Won-Yong Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Won-Yong Lee has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Han Nim Choi
Department of Chemistry, Yonsei University, Seoul, Republic of Korea
11 shared publicationsYoung‐Ku Lyu
Department of Chemistry and Center for Bioactive Molecular Hybrids, Yonsei University, Seoul 120-749, Korea
4 shared publicationsByung Kun Kim
Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
3 shared publicationsDaeho Jeong
Department of Chemistry Yonsei University Seoul 120-749, Republic of Korea
3 shared publicationsDong-Hwan Kim
Department of Chemistry, Yonsei University, Seoul 120-749, Republic of Korea
3 shared publicationsJee Hoon Han
Department of Chemistry and Center for Bioactive Molecular Hybrids, Yonsei University, Seoul 120-749, Korea
3 shared publications
Latest Publications
- 2 January 2025
- Published by Elsevier in Microchemical Journal
- Vol. 209
Enantioselective electrochemical L-phenylalanine sensor based on molecularly imprinted polymer embedded with redox probes
- 2 January 2025
- Published by Elsevier in Microchemical Journal
- Vol. 209
Enantioselective electrochemical L-phenylalanine sensor based on molecularly imprinted polymer embedded with redox probes
- Open Access
Quantitative Detection of Thitsiol and Urushiol as Markers from the Gluta usitata Lacquer Tree Using HPLC
Lacquer sap has been traditionally used in coatings and artwork. Suitable types of lacquer are required to preserve and restore artifacts. Recently, unsuitable cashew nut shell liquid (CNSL) has often been mixed with lacquer sap, so it is necessary to identify the characteristics of lacquer sap by the production area. However, research is still focused on urushiol and laccol. In this study, Myanmarese lacquer sap collected from Gluta usitata, which contains thitsiol as the main component, was analyzed by HPLC to quantify thitsiol using the standards 3-(10-phenyldecyl) benzene-1,2-diol (thitsiol 16) and 3-(8Z,11Z-pentadecadienyl)-benzenediol (urushiol 15:2) as markers, and calibration curves were plotted. The coefficients of determination (R2) for thitsiol 16 and urushiol 15:2 were 0.9985 and 0.9983, respectively. In addition, a blind test was conducted to confirm that accurate quantitative analysis was possible even when Myanmarese lacquer was mixed with lacquer from another production area, which contained urushiol as the main component, and CNSL, which contained cardol, a completely different catechol. Quantitative analysis of thitsiol 16 and urushiol 15:2 in Myanmarese lacquer using HPLC can be used to evaluate the quality of lacquer sap and for more sophisticated activities such as restoration by classifying differences in lacquer sap by the production area.
Open AccessQuantitative Detection of Thitsiol and Urushiol as Markers from the Gluta usitata Lacquer Tree Using HPLC
Lacquer sap has been traditionally used in coatings and artwork. Suitable types of lacquer are required to preserve and restore artifacts. Recently, unsuitable cashew nut shell liquid (CNSL) has often been mixed with lacquer sap, so it is necessary to identify the characteristics of lacquer sap by the production area. However, research is still focused on urushiol and laccol. In this study, Myanmarese lacquer sap collected from Gluta usitata, which contains thitsiol as the main component, was analyzed by HPLC to quantify thitsiol using the standards 3-(10-phenyldecyl) benzene-1,2-diol (thitsiol 16) and 3-(8Z,11Z-pentadecadienyl)-benzenediol (urushiol 15:2) as markers, and calibration curves were plotted. The coefficients of determination (R2) for thitsiol 16 and urushiol 15:2 were 0.9985 and 0.9983, respectively. In addition, a blind test was conducted to confirm that accurate quantitative analysis was possible even when Myanmarese lacquer was mixed with lacquer from another production area, which contained urushiol as the main component, and CNSL, which contained cardol, a completely different catechol. Quantitative analysis of thitsiol 16 and urushiol 15:2 in Myanmarese lacquer using HPLC can be used to evaluate the quality of lacquer sap and for more sophisticated activities such as restoration by classifying differences in lacquer sap by the production area.
