MMMarcel Müller

Marcel Müller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marcel Müller has a total of 116 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Super-Resolution Optical Sectioning Microscopy Visualizes Nanopores in the Plasma Membrane of Endothelial Cells in situ

    by Jasmin C. Schürstedt-Seher, Henning Ortkrass, Annika Kiel, Sylvia M. Steinecker, Wolfgang Hübner, Angela Kralemann-Köhler, Laureen P. Helweg, Marcel Müller, Jakob Wessendorf, Femke Testroet, et al.

    The ultrastructure of endothelial cells (ECs) “ in situ ” is of great interest due to their involvement in many physiological processes. In some organs, these cells form transcellular pores or fenestrae, allowing for the rapid exchange of molecules between blood and interstitium. Despite their importance, no optical images of these dynamic morphological structures have yet been acquired in situ . Major obstacles to their in-situ imaging are the lack of specifical labels for fenestrae and their size well below the optical diffraction limit. Here, we report how we have overcome these challenges and managed to visualize the EC ultrastructure in situ in 25 µm thick liver sections. To enable this, a lipophilic, fluorescent membrane dye was infused into the portal vein of murine livers to stain the sinusoidal ECs before the organ was harvested. Tissue sections were subsequently imaged using a novel, super-resolution optical-sectioning structured illumination microscope (OS-SIM), providing approx. 170 nm spatial resolution with significantly faster image acquisition compared to confocal microscopy.

  • Open Access

    Enhanced 2D structured illumination microscopy: super-resolution with optical sectioning and reduced reconstruction artifacts

    by Sylvia Marie Steinecker, Henning Ortkrass, Jasmin Celine Schürstedt-Seher, Annika Kiel, Angela Kralemann-Köhler, Jan Schulte Am Esch, Thomas Huser, Marcel Müller

    Structured Illumination Microscopy (SIM) provides imaging with spatial super-resolution, as well as optical sectioning capability, without relying on specialized fluorescent dyes. 2D and 3D variants of this method exist, but most bespoke implementations are 2D-SIM, because it is easier to realize and modify than 3D-SIM. 2D-SIM systems, however, often experience reconstruction artifacts, especially when pushing for high lateral spatial resolution in thicker samples. We present enhanced 2D-SIM , an approach to 2D-SIM where both, coarse patterns optimized for removing out-of-focus background, and fine patterns optimized for resolution improvement beyond the diffraction limit are used. In combination, this achieves 2D-SIM reconstructions with high contrast, spatial super-resolution, and significantly reduced reconstruction artifacts. We present the theoretical framework of this technique, and provide enhanced 2D-SIM imaging results of liver sinusoidal endothelial cells stained with fluorophores emitting at visible and near-infrared wavelengths. Quantitative comparisons of power spectral distribution and image resolution are provided.


  • Super-resolution structured illumination microscopy of cellular nanopores using near-infrared fluorescent probes

    by Sylvia Marie Steinecker, Henning Ortkrass, Marcel Müller, Jasmin Celine Schürstedt-Seher, Surjendu Bikash Dutta, Angela Krahlemann-Köhler, Annika Kiel, Sönke Baumann, Gerhard Holst, Jan Schulte Am Esch, et al.

    Currently, super-resolution optical microscopy is mostly conducted with fluorophores that are excited and that emit in the visible part of the electromagnetic spectrum. Extending this range to the near-infrared (NIR) and even the shortwave-infrared (SWIR) part of the spectrum is highly desirable, because light in this wavelength range is less hazardous for live imaging and can penetrate much deeper into tissue. Here, we detail our development of a novel super-resolution structured illumination microscope that is purpose-built for imaging in the NIR wavelength range. Structured illumination via laser beam interference is accomplished by splitting the excitation light along two arms of a Michelson interferometer. Arbitrary illumination angles and a wide range of pattern spacings can be obtained by controlling a two-axis galvanometric mirror. Phase shifts of the pattern are accomplished by changing the angle of an anti-reflection-coated planoparallel glass plate inserted in one arm of the interferometer. Fluorescence is detected using a NIR-enhanced 26 Megapixel scientific Complementary Metal-Oxide-Semiconductor (sCMOS) camera. We characterize this system by imaging fluorescent beads with a diameter below the diffraction limit, and demonstrate its suitability for biological imaging by resolving cellular nanopores in the plasma membrane of liver sinusoidal endothelial cells.


