Daryoush Nazarpour
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daryoush Nazarpour has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Sajjad Golshannavaz
Urmia University
9 shared publications - Amin Yazdaninejadi
Department of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran, Iran
5 shared publications - Vahid Talavat
Faculty of Electrical and Computer Engineering, Urmia University, Urmia, Iran, Islamic Republic of
4 shared publications - Amir Hamidi
School of Electrical and Computer Engineering, Urmia University, Urmia Iran, Islamic Republic of
2 shared publications - Mahyar Hassanifar
Chair of Power Electronics, Kiel University, Kiel, Germany
2 shared publications - Mojtaba Beiraghi
Department of Electrical Engineering Ur.C. Islamic Azad University Urmia Iran
2 shared publications
Latest Publications
- Open Access
- 22 October 2025
- Published by Springer Nature in Research Square
Robust Design of Delay-Resilient Wide-Area Damping Controllers in Power Systems Based on Hybrid RES–ESS Actuators and 5G-Enabled PMU Streams
With the increasing deployment of renewable energy sources (RES) and energy storage systems (ESS), these units, in addition to their primary roles of generation and storage, offer significant potential for damping inter-area and low-frequency oscillations in modern power systems. By exploiting the fast dynamics of inverter-based RES and the effective inertia provided by storage systems, they can actively contribute to enhancing transient stability and improving oscillation damping. This paper proposes a robust design of delay-resilient wide-area damping controllers (WADCs) that are directly integrated into the control layer of hybrid RES–ESS units. The controller utilizes 5G-enabled phasor measurement unit (PMU) streams, ensuring reliable and low-latency wide-area signals to improve resiliency against variable delays and packet losses. The proposed structure is based on a classical power oscillation damper (POD) with adaptive gain scheduling, enabling dynamic adjustment to different delay scenarios and operating conditions. To determine the optimal parameters of the WADC, the Coronavirus Metamorphosis Optimization Algorithm (CMOA) is employed. Inspired by the transformation and mutation processes of viral evolution, CMOA ensures efficient global and local search balance and provides robust convergence under uncertainty. The effectiveness of the proposed methodology is validated on two benchmark test systems: the IEEE six-machine, three-area system for fundamental analysis and the IEEE 39-bus New England system for large-scale validation. Simulation results demonstrate that the proposed WADC effectively damps inter-area oscillations, reduces settling time, and maintains robust performance under varying delays (100–500 ms) and renewable variability. In the 6-machine system, the dominant inter-area mode shifted from an unstable eigenvalue (− 1.43% damping at 0.501 Hz) to a stable one with over 41% damping (0.652 Hz), while ITSE and ISE were reduced by more than 90%. In the 10-machine New England system, three poorly damped inter-area modes (worst case − 5.96% damping) were stabilized with damping ratios near 4.5%, alongside a reduction of error indices by more than 95%.
- 22 October 2025
- Published by Springer Nature in Research Square
Open AccessRobust Design of Delay-Resilient Wide-Area Damping Controllers in Power Systems Based on Hybrid RES–ESS Actuators and 5G-Enabled PMU Streams
With the increasing deployment of renewable energy sources (RES) and energy storage systems (ESS), these units, in addition to their primary roles of generation and storage, offer significant potential for damping inter-area and low-frequency oscillations in modern power systems. By exploiting the fast dynamics of inverter-based RES and the effective inertia provided by storage systems, they can actively contribute to enhancing transient stability and improving oscillation damping. This paper proposes a robust design of delay-resilient wide-area damping controllers (WADCs) that are directly integrated into the control layer of hybrid RES–ESS units. The controller utilizes 5G-enabled phasor measurement unit (PMU) streams, ensuring reliable and low-latency wide-area signals to improve resiliency against variable delays and packet losses. The proposed structure is based on a classical power oscillation damper (POD) with adaptive gain scheduling, enabling dynamic adjustment to different delay scenarios and operating conditions. To determine the optimal parameters of the WADC, the Coronavirus Metamorphosis Optimization Algorithm (CMOA) is employed. Inspired by the transformation and mutation processes of viral evolution, CMOA ensures efficient global and local search balance and provides robust convergence under uncertainty. The effectiveness of the proposed methodology is validated on two benchmark test systems: the IEEE six-machine, three-area system for fundamental analysis and the IEEE 39-bus New England system for large-scale validation. Simulation results demonstrate that the proposed WADC effectively damps inter-area oscillations, reduces settling time, and maintains robust performance under varying delays (100–500 ms) and renewable variability. In the 6-machine system, the dominant inter-area mode shifted from an unstable eigenvalue (− 1.43% damping at 0.501 Hz) to a stable one with over 41% damping (0.652 Hz), while ITSE and ISE were reduced by more than 90%. In the 10-machine New England system, three poorly damped inter-area modes (worst case − 5.96% damping) were stabilized with damping ratios near 4.5%, alongside a reduction of error indices by more than 95%.
