Ali Ghamari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ali Ghamari has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Vahid Broujerdian
School of Civil Engineering, Iran University of Science & Technology, Tehran, Iran
10 shared publications - Chanachai Thongchom
Department of Civil Engineering, Faculty of Engineering, Thammasat School of Engineering, Thammasat University, Pathumthani 12120, Thailand
6 shared publications - Denise-Penelope N. Kontoni
Department of Civil Engineering, School of Engineering, University of the Peloponnese, GR-26334 Patras, Greece
6 shared publications Chanachai Thongchom
Department of Civil Engineering, Faculty of Engineering, Thammasat School of Engineering Thammasat University Klong Nueng Pathumthani Thailand
3 shared publications- Farzad Hatami
Amirkabir University of Technology
3 shared publications Imran Karimi
3 shared publications
Latest Publications
- 15 October 2026
- Published by Springer Nature
- p. 273-282
An Innovative Modular Hybrid System Featuring Pultruded FRP Structural Profiles and Replaceable Ductile Steel Link Components
- 15 October 2026
- Published by Springer Nature
- p. 273-282
An Innovative Modular Hybrid System Featuring Pultruded FRP Structural Profiles and Replaceable Ductile Steel Link Components
- Open Access
Seismic Performance of a Novel GFRP Moment-Resisting Frame with Ductile Steel Links
Fiber-reinforced polymers (FRPs) offer many benefits, but their low ductility limits their use in primary components of moment-resisting frames (MRFs), where beam-end plastic hinging is expected. To overcome this drawback, this study introduced an innovative ductile MRF system composed of pultruded I-shaped FRP beams and columns, connected through ductile steel links that concentrate plastic deformations within the connections. This design is intended to concentrate ductility in the steel link while keeping the FRP members elastic, thereby improving energy dissipation. Using finite element modeling and parametric analyses, the influence of steel link geometry on system performance was investigated. Under the adopted modeling assumptions, the proposed hybrid system numerically exhibits stable hysteresis behavior without predicted loss of strength, stiffness, or energy dissipation, while all steel links meet AISC seismic compactness and design criteria. Although very short shear links (ρ ≤ 1) provide adequate performance, their susceptibility to damage makes short shear links (1.0 < ρ ≤ 1.6) the preferred choice. Reducing link length affects stiffness more significantly than ductility or strength. Finally, the necessary design equations for the proposed system are presented.
Open AccessSeismic Performance of a Novel GFRP Moment-Resisting Frame with Ductile Steel Links
Fiber-reinforced polymers (FRPs) offer many benefits, but their low ductility limits their use in primary components of moment-resisting frames (MRFs), where beam-end plastic hinging is expected. To overcome this drawback, this study introduced an innovative ductile MRF system composed of pultruded I-shaped FRP beams and columns, connected through ductile steel links that concentrate plastic deformations within the connections. This design is intended to concentrate ductility in the steel link while keeping the FRP members elastic, thereby improving energy dissipation. Using finite element modeling and parametric analyses, the influence of steel link geometry on system performance was investigated. Under the adopted modeling assumptions, the proposed hybrid system numerically exhibits stable hysteresis behavior without predicted loss of strength, stiffness, or energy dissipation, while all steel links meet AISC seismic compactness and design criteria. Although very short shear links (ρ ≤ 1) provide adequate performance, their susceptibility to damage makes short shear links (1.0 < ρ ≤ 1.6) the preferred choice. Reducing link length affects stiffness more significantly than ductility or strength. Finally, the necessary design equations for the proposed system are presented.
