KDKevin L. Denis

Kevin L. Denis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kevin L. Denis has a total of 181 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Measurement of the Largest-scale CMB E-mode Polarization with CLASS

    by Yunyang云炀Li李, Joseph R. Eimer, John W. Appel, Charles L. Bennett, Michael K. Brewer, Sarah Marie Bruno, Ricardo Bustos, Carol Yan Yan Chan, David T. Chuss, Joseph Cleary, et al.

    We present measurements of large-scale cosmic microwave background E-mode polarization from the Cosmology Large Angular Scale Surveyor 90 GHz data. Using 115 det-yr of observations collected through 2024 with a variable-delay polarization modulator, we achieved a polarization sensitivity of 82 μ K arcmin , comparable to Planck at similar frequencies (100 and 143 GHz ). The analysis demonstrates effective mitigation of systematic errors and addresses challenges to large-angular-scale power recovery posed by time-domain filtering in maximum-likelihood map-making. A novel implementation of the pixel-space transfer matrix is introduced, which enables efficient filtering simulations and bias correction in the power spectrum using the quadratic cross-spectrum estimator. Overall, we achieved an unbiased time-domain filtering correction to recover the largest angular scale polarization, with the only power deficit, arising from map-making nonlinearity, being characterized as τ = 0.05 3 − 0.019 + 0.018 , marking the first ground-based attempt at such a measurement. At intermediate angular scales (ℓ > 30), our results, both independently and in cross-correlation with Planck, remain fully consistent with Planck’s measurements.


  • Open Access

    CLASS Angular Power Spectra and Map-component Analysis for 40 GHz Observations through 2022

    by Joseph R. Eimer, Yunyang云炀Li李, Michael K. Brewer, Rui瑞Shi时, Aamir Ali, John W. Appel, Charles L. Bennett, Sarah Marie Bruno, Ricardo Bustos, David T. Chuss, et al.

    Measurement of the largest angular scale (ℓ < 30) features of the cosmic microwave background (CMB) polarization is a powerful way to constrain the optical depth to reionization and search for the signature of inflation through the detection of primordial B-modes. We present an analysis of maps covering 73.6% of the sky made from the 40 GHz channel of the Cosmology Large Angular Scale Surveyor (CLASS) from 2016 August to 2022 May. Taking advantage of the measurement stability enabled by front-end polarization modulation and excellent conditions from the Atacama Desert, we show this channel achieves higher sensitivity than the analogous frequencies from satellite measurements in the range 10 < ℓ < 100. Simulations show the CLASS linear (circular) polarization maps have a white noise level of 125 ( 130 ) μ K arcmin . We measure the Galaxy-masked EE and BB spectra of diffuse synchrotron radiation and compare to space-based measurements at similar frequencies. In combination with external data, we expand measurements of the spatial variations of the synchrotron spectral energy density (SED) to include new sky regions and measure the diffuse SED in the harmonic domain. We place a new upper limit on a background of circular polarization in the range 5 < ℓ < 125 with the first bin showing D ℓ < 0.023 μ K CMB 2 at 95% confidence. These results establish a new standard for recovery of the largest-scale CMB polarization from the ground and signal exciting possibilities when the higher sensitivity and higher-frequency CLASS channels are included in the analysis.


  • Open Access

    CLASS Data Pipeline and Maps for 40 GHz Observations through 2022

    by Yunyang云炀Li李, Joseph R. Eimer, Keisuke Osumi, John W. Appel, Michael K. Brewer, Aamir Ali, Charles L. Bennett, Sarah Marie Bruno, Ricardo Bustos, David T. Chuss, et al.