- Open Access
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135315-135324
Adaptive Fuzzy Tuning of Smart Transformer for Microgrid-Utility Power Interactions
Lack of effective control over the power flow is one of the main problems in the Point of Common Coupling (PCC) of the microgrid and the main utility. To tackle this issue, this paper is on developing a confident, simple, and low-cost way for smooth and bidirectional control of power transfer between the microgrid and the main utility. The proposed approach is based on smart transformer (ST) which is an isolated high-frequency power converter that consists high-frequency step-down tap-changer transformer and three-phase to single-phase matrix converters. These converters contribute to improve the microgrid power management during grid-connected mode. For the simultaneous control of voltage and frequency, the method of Dual Virtual Quadrature Source (DVQS) with sinusoidal duty cycle is proposed to effectively adjust the switching parameters during the fault between the microgrid and the main utility. Moreover, fuzzy logic contributes to a flexible control on active and reactive power flow management. To evaluate the performance of the proposed approach, simulation studies are established on a sample system and discussed in more depth.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 135315-135324
Open AccessAdaptive Fuzzy Tuning of Smart Transformer for Microgrid-Utility Power Interactions
Lack of effective control over the power flow is one of the main problems in the Point of Common Coupling (PCC) of the microgrid and the main utility. To tackle this issue, this paper is on developing a confident, simple, and low-cost way for smooth and bidirectional control of power transfer between the microgrid and the main utility. The proposed approach is based on smart transformer (ST) which is an isolated high-frequency power converter that consists high-frequency step-down tap-changer transformer and three-phase to single-phase matrix converters. These converters contribute to improve the microgrid power management during grid-connected mode. For the simultaneous control of voltage and frequency, the method of Dual Virtual Quadrature Source (DVQS) with sinusoidal duty cycle is proposed to effectively adjust the switching parameters during the fault between the microgrid and the main utility. Moreover, fuzzy logic contributes to a flexible control on active and reactive power flow management. To evaluate the performance of the proposed approach, simulation studies are established on a sample system and discussed in more depth.
- Open Access
- 28 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 76744-76752
Protection Enhancement in Modern Distribution Networks Considering On-Load Tap Changer Operations Side-Effects
This paper shows that since high penetration level of distributed generations (DGs) makes the protection coordination complicated in active electrical grids, selectivity task among relays pairs can be easily affected by on-load tap changer (OLTC) tap position. Therefore, mitigating the side effect of OLTC tap position on relays coordination in active distribution networks is of crucial importance which should be considered in relaying process. To tackle this challenging issue, this paper presents a protection scheme based on deployment of numerical relays and low bandwidth communication links besides considering OLTC tap position. The proposed approach provides a selective scheme with individual settings for relays which are set independent from OLTC tap positions. The relays settings are obtained through the optimization process to minimize the relays tripping times. In this regard, a new logarithmic objective function is also presented to steer the relays setting toward optimal solutions with fast convergence. The feasibility and the effectiveness of the proposed formulation is tested on the IEEE 14-bus test system.
