Cong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cong Zhou has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- James Geoffrey Chase
University of Canterbury
19 shared publications - Marcus Haggers
Tiro Medical Limited, Building Dg7, Dovedale Village, Dovedale Avenue, Ilam, Christchurch, 8041, New Zealand
6 shared publications - Geoffrey William Rodgers
Department of Mechanical Engineering University of Canterbury Christchurch New Zealand
4 shared publications J. Geoffrey Chase
4 shared publications- Qianhui Sun
GIGA-In Silico Medicine, University of Liège, Liège, Belgium
4 shared publications - Christopher G. Pretty
Department of Mechanical Engineering, University of Canterbury, New Zealand
3 shared publications
Latest Publications
- Open Access
- 25 November 2026
- Published by IOP Publishing
- Vol. 47 (11) , 115015
Gaussian Parameter Data
Gaussian decomposition of EIT reconstructions with different inclusion geometries, Hall, Henry, Holder-Pearson, Lui, Zhou, Cong, Möller, Knut, Chase, J Geoffrey Gaussian decomposition of EIT reconstructions with different inclusion geometries, Hall, Henry, Holder-Pearson, Lui, Zhou, Cong, Möller, Knut, Chase, J Geoffrey
- 25 November 2026
- Published by IOP Publishing
- Vol. 47 (11) , 115015
Open AccessGaussian Parameter Data
Gaussian decomposition of EIT reconstructions with different inclusion geometries, Hall, Henry, Holder-Pearson, Lui, Zhou, Cong, Möller, Knut, Chase, J Geoffrey Gaussian decomposition of EIT reconstructions with different inclusion geometries, Hall, Henry, Holder-Pearson, Lui, Zhou, Cong, Möller, Knut, Chase, J Geoffrey
- Open Access
- 11 November 2026
- Published by IOP Publishing in Physiological Measurement
Gaussian decomposition of EIT reconstructions with different inclusion geometries
Objective Electrical Impedance Tomography (EIT) is a developing medical imaging device. It is a non-invasive modality that operates by injecting a small amount of current into the body and measuring the boundary voltages. An ill-posed inverse problem is solved to determine an estimate of the internal impedance of the body. Due to the ill-posed nature and its associated physics, inclusions with different geometries may appear similar in reconstructed images. This work aims to identify differences between multiple inclusions of varying geometries utilizing a post processing method. It is hypothesized that the spatial variance of the reconstructed inclusion should change proportionately to the central diameter of the inclusion and the peak relative change in impedance should be consistent with the material type of the inclusion. Approach Several inclusions with different vertical geometries were imaged using a validate open-source EIT device at different positions in a saline phantom. The reconstructed images were analysed by considering a 1D slice of the impedance values. This 1D slice was approximated by a Gaussian function. It is proposed that the Gaussian parameters associated with an inclusion should change based on the inclusion geometry and material. Main Results When the 1D slice was coincident with the inclusion the Gaussian function was a good approximation (R2 ≥ 0.93). The Gaussian parameters followed repeatable patterns as the inclusion was moved to different positions. The amplitude was shown to only change with respect to the inclusion’s volume and not the geometry, as the image slice is effectively the average of the electric field solution. The standard deviation was consistent at 10 mm diameter irrespective of the inclusion geometry. Significance This simplified method was unable to distinguish between vertical inclusion geometries compared to the full EIT solution. However, the position and size of the inclusions can be recovered from the 1D slices. Thus, the same information about the inclusion can be determined from a 1D set of impedances as a 2D image.
