CMCarlos Milovic

Carlos Milovic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlos Milovic has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigating the effect of masking and background field removal algorithms on the quality of QSM reconstructions using a realistic numerical head phantom

    by Carlos Milovic, Patrick S. Fuchs, Mathias Lambert, Oriana Arsenov, Oliver C. Kiersnowski, Laxmi Muralidharan, Russell Murdoch, Jannette Nassar, Karin Shmueli


  • Open Access

    Interpretable machine learning model for characterizing magnetic susceptibility-based biomarkers in first episode psychosis

    by Pamela Franco, Cristian Montalba, Raúl Caulier-Cisterna, Carlos Milovic, Alfonso González, Juan Pablo Ramirez-Mahaluf, Juan Undurraga, Rodrigo Salas, Nicolás Crossley, Cristian Tejos, et al.


  • Open Access

    The statistical impact of ROI referencing on quantitative susceptibility mapping

    by Patrick S. Fuchs, Oliver C. Kiersnowski, Carlos Milovic, Karin Shmueli

    In quantitative susceptibility mapping (QSM), it is impossible to define an absolute reference for the reconstructed susceptibility values. Therefore, it has been suggested to use a relative reference, such as the mean susceptibility within an anatomical ROI. We investigated the theoretical basis of referencing, and what impact it may have on statistical ROI comparisons, particularly for clinical applications. We analysed a clinical epilepsy study and in-silico QSM reconstruction challenge data with various reference regions. The results are analysed as in a clinical study and resulting statistical variations are investigated from a theoretical point of view. We found that referencing has an impact on the significance of clinical findings. These effects may arise from a change in the precision of test statistics due to referencing. We also show potential biasing of results from referencing. Our findings suggest there may not be one “optimal” reference region, and care should always be taken with reference region selection depending on the specific pathology or cohort under investigation. Not explicitly referencing is less likely to lead to false positives than cherry picking a reference region to maximize statistically significant results. We encourage results to be published with their reference to facilitate future comparisons of datasets from different sources.


  • XSIM: A structural similarity index measure optimized for MRI QSM

    by Carlos Milovic, Cristian Tejos, Javier Silva, Karin Shmueli, Pablo Irarrazaval

    Purpose: The structural similarity index measure (SSIM) has become a popular quality metric to evaluate QSM in a way that is closer to human perception than RMS error (RMSE). However, SSIM may overpenalize errors in diamagnetic tissues and underpenalize them in paramagnetic tissues, resulting in biasing. In addition, extreme artifacts may compress the dynamic range, resulting in unrealistically high SSIM scores (hacking). To overcome biasing and hacking, we propose XSIM: SSIM implemented in the native QSM range, and with internal parameters optimized for QSM.Methods: We used forward simulations from a COSMOS ground‐truth brain susceptibility map included in the 2016 QSM Reconstruction Challenge to investigate the effect of QSM reconstruction errors on the SSIM, XSIM, and RMSE metrics. We also used these metrics to optimize QSM reconstructions of the in vivo challenge data set. We repeated this experiment with the QSM abdominal phantom. To validate the use of XSIM instead of SSIM for QSM quality assessment across a range of different reconstruction techniques/algorithms, we analyzed the reconstructions submitted to the 2019 QSM Reconstruction Challenge 2.0.Results: Our experiments confirmed the biasing and hacking effects on the SSIM metric applied to QSM. The XSIM metric was robust to those effects, penalizing the presence of streaking artifacts and reconstruction errors. Using XSIM to optimize QSM reconstruction regularization weights returned less overregularization than SSIM and RMSE.Conclusion: XSIM is recommended over traditional SSIM to evaluate QSM reconstructions against a known ground truth, as it avoids biasing and hacking effects and provides a larger dynamic range of scores.


  • Open Access

    Toward a realistic in silico abdominal phantom for QSM

    by Javier Silva, Carlos Milovic, Mathias Lambert, Cristian Montalba, Cristóbal Arrieta, Pablo Irarrazaval, Sergio Uribe, Cristian Tejos

