Seng Chee Poh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Seng Chee Poh has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Wei Wen Wong
Water Studies School of Chemistry, Monash University Clayton Victoria Australia
3 shared publications Daryl Jia Jun Lee
Faculty of Science and Marine Environment, Universiti Malaysia Terengganu, Kuala Nerus, Terengganu, Malaysia
2 shared publications- Daryl Jia Jun Lee
Research and Education on Environment for Future Sustainability (REEFS) Research Interest Group, Faculty of Science and Marine Environment Universiti Malaysia Terengganu Kuala Nerus Terengganu Malaysia
2 shared publications - Liyang Zhan
Third Institute of Oceanography Ministry of Natural Resources Xiamen China
2 shared publications Mohd Shahrul Mohd Nadzir
School of Environmental and Natural Resource Sciences, Faculty of Science and Technology Universiti Kebangsaan Malaysia Bangi Malaysia
2 shared publicationsSiti Farhain Mohd Ludin
2 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by American Geophysical Union (AGU) in Global Biogeochemical Cycles
- Vol. 40 (9)
Uncovering the Underestimated Greenhouse Gas Emissions of Hydropower Reservoirs: A Global Synthesis
Hydropower reservoirs, long considered as a clean energy solution, are increasingly recognized as major greenhouse gas (GHG) emissions hotspots. However, over 97% of these hydropower reservoirs remain unmonitored, creating major uncertainties in global GHG budgets. Here, machine learning models were employed to predict GHG fluxes from hydropower reservoirs lacking reported direct GHG measurements using 67 widely accessible environmental predictors covering climate, land use, soil properties, geology, and topography. The predicted GHG fluxes revealed marked spatiotemporal heterogeneity, characterized by distinct monthly variability and emission hotspots predominantly concentrated in tropical and arid zones, particularly across Africa. Moreover, scaling the predictions to 5,293 unmonitored hydropower reservoirs yielded total emissions of 304 ± 37 Tg CO 2 eq year −1 , enabling a more geographically representative assessment of global reservoir GHG emissions. Methane notably dominates emissions (55.3%), followed by carbon dioxide (41.3%) and nitrous oxide (3.4%), with the latter often overlooked but gaining relevance during increasing eutrophication. In addition, our gas‐specific models identified temperature‐related variables as the primary drivers of GHG dynamics, emphasizing the central role of thermal regimes, especially in African reservoirs. Our findings call for a re‐evaluation of the climate costs of hydropower and suggest that future warming may further amplify reservoir‐based GHG emissions. The predictive capacity of our models provides a scalable tool for refining global GHG inventories and guiding low‐carbon hydropower development under a changing climate.
- 3 September 2026
- Published by American Geophysical Union (AGU) in Global Biogeochemical Cycles
- Vol. 40 (9)
Open AccessUncovering the Underestimated Greenhouse Gas Emissions of Hydropower Reservoirs: A Global Synthesis
Hydropower reservoirs, long considered as a clean energy solution, are increasingly recognized as major greenhouse gas (GHG) emissions hotspots. However, over 97% of these hydropower reservoirs remain unmonitored, creating major uncertainties in global GHG budgets. Here, machine learning models were employed to predict GHG fluxes from hydropower reservoirs lacking reported direct GHG measurements using 67 widely accessible environmental predictors covering climate, land use, soil properties, geology, and topography. The predicted GHG fluxes revealed marked spatiotemporal heterogeneity, characterized by distinct monthly variability and emission hotspots predominantly concentrated in tropical and arid zones, particularly across Africa. Moreover, scaling the predictions to 5,293 unmonitored hydropower reservoirs yielded total emissions of 304 ± 37 Tg CO 2 eq year −1 , enabling a more geographically representative assessment of global reservoir GHG emissions. Methane notably dominates emissions (55.3%), followed by carbon dioxide (41.3%) and nitrous oxide (3.4%), with the latter often overlooked but gaining relevance during increasing eutrophication. In addition, our gas‐specific models identified temperature‐related variables as the primary drivers of GHG dynamics, emphasizing the central role of thermal regimes, especially in African reservoirs. Our findings call for a re‐evaluation of the climate costs of hydropower and suggest that future warming may further amplify reservoir‐based GHG emissions. The predictive capacity of our models provides a scalable tool for refining global GHG inventories and guiding low‐carbon hydropower development under a changing climate.