- 11 November 2026
- Published by IOP Publishing in Physiological Measurement
Open AccessGaussian decomposition of EIT reconstructions with different inclusion geometries
Objective Electrical Impedance Tomography (EIT) is a developing medical imaging device. It is a non-invasive modality that operates by injecting a small amount of current into the body and measuring the boundary voltages. An ill-posed inverse problem is solved to determine an estimate of the internal impedance of the body. Due to the ill-posed nature and its associated physics, inclusions with different geometries may appear similar in reconstructed images. This work aims to identify differences between multiple inclusions of varying geometries utilizing a post processing method. It is hypothesized that the spatial variance of the reconstructed inclusion should change proportionately to the central diameter of the inclusion and the peak relative change in impedance should be consistent with the material type of the inclusion. Approach Several inclusions with different vertical geometries were imaged using a validate open-source EIT device at different positions in a saline phantom. The reconstructed images were analysed by considering a 1D slice of the impedance values. This 1D slice was approximated by a Gaussian function. It is proposed that the Gaussian parameters associated with an inclusion should change based on the inclusion geometry and material. Main Results When the 1D slice was coincident with the inclusion the Gaussian function was a good approximation (R2 ≥ 0.93). The Gaussian parameters followed repeatable patterns as the inclusion was moved to different positions. The amplitude was shown to only change with respect to the inclusion’s volume and not the geometry, as the image slice is effectively the average of the electric field solution. The standard deviation was consistent at 10 mm diameter irrespective of the inclusion geometry. Significance This simplified method was unable to distinguish between vertical inclusion geometries compared to the full EIT solution. However, the position and size of the inclusions can be recovered from the 1D slices. Thus, the same information about the inclusion can be determined from a 1D set of impedances as a 2D image.
- 3 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110485
Error propagation and uncertainty analysis in a virtual patient model for lung mechanics
- 3 June 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 194, 110485
Error propagation and uncertainty analysis in a virtual patient model for lung mechanics
- Open Access
- 13 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 724
A Hysteresis Model Incorporating Varying Pinching Stiffness and Spread for Enhanced Structural Damage Simulation
The widely used Bouc–Wen–Baber–Noori (BWBN) hysteresis model, although effective in simulating hysteresis behaviors, does not account for variations in the pinching region of hysteretic behaviors. This can negatively impact the accuracy of the BWBN model in simulating structural responses and damage mechanisms in structures such as reinforced concrete (RC) and timber, which exhibit highly pinched hysteresis behavior when damaged by earthquakes. This paper introduces a BWBN model with varying pinching region characteristics (BWBN-VP model) which can degrade pinching stiffness and increase pinching effects under seismic loads. Unlike the original BWBN model using constant pinching stiffness (), this modified new model, inspired by real-world structural damage, improves structural damage detection, identifiability, and analysis in real-world scenarios. Model validation uses experimental data from three RC column tests with different failure modes and hysteresis loop shapes, resulting in an ~0.98 correlation coefficient between the experimental and simulated responses. Further validation uses real-world seismic data from a six-story RC building and achieves an average correlation of ~0.97 with a minor 2.5% difference in the peak restoring forces compared to direct measurements. The proposed BWBN-VP model also accurately and realistically captures damage to both the elastic and pinching stiffness values of the building, with an average difference of ~4%. Results confirm that the BWBN-VP model, compared to the original, more accurately predicts hysteretic responses, especially in Shear Failure (SF) modes. Therefore, the BWBN-VP model, superior in simulating highly pinched behaviors in RC and timber structures, would be an advanced tool for resilient seismic design and Structural Health Monitoring (SHM).- 13 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 724
Open AccessA Hysteresis Model Incorporating Varying Pinching Stiffness and Spread for Enhanced Structural Damage Simulation
The widely used Bouc–Wen–Baber–Noori (BWBN) hysteresis model, although effective in simulating hysteresis behaviors, does not account for variations in the pinching region of hysteretic behaviors. This can negatively impact the accuracy of the BWBN model in simulating structural responses and damage mechanisms in structures such as reinforced concrete (RC) and timber, which exhibit highly pinched hysteresis behavior when damaged by earthquakes. This paper introduces a BWBN model with varying pinching region characteristics (BWBN-VP model) which can degrade pinching stiffness and increase pinching effects under seismic loads. Unlike the original BWBN model using constant pinching stiffness (), this modified new model, inspired by real-world structural damage, improves structural damage detection, identifiability, and analysis in real-world scenarios. Model validation uses experimental data from three RC column tests with different