    Purpose: QSM outside the brain has recently gained interest, particularly in the abdominal region. However, the absence of reliable ground truths makes difficult to assess reconstruction algorithms, whose quality is already compromised by additional signal contributions from fat, gases, and different kinds of motion. This work presents a realistic in silico phantom for the development, evaluation and comparison of abdominal QSM reconstruction algorithms.Methods: Synthetic susceptibility and R-2(& lowast;) maps were generated by segmenting and post processing the abdominal 3T MRI data from a healthy volunteer. Susceptibility and R-2(& lowast;) values in different tissues/organs were assigned according to literature and experimental values and were also provided with realistic textures. The signal was simulated using as input the synthetic QSM and R-2(& lowast;) maps and fat contributions. Three susceptibility scenarios and two acquisition protocols were simulated to compare different reconstruction algorithms.Results: QSM reconstructions show that the phantom allows to identify the main strengths and limitations of the acquisition approaches and reconstruction algorithms, such as in-phase acquisitions, water-fat separation methods, and QSM dipole inversion algorithms.Conclusion: The phantom showed its potential as a ground truth to evaluate and compare reconstruction pipelines and algorithms. The publicly available source code, designed in a modular framework, allows users to easily modify the susceptibility, R-2(& lowast;) and TEs, and thus creates different abdominal scenarios.


  • Open Access

    Hybrid data fidelity term approach for quantitative susceptibility mapping

    by Mathias Lambert, Cristian Tejos, Christian Langkammer, Carlos Milovic

    Purpose Susceptibility maps are usually derived from local magnetic field estimations by minimizing a functional composed of a data consistency term and a regularization term. The data-consistency term measures the difference between the desired solution and the measured data using typically the L2-norm. It has been proposed to replace this L2-norm with the L1-norm, due to its robustness to outliers and reduction of streaking artifacts arising from highly noisy or strongly perturbed regions. However, in regions with high SNR, the L1-norm yields a suboptimal denoising performance. In this work, we present a hybrid data fidelity approach that uses the L1-norm and subsequently the L2-norm to exploit the strengths of both norms. Methods We developed a hybrid data fidelity term approach for QSM (HD-QSM) based on linear susceptibility inversion methods, with total variation regularization. Each functional is solved with ADMM. The HD-QSM approach is a two-stage method that first finds a fast solution of the L1-norm functional and then uses this solution to initialize the L2-norm functional. In both norms we included spatially variable weights that improve the quality of the reconstructions. Results The HD-QSM approach produced good quantitative reconstructions in terms of structural definition, noise reduction, and avoiding streaking artifacts comparable with nonlinear methods, but with higher computational efficiency. Reconstructions performed with this method achieved first place at the lowest RMS error category in stage 1 of the 2019 QSM Reconstruction Challenge. Conclusions The proposed method allows robust and accurate QSM reconstructions, obtaining superior performance to state-of-the-art methods.


  • Open Access

    Streaking artifact suppression of quantitative susceptibility mapping reconstructions via L1‐norm data fidelity optimization (L1‐QSM)

    by Carlos Milovic, Mathias Lambert, Christian Langkammer, Kristian Bredies, Pablo Irarrazaval, Cristian Tejos

    Purpose: The presence of dipole‐inconsistent data due to substantial noise or artifacts causes streaking artifacts in quantitative susceptibility mapping (QSM) reconstructions. Often used Bayesian approaches rely on regularizers, which in turn yield reduced sharpness. To overcome this problem, we present a novel L1‐norm data fidelity approach that is robust with respect to outliers, and therefore prevents streaking artifacts.Methods: QSM functionals are solved with linear and nonlinear L1‐norm data fidelity terms using functional augmentation, and are compared with equivalent L2‐norm methods. Algorithms were tested on synthetic data, with phase inconsistencies added to mimic lesions, QSM Challenge 2.0 data, and in vivo brain images with hemorrhages.Results: The nonlinear L1‐norm‐based approach achieved the best overall error metric scores and better streaking artifact suppression. Notably, L1‐norm methods could reconstruct QSM images without using a brain mask, with similar regularization weights for different data fidelity weighting or masking setups.Conclusion: The proposed L1‐approach provides a robust method to prevent streaking artifacts generated by dipole‐inconsistent data, renders brain mask calculation unessential, and opens novel challenging clinical applications such asassessing brain hemorrhages and cortical layers.