- Open Access
- 13 March 2026
- Published by Copernicus GmbH
A cost-effective rock sample unit for quality control and intercomparison of 222Rn measurements
Reliable radon-222 measurements are essential for a wide range of hydrological, geological, and environmental applications, including the study of surface water - groundwater interactions and the quantification of groundwater discharge. Despite the widespread use of 222Rn detectors, routine verification of instrument performance and measurement stability remains limited, particularly in laboratories with constrained financial and technical resources. This study presents the development and evaluation of a cost-effective rock sample unit designed to support quality control, calibration checks, and inter-laboratory comparison of 222Rn measurements.The system is based on acidic plutonic igneous rock purchased from commercial suppliers, selected for their naturally elevated and stable 222Rn production. The rocks were enclosed in a simple, airtight container assembled using readily available components, including a standard garden filter and plastic tubing. This configuration allows 222Rn generated within the rock matrix to accumulate in a closed volume and be circulated through commonly used 222Rn detectors without the need for specialized or commercial equipment. Equal amounts of material were placed in each rock sample unit, which were then sealed and stored for 21 days to allow 222Rn to reach secular equilibrium with its parent radionuclides. Initial characterization of the rock units was performed at the IAEA Isotope Hydrology laboratory. Each unit was analysed three times using a standardized protocol consisting of six measurement cycles of 30 minutes each. Measurements were conducted using RAD7 and RAD8 222Rn detectors from Durridge, which are widely applied in environmental and hydrological studies. The results demonstrated stable and reproducible 222Rn concentrations across repeated measurements, confirming the suitability of the rock units as reference sources for quality control purposes.Following this initial validation, the previously measured rock sample units were distributed to participating laboratories in Argentina, France, Malaysia, and Morocco. Each laboratory applied the same measurement protocol and used their routinely operated 222Rn detectors (RAD7 and RAD8).To support the interpretation of the observed variability, contextual information was considered, including the age of the instrument, the date of last recalibration, the intensity of use, the type of water typically analysed (saline or non-saline; surface water or groundwater), and the range of 222Rn concentrations normally encountered. This approach enabled the assessment of the significance of deviations under different operating conditions and allowed the evaluation of the robustness of measurements obtained with calibrated versus non-calibrated instruments.This exercise showed that even simple comparison of 222Rn responses obtained from the rock units provides valuable insight into the performance of the instrument and detect the potential measurement drift related to the lack of calibration. The results demonstrate that these cost-effective rock sample units represent a practical and accessible tool for strengthening 222Rn measurement quality assurance. Their simplicity, low resource requirements, and reproducibility make them particularly suitable for routine checks, contributing to the improved comparability of 222Rn data.