failure modes and hysteresis loop shapes, resulting in an ~0.98 correlation coefficient between the experimental and simulated responses. Further validation uses real-world seismic data from a six-story RC building and achieves an average correlation of ~0.97 with a minor 2.5% difference in the peak restoring forces compared to direct measurements. The proposed BWBN-VP model also accurately and realistically captures damage to both the elastic and pinching stiffness values of the building, with an average difference of ~4%. Results confirm that the BWBN-VP model, compared to the original, more accurately predicts hysteretic responses, especially in Shear Failure (SF) modes. Therefore, the BWBN-VP model, superior in simulating highly pinched behaviors in RC and timber structures, would be an advanced tool for resilient seismic design and Structural Health Monitoring (SHM). - Open Access
- 11 December 2024
- Published by Elsevier in Ocean Engineering
- Vol. 317
Effectiveness of deck-isolation and viscous dampers supplement on enhancing seismic performance of offshore jacket platforms
- 11 December 2024
- Published by Elsevier in Ocean Engineering
- Vol. 317
Open AccessEffectiveness of deck-isolation and viscous dampers supplement on enhancing seismic performance of offshore jacket platforms
- Open Access
- 6 November 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (1) , 015008
Multi-level digital-twin models of pulmonary mechanics: correlation analysis of 3D CT lung volume and 2D Chest motion
Creating multi-level digital-twin models for mechanical ventilation requires a detailed estimation of regional lung volume. An accurate generic map between 2D chest surface motion and 3D regional lung volume could provide improved regionalisation and clinically acceptable estimates localising lung damage. This work investigates the relationship between CT lung volumes and the forced vital capacity (FVC) a surrogate of tidal volume proven linked to 2D chest motion. In particular, a convolutional neural network (CNN) with U-Net architecture is employed to build a lung segmentation model using a benchmark CT scan dataset. An automated thresholding method is proposed for image morphology analysis to improve model performance. Finally, the trained model is applied to an independent CT dataset with FVC measurements for correlation analysis of CT lung volume projection to lung recruitment capacity. Model training results show a clear improvement of lung segmentation performance with the proposed automated thresholding method compared to a typically suggested fixed value selection, achieving accuracy greater than 95% for both training and independent validation sets. The correlation analysis for 160 patients shows a good correlation of R squared value of 0.73 between the proposed 2D volume projection and the FVC value, which indicates a larger and denser projection of lung volume relative to a greater FVC value and lung recruitable capacity. The overall results thus validate the potential of using non-contact, non-invasive 2D measures to enable regionalising lung mechanics models to equivalent 3D models with a generic map based on the good correlation. The clinical impact of improved lung mechanics digital twins due to regionalising the lung mechanics and volume to specific lung regions could be very high in managing mechanical ventilation and diagnosing or locating lung injury or dysfunction based on regular monitoring instead of intermittent and invasive lung imaging modalities.
- 6 November 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (1) , 015008
Open AccessMulti-level digital-twin models of pulmonary mechanics: correlation analysis of 3D CT lung volume and 2D Chest motion
Creating multi-level digital-twin models for mechanical ventilation requires a detailed estimation of regional lung volume. An accurate generic map between 2D chest surface motion and 3D regional lung volume could provide improved regionalisation and clinically acceptable estimates localising lung damage. This work investigates the relationship between CT lung volumes and the forced vital capacity (FVC) a surrogate of tidal volume proven linked to 2D chest motion. In particular, a convolutional neural network (CNN) with U-Net architecture is employed to build a lung segmentation model using a benchmark CT scan dataset. An automated thresholding method is proposed for image morphology analysis to improve model performance. Finally, the trained model is applied to an independent CT dataset with FVC measurements for correlation analysis of CT lung volume projection to lung recruitment capacity. Model training results show a clear improvement of lung segmentation performance with the proposed automated thresholding method compared to a typically suggested fixed value selection, achieving accuracy greater than 95% for both training and independent validation sets. The correlation analysis for 160 patients shows a good correlation of R squared value of 0.73 between the proposed 2D volume projection and the FVC value, which indicates a larger and denser projection of lung volume relative to a greater FVC value and lung recruitable capacity. The overall results thus validate the potential of using non-contact, non-invasive 2D measures to enable regionalising lung mechanics models to equivalent 3D models with a generic map based on the good correlation. The clinical impact of improved lung mechanics digital twins due to regionalising the lung mechanics and volume to specific lung regions could be very high in managing mechanical ventilation and diagnosing or locating lung injury or dysfunction based on regular monitoring instead of intermittent and invasive lung imaging modalities.