  • Fast and Artifact-Free Excitation Multiplexing Using Synchronized Image Scanning

    by Ezra Bruggeman, Robin Van Den Eynde, Baptiste Amouroux, Tom Venneman, Pieter Vanden Berghe, Marcel Müller, Wim Vandenberg, Peter Dedecker

    Multicolor fluorescence microscopy is an essential tool to visualize structures and dynamics in the life and materials sciences. However, the near-simultaneous acquisition of labels differing in excitation spectrum is difficult and renders such measurements prone to artifacts. We present a simple strategy to provide quasi-simultaneous fluorescence imaging with multiple excitation wavelengths by using an optical element to displace the sample image on the sensor at a rate that is much faster than the image acquisition rate and synchronizing this with the illumination. The emission elicited by the different wavelengths can then be encoded into the point-spread function of the imaging or visualized as multiple distinct images. In doing so, our approach can eliminate or mitigate artifacts caused by temporal aliasing in conventional sequential imaging. We demonstrate the use of our system to uncover hidden emissive states in single quantum dots and for the imaging of Ca2+ signaling in neurons.

  • Open Access

    High sensitivity cameras can lower spatial resolution in high-resolution optical microscopy

    by Henning Ortkrass, Marcel Müller, Anders Kokkvoll Engdahl, Gerhard Holst, Thomas Huser

    High-resolution optical fluorescence microscopies and, in particular, super-resolution fluorescence microscopy, are rapidly adopting highly sensitive cameras as their referred photodetectors. Camera-based parallel detection facilitates high-speed live cell imaging with the highest spatial resolution. Here, we show that the drive to use ever more sensitive, photon-counting image sensors in cameras can, however, have detrimental effects on spatial resolution that many researchers are not aware of. Typical parameters which influence the selection of image sensors are pixel size, quantum efficiency, signal-to-noise performance, dynamic range, and frame rate of the sensor. A parameter that is, however, often overlooked, is the sensor’s modulation transfer function (MTF). We have determined the wavelength-specific MTF of front- and back-illuminated image sensors and evaluated how it affects the spatial resolution that can be achieved in high fluorescence microscopy modalities. We find significant differences in image sensor performance for sensors that cause the resulting spatial resolution to vary with up to 28%. This result shows that the choice of image sensor has significant impact on the imaging performance of all camera-based optical microscopy modalities.

  • Open Access

    Evaluation of Swin Transformer and knowledge transfer for denoising of super-resolution structured illumination microscopy data

    by Zafran Hussain Shah, Marcel Müller, Wolfgang Hübner, Tung-Cheng Wang, Daniel Telman, Thomas Huser, Wolfram Schenck

    Background: Convolutional neural network (CNN)–based methods have shown excellent performance in denoising and reconstruction of super-resolved structured illumination microscopy (SR-SIM) data. Therefore, CNN-based architectures have been the focus of existing studies. However, Swin Transformer, an alternative and recently proposed deep learning–based image restoration architecture, has not been fully investigated for denoising SR-SIM images. Furthermore, it has not been fully explored how well transfer learning strategies work for denoising SR-SIM images with different noise characteristics and recorded cell structures for these different types of deep learning–based methods. Currently, the scarcity of publicly available SR-SIM datasets limits the exploration of the performance and generalization capabilities of deep learning methods. Results: In this work, we present SwinT-fairSIM, a novel method based on the Swin Transformer for restoring SR-SIM images with a low signal-to-noise ratio. The experimental results show that SwinT-fairSIM outperforms previous CNN-based denoising methods. Furthermore, as a second contribution, two types of transfer learning—namely, direct transfer and fine-tuning—were benchmarked in combination with SwinT-fairSIM and CNN-based methods for denoising SR-SIM data. Direct transfer did not prove to be a viable strategy, but fine-tuning produced results comparable to conventional training from scratch while saving computational time and potentially reducing the amount of training data required. As a third contribution, we publish four datasets of raw SIM images and already reconstructed SR-SIM images. These datasets cover two different types of cell structures, tubulin filaments and vesicle structures. Different noise levels are available for the tubulin filaments. Conclusion: The SwinT-fairSIM method is well suited for denoising SR-SIM images. By fine-tuning, already trained models can be easily adapted to different noise characteristics and cell structures. Furthermore, the provided datasets are structured in a way that the research community can readily use them for research on denoising, super-resolution, and transfer learning strategies.