- 13 March 2026
- Published by Copernicus GmbH
Open AccessA cost-effective rock sample unit for quality control and intercomparison of 222Rn measurements
Reliable radon-222 measurements are essential for a wide range of hydrological, geological, and environmental applications, including the study of surface water - groundwater interactions and the quantification of groundwater discharge. Despite the widespread use of 222Rn detectors, routine verification of instrument performance and measurement stability remains limited, particularly in laboratories with constrained financial and technical resources. This study presents the development and evaluation of a cost-effective rock sample unit designed to support quality control, calibration checks, and inter-laboratory comparison of 222Rn measurements.The system is based on acidic plutonic igneous rock purchased from commercial suppliers, selected for their naturally elevated and stable 222Rn production. The rocks were enclosed in a simple, airtight container assembled using readily available components, including a standard garden filter and plastic tubing. This configuration allows 222Rn generated within the rock matrix to accumulate in a closed volume and be circulated through commonly used 222Rn detectors without the need for specialized or commercial equipment. Equal amounts of material were placed in each rock sample unit, which were then sealed and stored for 21 days to allow 222Rn to reach secular equilibrium with its parent radionuclides. Initial characterization of the rock units was performed at the IAEA Isotope Hydrology laboratory. Each unit was analysed three times using a standardized protocol consisting of six measurement cycles of 30 minutes each. Measurements were conducted using RAD7 and RAD8 222Rn detectors from Durridge, which are widely applied in environmental and hydrological studies. The results demonstrated stable and reproducible 222Rn concentrations across repeated measurements, confirming the suitability of the rock units as reference sources for quality control purposes.Following this initial validation, the previously measured rock sample units were distributed to participating laboratories in Argentina, France, Malaysia, and Morocco. Each laboratory applied the same measurement protocol and used their routinely operated 222Rn detectors (RAD7 and RAD8).To support the interpretation of the observed variability, contextual information was considered, including the age of the instrument, the date of last recalibration, the intensity of use, the type of water typically analysed (saline or non-saline; surface water or groundwater), and the range of 222Rn concentrations normally encountered. This approach enabled the assessment of the significance of deviations under different operating conditions and allowed the evaluation of the robustness of measurements obtained with calibrated versus non-calibrated instruments.This exercise showed that even simple comparison of 222Rn responses obtained from the rock units provides valuable insight into the performance of the instrument and detect the potential measurement drift related to the lack of calibration. The results demonstrate that these cost-effective rock sample units represent a practical and accessible tool for strengthening 222Rn measurement quality assurance. Their simplicity, low resource requirements, and reproducibility make them particularly suitable for routine checks, contributing to the improved comparability of 222Rn data.
- 31 October 2025
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 20 (10) , 2021-2038
THE IMPACT OF THERMAL STRATIFICATION ON NUTRIENT AND GREENHOUSE GAS DISTRIBUTION IN A DEEP TROPICAL RESERVOIR
This study examines thermal stratification in Kenyir reservoir using data from f ive sampling campaigns between February and November 2018. Field and lab analysis were carried out to examine water temperature profiles, thermocline parameters, lake number, Schmidt stability, dissolved oxygen, nutrients, and greenhouse gases. Results reveal that stratification persisted throughout the study period, with signs of epilimnetic mixing observed in February and November 2018. CO2 and CH4 median concentrations during the dry period were 362 μM and 1.8 μM, higher than in the wet period (175 μM and 1.2 μM). Greenhouse gas concentrations were highest at the bottom layer, with CO2 and CH4 levels of 573 μM and 379 μM, respectively, compared to the thermocline (373 μM and 2.6 μM) and surface (179 μM and 0.8 μM). The dissolved inorganic nitrogen and phosphorus concentrations averaged 184 ± 247 μg/L and 7 ± 4 μg/L, respectively, lower than the global average. This study highlights the influence of stratification on greenhouse gas dynamics and nutrient distributions, offering insights for local energy authorities to mitigate climate change impacts. Understanding factors that destabilise stratification can help manage the reservoir’s carbon footprint and optimise hydropower sustainability.
