Vikas Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vikas Gupta has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Akash Saxena
Central University of Haryana
9 shared publications - Bhanu Pratap Soni
Fiji National University
9 shared publications Pradeep Anjana
Dept. of Electrical Engg., MNIT Jaipur, India
6 shared publicationsHarpal Tiwari
Dept. of Electrical Engg., MNIT Jaipur, India
4 shared publications- Nitin Gupta
MNIT
4 shared publications - Ajay Kumar
Punjab Engineering College
3 shared publications
Latest Publications
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5510-5521
Distribution Locational Marginal Price Driven Reactive Demand Response from Electric Vehicle Aggregator
To maintain balance in renewable energy-rich grids, distribution system operators (DSOs) increasingly rely on local demand response (DR) flexibility. Electric vehicles (EVs) through an EV aggregator (EVA) can serve as a cost-effective source for DR flexibility. While EVs' active DR capabilities have received attention, their potential for providing reactive DR to support the grid remains underexplored. This study explores the potential of EVAs as active as well as reactive DR provider to DSO, enhancing the synergy across transmission-distribution (TD) interface. Spectral clustering algorithm-based aggregation is performed to obtain aggregated DR. The aggregated active & reactive DR potential is considered for hierarchical energy management framework, where DSO optimizes grid's operational cost under network constraints while considering DR from EVA, and EVA minimizes its energy payments driven by DSO's Distribution Locational Marginal Prices (DLMPs). The resulting bi-level model is transformed into a single-level optimization problem using KKT optimality conditions and strong duality theorem. Furthermore, the EVA decomposes the reference schedule provided by DSO to meet user constraints. A case study of the IEEE 33-bus radial distribution system demonstrates that reactive DR through EVA at the distribution level can significantly enhance economic and physical systems performance while maintaining balance at TD interface.
- 24 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5510-5521
Distribution Locational Marginal Price Driven Reactive Demand Response from Electric Vehicle Aggregator
To maintain balance in renewable energy-rich grids, distribution system operators (DSOs) increasingly rely on local demand response (DR) flexibility. Electric vehicles (EVs) through an EV aggregator (EVA) can serve as a cost-effective source for DR flexibility. While EVs' active DR capabilities have received attention, their potential for providing reactive DR to support the grid remains underexplored. This study explores the potential of EVAs as active as well as reactive DR provider to DSO, enhancing the synergy across transmission-distribution (TD) interface. Spectral clustering algorithm-based aggregation is performed to obtain aggregated DR. The aggregated active & reactive DR potential is considered for hierarchical energy management framework, where DSO optimizes grid's operational cost under network constraints while considering DR from EVA, and EVA minimizes its energy payments driven by DSO's Distribution Locational Marginal Prices (DLMPs). The resulting bi-level model is transformed into a single-level optimization problem using KKT optimality conditions and strong duality theorem. Furthermore, the EVA decomposes the reference schedule provided by DSO to meet user constraints. A case study of the IEEE 33-bus radial distribution system demonstrates that reactive DR through EVA at the distribution level can significantly enhance economic and physical systems performance while maintaining balance at TD interface.
- 5 July 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (2)
Active power coefficient control for grid-tied photovoltaic system under voltage distortions
Grid-integrated solar photovoltaic (GSPV) system requires a simpler and computationally less intensive control algorithm for continuous maneuver of real power inoculation and power quality enhancement underneath diverse operating conditions. In order to reduce the computational burden, this article presents an active power coefficient (APC)-based control strategy for extracting the fundamental weight factor. The proposed structure utilizes only three mathematical operators for weight extraction, and thereby reduces the computational burden. Therefore, only 35 µs sampling time is required to implement the proposed control through low-cost ARM cortex M4-based microcontroller. As a result, the proposed control provides following advantages: 1) faster response 2) lesser current distortions, 3) lesser DC-link oscillations, and 4) lower implementation cost. Moreover, the improved linear time invariant-enhanced phase look loop (LTI-EPLL) structure is also proposed for synchronization of GSPV system. This structure accurately trails the phase angle and frequency of voltage signals despite the presence of DC component and harmonics. Besides, the amplitude estimation loop removes the dependency of supply magnitude from unit template. Further, the proposed APC algorithm and synchronizing control is designed in waijung environment of MATLAB/Simulink for testing various operating conditions. Finally, the total harmonic distortion of source current is remarkably decreased to 1.67%, which is well within the limits of IEEE 519 standard.