- Open Access
One-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
A highly sensitive tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor based on a graphene-titania-Nafion composite film has been prepared in a simple one-step manner. In the present work, a highly concentrated 0.1 M Ru(bpy)32+ solution was mixed with an as-prepared graphene-titania-Nafion composite solution (1:20, v/v), and then a small aliquot (2 µL) of the resulting mixture solution was cast on a glassy carbon electrode surface. This one-step process for the construction of an ECL sensor shortens the fabrication time and leads to reproducible ECL signals. Due to the synergistic effect of conductive graphene and mesoporous sol-gel derived titania-Nafion composite, the present ECL sensor leads to a highly sensitive detection of tripropylamine from 1.0 × 10−8 M to 2.0 × 10−3 M with a detection limit of 0.8 nM (S/N = 3), which is lower in comparison to that of the ECL sensor based on the corresponding ECL sensor based on the titania-Nafion composite containing carbon nanotube. The present ECL sensor also shows a good response for nicotinamide adenine dinucleotide hydrogen (NADH) from 1.0 × 10−6 M to 1.0 × 10−3 M with a detection limit of 0.4 µM (S/N = 3). Thus, the present ECL sensor can offer potential benefits in the development of dehydrogenase-based biosensors.
Open AccessOne-Step Fabrication of Highly Sensitive Tris(2,2′-bipyridyl)ruthenium(II) Electrogenerated Chemiluminescence Sensor Based on Graphene-Titania-Nafion Composite Film
A highly sensitive tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) electrogenerated chemiluminescence (ECL) sensor based on a graphene-titania-Nafion composite film has been prepared in a simple one-step manner. In the present work, a highly concentrated 0.1 M Ru(bpy)32+ solution was mixed with an as-prepared graphene-titania-Nafion composite solution (1:20, v/v), and then a small aliquot (2 µL) of the resulting mixture solution was cast on a glassy carbon electrode surface. This one-step process for the construction of an ECL sensor shortens the fabrication time and leads to reproducible ECL signals. Due to the synergistic effect of conductive graphene and mesoporous sol-gel derived titania-Nafion composite, the present ECL sensor leads to a highly sensitive detection of tripropylamine from 1.0 × 10−8 M to 2.0 × 10−3 M with a detection limit of 0.8 nM (S/N = 3), which is lower in comparison to that of the ECL sensor based on the corresponding ECL sensor based on the titania-Nafion composite containing carbon nanotube. The present ECL sensor also shows a good response for nicotinamide adenine dinucleotide hydrogen (NADH) from 1.0 × 10−6 M to 1.0 × 10−3 M with a detection limit of 0.4 µM (S/N = 3). Thus, the present ECL sensor can offer potential benefits in the development of dehydrogenase-based biosensors.
- 3 September 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (4) , 629-639
A Highly Sensitive Amperometric Galactose Biosensor Based on Graphene‐doped Sol‐gel‐derived Titania‐Nafion Composite Films
A highly sensitive amperometric galactose biosensor was developed by encapsulating galactose oxidase within the graphene‐doped sol‐gel titania‐Nafion composite film on platinized glassy carbon electrode. Due to the combined electrocatalytic activity of graphene and Pt NPs on the electrode towards hydrogen peroxide as well as the mesoporous nature of the titania‐Nafion composite, the present galactose biosensor exhibited relatively fast response time under 2 s, high sensitivity of 40.6 mAM−1cm−2, and wide dynamic range over three orders of magnitude with a detection limit of 3.78×10−6 M (S/N=3). In addition, the biocompatible composite in the biosensor secures excellent long‐term stability.
- 3 September 2021
- Published by Wiley in Electroanalysis
- Vol. 34 (4) , 629-639
A Highly Sensitive Amperometric Galactose Biosensor Based on Graphene‐doped Sol‐gel‐derived Titania‐Nafion Composite Films
A highly sensitive amperometric galactose biosensor was developed by encapsulating galactose oxidase within the graphene‐doped sol‐gel titania‐Nafion composite film on platinized glassy carbon electrode. Due to the combined electrocatalytic activity of graphene and Pt NPs on the electrode towards hydrogen peroxide as well as the mesoporous nature of the titania‐Nafion composite, the present galactose biosensor exhibited relatively fast response time under 2 s, high sensitivity of 40.6 mAM−1cm−2, and wide dynamic range over three orders of magnitude with a detection limit of 3.78×10−6 M (S/N=3). In addition, the biocompatible composite in the biosensor secures excellent long‐term stability.