- 31 October 2025
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 20 (10) , 2021-2038
THE IMPACT OF THERMAL STRATIFICATION ON NUTRIENT AND GREENHOUSE GAS DISTRIBUTION IN A DEEP TROPICAL RESERVOIR
This study examines thermal stratification in Kenyir reservoir using data from f ive sampling campaigns between February and November 2018. Field and lab analysis were carried out to examine water temperature profiles, thermocline parameters, lake number, Schmidt stability, dissolved oxygen, nutrients, and greenhouse gases. Results reveal that stratification persisted throughout the study period, with signs of epilimnetic mixing observed in February and November 2018. CO2 and CH4 median concentrations during the dry period were 362 μM and 1.8 μM, higher than in the wet period (175 μM and 1.2 μM). Greenhouse gas concentrations were highest at the bottom layer, with CO2 and CH4 levels of 573 μM and 379 μM, respectively, compared to the thermocline (373 μM and 2.6 μM) and surface (179 μM and 0.8 μM). The dissolved inorganic nitrogen and phosphorus concentrations averaged 184 ± 247 μg/L and 7 ± 4 μg/L, respectively, lower than the global average. This study highlights the influence of stratification on greenhouse gas dynamics and nutrient distributions, offering insights for local energy authorities to mitigate climate change impacts. Understanding factors that destabilise stratification can help manage the reservoir’s carbon footprint and optimise hydropower sustainability.
- Open Access
An assessment of CO2 and CH4 emissions in a tropical river: from the Kenyir Reservoir to the estuary
This study investigates the spatial and seasonal variations in CO2 and CH4 emissions from the Kenyir hydropower reservoir and its downstream Terengganu River system in Malaysia. Understanding these variations is crucial for assessing whether the greenhouse gas (GHG) budget for this aquatic continuum significantly contributes to global emissions. Malaysia’s distinct monsoonal climate presents a unique opportunity to explore the influence of seasonal hydrological changes on GHG emission dynamics in inland waters. Five sampling campaigns were performed at the reservoir to investigate this, involving three longitudinal surveys from the reservoir downstream along the Terengganu River, and two time-series samplings at the estuary between November 2017 and August 2019. Our findings reveal that GHG emissions from the Kenyir Reservoir are notably higher during the wet season (97 mmol CO2 m−2 d−1 and 2 mmol CH4 m−2 d−1) than during the dry season (54 mmol CO2 m−2 d−1 and 0.8 mmol CH4 m−2 d−1). This increase coincides with increased wind speed and potential surface mixing during the wet season. Despite operating since 1985, the Kenyir Reservoir’s total GHG emissions remain high compared to other global reservoirs, likely due to its tropical location and high organic carbon content. Elevated GHG emissions were recorded along the Terengganu River, near the dam discharge outlets, with gradual reductions observed downstream. Despite the estuary’s smaller surface area, more GHGs are emitted there than in the river. Overall, the Terengganu River catchment emits approximately 572 Gg CO2-equivalent annually, with the Kenyir Reservoir accounting for the majority (94%). The river and the estuary contribute 0.5% and 5.5%, respectively. This study highlights the substantial role of tropical hydropower reservoirs and their downstream river networks in the global GHG budget, emphasizing the need for further investigation into the factors influencing GHG dynamics in tropical river systems.
Open AccessAn assessment of CO2 and CH4 emissions in a tropical river: from the Kenyir Reservoir to the estuary
This study investigates the spatial and seasonal variations in CO2 and CH4 emissions from the Kenyir hydropower reservoir and its downstream Terengganu River system in Malaysia. Understanding these variations is crucial for assessing whether the greenhouse gas (GHG) budget for this aquatic continuum significantly contributes to global emissions. Malaysia’s distinct monsoonal climate presents a unique opportunity to explore the influence of seasonal hydrological changes on GHG emission dynamics in inland waters. Five sampling campaigns were performed at the reservoir to investigate this, involving three longitudinal surveys from the reservoir downstream along the Terengganu River, and two time-series samplings at the estuary between November 2017 and August 2019. Our findings reveal that GHG emissions from the Kenyir Reservoir are notably higher during the wet season (97 mmol CO2 m−2 d−1 and 2 mmol CH4 m−2 d−1) than during the dry season (54 mmol CO2 m−2 d−1 and 0.8 mmol CH4 m−2 d−1). This increase coincides with increased wind speed and potential surface mixing during the wet season. Despite operating since 1985, the Kenyir Reservoir’s total GHG emissions remain high compared to other global reservoirs, likely due to its tropical location and high organic carbon content. Elevated GHG emissions were recorded along the Terengganu River, near the dam discharge outlets, with gradual reductions observed downstream. Despite the estuary’s smaller surface area, more GHGs are emitted there than in the river. Overall, the Terengganu River catchment emits approximately 572 Gg CO2-equivalent annually, with the Kenyir Reservoir accounting for the majority (94%). The river and the estuary contribute 0.5% and 5.5%, respectively. This study highlights the substantial role of tropical hydropower reservoirs and their downstream river networks in the global GHG budget, emphasizing the need for further investigation into the factors influencing GHG dynamics in tropical river systems.
