Toru Hyakutake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Toru Hyakutake has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
Hideki Takeuchi
Department of Mechanical Engineering, Kochi National College of Technology
17 shared publicationsKyoji Yamamoto
Department of Mechanical Engineering, Faculty of Engineering, Okayama University, Okayama 700‐8530, Japan
16 shared publicationsShinichiro Yanase
Graduate School of Natural Science and Technology, Okayama University, Okayama, Japan
15 shared publications- Shinichiro Yanase
Okayama University
8 shared publications Takeshi Matsumoto
Osaka University
7 shared publications- Kyoji Yamamoto
Okayama University
6 shared publications
Latest Publications
- Open Access
- 29 October 2026
- Published by Springer Nature in Biomedical Microdevices
- Vol. 28 (4) , 74
Hydrostatically driven microfluidic sorting of highly motile sperm using multiple parallel microchannels via rheotaxis and thigmotaxis
- 29 October 2026
- Published by Springer Nature in Biomedical Microdevices
- Vol. 28 (4) , 74
Open AccessHydrostatically driven microfluidic sorting of highly motile sperm using multiple parallel microchannels via rheotaxis and thigmotaxis
- Open Access
- 12 March 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 53
A numerical study on the effect of laser therapy against port-wine stain by administering artificial red blood cells
Port-wine stain (PWS) is a congenital vascular malformation commonly treated with pulsed dye laser (PDL) therapy. PDL exploits selective photothermolysis, in which hemoglobin in red blood cells (RBCs) absorbs laser energy, generating localized heat that induces endothelial damage. However, in microvessels, axial RBC migration creates a hemoglobin-depleted cell-free layer along the vessel walls, reducing laser efficacy. Hemoglobin vesicles (HbVs)—nano-sized artificial RBCs—distribute uniformly within these layers, offering the potential to enhance hemoglobin distribution and laser absorption. To investigate the impact of HbV administration on PDL therapy, a three-dimensional numerical model of human skin tissue containing vascular networks was developed. Monte Carlo simulations were used to evaluate laser absorption, and thermal conduction analysis was performed to compute temperature distributions and estimate thermal damage via the Arrhenius model. Two conditions were considered: Case 1 (without HbV administration) and Case 2 (with HbV administration). In Case 2, HbV administration increased optical absorption in vessel walls and enhanced thermal damage, particularly in subpapillary vessels. The threshold energy fluence required to induce irreversible thermal damage was reduced, and heat flux at the upper vessel walls was elevated. These findings indicate that HbV administration enhances the homogeneity and efficacy of PDL-induced vascular damage, potentially allowing effective treatment at lower energy fluences while minimizing off-target tissue injury. The study provides a theoretical basis for optimizing PDL parameters in PWS therapy and underscores the potential of patient-specific treatment protocols using artificial blood substitutes.
- 12 March 2026
- Published by Springer Nature in Lasers in Medical Science
- Vol. 41 (1) , 53
Open AccessA numerical study on the effect of laser therapy against port-wine stain by administering artificial red blood cells
Port-wine stain (PWS) is a congenital vascular malformation commonly treated with pulsed dye laser (PDL) therapy. PDL exploits selective photothermolysis, in which hemoglobin in red blood cells (RBCs) absorbs laser energy, generating localized heat that induces endothelial damage. However, in microvessels, axial RBC migration creates a hemoglobin-depleted cell-free layer along the vessel walls, reducing laser efficacy. Hemoglobin vesicles (HbVs)—nano-sized artificial RBCs—distribute uniformly within these layers, offering the potential to enhance hemoglobin distribution and laser absorption. To investigate the impact of HbV administration on PDL therapy, a three-dimensional numerical model of human skin tissue containing vascular networks was developed. Monte Carlo simulations were used to evaluate laser absorption, and thermal conduction analysis was performed to compute temperature distributions and estimate thermal damage via the Arrhenius model. Two conditions were considered: Case 1 (without HbV administration) and Case 2 (with HbV administration). In Case 2, HbV administration increased optical absorption in vessel walls and enhanced thermal damage, particularly in subpapillary vessels. The threshold energy fluence required to induce irreversible thermal damage was reduced, and heat flux at the upper vessel walls was elevated. These findings indicate that HbV administration enhances the homogeneity and efficacy of PDL-induced vascular damage, potentially allowing effective treatment at lower energy fluences while minimizing off-target tissue injury. The study provides a theoretical basis for optimizing PDL parameters in PWS therapy and underscores the potential of patient-specific treatment protocols using artificial blood substitutes.
