to achieve very-high throughput links between ground and GEO satellites; however, their feasibility relies on the ability to mitigate channel impairments due to atmospheric turbulence. For that purpose, Adaptive Optics (AO) has already proved to be highly efficient on the downlink. However, for the uplink, anisoplanatism induced by point-ahead angle (PAA) compromises AO pre-compensation efficiency to an extent that depends on propagation conditions. The ability to properly assess the anisoplanatism impact in a wide variety of conditions is thus critical in designing the optical ground terminals. In this paper, we demonstrate the consistency of experimental coupled flux statistics with results coming from performance and end-to-end models, on an AO pre-compensated 13 km slant path in Tenerife. This validation is demonstrated in a wide variety of turbulence conditions, hence consolidating propagation channel models that are of critical importance for the reliability of future GEO feeder links. We then compare experimental results to theoretical on-sky performance, and discuss to what extent such slant path or horizontal path experiments can be representative of real GEO links.
- 13 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (26) , 47179-47198
Feasibility demonstration of AO pre-compensation for GEO feeder links in a relevant environment
Optical technologies are extremely competitive candidates to achieve very-high throughput links between ground and GEO satellites; however, their feasibility relies on the ability to mitigate channel impairments due to atmospheric turbulence. For that purpose, Adaptive Optics (AO) has already proved to be highly efficient on the downlink. However, for the uplink, anisoplanatism induced by point-ahead angle (PAA) compromises AO pre-compensation efficiency to an extent that depends on propagation conditions. The ability to properly assess the anisoplanatism impact in a wide variety of conditions is thus critical in designing the optical ground terminals. In this paper, we demonstrate the consistency of experimental coupled flux statistics with results coming from performance and end-to-end models, on an AO pre-compensated 13 km slant path in Tenerife. This validation is demonstrated in a wide variety of turbulence conditions, hence consolidating propagation channel models that are of critical importance for the reliability of future GEO feeder links. We then compare experimental results to theoretical on-sky performance, and discuss to what extent such slant path or horizontal path experiments can be representative of real GEO links.
- 29 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (31) , 9951-9956
Partial-field illumination ophthalmoscope: improving the contrast of a camera-based retinal imager
Effective and accurate in vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the partial-field illumination ophthalmoscope, a patterned illumination modality, integrated to a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide-field image. This new, to the best of our knowledge, modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
- 29 October 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (31) , 9951-9956
Partial-field illumination ophthalmoscope: improving the contrast of a camera-based retinal imager
Effective and accurate in vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the partial-field illumination ophthalmoscope, a patterned illumination modality, integrated to a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide-field image. This new, to the best of our knowledge, modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
- Open Access
Partial-Field Illumination Ophthalmoscope: improving the contrast of a camera-based retinal imager
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality, integrated on a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide field image. This new modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
Open AccessPartial-Field Illumination Ophthalmoscope: improving the contrast of a camera-based retinal imager
Effective and accurate in-vivo diagnosis of retinal pathologies requires high performance imaging devices, combining a large field of view and the ability to discriminate the ballistic signal from the diffuse background in order to provide a highly contrasted image of the retinal structures. Here, we have implemented the Partial-Field Illumination Ophthalmoscope, a patterned illumination modality, integrated on a high pixel rate adaptive optics full-field microscope. This non-invasive technique enables us to mitigate the low signal-to-noise ratio, intrinsic of full-field ophthalmoscopes, by partially illuminating the retina with complementary patterns to reconstruct a wide field image. This new modality provides an image contrast spanning from the full-field to the confocal contrast, depending on the pattern size. As a result, it offers various trade-offs in terms of contrast and acquisition speed, guiding the users towards the most efficient system for a particular clinical application.
- Open Access
Super-resolution in vivo retinal imaging using structured illumination ophthalmoscopy
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, scattering, sample-induced optical aberrations and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for a moving and thick tissue, we successfully applied SIM to in vivo retinal imaging and demonstrated structured illumination ophthalmoscopy for high contrast super-resolution in vivo imaging of the human retina.
Open AccessSuper-resolution in vivo retinal imaging using structured illumination ophthalmoscopy
Structured illumination microscopy (SIM) is one of the most versatile super-resolution techniques. Yet, its application to live imaging has been so far mainly limited to fluorescent and stationary specimens. Here, we present advancements in SIM to jointly tackle all the challenges of imaging living samples, i.e., obtaining super-resolution over an undistorted wide-field while dealing with sample motion, scattering, sample-induced optical aberrations and low signal-to-noise ratio. By using adaptive optics to compensate for optical aberrations and a reconstruction algorithm tailored for a moving and thick tissue, we successfully applied SIM to in vivo retinal imaging and demonstrated structured illumination ophthalmoscopy for high contrast super-resolution in vivo imaging of the human retina.