- Open Access
- 24 October 2023
- Published by Springer Nature in Research Square
The Effect of Floating Chamber Design on Co2 Flux Measurements
The floating chamber is valued for its simplicity, affordability, and adaptability for widespread use in measuring diffusive greenhouse gases flux from surface water, although its effectiveness may vary based on its chamber design. This study investigates the effect of chamber insulation on gas flux accumulation. Our findings reveal that non-insulated chambers experienced greater solar heating effects in their headspace, with a 20% deviation from the targetted water temperature. In contrast, insulated chambers showed less than 1% temperature difference with ambient condition. Solar-induced heating of the chamber walls increased the internal temperature, leading to an overestimation of greenhouse gas fluxes. The developed floating chambers were tested at a hydropower reservoir in Terengganu, Malaysia. Results from two distinct seasonal sampling campaigns at three sites demonstrate that CO2 fluxes during the wet season (45 mmol m-2d-1) were almost three times higher compared to the dry season (16 mmol m-2d-1).
- 24 October 2023
- Published by Springer Nature in Research Square
Open AccessThe Effect of Floating Chamber Design on Co2 Flux Measurements
The floating chamber is valued for its simplicity, affordability, and adaptability for widespread use in measuring diffusive greenhouse gases flux from surface water, although its effectiveness may vary based on its chamber design. This study investigates the effect of chamber insulation on gas flux accumulation. Our findings reveal that non-insulated chambers experienced greater solar heating effects in their headspace, with a 20% deviation from the targetted water temperature. In contrast, insulated chambers showed less than 1% temperature difference with ambient condition. Solar-induced heating of the chamber walls increased the internal temperature, leading to an overestimation of greenhouse gas fluxes. The developed floating chambers were tested at a hydropower reservoir in Terengganu, Malaysia. Results from two distinct seasonal sampling campaigns at three sites demonstrate that CO2 fluxes during the wet season (45 mmol m-2d-1) were almost three times higher compared to the dry season (16 mmol m-2d-1).
- 31 July 2023
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 18 (7) , 67-86
METAL VARIATIONS IN NOTCHED THREADFIN BREAM FROM NEARSHORE AND OPEN WATER AREAS OF TERENGGANU
- 31 July 2023
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 18 (7) , 67-86
METAL VARIATIONS IN NOTCHED THREADFIN BREAM FROM NEARSHORE AND OPEN WATER AREAS OF TERENGGANU
- Open Access
- 30 January 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (6)
Boundary exchange completes the marine Pb cycle jigsaw
Material fluxes at the land–ocean interface impact seawater composition and global cycling of elements. However, most attention has been focused on the fluvial dissolved fluxes. For elements like lead (Pb), whose fluvial particulate flux into the ocean is two orders of magnitude higher than the dissolved counterpart, the role of particulates in elemental cycling is potentially important but currently less appreciated. Using both chemical analyses on samples collected from around equatorial Southeast Asia and model simulations, we show that particulate-dissolved exchange is an important mechanism controlling the concentration and isotopic composition of dissolved Pb in the ocean. Our model indicates that Pb contributed from particulate-dissolved exchange at ocean boundaries is larger than, or at least comparable to, other major Pb sources to the seawater before the Anthropocene, when the anthropogenic Pb was absent. Our work highlights the importance of boundary exchange in understanding marine element cycling and weathering-climate feedback.