- Open Access
- 8 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12129
Integrating Virtual, Mixed, and Augmented Reality into Remote Robotic Applications: A Brief Review of Extended Reality-Enhanced Robotic Systems for Intuitive Telemanipulation and Telemanufacturing Tasks in Hazardous Conditions
There is an increasingly urgent need for humans to interactively control robotic systems to perform increasingly precise remote operations, concomitant with the rapid development of space exploration, deep-sea discovery, nuclear rehabilitation and management, and robotic-assisted medical devices. The potential high value of medical telerobotic applications was also evident during the recent coronavirus pandemic and will grow in future. Robotic teleoperation satisfies the demands of the scenarios in which human access carries measurable risk, but human intelligence is required. An effective teleoperation system not only enables intuitive human-robot interaction (HRI) but ensures the robot can also be operated in a way that allows the operator to experience the “feel” of the robot working on the remote side, gaining a “sense of presence”. Extended reality (XR) technology integrates real-world information with computer-generated graphics and has the potential to enhance the effectiveness and performance of HRI by providing depth perception and enabling judgment and decision making while operating the robot in a dynamic environment. This review examines novel approaches to the development and evaluation of an XR-enhanced telerobotic platform for intuitive remote teleoperation applications in dangerous and difficult working conditions. It presents a strong review of XR-enhanced telerobotics for remote robotic applications; a particular focus of the review includes the use of integrated 2D/3D mixed reality with haptic interfaces to perform intuitive remote operations to remove humans from dangerous conditions. This review also covers primary studies proposing Virtual Reality (VR), Augmented Reality (AR), and Mixed Reality (MR) solutions where humans can better control or interact with real robotic platforms using these devices and systems to extend the user’s reality and provide a more intuitive interface. The objective of this article is to present recent, relevant, common, and accessible frameworks implemented in research articles published on XR-enhanced telerobotics for industrial applications. Finally, we present and classify the application context of the reviewed articles in two groups: mixed reality–enhanced robotic telemanipulation and mixed reality–enhanced robotic tele-welding. The review thus addresses all elements in the state of the art for these systems and ends with recommended research areas and targets. The application range of these systems and the resulting recommendations is readily extensible to other application areas, such as remote robotic surgery in telemedicine, where surgeons are scarce and need is high, and other potentially high-risk/high-need scenarios.
- 8 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (22) , 12129
Open AccessIntegrating Virtual, Mixed, and Augmented Reality into Remote Robotic Applications: A Brief Review of Extended Reality-Enhanced Robotic Systems for Intuitive Telemanipulation and Telemanufacturing Tasks in Hazardous Conditions
There is an increasingly urgent need for humans to interactively control robotic systems to perform increasingly precise remote operations, concomitant with the rapid development of space exploration, deep-sea discovery, nuclear rehabilitation and management, and robotic-assisted medical devices. The potential high value of medical telerobotic applications was also evident during the recent coronavirus pandemic and will grow in future. Robotic teleoperation satisfies the demands of the scenarios in which human access carries measurable risk, but human intelligence is required. An effective teleoperation system not only enables intuitive human-robot interaction (HRI) but ensures the robot can also be operated in a way that allows the operator to experience the “feel” of the robot working on the remote side, gaining a “sense of presence”. Extended reality (XR) technology integrates real-world information with computer-generated graphics and has the potential to enhance the effectiveness and performance of HRI by providing depth perception and enabling judgment and decision making while operating the robot in a dynamic environment. This review examines novel approaches to the development and evaluation of an XR-enhanced telerobotic platform for intuitive remote teleoperation applications in dangerous and difficult working conditions. It presents a strong review of XR-enhanced telerobotics for remote robotic applications; a particular focus of the review includes the use of integrated 2D/3D mixed reality with haptic interfaces to perform intuitive remote operations to remove humans from dangerous conditions. This review also covers primary studies proposing Virtual Reality (VR), Augmented Reality (AR), and Mixed Reality (MR) solutions where humans can better control or interact with real robotic platforms using these devices and systems to extend the user’s reality and provide a more intuitive interface. The objective of this article is to present recent, relevant, common, and accessible frameworks implemented in research articles published on XR-enhanced telerobotics for industrial applications. Finally, we present and classify the application context of the reviewed articles in two groups: mixed reality–enhanced robotic telemanipulation and mixed reality–enhanced robotic tele-welding. The review thus addresses all elements in the state of the art for these systems and ends with recommended research areas and targets. The application range of these systems and the resulting recommendations is readily extensible to other application areas, such as remote robotic surgery in telemedicine, where surgeons are scarce and need is high, and other potentially high-risk/high-need scenarios.