- 4 June 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (13) , 2114-2127
Highly Sensitive Determination of Concanavalin A Lectin Based on Silver-Enhanced Electrogenerated Chemiluminescence of Luminol
A highly sensitive bioassay based on silver-enhanced luminol electrogenerated chemiluminescence (ECL) is reported for the determination of concanavalin A lectin. A gold electrode modified with the mixed self-assembled monolayer of thiolated mannoside and mercaptohexanol was used to selectively capture a target lectin, concanavalin A, through the specific interaction between mannoside and concanavalin A. Mannoside-functionalized gold nanoparticles were further introduced to the opposite binding sites of the tetrameric concanavalin A to form a sandwich-type complex. Silver enhancement step was performed to coat the surface of mannose-stabilized gold nanoparticles with silver. The deposited silver was dissolved in an acidic solution and further neutralized. The resulting silver ions were finally detected with luminol electrogenerated chemiluminescence, in which the silver ions greatly enhanced the chemiluminescence intensity. The present electrogenerated chemiluminescence bioassay detected concanavalin A from 0.190 to 10.0 µg/mL (r2 = 0.999) with a detection limit of 0.146 µg/mL (signal to noise ratio = 3), which is much lower compared to previously reported methods such as microgravimetry, surface plasmon resonance, and colorimetry. Furthermore, the present bioassay showed good selectivity over possible interfering lectin proteins.
- 4 June 2018
- Published by Taylor & Francis in Analytical Letters
- Vol. 51 (13) , 2114-2127
Highly Sensitive Determination of Concanavalin A Lectin Based on Silver-Enhanced Electrogenerated Chemiluminescence of Luminol
A highly sensitive bioassay based on silver-enhanced luminol electrogenerated chemiluminescence (ECL) is reported for the determination of concanavalin A lectin. A gold electrode modified with the mixed self-assembled monolayer of thiolated mannoside and mercaptohexanol was used to selectively capture a target lectin, concanavalin A, through the specific interaction between mannoside and concanavalin A. Mannoside-functionalized gold nanoparticles were further introduced to the opposite binding sites of the tetrameric concanavalin A to form a sandwich-type complex. Silver enhancement step was performed to coat the surface of mannose-stabilized gold nanoparticles with silver. The deposited silver was dissolved in an acidic solution and further neutralized. The resulting silver ions were finally detected with luminol electrogenerated chemiluminescence, in which the silver ions greatly enhanced the chemiluminescence intensity. The present electrogenerated chemiluminescence bioassay detected concanavalin A from 0.190 to 10.0 µg/mL (r2 = 0.999) with a detection limit of 0.146 µg/mL (signal to noise ratio = 3), which is much lower compared to previously reported methods such as microgravimetry, surface plasmon resonance, and colorimetry. Furthermore, the present bioassay showed good selectivity over possible interfering lectin proteins.
- Open Access
- 10 October 2016
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2016, 1-6
Sensing Estrogen with Electrochemical Impedance Spectroscopy
This study demonstrates the application feasibility of electrochemical impedance spectroscopy (EIS) in measuring estrogen (17β-estradiol) in gas phase. The present biosensor gives a linear response () for 17β-estradiol vapor concentration from 3.7 ng/L to 3.7 × 10−4 ng/L with a limit of detection (3.7 × 10−4 ng/L). The results show that the fabricated biosensor demonstrates better detection limit of 17β-estradiol in gas phase than the previous report with GC-MS method. This estrogen biosensor has many potential applications for on-site detection of a variety of endocrine disrupting compounds (EDCs) in the gas phase.- 10 October 2016
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2016, 1-6
Open AccessSensing Estrogen with Electrochemical Impedance Spectroscopy
This study demonstrates the application feasibility of electrochemical impedance spectroscopy (EIS) in measuring estrogen (17β-estradiol) in gas phase. The present biosensor gives a linear response () for 17β-estradiol vapor concentration from 3.7 ng/L to 3.7 × 10−4 ng/L with a limit of detection (3.7 × 10−4 ng/L). The results show that the fabricated biosensor demonstrates better detection limit of 17β-estradiol in gas phase than the previous report with GC-MS method. This estrogen biosensor has many potential applications for on-site detection of a variety of endocrine disrupting compounds (EDCs) in the gas phase. - 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (13) , 2018-2030
Electrochemical Determination of Bisphenol A by Single-Walled Carbon Nanotube Composite Glassy Carbon Electrode
A mesoporous composite of single-walled carbon nanotube-doped ionic liquid/sol–gel titania/Nafion has been used for the fabrication of a highly sensitive electrochemical sensor for bisphenol A. Four ionic liquids with varying hydrophobicity, 1-butyl-3-methylimidazolium, 1-ethyl-3-methylimidazolium, 1,3-dimethoxy-2-methylimidazolium, and 1-benzyl-3-methylimidazolium hexafluorophosphates, were incorporated into the composite films. Although the composite-modified electrode with 1-butyl-3-methylimidazolium hexafluorophosphate exhibited the largest voltammetric response, the incorporation of ionic liquids, regardless of the type, into the composite-modified electrodes increased the electron transfer ability of the composite due to the high conductivity of ionic liquids and accumulated bisphenol A on the electrode surface due to π–π interactions between aromatic rings of bisphenol A and imidazole groups of the ionic liquids. Therefore, the combination of ionic liquid and electrocatalytically active single-walled carbon nanotube in the composite film provided excellent analytical performance compared to other electrochemical sensors for bisphenol A. Under the optimized conditions, the electrochemical sensor provided a linear response to bisphenol A from 1.0 × 10−9 to 1.0 × 10−5 M with a detection limit of 5.0 × 10−10 M. The sensor was selective to the analyte and also exhibited good reproducibility, with a relative standard deviation of 3.5%.
