Kosaku Kurata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kosaku Kurata has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Takamatsu
Kyushu Univ, Dept Mech Engn, Fukuoka 8190395, Japan
19 shared publications - Takanobu Fukunaga
Kyushu University
16 shared publications Hiroshi Takamatsu
National Institute of Technology, Kumamoto College
13 shared publicationsSatoru Uchida
Dept. of Mech. Eng., Kyushu Univ
5 shared publicationsTakashi Yoshii
Kyushu Univ, Grad Sch Engn, Fukuoka, Japan
4 shared publicationsHaidong Wang
Kyushu University
3 shared publications
Latest Publications
- Open Access
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Edible anisotropic scaffolds derived from mushroom fruiting bodies enable myotube alignment through physical processing alone
Reproducing the texture of whole-cut meat remains a major challenge in cultured meat production, largely due to the difficulty of constructing aligned muscle structures using food-compatible materials. This study proposes edible anisotropic scaffolds derived from mushroom fruiting bodies as a low-processing, animal-free platform for myotube alignment. Fruiting bodies of edible mushrooms (Pleurotus eryngii, Pleurotus ostreatus, and Lentinula edodes) were prepared using only physical slicing, autoclave sterilization, drying, and rehydration, without chemical treatments. Infrared spectroscopy confirmed that the substrates consisted of polysaccharides, proteins, and lipids typical of edible fungi. Surface analysis revealed distinct anisotropic microstructures, especially in L. edodes, exhibiting the strongest anisotropy with the presence of a fibrous structure with a characteristic spacing of ~10 μm. Co-culture experiments demonstrated that soluble components released from the fungal substrates did not induce cytotoxicity, while low concentrations of hot-water extracts promoted cell proliferation even under serum-free conditions. Upon differentiation induction, myotube-like structures formed on all substrates. Notably, aligned myotubes were predominantly observed on the L. edodes substrate, where myotube orientation followed the intrinsic fibrous direction of the scaffold. These findings indicate that physical surface anisotropy, rather than chemical composition, governs myotube alignment. This study demonstrates a scalable, food-compatible scaffold strategy that utilizes the inherent structure of mushroom tissues, providing a sustainable approach to texture-controlled cultured meat production.
- 5 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEdible anisotropic scaffolds derived from mushroom fruiting bodies enable myotube alignment through physical processing alone
Reproducing the texture of whole-cut meat remains a major challenge in cultured meat production, largely due to the difficulty of constructing aligned muscle structures using food-compatible materials. This study proposes edible anisotropic scaffolds derived from mushroom fruiting bodies as a low-processing, animal-free platform for myotube alignment. Fruiting bodies of edible mushrooms (Pleurotus eryngii, Pleurotus ostreatus, and Lentinula edodes) were prepared using only physical slicing, autoclave sterilization, drying, and rehydration, without chemical treatments. Infrared spectroscopy confirmed that the substrates consisted of polysaccharides, proteins, and lipids typical of edible fungi. Surface analysis revealed distinct anisotropic microstructures, especially in L. edodes, exhibiting the strongest anisotropy with the presence of a fibrous structure with a characteristic spacing of ~10 μm. Co-culture experiments demonstrated that soluble components released from the fungal substrates did not induce cytotoxicity, while low concentrations of hot-water extracts promoted cell proliferation even under serum-free conditions. Upon differentiation induction, myotube-like structures formed on all substrates. Notably, aligned myotubes were predominantly observed on the L. edodes substrate, where myotube orientation followed the intrinsic fibrous direction of the scaffold. These findings indicate that physical surface anisotropy, rather than chemical composition, governs myotube alignment. This study demonstrates a scalable, food-compatible scaffold strategy that utilizes the inherent structure of mushroom tissues, providing a sustainable approach to texture-controlled cultured meat production.