- 5 July 2020
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 47 (2)
Active power coefficient control for grid-tied photovoltaic system under voltage distortions
Grid-integrated solar photovoltaic (GSPV) system requires a simpler and computationally less intensive control algorithm for continuous maneuver of real power inoculation and power quality enhancement underneath diverse operating conditions. In order to reduce the computational burden, this article presents an active power coefficient (APC)-based control strategy for extracting the fundamental weight factor. The proposed structure utilizes only three mathematical operators for weight extraction, and thereby reduces the computational burden. Therefore, only 35 µs sampling time is required to implement the proposed control through low-cost ARM cortex M4-based microcontroller. As a result, the proposed control provides following advantages: 1) faster response 2) lesser current distortions, 3) lesser DC-link oscillations, and 4) lower implementation cost. Moreover, the improved linear time invariant-enhanced phase look loop (LTI-EPLL) structure is also proposed for synchronization of GSPV system. This structure accurately trails the phase angle and frequency of voltage signals despite the presence of DC component and harmonics. Besides, the amplitude estimation loop removes the dependency of supply magnitude from unit template. Further, the proposed APC algorithm and synchronizing control is designed in waijung environment of MATLAB/Simulink for testing various operating conditions. Finally, the total harmonic distortion of source current is remarkably decreased to 1.67%, which is well within the limits of IEEE 519 standard.
- 28 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 7628-7641
A Novel Orthogonal Current Decomposition Control for Grid-Connected Voltage Source Converter
Grid connected voltage source converter (VSC) is used to control the flow of active power from renewable energy sources with several functionalities such as harmonic mitigation, reactive power compensation and power factor improvement etc. The reference current calculation and its accuracy decide the performance of the control algorithms during harmonic disturbances. Fundamental signal extraction techniques are utilized to overcome the disturbances present in the system voltage and current. This paper presents a novel orthogonal current decomposition control (OCDC) for load current decomposition into active and reactive components. These current components are obtained through character of orthogonal vector in the inner product space. The block diagram of proposed technique is implemented with the help of adder, multiplier, and windowed integrator. Phase voltage and load current for each phase are used as inputs to this functional diagram for getting desired fundamental active current signal. Subsequently, adjustable DC-link voltage control is also presented to diminish the switching losses in the converter and to avoid the false tripping of grid connected system during susceptible grid conditions. The proposed control technique is simulated in MATLAB®/SIMULINK and verified through developed hardware prototype using ARM Cortex M4 based microcontroller (STM32F407VGT6) using waijung environment.
- 28 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (6) , 7628-7641
A Novel Orthogonal Current Decomposition Control for Grid-Connected Voltage Source Converter
Grid connected voltage source converter (VSC) is used to control the flow of active power from renewable energy sources with several functionalities such as harmonic mitigation, reactive power compensation and power factor improvement etc. The reference current calculation and its accuracy decide the performance of the control algorithms during harmonic disturbances. Fundamental signal extraction techniques are utilized to overcome the disturbances present in the system voltage and current. This paper presents a novel orthogonal current decomposition control (OCDC) for load current decomposition into active and reactive components. These current components are obtained through character of orthogonal vector in the inner product space. The block diagram of proposed technique is implemented with the help of adder, multiplier, and windowed integrator. Phase voltage and load current for each phase are used as inputs to this functional diagram for getting desired fundamental active current signal. Subsequently, adjustable DC-link voltage control is also presented to diminish the switching losses in the converter and to avoid the false tripping of grid connected system during susceptible grid conditions. The proposed control technique is simulated in MATLAB®/SIMULINK and verified through developed hardware prototype using ARM Cortex M4 based microcontroller (STM32F407VGT6) using waijung environment.
- 1 August 2018
- Published by Elsevier in Applied Soft Computing
- Vol. 69, 1-13
Intelligent Grey Wolf Optimizer – Development and application for strategic bidding in uniform price spot energy market
- 1 August 2018
- Published by Elsevier in Applied Soft Computing
- Vol. 69, 1-13
Intelligent Grey Wolf Optimizer – Development and application for strategic bidding in uniform price spot energy market
- Open Access
- 10 May 2018
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2018, 1-12
Assessment of Transient Stability through Coherent Machine Identification by Using Least-Square Support Vector Machine
Transient stability assessment (TSA) of the power system is a crucial issue with escalating demands and large operational constraints. Real-time TSA allows for deciding and monitoring of the relevant preventive/corrective control actions depending on the dynamic behavior of the system components. To assess this, coherency of generating machines is to be found. After determination of the coherent machines, any corrective or preventive action can be initiated by the system operator to maintain stability of the system during occurrence of any severe contingency. The Transient Severity Index (TSI) introduced in this paper has proven to be an interesting alternative for determining generator coherency. Furthermore, the numerical values of this index are employed to construct a supervised learning-based classifier and the ranking method with the help of system load and generation as input features. This framework employs the support vector machine (SVM) to perform the ranking of the generators based on severity and classify them into vulnerable and nonvulnerable machines. The results are validated on the IEEE 10-generator, 39-bus test (New England) system. It is observed that the proposed index and the supervised learning engine give satisfactory results and both are aligned with the published approaches.