- 28 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 76744-76752
Open AccessProtection Enhancement in Modern Distribution Networks Considering On-Load Tap Changer Operations Side-Effects
This paper shows that since high penetration level of distributed generations (DGs) makes the protection coordination complicated in active electrical grids, selectivity task among relays pairs can be easily affected by on-load tap changer (OLTC) tap position. Therefore, mitigating the side effect of OLTC tap position on relays coordination in active distribution networks is of crucial importance which should be considered in relaying process. To tackle this challenging issue, this paper presents a protection scheme based on deployment of numerical relays and low bandwidth communication links besides considering OLTC tap position. The proposed approach provides a selective scheme with individual settings for relays which are set independent from OLTC tap positions. The relays settings are obtained through the optimization process to minimize the relays tripping times. In this regard, a new logarithmic objective function is also presented to steer the relays setting toward optimal solutions with fast convergence. The feasibility and the effectiveness of the proposed formulation is tested on the IEEE 14-bus test system.
- 5 September 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 707-722
Computer and experimental analysis of a reconfigurable staircase module-based multi-level inverter with fault tolerant capability
- 5 September 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 707-722
Computer and experimental analysis of a reconfigurable staircase module-based multi-level inverter with fault tolerant capability
- Open Access
- 9 March 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (14) , 10147-10196
A novel metaheuristic algorithm inspired by COVID-19 for real-parameter optimization
In this modern world, we are encountered with numerous complex and emerging problems. The metaheuristic optimization science plays a key role in many fields from medicine to engineering, design, etc. Metaheuristic algorithms inspired by nature are among the most effective and fastest optimization methods utilized to optimize different objective functions to minimize or maximize one or more specific objectives. The use of metaheuristic algorithms and their modified versions is expanding every day. However, due to the abundance and complexity of various problems in the real world, it is always necessary to select the most proper metaheuristic method; hence, there is a strong need to create new algorithms to achieve our desired goal. In this paper, a new and powerful metaheuristic algorithm, called the coronavirus metamorphosis optimization algorithm (CMOA), is proposed based on metabolism and transformation under various conditions. The proposed CMOA algorithm has been tested and implemented on the comprehensive and complex CEC2014 benchmark functions, which are functions based on real-world problems. The results of the experiments in a comparative study under the same conditions show that the CMOA is superior to the newly-developed metaheuristic algorithms including AIDO, ITGO, RFOA, SCA, CSA, CS, SOS, GWO, WOA, MFO, PSO, Jaya, CMA-ES, GSA, RW-GWO, mTLBO, MG-SCA, TOGPEAe, m-SCA, EEO and OB-L-EO, indicating the effectiveness and robustness of the CMOA algorithm as a powerful algorithm. As it was observed from the results, the CMOA provides more suitable and optimized solutions than its competitors for the problems studied. The CMOA preserves the diversity of the population and prevents trapping in local optima. The CMOA is also applied to three engineering problems including optimal design of a welded beam, a three-bar truss and a pressure vessel, showing its high potential in solving such practical problems and effectiveness in finding global optima. According to the obtained results, the CMOA is superior to its counterparts in terms of providing a more acceptable solution. Several statistical indicators are also tested using the CMOA, which demonstrates its efficiency compared to the rest of the methods. This is also highlighted that the CMOA is a stable and reliable method when employed for expert systems.