    The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background over 75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. This paper describes the CLASS data pipeline and maps for 40 GHz observations conducted from 2016 August to 2022 May. We demonstrate how well the CLASS survey strategy, with rapid (∼10 Hz) front-end modulation, recovers the large-scale Galactic polarization signal from the ground: the mapping transfer function recovers ∼67% (85%) of EE and BB (VV) power at ℓ = 20 and ∼35% (47%) at ℓ = 10. We present linear and circular polarization maps over 75% of the sky. Simulations based on the data imply the maps have a white noise level of 110 μ K arcmin and correlated noise component rising at low-ℓ as ℓ −2.4. The transfer-function-corrected low-ℓ component is comparable to the white noise at the angular knee frequencies of ℓ ≈ 18 (linear polarization) and ℓ ≈ 12 (circular polarization). Finally, we present simulations of the level at which expected sources of systematic error bias the measurements, finding subpercent bias for the Λ cold dark matter EE power spectra. Bias from E-to-B leakage due to the data reduction pipeline and polarization angle uncertainty approaches the expected level for an r = 0.01 BB power spectrum. Improvements to the instrument calibration and the data pipeline will decrease this bias.


  • Open Access

    Observing Coronal Microscales and their Connection with Mesoscales

    by Douglas Rabin, Anne-Marie Novo-Gradac, Adrian Daw, James Klimchuk, Nicholeen Viall, Kevin Denis, Jeffrey Newmark, Steven Christe, Eliad Peretz, Farzad Kamalabadi, et al.

    Whitepaper #330 in the Decadal Survey for Solar and Space Physics (Heliophysics) 2024-2033. Main topics: basic research. Additional topics: ground-based missions/projects; solar physics; space-based missions/projects; system science.


  • On-Sky Performance of New 90 GHz Detectors for the Cosmology Large Angular Scale Surveyor (CLASS)

    by Carolina Núñez, John W. Appel, Michael K. Brewer, Sarah Marie Bruno, Rahul Datta, Charles L. Bennett, Ricardo Bustos, David T. Chuss, Sumit Dahal, Kevin L. Denis, et al.

    The Cosmology Large Angular Scale Surveyor (CLASS) is a polarization-sensitive telescope array located at an altitude of 5,200 m in the Chilean Atacama Desert and designed to measure the polarized Cosmic Microwave Background (CMB) over large angular scales. The CLASS array is currently observing with three telescopes covering four frequency bands: one at 40 GHz (Q); one at 90 GHz (W1); and one dichroic system at 150/220 GHz (HF). During the austral winter of 2022, we upgraded the first 90 GHz telescope (W1) by replacing four of the seven focal plane modules. These new modules contain detector wafers with an updated design, aimed at improving the optical efficiency and detector stability. We present a description of the design changes and measurements of on-sky optical efficiencies derived from observations of Jupiter.


  • Open Access

    Calibration of Transition-edge Sensor (TES) Bolometer Arrays with Application to CLASS

    by John W. Appel, Charles L. Bennett, Michael K. Brewer, Ricardo Bustos, Manwei Chan, David T. Chuss, Joseph Cleary, Jullianna D. Couto, Sumit Dahal, Rahul Datta, et al.

    The current and future cosmic microwave background (CMB) experiments fielding kilopixel arrays of transition-edge sensor (TES) bolometers require accurate and robust gain calibration methods. We simplify and refactor the standard TES model to directly relate the detector responsivity calibration and optical time constant to the measured TES current I and the applied bias current I b. The calibration method developed for the Cosmology Large Angular Scale Surveyor (CLASS) TES bolometer arrays relies on current versus voltage (I–V) measurements acquired daily prior to CMB observations. By binning Q-band (40 GHz) I–V measurements by optical loading, we find that the gain calibration median standard error within a bin is 0.3%. We test the accuracy of this I–V bin detector calibration method by using the Moon as a photometric standard. The ratio of measured Moon amplitudes between the detector pairs sharing the same feedhorn indicates a TES calibration error of 0.5%. We also find that, for the CLASS Q-band TES array, calibrating the response of individual detectors based solely on the applied TES bias current accurately corrects TES gain variations across time but introduces a bias in the TES calibration from data counts to power units. Since the TES current bias value is set and recorded before every observation, this calibration method can always be applied to the raw TES data and is not subject to I–V data quality or processing errors.