- Open Access
- 24 October 2023
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 22 (1) , 1-21
Automated evaluation of typical patient–ventilator asynchronies based on lung hysteretic responses
Background: Patient–ventilator asynchrony is common during mechanical ventilation (MV) in intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is critical for optimizing MV settings to reduce or eliminate asynchrony, whilst current clinical visual inspection of all typical types of asynchronous breaths is difficult and inefficient. Patient asynchronies create a unique pattern of distortions in hysteresis respiratory behaviours presented in pressure–volume (PV) loop. Methods: Identification method based on hysteretic lung mechanics and hysteresis loop analysis is proposed to delineate the resulted changes of lung mechanics in PV loop during asynchronous breathing, offering detection of both its incidence and 7 major types. Performance is tested against clinical patient data with comparison to visual inspection conducted by clinical doctors. Results: The identification sensitivity and specificity of 11 patients with 500 breaths for each patient are above 89.5% and 96.8% for all 7 types, respectively. The average sensitivity and specificity across all cases are 94.6% and 99.3%, indicating a very good accuracy. The comparison of statistical analysis between identification and human inspection yields the essential same clinical judgement on patient asynchrony status for each patient, potentially leading to the same clinical decision for setting adjustment. Conclusions: The overall results validate the accuracy and robustness of the identification method for a bedside monitoring, as well as its ability to provide a quantified metric for clinical decision of ventilator setting. Hence, the method shows its potential to assist a more consistent and objective assessment of asynchrony without undermining the efficacy of the current clinical practice.
- 24 October 2023
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 22 (1) , 1-21
Open AccessAutomated evaluation of typical patient–ventilator asynchronies based on lung hysteretic responses
Background: Patient–ventilator asynchrony is common during mechanical ventilation (MV) in intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is critical for optimizing MV settings to reduce or eliminate asynchrony, whilst current clinical visual inspection of all typical types of asynchronous breaths is difficult and inefficient. Patient asynchronies create a unique pattern of distortions in hysteresis respiratory behaviours presented in pressure–volume (PV) loop. Methods: Identification method based on hysteretic lung mechanics and hysteresis loop analysis is proposed to delineate the resulted changes of lung mechanics in PV loop during asynchronous breathing, offering detection of both its incidence and 7 major types. Performance is tested against clinical patient data with comparison to visual inspection conducted by clinical doctors. Results: The identification sensitivity and specificity of 11 patients with 500 breaths for each patient are above 89.5% and 96.8% for all 7 types, respectively. The average sensitivity and specificity across all cases are 94.6% and 99.3%, indicating a very good accuracy. The comparison of statistical analysis between identification and human inspection yields the essential same clinical judgement on patient asynchrony status for each patient, potentially leading to the same clinical decision for setting adjustment. Conclusions: The overall results validate the accuracy and robustness of the identification method for a bedside monitoring, as well as its ability to provide a quantified metric for clinical decision of ventilator setting. Hence, the method shows its potential to assist a more consistent and objective assessment of asynchrony without undermining the efficacy of the current clinical practice.
- 6 October 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226
Low-cost structured light imaging of regional volume changes for use in assessing mechanical ventilation
- 6 October 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226
Low-cost structured light imaging of regional volume changes for use in assessing mechanical ventilation
- 18 September 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107146
Virtual patient framework for the testing of mechanical ventilation airway pressure and flow settings protocol
- 18 September 2022
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 226, 107146
Virtual patient framework for the testing of mechanical ventilation airway pressure and flow settings protocol