- 10 May 2018
- Published by Wiley in Modelling and Simulation in Engineering
- Vol. 2018, 1-12
Open AccessAssessment of Transient Stability through Coherent Machine Identification by Using Least-Square Support Vector Machine
Transient stability assessment (TSA) of the power system is a crucial issue with escalating demands and large operational constraints. Real-time TSA allows for deciding and monitoring of the relevant preventive/corrective control actions depending on the dynamic behavior of the system components. To assess this, coherency of generating machines is to be found. After determination of the coherent machines, any corrective or preventive action can be initiated by the system operator to maintain stability of the system during occurrence of any severe contingency. The Transient Severity Index (TSI) introduced in this paper has proven to be an interesting alternative for determining generator coherency. Furthermore, the numerical values of this index are employed to construct a supervised learning-based classifier and the ranking method with the help of system load and generation as input features. This framework employs the support vector machine (SVM) to perform the ranking of the generators based on severity and classify them into vulnerable and nonvulnerable machines. The results are validated on the IEEE 10-generator, 39-bus test (New England) system. It is observed that the proposed index and the supervised learning engine give satisfactory results and both are aligned with the published approaches.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modified P-Q technique to mitigate power quality problems in distribution system
The use of nonlinear loads and power electronics switches are increasing day by day and causing so many problems like, harmonics pollution, reactive power demand, low power factor etc. These problems are mitigated through Shunt Active Power Filter (SAPF) but the system robustness is depending on the control algorithm. In this article the Modified P-Q theory is implemented to mitigate power quality problems in distribution system and the results are compared with the existing SRF theory to prove the robustness of the controller. The designed active power filter compensates reactive power, current harmonic from distribution system with maintaining power factor near to unity and also reduces the burden of neutral conductor effectively with balanced source current through Modified P-Q theory over SRF theory.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Modified P-Q technique to mitigate power quality problems in distribution system
The use of nonlinear loads and power electronics switches are increasing day by day and causing so many problems like, harmonics pollution, reactive power demand, low power factor etc. These problems are mitigated through Shunt Active Power Filter (SAPF) but the system robustness is depending on the control algorithm. In this article the Modified P-Q theory is implemented to mitigate power quality problems in distribution system and the results are compared with the existing SRF theory to prove the robustness of the controller. The designed active power filter compensates reactive power, current harmonic from distribution system with maintaining power factor near to unity and also reduces the burden of neutral conductor effectively with balanced source current through Modified P-Q theory over SRF theory.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Reduce day-time domestic energy demand by synchronization of PV with shunt APF
The pressure on the utilities to drive a greater extent of their power from renewable energy is increasing globally. The increase in load is also compelling the utilities to include Renewable Energy Sources (RES) into the system. With the increasing threats to the environment from the energy production by the extensive use of fossil fuels has left us with the consideration of RES as the only possible solution. The paper present a novel DQ control strategy to synchronize day-time domestic PV based shunt APF compensator to reduce the grid dependency during day time. The system also compensates reactive power and current harmonic from distribution system with maintaining power factor near to unity.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Reduce day-time domestic energy demand by synchronization of PV with shunt APF
The pressure on the utilities to drive a greater extent of their power from renewable energy is increasing globally. The increase in load is also compelling the utilities to include Renewable Energy Sources (RES) into the system. With the increasing threats to the environment from the energy production by the extensive use of fossil fuels has left us with the consideration of RES as the only possible solution. The paper present a novel DQ control strategy to synchronize day-time domestic PV based shunt APF compensator to reduce the grid dependency during day time. The system also compensates reactive power and current harmonic from distribution system with maintaining power factor near to unity.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of different Controllers on two area interconnected power system model using Gravitational Search Algorithm
This paper presents the effect of different controllers on Load Frequency Control (LFC) of a two area interconnected thermal power system for the advancement of dynamic performance. Time domain simulations are performed to investigate the performance of the system in the presence of generation rate constraint (GRC). The Controller consists of I, PI and PID compensator where the gain setting of proportional (P), integral (I) and derivative (D) constants are optimizes using Gravitational Search Algorithm (GSA) and the objective function used for minimization is Integral of Time multiplied with Absolute value of Error (ITAE). Results reveal that for a step load disturbance, PID controller gives the better dynamic performance of LFC on I and PI compensator and keep the frequency and tie-line power within the range; hence, it proves the effectiveness of GSA based PID compensator in two area interconnected thermal system.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of different Controllers on two area interconnected power system model using Gravitational Search Algorithm