- 30 January 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (6)
Open AccessBoundary exchange completes the marine Pb cycle jigsaw
Material fluxes at the land–ocean interface impact seawater composition and global cycling of elements. However, most attention has been focused on the fluvial dissolved fluxes. For elements like lead (Pb), whose fluvial particulate flux into the ocean is two orders of magnitude higher than the dissolved counterpart, the role of particulates in elemental cycling is potentially important but currently less appreciated. Using both chemical analyses on samples collected from around equatorial Southeast Asia and model simulations, we show that particulate-dissolved exchange is an important mechanism controlling the concentration and isotopic composition of dissolved Pb in the ocean. Our model indicates that Pb contributed from particulate-dissolved exchange at ocean boundaries is larger than, or at least comparable to, other major Pb sources to the seawater before the Anthropocene, when the anthropogenic Pb was absent. Our work highlights the importance of boundary exchange in understanding marine element cycling and weathering-climate feedback.
- 27 December 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 195 (1) , 1-12
Soil nutrient distribution and plant nutrient status in a mangrove stand adjacent to an aquaculture farm
- 27 December 2022
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 195 (1) , 1-12
Soil nutrient distribution and plant nutrient status in a mangrove stand adjacent to an aquaculture farm
- 12 July 2022
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 20 (8) , 500-513
Design and optimization of wireless in‐situ sensor coupled with gas–water equilibrators for continuous pCO2 measurement in aquatic environments
Affordable, highly precise, and accurate CO2 sensor is a prerequisite for more extensive CO2 measurements in various environmental settings, and thus more accurate local and global carbon budgets. Here, we propose the use of an autonomous system for the detection of CO2 concentration (mole fraction), appropriate for inland freshwater and eutrophic coastal environments. We describe the construction of a CO2 sensing device (SIPCO2‐II) using off‐the‐shelf commercial products that integrate wireless communication capability. We also report the proof of concept of two newly designed gas–water equilibrators (GWEs) for in‐situ CO2 monitoring to be used with SIPCO2‐II. The performance of the SIPCO2‐II is evaluated in detail, providing information on the sensor sensitivity, detection limit and stability, and comparing these to a commercially available CO2 analyzer (LGR 915‐0011; Los Gatos Research). Comparison results demonstrate good agreement between the two devices with the root mean square error of 5%. The accuracy and precision of SIPCO2‐II against CO2 reference gases are evaluated and values are within 99–104% recovery and 0.9–3 ppm, respectively. The GWEs which comprised either a semi‐passive floater (free‐drifting float equilibrator; FDFE) or a hybrid showerhead‐marble equilibrator (SME) are tested in the laboratory and in the environment. Overall, the SME outperforms FDFE in terms of response time (4 vs. 16 min). The FDFE can cover larger survey areas with lower cost, due to its semi‐passive feature that allows it to drift with water current. The outcome of our study provides an alternative to budget‐constrained CO2 monitoring regimes without compromising the accuracy and precision of the measurements.