- 7 September 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-36
Towards resilient precast concrete frame featuring a hybrid system with replaceable ductile steel fuses
- 7 September 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-36
Towards resilient precast concrete frame featuring a hybrid system with replaceable ductile steel fuses
- Open Access
An Innovative Hybrid Moment-Resisting Frame System Using Pultruded GFRP Profiles and Replaceable Steel Link Equipped with Ductile Pipe Sections
Glass fiber-reinforced polymer (GFRP) is increasingly used in civil engineering because of its high strength-to-weight ratio, corrosion resistance, durability, and low maintenance requirements. However, its inherently brittle behavior and limited ductility restrict its application in seismic regions due to poor energy dissipation capacity. To address this limitation, this study proposes a novel hybrid system comprising pultruded GFRP profiles and a replaceable steel link with ductile pipe sections. The pipe element confines inelastic deformation to the steel components while keeping the GFRP members elastic. Numerical results demonstrate stable hysteretic behavior with no significant degradation in strength or stiffness, confirming the effectiveness of the proposed system. Also, increasing the ratio of the pipe thickness to the flange thickness of the steel link (β) ensures suitable performance provided that plastic hinge formation remains confined to the ductile pipe element and replaceable steel link. Adding the pipe element to the I-shaped steel link increases web stress when β ≤ 1.0 (leading to web yielding), while stresses in the flange, GFRP beam, and GFRP columns are reduced by 46–51%, 17–60%, and 15–40%, respectively. However, for β > 1.0, stresses in GFRP components are not reduced but slightly increase by 1–9% (negligible), making β > 1.0 not recommended. Also, by changing the to , , , and , the flexural capacity, stiffness, and energy dissipation are enhanced by 1.51 times to 2.46 times, 1.18 times to 1.38 times, and 1.35 times to 1.68 times, respectively. Finally, the necessary design equations for the proposed system are presented.Open AccessAn Innovative Hybrid Moment-Resisting Frame System Using Pultruded GFRP Profiles and Replaceable Steel Link Equipped with Ductile Pipe Sections
Glass fiber-reinforced polymer (GFRP) is increasingly used in civil engineering because of its high strength-to-weight ratio, corrosion resistance, durability, and low maintenance requirements. However, its inherently brittle behavior and limited ductility restrict its application in seismic regions due to poor energy dissipation capacity. To address this limitation, this study proposes a novel hybrid system comprising pultruded GFRP profiles and a replaceable steel link with ductile pipe sections. The pipe element confines inelastic deformation to the steel components while keeping the GFRP members elastic. Numerical results demonstrate stable hysteretic behavior with no significant degradation in strength or stiffness, confirming the effectiveness of the proposed system. Also, increasing the ratio of the pipe thickness to the flange thickness of the steel link (β) ensures suitable performance provided that plastic hinge formation remains confined to the ductile pipe element and replaceable steel link. Adding the pipe element to the I-shaped steel link increases web stress when β ≤ 1.0 (leading to web yielding), while stresses in the flange, GFRP beam, and GFRP columns are reduced by 46–51%, 17–60%, and 15–40%, respectively. However, for β > 1.0, stresses in GFRP components are not reduced but slightly increase by 1–9% (negligible), making β > 1.0 not recommended. Also, by changing the to , , , and , the flexural capacity, stiffness, and energy dissipation are enhanced by 1.51 times to 2.46 times, 1.18 times to 1.38 times, and 1.35 times to 1.68 times, respectively. Finally, the necessary design equations for the proposed system are presented. - Open Access
- 15 May 2026
- Published by Wiley in Engineering Reports
- Vol. 8 (5) , e70774
Utilizing Gusset Plates as Ductile Beam‐to‐Column Connections to Improve the Behavior of Steel Moment‐Resisting Frames
Steel moment-resisting frame (MRF) systems offer high ductility, allowing them to effectively absorb and dissipate seismic energy, enhancing earthquake resistance. Their flexibility in design accommodates architectural versatility and large open spaces, making them suitable for various building types. Since beams in this system carry gravity and seismic loading, replacing them is complicated after a severe earthquake. Therefore, in this paper, an innovative gusset plate connection, which acts as a rigid connection, was proposed and investigated parametrically and numerically. The proposed connection offers easier replacement, reduced welding, improved ductility than convectional MRF systems. Also, since it is expected that plastic hinge are formed through the gusset plate, beams remain elastic so they are designed for less forces than MRF system that was confirmed with numerical results. The performance of a gusset plate is affected by gusset plate geometry (thickness and dimensions). To enhance structural efficiency while optimizing strength, energy dissipation, and rigidity, it is highly advised to keep ratio of gusset plate thickness to web beam thickness greater than . This value supports improved resistance and energy absorption while preventing significant stiffness losses, fostering a durable and effective design. Also, overstrength of 1.8 was recommended for designing the element outside the gusset plate connection so that it provides a ductile fuse. Also, the required equations to design the system were proposed.- 15 May 2026
- Published by Wiley in Engineering Reports
- Vol. 8 (5) , e70774
Open AccessUtilizing Gusset Plates as Ductile Beam‐to‐Column Connections to Improve the Behavior of Steel Moment‐Resisting Frames