  • Open Access

    Origins Space Telescope Mission Concept Study Report

    by M. Meixner, A. Cooray, D. Leisawitz, J. Staguhn, L. Armus, C. Battersby, J. Bauer, E. Bergin, C. M. Bradford, K. Ennico-Smith, et al.

    The Origins Space Telescope (Origins) traces our cosmic history, from the formation of the first galaxies and the rise of metals to the development of habitable worlds and present-day life. Origins does this through exquisite sensitivity to infrared radiation from ions, atoms, molecules, dust, water vapor and ice, and observations of extra-solar planetary atmospheres, protoplanetary disks, and large-area extragalactic fields. Origins operates in the wavelength range 2.8 to 588 microns and is 1000 times more sensitive than its predecessors due to its large, cold (4.5 K) telescope and advanced instruments. Origins was one of four large missions studied by the community with support from NASA and industry in preparation for the 2020 Decadal Survey in Astrophysics. This is the final study report.


  • Open Access

    Fabrication of phononic filter structures for far-IR/sub-mm detector applications

    by Kevin L. Denis, Karwan Rostem, Marco A. Sagliocca, Elissa H. Williams, Edward J. Wollack

    A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19 W/Hz1/2 for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 {\mu}m) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one- and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

  • Open Access

    SiAl alloy feedhorn arrays: material properties, feedhorn design, and astrophysical applications

    by Aamir M. Ali, Thomas M. Essinger-Hileman, Tobias Marriage, Charles L. Bennett, Sumit Dahal, John W. Appel, Karwan Rostem, Edward J. Wollack, Kongpop U-Yen, Berhanu T. Bulcha, et al.

    We present here a study of the use of the SiAl alloy CE7 for the packaging of silicon devices at cryogenic temperatures. We report on the development of baseplates and feedhorn arrays for millimeter wave bolometric detectors for astrophysics. Existing interfaces to such detectors are typically made either of metals, which are easy to machine but mismatched to the thermal contraction profile of Si devices, or of silicon, which avoids the mismatch but is difficult to directly machine. CE7 exhibits properties of both Si and Al, which makes it uniquely well suited for this application. We measure CE7 to a) superconduct below a critical transition temperature, Tc, ~1.2 K, b) have a thermal contraction profile much closer to Si than metals, which enables simple mating, and c) have a low thermal conductivity which can be improved by Au-plating. Our investigations also demonstrate that CE7 can be machined well enough to fabricate small structures, such as #0-80 threaded holes, to tight tolerances (~25 μm) in contrast with pure silicon and similar substrates. We have fabricated CE7 baseplates being deployed in the 93 GHz polarimetric focal planes used in the Cosmology Large Angular Scale Surveyor (CLASS).1 We also report on the development of smooth-walled feedhorn arrays made of CE7 that will be used in a focal plane of dichroic 150/220 GHz detectors for the CLASS High-Frequency camera.


  • Open Access

    Superconducting Vacuum-Gap Crossovers for High Performance Microwave Applications

    by Kevin L. Denis, Ari D. Brown, Meng-Ping Chang, Ron Hu, Kongpop U-Yen, Edward Wollack

    The design and fabrication of low-loss wide-bandwidth superconducting vacuum-gap crossovers for high performance millimeter wave applications are described. In order to reduce ohmic and parasitic losses at millimeter wavelengths a vacuum gap is preferred relative to dielectric spacer. Here, vacuum-gap crossovers were realized by using a sacrificial polymer layer followed by niobium sputter deposition optimized for coating coverage over an underlying niobium signal layer. Both coplanar waveguide and microstrip crossover topologies have been explored in detail. The resulting fabrication process is compatible with a bulk micro-machining process for realizing waveguide coupled detectors, which includes sacrificial wax bonding, and wafer backside deep reactive ion etching for creation of leg isolated silicon membrane structures. Release of the vacuum gap structures along with the wax bonded wafer after DRIE is implemented in the same process step used to complete the detector fabrication