- 12 July 2022
- Published by Wiley in Limnology and Oceanography: Methods
- Vol. 20 (8) , 500-513
Design and optimization of wireless in‐situ sensor coupled with gas–water equilibrators for continuous pCO2 measurement in aquatic environments
Affordable, highly precise, and accurate CO2 sensor is a prerequisite for more extensive CO2 measurements in various environmental settings, and thus more accurate local and global carbon budgets. Here, we propose the use of an autonomous system for the detection of CO2 concentration (mole fraction), appropriate for inland freshwater and eutrophic coastal environments. We describe the construction of a CO2 sensing device (SIPCO2‐II) using off‐the‐shelf commercial products that integrate wireless communication capability. We also report the proof of concept of two newly designed gas–water equilibrators (GWEs) for in‐situ CO2 monitoring to be used with SIPCO2‐II. The performance of the SIPCO2‐II is evaluated in detail, providing information on the sensor sensitivity, detection limit and stability, and comparing these to a commercially available CO2 analyzer (LGR 915‐0011; Los Gatos Research). Comparison results demonstrate good agreement between the two devices with the root mean square error of 5%. The accuracy and precision of SIPCO2‐II against CO2 reference gases are evaluated and values are within 99–104% recovery and 0.9–3 ppm, respectively. The GWEs which comprised either a semi‐passive floater (free‐drifting float equilibrator; FDFE) or a hybrid showerhead‐marble equilibrator (SME) are tested in the laboratory and in the environment. Overall, the SME outperforms FDFE in terms of response time (4 vs. 16 min). The FDFE can cover larger survey areas with lower cost, due to its semi‐passive feature that allows it to drift with water current. The outcome of our study provides an alternative to budget‐constrained CO2 monitoring regimes without compromising the accuracy and precision of the measurements.
- Open Access
- 30 September 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 8 (10) , 765
Underway Measurement of Dissolved Inorganic Carbon (DIC) in Estuarine Waters
Dissolved inorganic carbon (DIC) is an important parameter of the marine carbonate system. Underway analyses of DIC are required to describe spatial and temporal changes of DIC in marine systems. In this study, we developed a microvolume flow detection method for the underway determination of DIC in marine waters, using gas-diffusion flow analysis in conjunction with electrical conductivity (EC) measurement. Only an acid carrier reagent (0.2 mol.L−1) and an ultrapure water acceptor are required for the DIC monitoring system. In this system, a sampling loop (100 µL) is used to quantify the injection sample volume, allowing micro-sample volume detection. The water sample reacts with the acid reagent to convert carbonate and bicarbonate species into CO2. The water sample is then carried into a gas-diffusion assembly, where the CO2 diffuses from the sampling stream into the acceptor stream. CO2 in the acceptor is detected subsequently by an electrical conductivity. The limit of DIC detection using ultrapure water is 0.16 mM. A good repeatability is obtained, with a relative standard deviation (RSD) of 0.56% (1 mM, n = 21). The time interval for detecting one sample is 5 min. During the observation period, measurements can be switched between standard solutions and water samples automatically. Accuracy and precision of the instrument is sufficient for the underway observation of marine DIC in estuarine waters.
- 30 September 2020
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 8 (10) , 765
Open AccessUnderway Measurement of Dissolved Inorganic Carbon (DIC) in Estuarine Waters
Dissolved inorganic carbon (DIC) is an important parameter of the marine carbonate system. Underway analyses of DIC are required to describe spatial and temporal changes of DIC in marine systems. In this study, we developed a microvolume flow detection method for the underway determination of DIC in marine waters, using gas-diffusion flow analysis in conjunction with electrical conductivity (EC) measurement. Only an acid carrier reagent (0.2 mol.L−1) and an ultrapure water acceptor are required for the DIC monitoring system. In this system, a sampling loop (100 µL) is used to quantify the injection sample volume, allowing micro-sample volume detection. The water sample reacts with the acid reagent to convert carbonate and bicarbonate species into CO2. The water sample is then carried into a gas-diffusion assembly, where the CO2 diffuses from the sampling stream into the acceptor stream. CO2 in the acceptor is detected subsequently by an electrical conductivity. The limit of DIC detection using ultrapure water is 0.16 mM. A good repeatability is obtained, with a relative standard deviation (RSD) of 0.56% (1 mM, n = 21). The time interval for detecting one sample is 5 min. During the observation period, measurements can be switched between standard solutions and water samples automatically. Accuracy and precision of the instrument is sufficient for the underway observation of marine DIC in estuarine waters.