- Open Access
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 24-00042
Determination of the critical electric field strength for therapeutic irreversible electroporation by using a three-dimensional cell culture model
Irreversible electroporation (IRE) is a less-invasive therapy to treat tumors by delivering short and intensive electric pulses to the tissue. The pulse settings are important factors that affect IRE outcome. In this study, we proposed a three-dimensional (3-D) cell culture model to determine the critical electric field for IRE depending on the effect of pulse parameters, particularly pulse repetition and interval, and adjuvants. Agarose gel containing fibroblasts was used as a tissue phantom. After application of electric pulses, the area that contained full of necrotized cells was quantified and compared with the distribution of the electric field estimated from a numerical analysis, so that the critical electric field strength to cause cell necrosis was determined. Ablated area increased as a function of pulse repetition, and reached a plateau at 120 pulses. When the pulse interval was extended from 100 ms to 1 s, the ablated area increased by approximately 30%. Addition of 10% DMSO and 5% ethanol also significantly increased the ablated area by 15% and 55%, respectively, indicating a reduction of the critical electric field strength. The critical electric field strength was independent of the magnitude of the applied voltage when the pulse length, interval, and the number of pulses were fixed. A longer interval and adjuvants increased the ablated area, and therefore decreased the critical electric field strength. The 3-D tissue phantom composed of agarose gel and cells was useful for examination of the IRE effect by comparing the experimentally determined necrotized region with a numerical analysis.
- 1 January 2024
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 19 (3) , 24-00042
Open AccessDetermination of the critical electric field strength for therapeutic irreversible electroporation by using a three-dimensional cell culture model
Irreversible electroporation (IRE) is a less-invasive therapy to treat tumors by delivering short and intensive electric pulses to the tissue. The pulse settings are important factors that affect IRE outcome. In this study, we proposed a three-dimensional (3-D) cell culture model to determine the critical electric field for IRE depending on the effect of pulse parameters, particularly pulse repetition and interval, and adjuvants. Agarose gel containing fibroblasts was used as a tissue phantom. After application of electric pulses, the area that contained full of necrotized cells was quantified and compared with the distribution of the electric field estimated from a numerical analysis, so that the critical electric field strength to cause cell necrosis was determined. Ablated area increased as a function of pulse repetition, and reached a plateau at 120 pulses. When the pulse interval was extended from 100 ms to 1 s, the ablated area increased by approximately 30%. Addition of 10% DMSO and 5% ethanol also significantly increased the ablated area by 15% and 55%, respectively, indicating a reduction of the critical electric field strength. The critical electric field strength was independent of the magnitude of the applied voltage when the pulse length, interval, and the number of pulses were fixed. A longer interval and adjuvants increased the ablated area, and therefore decreased the critical electric field strength. The 3-D tissue phantom composed of agarose gel and cells was useful for examination of the IRE effect by comparing the experimentally determined necrotized region with a numerical analysis.
- 28 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2480-2487
Feasibility of Concentric Electrodes in Contact Irreversible Electroporation for Superficial Lesion Treatment
Objective: Contact irreversible electroporation (IRE) is a method for ablating cells by applying electric pulses via surface electrodes in contact with a target tissue. To facilitate the application of the contact IRE to superficial lesion treatment, this study further extended the ablation depth, which had been limited to a 400-μm depth in our previous study, by using concentric electrodes. Methods: A prototype device of concentric electrodes was manufactured using a Teflon-coated copper wire inserted in a copper tube. The ablation area was experimentally determined using a tissue phantom comprising 3D cultured fibroblasts and compared with the electric field distribution obtained using numerical analyses. Results: Experiments showed that cells 540 μm from the surface of the tissue phantom were necrotized by the application of 150 pulses at 100 V. The outline of the ablation area agreed well with the contour line of 0.4 kV/cm acquired by the analyses. The ablation depth predicted for the concentric electrode using this critical electric field was 1.4 times deeper than that for the parallel electrode. For the actual application of treatment, a multiple-electrode device that bundles several pairs of concentric electrodes was developed, and confirmed that to be effective for treating wide areas with a single treatment. Conclusion: The electric field estimated by the analyses with the experimentally determined threshold confirmed that concentric electrodes could attain a deeper ablation than parallel electrodes. Significance: Using the concentric electrodes, we were able to localize ablation to specific target cells with much less damage to neighboring cells.