- 9 March 2023
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (14) , 10147-10196
Open AccessA novel metaheuristic algorithm inspired by COVID-19 for real-parameter optimization
In this modern world, we are encountered with numerous complex and emerging problems. The metaheuristic optimization science plays a key role in many fields from medicine to engineering, design, etc. Metaheuristic algorithms inspired by nature are among the most effective and fastest optimization methods utilized to optimize different objective functions to minimize or maximize one or more specific objectives. The use of metaheuristic algorithms and their modified versions is expanding every day. However, due to the abundance and complexity of various problems in the real world, it is always necessary to select the most proper metaheuristic method; hence, there is a strong need to create new algorithms to achieve our desired goal. In this paper, a new and powerful metaheuristic algorithm, called the coronavirus metamorphosis optimization algorithm (CMOA), is proposed based on metabolism and transformation under various conditions. The proposed CMOA algorithm has been tested and implemented on the comprehensive and complex CEC2014 benchmark functions, which are functions based on real-world problems. The results of the experiments in a comparative study under the same conditions show that the CMOA is superior to the newly-developed metaheuristic algorithms including AIDO, ITGO, RFOA, SCA, CSA, CS, SOS, GWO, WOA, MFO, PSO, Jaya, CMA-ES, GSA, RW-GWO, mTLBO, MG-SCA, TOGPEAe, m-SCA, EEO and OB-L-EO, indicating the effectiveness and robustness of the CMOA algorithm as a powerful algorithm. As it was observed from the results, the CMOA provides more suitable and optimized solutions than its competitors for the problems studied. The CMOA preserves the diversity of the population and prevents trapping in local optima. The CMOA is also applied to three engineering problems including optimal design of a welded beam, a three-bar truss and a pressure vessel, showing its high potential in solving such practical problems and effectiveness in finding global optima. According to the obtained results, the CMOA is superior to its counterparts in terms of providing a more acceptable solution. Several statistical indicators are also tested using the CMOA, which demonstrates its efficiency compared to the rest of the methods. This is also highlighted that the CMOA is a stable and reliable method when employed for expert systems.
- Open Access
- 30 October 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (12) , e13153
Data clustering based probabilistic UPFC allocation for improving power system reliability considering correlated uncertain variables
Flexible alternating-current transmission system (FACTS) devices as power electronic-based technologies have been developed to improve the performance of power systems. This paper proposes a probabilistic framework for optimal allocation of unified power flow controller (UPFC) as one of the most beneficial FACTS devices to increase the reliability of the power system. For this purpose, the expected power not served (EPNS) is considered as a reliability index that is obtained based on the summation of required load shedding in all buses during single contingencies, including transmission lines and generators outage. Power demands and wind speed are considered as uncertain input variables. In addition, the correlations among these variables are included in the proposed study method. The well-known particle swarm optimization (PSO) algorithm is used to optimize the proposed objective function. Also, the firefly algorithm (FA) is implemented to determine the total amount of load shedding for the calculation of EPNS, considering each possible generated solution by the PSO. The k-means based data clustering method (DCM) is used for probabilistic evaluation of the problem, for the first time. Also, the correlations among uncertain input variables are modeled with the Cholesky decomposition method. Extraction of statistical information of UPFC parameters for improving power system reliability in a probabilistic framework is one of the most important achievements of the proposed method. This information is very important in deciding on the UPFC sizing. In order to evaluate the effectiveness of the proposed method, the IEEE 14-bus and 30-bus test systems have been used.
- 30 October 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (12) , e13153
Open AccessData clustering based probabilistic UPFC allocation for improving power system reliability considering correlated uncertain variables
Flexible alternating-current transmission system (FACTS) devices as power electronic-based technologies have been developed to improve the performance of power systems. This paper proposes a probabilistic framework for optimal allocation of unified power flow controller (UPFC) as one of the most beneficial FACTS devices to increase the reliability of the power system. For this purpose, the expected power not served (EPNS) is considered as a reliability index that is obtained based on the summation of required load shedding in all buses during single contingencies, including transmission lines and generators outage. Power demands and wind speed are considered as uncertain input variables. In addition, the correlations among these variables are included in the proposed study method. The well-known particle swarm optimization (PSO) algorithm is used to optimize the proposed objective function. Also, the firefly algorithm (FA) is implemented to determine the total amount of load shedding for the calculation of EPNS, considering each possible generated solution by the PSO. The k-means based data clustering method (DCM) is used for probabilistic evaluation of the problem, for the first time. Also, the correlations among uncertain input variables are modeled with the Cholesky decomposition method. Extraction of statistical information of UPFC parameters for improving power system reliability in a probabilistic framework is one of the most important achievements of the proposed method. This information is very important in deciding on the UPFC sizing. In order to evaluate the effectiveness of the proposed method, the IEEE 14-bus and 30-bus test systems have been used.