This paper presents the effect of different controllers on Load Frequency Control (LFC) of a two area interconnected thermal power system for the advancement of dynamic performance. Time domain simulations are performed to investigate the performance of the system in the presence of generation rate constraint (GRC). The Controller consists of I, PI and PID compensator where the gain setting of proportional (P), integral (I) and derivative (D) constants are optimizes using Gravitational Search Algorithm (GSA) and the objective function used for minimization is Integral of Time multiplied with Absolute value of Error (ITAE). Results reveal that for a step load disturbance, PID controller gives the better dynamic performance of LFC on I and PI compensator and keep the frequency and tie-line power within the range; hence, it proves the effectiveness of GSA based PID compensator in two area interconnected thermal system.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A novel dynamic evolution algorithm to mitigate transient in large load variations
This paper presents, a controller based on dynamic evolution technique to control the three phase power inverter's output for large load changes. Proposed controller methodology is analysis and is tested on three phase inverter in MATLAB/Simulink for star and delta load with balanced and unbalanced combination. This system is also tested for lagging and leading nature of load by connecting an inductor and a capacitor in load branch. In complete operation DEC recover approximate hundred times load variation within 1ms and gives good performance against initial transients. Output power quality is good and within limit compare to IEEE 519 harmonics standard.
- 1 July 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A novel dynamic evolution algorithm to mitigate transient in large load variations
This paper presents, a controller based on dynamic evolution technique to control the three phase power inverter's output for large load changes. Proposed controller methodology is analysis and is tested on three phase inverter in MATLAB/Simulink for star and delta load with balanced and unbalanced combination. This system is also tested for lagging and leading nature of load by connecting an inductor and a capacitor in load branch. In complete operation DEC recover approximate hundred times load variation within 1ms and gives good performance against initial transients. Output power quality is good and within limit compare to IEEE 519 harmonics standard.
- 21 June 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (13) , 1530-1542
Hardware Implementation of Shunt APF Using Modified Fuzzy Control Algorithm with STM32F407VGT Microcontroller
This article presents a modified fuzzy controller (MFC) to generate a reference signal for the control algorithm to drive the shunt active power filter (SAPF) for improving the power quality of a microgrid at the distribution end. The proposed MFC, based on the alive-and-kicking behavior of the system, is used to regulate the DC-link voltage of the SAPF. The MFC is implemented through the general dynamic behavior of a process with introducing the new rules set. It is compared with the PI controller for evaluation of optimal steady-state, dynamic, and transient performance of SAPF, namely the reactive power and DC voltage control. The effectiveness of the proposed controller is tested on non-linear loads using a hardware prototype. The STM32F407VGT (ARM Ltd., San Jose, California, USA) processor is used to interface algorithm with the hardware setup. The results of the proposed controller scheme are promising and are compared with MATLAB (The MathWorks, Natick, Massachusetts, USA) simulation results. The system is capable for minimizing current harmonics, reactive power and improving the power factor. Also, the advantage of the STM32F407VGT over the Digital Signal Processor (Texas Instruments, USA) is introduced. The performance of the proposed controller is better in comparison with conventional controller.
- 21 June 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (13) , 1530-1542
Hardware Implementation of Shunt APF Using Modified Fuzzy Control Algorithm with STM32F407VGT Microcontroller
This article presents a modified fuzzy controller (MFC) to generate a reference signal for the control algorithm to drive the shunt active power filter (SAPF) for improving the power quality of a microgrid at the distribution end. The proposed MFC, based on the alive-and-kicking behavior of the system, is used to regulate the DC-link voltage of the SAPF. The MFC is implemented through the general dynamic behavior of a process with introducing the new rules set. It is compared with the PI controller for evaluation of optimal steady-state, dynamic, and transient performance of SAPF, namely the reactive power and DC voltage control. The effectiveness of the proposed controller is tested on non-linear loads using a hardware prototype. The STM32F407VGT (ARM Ltd., San Jose, California, USA) processor is used to interface algorithm with the hardware setup. The results of the proposed controller scheme are promising and are compared with MATLAB (The MathWorks, Natick, Massachusetts, USA) simulation results. The system is capable for minimizing current harmonics, reactive power and improving the power factor. Also, the advantage of the STM32F407VGT over the Digital Signal Processor (Texas Instruments, USA) is introduced. The performance of the proposed controller is better in comparison with conventional controller.