- 20 September 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 176, 112336
Prediction of sperm motion behavior in microfluidic channel using sperm swimming model
- 20 September 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 176, 112336
Prediction of sperm motion behavior in microfluidic channel using sperm swimming model
- Open Access
- 14 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1421
Red Blood Cell Partitioning Using a Microfluidic Channel with Ladder Structure
This study investigated the partitioning characteristics of red blood cells (RBCs) within capillaries, with a specific focus on ladder structures observed near the end of the capillaries. In vitro experiments were conducted using microfluidic channels with a ladder structure model comprising six bifurcating channels that exhibited an anti-parallel flow configuration. The effects of various factors, such as the parent channel width, distance between branches, and hematocrit, on RBC partitioning in bifurcating channels were evaluated. A decrease in the parent channel width resulted in an increase in the heterogeneity in the hematocrit distribution and a bias in the fractional RBC flux. Additionally, variations in the distance between branches affected the RBC distribution, with smaller distances resulting in greater heterogeneity. The bias of the RBC distribution in the microchannel cross section had a major effect on the RBC partitioning characteristics. The influence of hematocrit variations on the RBC distribution was also investigated, with lower hematocrit values leading to a more pronounced bias in the RBC distribution. Overall, this study provides valuable insights into RBC distribution characteristics in capillary networks, contributing to our understanding of the physiological mechanisms of RBC phase separation in the microcirculatory system. These findings have implications for predicting oxygen heterogeneity in tissues and could aid in the study of diseases associated with impaired microcirculation.
- 14 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1421
Open AccessRed Blood Cell Partitioning Using a Microfluidic Channel with Ladder Structure
This study investigated the partitioning characteristics of red blood cells (RBCs) within capillaries, with a specific focus on ladder structures observed near the end of the capillaries. In vitro experiments were conducted using microfluidic channels with a ladder structure model comprising six bifurcating channels that exhibited an anti-parallel flow configuration. The effects of various factors, such as the parent channel width, distance between branches, and hematocrit, on RBC partitioning in bifurcating channels were evaluated. A decrease in the parent channel width resulted in an increase in the heterogeneity in the hematocrit distribution and a bias in the fractional RBC flux. Additionally, variations in the distance between branches affected the RBC distribution, with smaller distances resulting in greater heterogeneity. The bias of the RBC distribution in the microchannel cross section had a major effect on the RBC partitioning characteristics. The influence of hematocrit variations on the RBC distribution was also investigated, with lower hematocrit values leading to a more pronounced bias in the RBC distribution. Overall, this study provides valuable insights into RBC distribution characteristics in capillary networks, contributing to our understanding of the physiological mechanisms of RBC phase separation in the microcirculatory system. These findings have implications for predicting oxygen heterogeneity in tissues and could aid in the study of diseases associated with impaired microcirculation.
- 1 March 2022
- Published by Elsevier in Microvascular Research
- Vol. 140, 104281
In vitro study on the partitioning of red blood cells using a microchannel network
- 1 March 2022
- Published by Elsevier in Microvascular Research
- Vol. 140, 104281
In vitro study on the partitioning of red blood cells using a microchannel network
- 1 January 2022
- Published by The Membrane Society of Japan in MEMBRANE
- Vol. 47 (5) , 257-262
Study on Flow Properties and Oxygen Transport of Hemoglobin–based Oxygen Carriers through Microvessels
In this paper, two topics were presented: In the first topic, we investigated the RBC partitioning properties in a microvascular bifurcation model using both numerical simulation and in vitro experiment. When HbVs were perfused, they compensated for the small RBC flux and facilitated oxygen supply into the lower–flow branch. In addition, HbV perfusion has an effect of reducing oxygen heterogeneity in the capillary network. In the second topic, a microvascular model including the tissue region was constructed to simulate the reaction–diffusion phenomena of oxygenated HBOCs and oxygen. As a result, the presence of a plasma layer affected the oxygen transport in RBCs. In addition to oxygen affinity, the diffusion coefficient that depends on the HBOC size also had a significant impact on oxygen transport to the tissue.
- 1 January 2022
- Published by The Membrane Society of Japan in MEMBRANE
- Vol. 47 (5) , 257-262
Study on Flow Properties and Oxygen Transport of Hemoglobin–based Oxygen Carriers through Microvessels
In this paper, two topics were presented: In the first topic, we investigated the RBC partitioning properties in a microvascular bifurcation model using both numerical simulation and in vitro experiment. When HbVs were perfused, they compensated for the small RBC flux and facilitated oxygen supply into the lower–flow branch. In addition, HbV perfusion has an effect of reducing oxygen heterogeneity in the capillary network. In the second topic, a microvascular model including the tissue region was constructed to simulate the reaction–diffusion phenomena of oxygenated HBOCs and oxygen. As a result, the presence of a plasma layer affected the oxygen transport in RBCs. In addition to oxygen affinity, the diffusion coefficient that depends on the HBOC size also had a significant impact on oxygen transport to the tissue.