  • Open Access

    QSM reconstruction challenge 2.0: Design and report of results

    by QSM Challenge 2.0 Organization Committee, Berkin Bilgic, Christian Langkammer, José P. Marques, Jakob Meineke, Carlos Milovic, Ferdinand Schweser

    Purpose: The aim of the second quantitative susceptibility mapping (QSM) reconstruction challenge (Oct 2019, Seoul, Korea) was to test the accuracy of QSM dipole inversion algorithms in simulated brain data.Methods: A two‐stage design was chosen for this challenge. The participants were provided with datasets of multi‐echo gradient echo images synthesized from two realisticin silicohead phantoms using an MR simulator. At the first stage, participants optimized QSM reconstructions without ground truth data available to mimic the clinical setting. At the second stage, ground truth data were provided for parameter optimization. Submissions were evaluated using eight numerical metrics and visual ratings.Results: A total of 98 reconstructions were submitted for stage 1 and 47 submissions for stage 2. Iterative methods had the best quantitative metric scores, followed by deep learning and direct inversion methods. Priors derived from magnitude data improved the metric scores. Algorithms based on iterative approaches and total variation (and its derivatives) produced the best overall results. The reported results and analysis pipelines have been made public to allow researchers to compare new methods to the current state of the art.Conclusion: The synthetic data provide a consistent framework to test the accuracy and robustness of QSM algorithms in the presence of noise, calcifications and minor voxel dephasing effects. Total Variation‐based algorithms produced the best results among all metrics. Future QSM challenges should assess whether this good performance with synthetic datasets translates to more realistic scenarios, where background fields and dipole‐incompatible phase contributions are included.


  • Open Access

    QSM reconstruction challenge 2.0: A realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures

    by José P. Marques, Jakob Meineke, Carlos Milovic, Berkin Bilgic, Kwok‐Shing Chan, Renaud Hedouin, Wietske van der Zwaag, Christian Langkammer, Ferdinand Schweser

    Purpose: To create a realistic in silico head phantom for the second QSM reconstruction challenge and for future evaluations of processing algorithms for QSM.Methods: We created a digital whole‐head tissue property phantom by segmenting and postprocessing high‐resolution (0.64 mm isotropic), multiparametric MRI data acquired at 7 T from a healthy volunteer. We simulated the steady‐state magnetization at 7 T using a Bloch simulator and mimicked a Cartesian sampling scheme through Fourier‐based processing. Computer code for generating the phantom and performing the MR simulation was designed to facilitate flexible modifications of the phantom in the future, such as the inclusion of pathologies as well as the simulation of a wide range of acquisition protocols. Specifically, the following parameters and effects were implemented: TR and TE, voxel size, background fields, and RF phase biases. Diffusion‐weighted imaging phantom data are provided, allowing future investigations of tissue‐microstructure effects in phase and QSM algorithms.Results: The brain part of the phantom featured realistic morphology with spatial variations in relaxation and susceptibility values similar to the in vivo setting. We demonstrated some of the phantom’s properties, including the possibility of generating phase data with nonlinear evolution over TE due to partial‐volume effects or complex distributions of frequency shifts within the voxel.Conclusion: The presented phantom and computer programs are publicly available and may serve as a ground truth in future assessments of the faithfulness of quantitative susceptibility reconstruction algorithms.


  • Open Access

    QSM Reconstruction Challenge 2.0: Design and Report of Results

    by Berkin Bilgic, Christian Langkammer, José P. Marques, Jakob Meineke, Carlos Milovic, Ferdinand Schweser

    Purpose: The aim of the second quantitative susceptibility mapping (QSM) reconstruction challenge (Oct 2019, Seoul, Korea) was to test the accuracy of QSM dipole inversion algorithms in simulated brain data. Methods: A two-stage design was chosen for this challenge. The participants were provided with datasets of multi-echo gradient echo images synthesized from two realistic in silico head phantoms using an MR simulator. At the first stage, participants optimized QSM reconstructions without ground-truths available to mimic the clinical setting. At the second stage, ground-truths were provided for parameter optimization.Submissions were evaluated using eight numerical metrics and visual ratings. Results: A total of 98 reconstructions were submitted for stage 1 and 47 submissions for stage 2. Iterative methods had the best quantitative metric scores, followed by deep-learning and direct inversion methods. Priors derived from magnitude data improved the metric scores. Algorithms based on iterative approaches and Total Variation (and its derivatives) produced the best overall results. The reported results and analysis pipelines have been made public to allow researchers to compare new methods to the current state of the art. Conclusion: The synthetic data provides a consistent framework to test the accuracy and robustness of QSM algorithms in the presence of noise, calcifications and minor voxel dephasing effects. Total Variation-based algorithmsproduced the best results along all metrics. Future QSM challenges should asses if this good performance with synthetic datasets translates to more realistic scenarios, where background fields and dipole-incompatible phase contributions are included.