- 28 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2480-2487
Feasibility of Concentric Electrodes in Contact Irreversible Electroporation for Superficial Lesion Treatment
Objective: Contact irreversible electroporation (IRE) is a method for ablating cells by applying electric pulses via surface electrodes in contact with a target tissue. To facilitate the application of the contact IRE to superficial lesion treatment, this study further extended the ablation depth, which had been limited to a 400-μm depth in our previous study, by using concentric electrodes. Methods: A prototype device of concentric electrodes was manufactured using a Teflon-coated copper wire inserted in a copper tube. The ablation area was experimentally determined using a tissue phantom comprising 3D cultured fibroblasts and compared with the electric field distribution obtained using numerical analyses. Results: Experiments showed that cells 540 μm from the surface of the tissue phantom were necrotized by the application of 150 pulses at 100 V. The outline of the ablation area agreed well with the contour line of 0.4 kV/cm acquired by the analyses. The ablation depth predicted for the concentric electrode using this critical electric field was 1.4 times deeper than that for the parallel electrode. For the actual application of treatment, a multiple-electrode device that bundles several pairs of concentric electrodes was developed, and confirmed that to be effective for treating wide areas with a single treatment. Conclusion: The electric field estimated by the analyses with the experimentally determined threshold confirmed that concentric electrodes could attain a deeper ablation than parallel electrodes. Significance: Using the concentric electrodes, we were able to localize ablation to specific target cells with much less damage to neighboring cells.
- Open Access
- 21 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0262133
Application of the Taguchi method to explore a robust condition of tumor-treating field treatment
Tumor-treating fields have potential as minimally invasive cancer treatment. This study aimed to explore the optimum tumor-treating field conditions that minimize unpredicted variations in therapeutic outcomes resulting from differences in cell size and electrical properties. The electric field concentration that induces a dielectrophoretic force near the division plane of a mitotic cell was calculated by finite element analysis for 144 cases, based on different combinations of six noise factors associated with cells and four controllable factors including frequency, as determined by the Taguchi method. Changing the frequency from 200 to 400 kHz strongly increased robustness in producing a dielectrophoretic force, irrespective of noise factors. However, this frequency change reduced the force magnitude, which can be increased by simply applying a higher voltage. Based on additional simulations that considered this trade-off effect, a frequency of 300 kHz is recommended for a robust TTF treatment with allowable variations. The dielectrophoretic force was almost independent of the angle of applied electric field deviated from the most effective direction by ±20 degrees. Furthermore, increased robustness was observed for extracellular fluid with higher conductivity and permittivity. The Taguchi method was useful for identifying robust tumor-treating field therapy conditions from a considerably small number of replicated simulations.
- 21 January 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (1) , e0262133
Open AccessApplication of the Taguchi method to explore a robust condition of tumor-treating field treatment
Tumor-treating fields have potential as minimally invasive cancer treatment. This study aimed to explore the optimum tumor-treating field conditions that minimize unpredicted variations in therapeutic outcomes resulting from differences in cell size and electrical properties. The electric field concentration that induces a dielectrophoretic force near the division plane of a mitotic cell was calculated by finite element analysis for 144 cases, based on different combinations of six noise factors associated with cells and four controllable factors including frequency, as determined by the Taguchi method. Changing the frequency from 200 to 400 kHz strongly increased robustness in producing a dielectrophoretic force, irrespective of noise factors. However, this frequency change reduced the force magnitude, which can be increased by simply applying a higher voltage. Based on additional simulations that considered this trade-off effect, a frequency of 300 kHz is recommended for a robust TTF treatment with allowable variations. The dielectrophoretic force was almost independent of the angle of applied electric field deviated from the most effective direction by ±20 degrees. Furthermore, increased robustness was observed for extracellular fluid with higher conductivity and permittivity. The Taguchi method was useful for identifying robust tumor-treating field therapy conditions from a considerably small number of replicated simulations.