- 10 May 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (12) , 1269-1276
Hydrodynamic Approach for Revealing Venous Anastomotic Stenosis Formation Within a Dialysis Arteriovenous Graft
A conventional arteriovenous graft in patients on dialysis often leads to anastomotic stenosis, which decreases the blood flow rate and increases the risk of complications. In this study, based on hydrodynamics, the pulsatile pressure at the blood vessel graft–vein junction was investigated experimentally and numerically for revealing the causes of stenosis formation and inward remodeling. In the experiments, the pulsatile pressure and displacement at the anastomotic connection were measured at a branched collapsible tube. It was revealed that the pressure becomes negative between pressure peaks of the pulsatile flow; furthermore, tube diameter changes in accordance with the pressure pulsation. Subsequently, numerical simulations revealed that a relatively large pressure difference occurs at the anastomotic connection because of flow collision and separation as compared with the other part, and the pulsatile pressure. Therefore, it is possible that vein at an anastomotic connection may change its shape under pulsating flow. Furthermore, it was found that the pressure difference slightly increased with the anastomosis angle, but the anastomosis angle did not affect the flow rate. Clinical trials in the next step are required to reveal the causal relationship between stenosis and the pulsatile pressure, but the pulsatile flow and its pressure are likely to be one factor in stenosis and inward remodeling.
- 10 May 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (12) , 1269-1276
Hydrodynamic Approach for Revealing Venous Anastomotic Stenosis Formation Within a Dialysis Arteriovenous Graft
A conventional arteriovenous graft in patients on dialysis often leads to anastomotic stenosis, which decreases the blood flow rate and increases the risk of complications. In this study, based on hydrodynamics, the pulsatile pressure at the blood vessel graft–vein junction was investigated experimentally and numerically for revealing the causes of stenosis formation and inward remodeling. In the experiments, the pulsatile pressure and displacement at the anastomotic connection were measured at a branched collapsible tube. It was revealed that the pressure becomes negative between pressure peaks of the pulsatile flow; furthermore, tube diameter changes in accordance with the pressure pulsation. Subsequently, numerical simulations revealed that a relatively large pressure difference occurs at the anastomotic connection because of flow collision and separation as compared with the other part, and the pulsatile pressure. Therefore, it is possible that vein at an anastomotic connection may change its shape under pulsating flow. Furthermore, it was found that the pressure difference slightly increased with the anastomosis angle, but the anastomosis angle did not affect the flow rate. Clinical trials in the next step are required to reveal the causal relationship between stenosis and the pulsatile pressure, but the pulsatile flow and its pressure are likely to be one factor in stenosis and inward remodeling.
- 1 March 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 118, 110290
Experimental study on the effect of flow in microfluidic channel on bovine sperm navigation
- 1 March 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 118, 110290
Experimental study on the effect of flow in microfluidic channel on bovine sperm navigation
- Open Access
- 14 January 2020
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 306, 01006
Numerical simulations of blood cell flow in non-Newtonian fluid
We investigated how non-Newtonian viscosity behavior affects the flow characteristics of blood cells. Our findings offer insight about how shear thinning affects the dispersion of liposome-encapsulated hemoglobin and red blood cells in blood. The lattice Boltzmann method was used for fluid calculations, and the rheological properties of the non-Newtonian fluid were modeled with power-law relationships. The deformable three-dimensional red blood cell model was applied. First, we investigated the effects of shear thinning on the flow behavior of single blood cell. Simulation results indicate that shear thinning promotes the axial concentration of red blood cells. Next, varied the hematocrit to see how mutual interference between blood cells affects flow. At low hematocrit, shear thinning clearly promotes the axial concentration of red blood cells. As the hematocrit increases, in contrast, mutual interference has a greater effect, which counteracts shear thinning so the red blood cell distribution resembles the distribution within a Newtonian fluid.
- 14 January 2020
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 306, 01006
Open AccessNumerical simulations of blood cell flow in non-Newtonian fluid
We investigated how non-Newtonian viscosity behavior affects the flow characteristics of blood cells. Our findings offer insight about how shear thinning affects the dispersion of liposome-encapsulated hemoglobin and red blood cells in blood. The lattice Boltzmann method was used for fluid calculations, and the rheological properties of the non-Newtonian fluid were modeled with power-law relationships. The deformable three-dimensional red blood cell model was applied. First, we investigated the effects of shear thinning on the flow behavior of single blood cell. Simulation results indicate that shear thinning promotes the axial concentration of red blood cells. Next, varied the hematocrit to see how mutual interference between blood cells affects flow. At low hematocrit, shear thinning clearly promotes the axial concentration of red blood cells. As the hematocrit increases, in contrast, mutual interference has a greater effect, which counteracts shear thinning so the red blood cell distribution resembles the distribution within a Newtonian fluid.
- 17 September 2019
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (1) , 53-61
Study of the Partitioning of Red Blood Cells Through Asymmetric Bifurcating Microchannels
- 17 September 2019
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (1) , 53-61
Study of the Partitioning of Red Blood Cells Through Asymmetric Bifurcating Microchannels