Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weidong Huang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Bowen Liu

    Department of Environmental Science and Engineering, University of Science and Technology of China, 96 Jinzhai Road, Hefei 230026, China

    5 shared publications
  • Qian Xu

    Department of Earth and Space Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026, China

    3 shared publications
  • Chenggang Zong

    Asset Management Co., University of Science and Technology of China, 96 Jinzhai Road, Hefei 230026, China

    2 shared publications
  • Fei Shen

    Anhui Province Key Laboratory of Polar Environment and Global Change, Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei 230026, China

    2 shared publications
  • Huairui Li

    Department of Earth Chemistry and Environmental Science, University of Science and Technology of China, Hefei, Anhui 230026, PR China

    2 shared publications
  • Liang Yu

    2 shared publications

Latest Publications

  • Open Access

    Direct calculation of heliostat efficiency by ray tracing model with three beams of rays

    by Weidong Huang, Hang Yin

    Solar concentrators predominantly adopt glass back reflectors for solar energy concentration. When a single incident light beam undergoes multiple reflections on both the front and back surfaces of the reflector, multiple reflected beams with distinct divergence are generated. This study proposes a ray tracing model specifically designed for the direct calculation of heliostat efficiency. The proposed model incorporates simulations of the three primary reflected beams as well as the actual solar intensity distribution. Experimental data were utilized to validate the optical performance model of the spherical heliostat, and the validation results demonstrated a strong correlation with the measured data. The average root mean square error of the interception rate was merely 0.31%, with a maximum value of 0.68%—a result significantly lower than those obtained by alternative calculation methods. The ray tracing model presented herein for the direct calculation of heliostat interception rate exhibits high computational accuracy, rendering it applicable to the operation, maintenance, and design optimization of solar tower systems, thereby contributing to the enhancement of system performance. This research constitutes a significant advancement in the application of artificial intelligence within the field of solar energy utilization.

  • Open Access

    Performance Simulation and Optimization of Cylindrical Mirror-Spliced Parabolic Trough Solar Collector

    by Bowen Liu, Vian Mbabazi, Weidong Huang

    This paper proposes a new type of solar trough collector with a spliced cylindrical mirror and develops a new ray-tracing method to predict and optimize its performance. The mirrors of this system are composed of multiple cylindrical mirrors whose centers are on a parabola, and the normal vector of the centers of each cylindrical mirror is consistent with the normal vector of the parabola point where it is located. The new ray-tracing method is based on the transverse distribution of solar radiation, and it has been validated with Soltrace, with the maximum intercept factor error in the calculations being less than 0.31%. This paper compares the spliced cylindrical mirror trough solar system with the conventional parabolic trough system and finds that the influence of cylindrical, spherical, and coma aberration can be reduced to negligible levels by adjusting the system design. At the same time, the slope error and cost of the cylindrical mirror are much less than the parabolic mirror so it has better performance from numerical simulation. The spliced cylindrical mirror system can be further optimized to achieve an annual net efficiency of 65.52% in the north–south horizontal axis tracking mode.


  • Open Access

    Performance Simulation and Optimization of Cylindrical Mirror Spliced Parabolic Trough Solar Collector

    by Bowen Liu, Vian Mbabazi, Weidong Huang

    This paper proposes a new type of solar trough collector with cylindrical mirror spliced and develops a new ray tracing method to predict and optimize its performance. The mirrors of this system are composed of multiple cylindrical mirrors whose centres are on a parabola and the normal vector of the centers of each cylindrical mirror is consistent with the normal vector of the parabola point where it is located. This paper compares the cylindrical mirror spliced trough solar system with the conventional parabolic trough system and finds that the influence of cylindrical spherical and coma aberration can be reduced to negligible levels by adjusting the system design. At the same time, the slope error and cost of the cylindrical mirror is much less than the parabolic mirror so it has better performance from numerical simulation. On the vernal equinox, the net efficiency of the cylindrical mirror spliced system using a cavity receiver is 22.39% higher than that of the conventional trough system using vacuum tube receiver. The cylindrical mirror spliced system can be further optimized to achieve an annual net efficiency of 60.2% in the north-south horizontal axis tracking mode.

  • Open Access

    Evaluation and Characterization of the Influence of Solar Position Algorithm on the Performance of Parabolic Trough Solar System

    by Bowen Liu, Chenggang Zong, Weidong Huang

    For the open loop control system based on the solar position algorithm (SPA), without sensor correction, the error of SPA will bring the tracking error directly to decrease the efficiency of the solar system. By comparing with SPA proposed by NREL, this paper first evaluates main SPAs with different accuracy and presents the error of SPA on tracking error. Based on the annual average efficiency of the solar trough system, this paper evaluates the impact of the tracking error caused by SPA on the solar trough system, and proposes that the average SPA calculation error can be applied to characterize the impact of SPA on the trough solar system. By making a comparison of solar trough system efficiency calculated with fixed annual average tracking error and normal constantly changing tracking error within a year, respectively, the evaluation results show that for most SPAs, the introduced error is less than 0.05%, and only a few empirical algorithms with large tracking errors introduce larger errors, but they are not suitable for the trough solar system. Therefore, the SPA evaluation method proposed in this paper is applicable to the solar trough system.


