BZBinfeng Zhang

Binfeng Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Binfeng Zhang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Optimized Single-Stage Isolated Swiss-Type AC/DC Converter Based on Single Full-Bridge With Midpoint-Clamper

    by Binfeng Zhang, Shaojun Xie, Zhouyang Li, Pengcheng Zhao, Jinming Xu

    The Swiss-type rectifier (SR) uses harmonic injection circuit and two dc–dc converters to help three-phase uncontrolled rectifier bridge to achieve better power factor correction (PFC). By applying the full-bridge topology to the dc structure, both the soft switching and the high-frequency galvanic isolation can be achieved. However, two full-bridge structures are required to realize the PFC principle of SR. That means the current flows through at least four switches and two transformers during the power conduction or freewheeling period. There are improvements in both conduction loss and core utilization. Thus, an optimized single-stage isolated Swiss-type ac/dc converter based on a single full-bridge with midpoint-clamper is proposed. Only one full-bridge structure is used to improve the conduction loss and core utilization. Two bidirectional voltage clampers are used to implement the PFC principle of the SR. The performance of the proposed converter has been verified by experiments. A total of 95.4% efficiency under half rated power and 5% input current THD under rated power have been achieved under a 10-kW 380 Vac input/400 Vdc output prototype with 90 kHz switching frequency.


  • Modulation Method and Control Strategy for Full-Bridge-Based Swiss Rectifier to Achieve ZVS Operation and Suppress Low-Order Harmonics of Injected Current

    by Binfeng Zhang, Shaojun Xie, Xincheng Wang, Jinming Xu

    The Swiss-type rectifier uses a three-phase unfolder circuit to convert the AC voltage into two time-varying positive voltages. The power factor correction of AC sides and the stable DC voltage output can be realized by using two DC-DC topologies without any bulky decoupling capacitors. By applying the phase-shifted full bridge topology into the DC structure, both the soft switching and the high frequency electrical isolation can be achieved. However, the power coupling between two full bridges using the traditional modulation method will affect the zero-voltage switching condition of lagging legs. Then, the duty cycle loss caused by the transformer leakage inductance will affect the input and output performance. Therefore, a new method using the up-counting mode modulation is proposed to implement the ZVS for both the lagging switches. Then, the relationship between the duty cycle loss and the extra 6N±1 harmonics added into the input current is theoretically analyzed. Hence, a novel compensation strategy is proposed. The proposed modulation method and control strategy have been successfully verified by the experiments. 95% efficiency under half rated power and 3% input current THD under rated power have been achieved under a 10kW 380Vac input/400Vdc output prototype with 90 kHz switching frequency.


  • An Optimized Single-Stage isolated Phase-Shifted Full-Bridge Based Swiss-rectifier

    by Binfeng Zhang, Shaojun Xie, Jinming Xu, Kunshan Xu, Zhouyang Li

    Swiss-rectifier (SR) is a family of high efficient AC-DC topologies. It's a combination of a three phase unfolder circuit which can convert the three-phase AC voltage into two sets of cyclically varying DC voltages and two symmetric DC-DC converters to achieve power factor correction (PFC). In order to obtain a zero voltage switching (ZVS) isolated single-stage rectifier system, two phase-shifted full-bridge topologies are applied to increase the working frequency of the magnetic elements. However, the current flows through at least four switches during the power conduction or freewheeling period. It is not conducive to improve the efficiency of full-bridge based SR. Thus, an optimized single-stage isolated phase-shifted full-bridge (PSFB) based Swiss-rectifier is proposed. Only one full bridge structure is used to reduce the conduction loss when the power is transmitting. Two voltage clamp branches are used to implement the PFC principle of the SWISS-rectifier. The principle of operation and the analytical equations for the stress in the semiconductor devices are discussed specifically. The performances of the proposed converter are verified by the experiments on a 10-kW 380Vac input/400Vdc output prototype with 90kHz switching frequency.


  • Harmonics and Stability Analysis of Single-Phase Grid-Connected Inverters in Distributed Power Generation Systems Considering Phase-Locked Loop Impact

    by Jinming Xu, Qiang Qian, Binfeng Zhang, Shaojun Xie

    In the distributed power generation systems (DPGSs) based on the renewable energies, the stability and harmonics of the grid-connected inverter are seriously affected by the uncertainties of the grid at the point of common coupling (PCC). More importantly, as several inverters are usually tied at the PCC together, the interactions among the inverters and the grid impedance can cause more serious harmonics and instabilities at the low frequencies. Hence, the phase-locked loop (PLL) affecting the low-frequency behaviors must be considered. This study aims to provide a comprehensive study of the stability and harmonics of single-phase inverters in the weak grid. Modellings of single-inverter and multiple-inverters systems considering the PLL are established. The impacts of different PLLs on the low-order current harmonics and stability are then studied. It has been proved that the maximum ability of inverters in suppressing the low-order grid current harmonics closely relates to the PLL, even if a harmonic resonant controller and/or PCC voltage feedforward is used. Thus, using different PLLs yields quite different performances. Simulation and experimental results will be given to demonstrate the analysis which is helpful for readers to design a proper PLL for DPGSs.


  • Robust Grid Current Control With Impedance-Phase Shaping for LCL-Filtered Inverters in Weak and Distorted Grid

    by Jinming Xu, Shaojun Xie, Binfeng Zhang, Qiang Qian

    For the grid-connected LCL-filtered inverter, the grid current feedback active damping (AD) can assure a desirable bandwidth and a good robustness against certain parameter variations by using a minimal number of sensors. However, the inverter performance was seriously endangered by non-ideal conditions at the point of common coupling (PCC), including background voltage distortions and grid impedance varying. The grid current AD could not work well for wide grid impedance variation. Hence, in this study, the robustness with such control is discussed and its relations with system parameters are derived through mathematic derivations. It is proved that, for the typical grid current AD control, a contradiction between high bandwidth and high robustness exists. On the basis of analyzing the reasons for the limitations of the typical control, a systematic approach for enhancing the robustness under complex grid conditions has been proposed. The proposed fundamental PCC voltage feedforward enhances the robustness while the proposed phase shaping compensator assures a higher robustness with a desired bandwidth. Comparative waveforms with the typical grid current AD control have been provided to verify the correctness of the analysis and the improvement of the proposed approach.