  • Open Access

    Fast and artifact-free excitation multiplexing using synchronized image scanning

    by Ezra Bruggeman, Robin Van Den Eynde, Baptiste Amouroux, Tom Venneman, Pieter Vanden Berghe, Marcel Müller, Wim Vandenberg, Peter Dedecker

    We present the Resonator, a simple optical device that provides quasi-simultaneous fluorescence imaging with multiple excitation wavelengths. The device uses a resonant scanning mirror to periodically displace the sample image on a camera sensor at a rate that is much faster than the image acquisition rate. The excitation light is synchronized with the scanner motion to create two laterally shifted copies of the image, each containing the fluorescence excited by a single wavelength. The additional information is then encoded either into the point-spread function of the imaging or as multiple distinct images. Since this multiplexing is performed at very high rates, our design can eliminate or mitigate artifacts caused by temporal aliasing in conventional sequential imaging. We demonstrate the use of our system for the monitoring of fast light-induced dynamics in single quantum dots and for the imaging of Ca 2+ signalling in hippocampal neurons.

  • Dual color DMD-SIM by temperature-controlled laser wavelength matching

    by Mario Lachetta, Gerd Wiebusch, Wolfgang Hübner, Jan Schulte Am Esch, Thomas Huser, Marcel Müller

    Structured illumination microscopy (SIM) is a fast and gentle super-resolution fluorescence imaging technique, featuring live-cell compatible excitation light levels and high imaging speeds. To achieve SIM, spatial modulation of the fluorescence excitation light is employed. This is typically achieved by interfering coherent laser beams in the sample plane, which are often created by spatial light modulators (SLMs). Digital micromirror devices (DMDs) are a form of SLMs with certain advantages, such as high speed, low cost and wide availability, which present certain hurdles in their implementation, mainly the blazed grating effect caused by the jagged surface structure of the tilted mirrors. Recent works have studied this effect through modelling, simulations and experiments, and laid out possible implementations of multi-color SIM imaging based on DMDs. Here, we present an implementation of a dual-color DMD based SIM microscope using temperature-controlled wavelength matching. By carefully controlling the output wavelength of a diode laser by temperature, we can tune two laser wavelengths in such a way that no opto-mechanical realignment of the SIM setup is necessary when switching between both wavelengths. This reduces system complexity and increases imaging speed. With measurements on nano-bead reference samples, as well as the actin skeleton and membrane of fixed U2OS cells, we demonstrate the capabilities of the setup.


  • Self-contained and modular structured illumination microscope

    by Robin Van Den Eynde, Wim Vandenberg, Siewert Hugelier, Arno Bouwens, Johan Hofkens, Marcel Müller, Peter Dedecker

    We present a modular implementation of structured illumination microscopy (SIM) that is fast, largely self-contained and that can be added onto existing fluorescence microscopes. Our strategy, which we call HIT-SIM, can theoretically deliver well over 50 super-resolved images per second and is readily compatible with existing acquisition software packages. We provide a full technical package consisting of schematics, a list of components and an alignment scheme that provides detailed specifications and assembly instructions. We illustrate the performance of the instrument by imaging optically large samples containing sequence-specifically stained DNA fragments.


  • Structured illumination microscopy with noise-controlled image reconstructions

    by Carlas S. Smith, Johan A. Slotman, Lothar Schermelleh, Nadya Chakrova, Sangeetha Hari, Yoram Vos, Cornelis W. Hagen, Marcel Müller, Wiggert van Cappellen, Adriaan B. Houtsmuller, et al.

    Super-resolution structured illumination microscopy (SIM) has become a widely used method for biological imaging. Standard reconstruction algorithms, however, are prone to generate noise-specific artifacts that limit their applicability for lower signal-to-noise data. Here we present a physically realistic noise model that explains the structured noise artifact, which we then use to motivate new complementary reconstruction approaches. True-Wiener-filtered SIM optimizes contrast given the available signal-to-noise ratio, and flat-noise SIM fully overcomes the structured noise artifact while maintaining resolving power. Both methods eliminate ad hoc user-adjustable reconstruction parameters in favor of physical parameters, enhancing objectivity. The new reconstructions point to a trade-off between contrast and a natural noise appearance. This trade-off can be partly overcome by further notch filtering but at the expense of a decrease in signal-to-noise ratio. The benefits of the proposed approaches are demonstrated on focal adhesion and tubulin samples in two and three dimensions, and on nanofabricated fluorescent test patterns.