  • Open Access

    An Integration Model for Flux Density Distribution Formed by a Heliostat

    by Chenggang Zong, Yemao Shi, Liang Yu, Bowen Liu, Weidong Huang

    An accurate flux density calculation is essential for optimizing and designing solar tower systems. Most of the existing methods introduce multiple assumptions, and the accuracy and scope of the application are limited. This paper proposes an integration model used to calculate the flux density distribution after only applying the Gaussian model for solar brightness distribution. It is the first time that multiple reflections and the influence of the optical error transferred from different planes of the glass mirror are considered in order to build an optical model for the flux density of a heliostat. The reflection from two surfaces of the glass mirror used to form three main parts of beams was considered in the present model, and Fresnel’s equations were applied to calculate the energy of the three parts of reflected rays. An elliptic Gaussian model was applied for the optical error distribution of the heliostat. The model error was evaluated using the experimental data of ten heliostats, and the applicability and accuracy of the model were verified through flux distribution and an intercept factor. The average relative prediction error of the present model from the experimental data was only 2.83%, which is less than SolTrace and other models.


  • Open Access

    Solar Position Algorithm Based on the Kepler Equation

    by Weidong Huang, Bowen Liu

    When calculating the position of the sun, earth’s motion can be assumed to be an ellipse if the accuracy of calculation is required to be 0.01 degrees. Then, Kepler’s equation can be applied from the mean anomaly of the sun at a specific time to calculate the true anatomy of the sun at the time, and the sun’s position can be calculated. The average absolute error of calculating the sun’s altitude and azimuth is only 0.04 and 0.06 mrad, respectively, which can meet the requirements of a concentrated solar tracking system. This method only needs to correct the length of the regression year and the near point year for every 100 years, so it can be used for a long time.


  • Open Access

    Performance Prediction and Optimization of Multi-Mirror Combined Solar Dish Collector

    by Weidong Huang, Fei Shen, Lulening Sun, Chenggang Zong

    An analytical method to calculate and optimize the performance of a multi-mirror combined solar dish collector is proposed in this work. It is based on the method of directly calculating the optical efficiency of a reflecting point, which can consider the influence of many factors. The distribution of the reflected solar intensity is obtained by the convolution of the actual solar intensity distribution and Gaussian distribution of the optical error. Then, the optical efficiency for a single mirror is calculated through integration over the total area of the mirror, and the method is validated by the SolTrace code. It is a rather quick method that reduces the amount of calculation and keeps high accuracy. The heat loss per unit area for the cavity receiver is assumed to be constant at a definite operation temperature for performance analysis and optimization. Taking a 62.25 m2 combined dish system with 249 square spherical mirrors as an example, the effects of system focal length, open radius of receiver, optical error, and focal length of the mirror on the system intercept factor and efficiency are studied. An optimization model is developed for maximizing the annual average net thermal efficiency. If the mirrors used have the same focal length for reducing the manufacture cost, when the optical error is 2 mrad, the net thermal efficiency and the intercept factor of the optimized system are 85.87% and 98.60%, respectively, while the concentration ratio is about 2000.


  • Open Access

    Study on the Optical Properties of the Point-Focus Fresnel System

    by Fei Shen, Weidong Huang

    The characteristic analysis of the flux formed by the heliostat in the optical system is the basis in design and optimization of the whole system. In this paper, our research subject is a pilot installation of the point-focus Fresnel system, which is a new optical design between the tower system and the dish system. For the optical system, it is very important to accurately calculate the solar flux density distribution on the receiver plane. Aiming at the case that the focal length of the heliostat is not equal to the distance from the center of the heliostat to the center of the receiver plane, based on the projection, an approximate calculation method is proposed. Using the method to calculate the solar flux density distribution of the point-focus Fresnel system, and the results are compared with that calculated by SolTrace code, it is found that the solar flux density distribution of both is relatively consistent in shape and numerical value, which verifies the accuracy of the method and it can be used for design and optimization of the point-focus Fresnel system.


  • Open Access

    A new method to calculate the Total Fertility Rate from the number of birth

    by Weidong Huang

    The standard methods to calculate the Total Fertility Rate require the reliable age-specific fertility rate including birth data and the related age-specific women's population data. Historically, the number of births was often not counted according to the age of the mother, so it is difficult to estimate the historical total fertility rate with the standard methods. Many empirical methods have been proposed, but their application is limited to specific period and place. This paper deduces a new method for calculating the total fertility rate from the number of birth and the population of women at childbearing age, can be applied to most of cases. The relative error is usually less than 5%. It is easier to calculate TFR, and may be applied to obtain more TFRs for the history.