Steel moment-resisting frame (MRF) systems offer high ductility, allowing them to effectively absorb and dissipate seismic energy, enhancing earthquake resistance. Their flexibility in design accommodates architectural versatility and large open spaces, making them suitable for various building types. Since beams in this system carry gravity and seismic loading, replacing them is complicated after a severe earthquake. Therefore, in this paper, an innovative gusset plate connection, which acts as a rigid connection, was proposed and investigated parametrically and numerically. The proposed connection offers easier replacement, reduced welding, improved ductility than convectional MRF systems. Also, since it is expected that plastic hinge are formed through the gusset plate, beams remain elastic so they are designed for less forces than MRF system that was confirmed with numerical results. The performance of a gusset plate is affected by gusset plate geometry (thickness and dimensions). To enhance structural efficiency while optimizing strength, energy dissipation, and rigidity, it is highly advised to keep ratio of gusset plate thickness to web beam thickness greater than . This value supports improved resistance and energy absorption while preventing significant stiffness losses, fostering a durable and effective design. Also, overstrength of 1.8 was recommended for designing the element outside the gusset plate connection so that it provides a ductile fuse. Also, the required equations to design the system were proposed. - 10 April 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (2) , 144
Improving the behavior of RC beam-to-column connection using ultra high performance concrete jacket
- 10 April 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (2) , 144
Improving the behavior of RC beam-to-column connection using ultra high performance concrete jacket
- 5 March 2026
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 35 (3) , e70134
An Innovative Metallic Damper Directly Connected to CBF's Diagonal Member, a Comparative Experimental Study
- 5 March 2026
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 35 (3) , e70134
An Innovative Metallic Damper Directly Connected to CBF's Diagonal Member, a Comparative Experimental Study
- 26 February 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 24 (6) , 3991-4010
A novel ductile fuse for seismic-resilient precast concrete frames accounting simplified fabrication
- 26 February 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 24 (6) , 3991-4010
A novel ductile fuse for seismic-resilient precast concrete frames accounting simplified fabrication
- 5 September 2025
- Published by Elsevier in Structures
- Vol. 80
An innovative LYP-shear link as damper to improve the behavior of reinforced concrete frames
- 5 September 2025
- Published by Elsevier in Structures
- Vol. 80
An innovative LYP-shear link as damper to improve the behavior of reinforced concrete frames
- Open Access
- 30 May 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (6) , 280
Novel Ductile Moment-Resisting Frame Compound of Steel Gusset Plate for Beam-to-Column Connections and I-Shaped FRP Profile Sections
Moment-resisting frames (MRFs) are characterized by high energy dissipation capacity relying on plastic hinge formation at the two ends of beams. Despite their numerous advantages, Fiber-Reinforced Polymer (FRP) profile sections used in MRF systems suffer from low ductility, which remains a dilemma. FRP profiles have emerged as a novel and valuable material with significant advancement in structural engineering. In this paper, an MRF system composed of novel gusset plate steel connections (to provide ductility) and FRP profile sections for beams and columns is proposed and investigated numerically and parametrically. The results indicate that up to a rotation of 0.04 rad, the proposed gusset plate dissipates energy, whereas the beam and columns remain essentially elastic. Accordingly, with an increase in the ratio of vertical length to thickness of the gusset plate, energy dissipation is reduced. Through an increase in the ratio of horizontal length to thickness of the gusset plate from 63.5 to 127 and 254, the ultimate strength of the connection is reduced by 4% to 10% and 3% to 7%, respectively. It is suggested that gusset plate thickness be selected in such a way that its slenderness is not less than 47. Subsequently, the required equation is proposed to achieve the optimum performance of the system.
- 30 May 2025
- Published by MDPI AG in Journal of Composites Science
- Vol. 9 (6) , 280
Open AccessNovel Ductile Moment-Resisting Frame Compound of Steel Gusset Plate for Beam-to-Column Connections and I-Shaped FRP Profile Sections
Moment-resisting frames (MRFs) are characterized by high energy dissipation capacity relying on plastic hinge formation at the two ends of beams. Despite their numerous advantages, Fiber-Reinforced Polymer (FRP) profile sections used in MRF systems suffer from low ductility, which remains a dilemma. FRP profiles have emerged as a novel and valuable material with significant advancement in structural engineering. In this paper, an MRF system composed of novel gusset plate steel connections (to provide ductility) and FRP profile sections for beams and columns is proposed and investigated numerically and parametrically. The results indicate that up to a rotation of 0.04 rad, the proposed gusset plate dissipates energy, whereas the beam and columns remain essentially elastic. Accordingly, with an increase in the ratio of vertical length to thickness of the gusset plate, energy dissipation is reduced. Through an increase in the ratio of horizontal length to thickness of the gusset plate from 63.5 to 127 and 254, the ultimate strength of the connection is reduced by 4% to 10% and 3% to 7%, respectively. It is suggested that gusset plate thickness be selected in such a way that its slenderness is not less than 47. Subsequently, the required equation is proposed to achieve the optimum performance of the system.