- 22 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (1) , 850-861
A Modular Cascaded Multilevel Converter With High Configurability: Design, Analysis, and Optimization Study
This paper introduces a new modular cascaded multilevel inverter (MLI) which is composed of a cascaded connection of submodules (SMs). The combination of basic cells (BCs) with polarity changer H-Bridge produces the SMs, which is the basis of the introduced inverter. Owing to its high modularity, the proposed inverter can be extended to reach higher voltage levels. Hence, two extensions are suggested: 1) Extension based on cascading more BCs within each SM, and 2) Extension based on cascading more SMs. Using a set of algorithms, the magnitude of DC voltage sources is determined to synthesize the proper AC side voltage waveform. Furthermore, the proposed topology is optimized in different ways to achieve the desired purposes, such as maximizing the number of voltage levels, minimizing the number of switches and DC sources, and providing the least total standing voltage on the switches. Therefore, in each of the mentioned optimization goals, the optimal structure is obtained. A prototype of the presented MLI is defined and its performance is verified through several simulation studies in MATLAB/Simulink and experimental tests. Besides, a comprehensive comparison is made with the best performance of the existing alternatives to demonstrate the merits and superiorities of the proposed MLI.
- 22 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (1) , 850-861
A Modular Cascaded Multilevel Converter With High Configurability: Design, Analysis, and Optimization Study
This paper introduces a new modular cascaded multilevel inverter (MLI) which is composed of a cascaded connection of submodules (SMs). The combination of basic cells (BCs) with polarity changer H-Bridge produces the SMs, which is the basis of the introduced inverter. Owing to its high modularity, the proposed inverter can be extended to reach higher voltage levels. Hence, two extensions are suggested: 1) Extension based on cascading more BCs within each SM, and 2) Extension based on cascading more SMs. Using a set of algorithms, the magnitude of DC voltage sources is determined to synthesize the proper AC side voltage waveform. Furthermore, the proposed topology is optimized in different ways to achieve the desired purposes, such as maximizing the number of voltage levels, minimizing the number of switches and DC sources, and providing the least total standing voltage on the switches. Therefore, in each of the mentioned optimization goals, the optimal structure is obtained. A prototype of the presented MLI is defined and its performance is verified through several simulation studies in MATLAB/Simulink and experimental tests. Besides, a comprehensive comparison is made with the best performance of the existing alternatives to demonstrate the merits and superiorities of the proposed MLI.
- Open Access
- 12 June 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (9)
A new quasi‐resonant switched capacitor multilevel inverter with the self‐voltage balancing capability
This paper presents a new structure for a quasi‐resonant switched capacitor multilevel inverter. This structure offers multiple features of the conventional multilevel structures. Moreover, regarding the provided output voltage levels, the proposed structure exploits a new quasi‐resonant basic module which helps to diminish circuit cost and complexity using fewer power components. In the proposed structure, the balancing of capacitors voltages is achieved by series and parallel connection with the voltage source and without the need to employ a complicated control system. In order to obtain higher voltage levels at the inverter ac side, a developed H‐bridge is used in which the basic module is extended horizontally in separate cells on either side. Through a quasi‐resonant inductor deployment in the basic module, current spikes of capacitors are filtered which overwhelms decreasing of capacitor value and also lengthening the capacitor lifetime besides decreasing electromagnetic interference (EMI). Coupled with extensive simulation studies, experimental analyses are conducted to validate the performance of the proposed 17‐level inverter.