- 18 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (13) , 2018-2030
Electrochemical Determination of Bisphenol A by Single-Walled Carbon Nanotube Composite Glassy Carbon Electrode
A mesoporous composite of single-walled carbon nanotube-doped ionic liquid/sol–gel titania/Nafion has been used for the fabrication of a highly sensitive electrochemical sensor for bisphenol A. Four ionic liquids with varying hydrophobicity, 1-butyl-3-methylimidazolium, 1-ethyl-3-methylimidazolium, 1,3-dimethoxy-2-methylimidazolium, and 1-benzyl-3-methylimidazolium hexafluorophosphates, were incorporated into the composite films. Although the composite-modified electrode with 1-butyl-3-methylimidazolium hexafluorophosphate exhibited the largest voltammetric response, the incorporation of ionic liquids, regardless of the type, into the composite-modified electrodes increased the electron transfer ability of the composite due to the high conductivity of ionic liquids and accumulated bisphenol A on the electrode surface due to π–π interactions between aromatic rings of bisphenol A and imidazole groups of the ionic liquids. Therefore, the combination of ionic liquid and electrocatalytically active single-walled carbon nanotube in the composite film provided excellent analytical performance compared to other electrochemical sensors for bisphenol A. Under the optimized conditions, the electrochemical sensor provided a linear response to bisphenol A from 1.0 × 10−9 to 1.0 × 10−5 M with a detection limit of 5.0 × 10−10 M. The sensor was selective to the analyte and also exhibited good reproducibility, with a relative standard deviation of 3.5%.
- 20 April 2013
- Published by Korean Chemical Society in Bulletin of the Korean Chemical Society
- Vol. 34 (4) , 1065-1069
Electrochemical Determination of Bisphenol A at Carbon Nanotube-Doped Titania-Nafion Composite Modified Electrode
- 20 April 2013
- Published by Korean Chemical Society in Bulletin of the Korean Chemical Society
- Vol. 34 (4) , 1065-1069
Electrochemical Determination of Bisphenol A at Carbon Nanotube-Doped Titania-Nafion Composite Modified Electrode
- 14 November 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (1) , 64-67
Detection of concanavalin A based on attenuated fluorescence resonance energy transfer between quantum dots and mannose-stabilized gold nanoparticles
Highly sensitive biosensing of concanavalin A (Con A) has been developed based on the attenuation of FRET efficiency between amine-terminated quantum dots and mannose-stabilized Au nanoparticles in the presence of Con A, which inhibits the H-bonding formation of the QDs–AuNPs assembly, thereby causing the fluorescence recovery.
- 14 November 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (1) , 64-67
Detection of concanavalin A based on attenuated fluorescence resonance energy transfer between quantum dots and mannose-stabilized gold nanoparticles
Highly sensitive biosensing of concanavalin A (Con A) has been developed based on the attenuation of FRET efficiency between amine-terminated quantum dots and mannose-stabilized Au nanoparticles in the presence of Con A, which inhibits the H-bonding formation of the QDs–AuNPs assembly, thereby causing the fluorescence recovery.