- Open Access
- 6 March 2019
- Published by SAGE Publications in Advances in Wound Care
- Vol. 8 (3) , 108-117
Effect of a Single Injection of Benidipine-Impregnated Biodegradable Microcarriers on Bone and Gingival Healing at the Tooth Extraction Socket
Objective: A dihydropyridine-type calcium channel blocker, benidipine (BD), is extensively used in hypertension therapy. In vitro study reported BD promoting bone metabolism. We evaluated the effect of sustained release of BD-loaded poly(lactic-co-glycolic acid) (PLGA) microcarriers on the promotion of bone and gingival healing at an extraction socket in vivo . In addition, the effect of BD on osteoblasts, osteocytes, fibroblasts, and epithelial cells was evaluated in vitro . Approach: The maxillary first molar of rats was extracted. Next, PLGA microcarriers containing BD were directly injected into the gingivobuccal fold as a single dose. After injection, bone and soft-tissue healing was histologically evaluated. Effect of BD on proliferation, migration, and gene expression of gingival and bone cell was also examined in vitro . Results: After tooth extraction, BD significantly augmented bone volume and density, and also epithelial wound healing. During in vitro studies, BD promoted significant proliferation and migration of fibroblasts and epithelial cells. Real-time RT-PCR revealed that BD upregulated messenger RNA expression of Ahsg (alpha 2-HS glycoprotein) and Csf2 (colony-stimulating factor 2) in osteoblasts. Innovation: The prevention of bone and soft-tissue reduction associated with tooth extraction has been eagerly anticipated in the field of dentistry. This study first reported the effect of BD on extraction socket healing. Conclusion: A single dose of topically administered BD-loaded PLGA microcarriers promoted bone and soft-tissue healing at the extraction site of tooth.
- 6 March 2019
- Published by SAGE Publications in Advances in Wound Care
- Vol. 8 (3) , 108-117
Open AccessEffect of a Single Injection of Benidipine-Impregnated Biodegradable Microcarriers on Bone and Gingival Healing at the Tooth Extraction Socket
Objective: A dihydropyridine-type calcium channel blocker, benidipine (BD), is extensively used in hypertension therapy. In vitro study reported BD promoting bone metabolism. We evaluated the effect of sustained release of BD-loaded poly(lactic-co-glycolic acid) (PLGA) microcarriers on the promotion of bone and gingival healing at an extraction socket in vivo . In addition, the effect of BD on osteoblasts, osteocytes, fibroblasts, and epithelial cells was evaluated in vitro . Approach: The maxillary first molar of rats was extracted. Next, PLGA microcarriers containing BD were directly injected into the gingivobuccal fold as a single dose. After injection, bone and soft-tissue healing was histologically evaluated. Effect of BD on proliferation, migration, and gene expression of gingival and bone cell was also examined in vitro . Results: After tooth extraction, BD significantly augmented bone volume and density, and also epithelial wound healing. During in vitro studies, BD promoted significant proliferation and migration of fibroblasts and epithelial cells. Real-time RT-PCR revealed that BD upregulated messenger RNA expression of Ahsg (alpha 2-HS glycoprotein) and Csf2 (colony-stimulating factor 2) in osteoblasts. Innovation: The prevention of bone and soft-tissue reduction associated with tooth extraction has been eagerly anticipated in the field of dentistry. This study first reported the effect of BD on extraction socket healing. Conclusion: A single dose of topically administered BD-loaded PLGA microcarriers promoted bone and soft-tissue healing at the extraction site of tooth.
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1G03
Development of graphene nanopore sensor for detecting single bio-molecule
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 1G03
Development of graphene nanopore sensor for detecting single bio-molecule
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 2A10
Nonthermal irreversible electroporation of biological phantoms using a micro comb-shaped electrode
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2018.30, 2A10
Nonthermal irreversible electroporation of biological phantoms using a micro comb-shaped electrode
総合学術電子ジャーナルサイト「J-STAGE」-国内で発行された学術論文全文を読むことのできる、日本最大級の総合電子ジャーナルプラットフォームです。
- 1 August 2017
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 111, 163-170
Raman microspectroscopic detection of thermal denaturation associated with irreversible electroporation
- 1 August 2017
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 111, 163-170
Raman microspectroscopic detection of thermal denaturation associated with irreversible electroporation