- 12 June 2020
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (9)
Open AccessA new quasi‐resonant switched capacitor multilevel inverter with the self‐voltage balancing capability
This paper presents a new structure for a quasi‐resonant switched capacitor multilevel inverter. This structure offers multiple features of the conventional multilevel structures. Moreover, regarding the provided output voltage levels, the proposed structure exploits a new quasi‐resonant basic module which helps to diminish circuit cost and complexity using fewer power components. In the proposed structure, the balancing of capacitors voltages is achieved by series and parallel connection with the voltage source and without the need to employ a complicated control system. In order to obtain higher voltage levels at the inverter ac side, a developed H‐bridge is used in which the basic module is extended horizontally in separate cells on either side. Through a quasi‐resonant inductor deployment in the basic module, current spikes of capacitors are filtered which overwhelms decreasing of capacitor value and also lengthening the capacitor lifetime besides decreasing electromagnetic interference (EMI). Coupled with extensive simulation studies, experimental analyses are conducted to validate the performance of the proposed 17‐level inverter.
- 1 January 2020
- Published by Journal of Modern Power Systems and Clean Energy in Journal of Modern Power Systems and Clean Energy
- Vol. 8 (3) , 540-548
Fast Protection Scheme for Active Distribution Networks: Breaking Chains by Utilizing Auxiliary Relays
- 1 January 2020
- Published by Journal of Modern Power Systems and Clean Energy in Journal of Modern Power Systems and Clean Energy
- Vol. 8 (3) , 540-548
Fast Protection Scheme for Active Distribution Networks: Breaking Chains by Utilizing Auxiliary Relays
- Open Access
- 18 December 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (2) , 157-170
Optimal coordination of dual‐setting directional over‐current relays in multi‐source meshed active distribution networks considering transient stability
Sustainable electrification calls the need for more efficient protection schemes. Synchronous‐based distributed generations (SBDGs) are more susceptible to power grid faults owing to their low inertia time constants. Accordingly, fault elimination faster than the associated critical clearing time (CCT) is required to prevent unintentional disconnection of SBDGs, which inevitably makes the coordination of directional over‐current relays (DOCRs) complicated than before, especially in meshed structure distribution networks (DNs). This study proposes communication assisted dual‐setting DOCRs as effective solutions for providing fast‐response protection in order to meet transient stability constraints of SBDGs in meshed active DNs. Dual‐setting DOCRs are capable of operating in both forward and reverse directions with individual settings for each direction and thus providing flexibility in the coordination process. In this regard, time domain simulation as a reliable method is conducted to calculate CCTs. Afterwards, coupled with selectivity constraints associated with dual‐setting DOCRs, transient stability constraints are all together accommodated in the optimisation process. Moreover, dual‐setting DOCRs are allowed to follow user‐defined time‐inverse characteristics which help to alleviate clearing time of faults. The approach reveals a non‐linear programming model which is tackled by seeker algorithm. Detailed numerical studies are carried out to validate the performance of the proposed approach.
- 18 December 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (2) , 157-170
Open AccessOptimal coordination of dual‐setting directional over‐current relays in multi‐source meshed active distribution networks considering transient stability
Sustainable electrification calls the need for more efficient protection schemes. Synchronous‐based distributed generations (SBDGs) are more susceptible to power grid faults owing to their low inertia time constants. Accordingly, fault elimination faster than the associated critical clearing time (CCT) is required to prevent unintentional disconnection of SBDGs, which inevitably makes the coordination of directional over‐current relays (DOCRs) complicated than before, especially in meshed structure distribution networks (DNs). This study proposes communication assisted dual‐setting DOCRs as effective solutions for providing fast‐response protection in order to meet transient stability constraints of SBDGs in meshed active DNs. Dual‐setting DOCRs are capable of operating in both forward and reverse directions with individual settings for each direction and thus providing flexibility in the coordination process. In this regard, time domain simulation as a reliable method is conducted to calculate CCTs. Afterwards, coupled with selectivity constraints associated with dual‐setting DOCRs, transient stability constraints are all together accommodated in the optimisation process. Moreover, dual‐setting DOCRs are allowed to follow user‐defined time‐inverse characteristics which help to alleviate clearing time of faults. The approach reveals a non‐linear programming model which is tackled by seeker algorithm. Detailed numerical studies are carried out to validate the performance of the proposed approach.