XJXiaoxing Jiang

Xiaoxing Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaoxing Jiang has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • Chun Jiang

    Department of Orthopedics, Shanghai Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China

    9 shared publications
  • Yuanwu Cao

    Department of Orthopedics, Shanghai Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China

    9 shared publications
  • Zixian Chen

    Department of Orthopedics, Zhongshan Hospital, Fudan University, Shanghai, China

    7 shared publications
  • Zixian Chen

    Department of Orthopedics, Shanghai Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China

    6 shared publications
  • Zhenzhou Feng

    Department of Orthopedics, Shanghai Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China

    5 shared publications
  • Yun Liang

    Department of Orthopaedics, Shanghai Zhongshan Hospital, Fudan University, Shanghai, People’s Republic of China

    4 shared publications

Latest Publications

  • Open Access

    The Development of Spinal Endoscopic Ultrasonic Imaging System With an Automated Tissue Recognition Algorithm

    by Chang Jiang, Yiwei Be Xiang, Zhiyang Bm Zhang, Yuanwu Cao, Nixi Bm Xu, Yinglun Mm Chen, Jiaqi Be Yao, Xiaoxing Jiang, Fang Mm Ding, Rui Zheng, et al.

    Study Design: Preclinical experimental study. Objective: To develop an intraoperative ultrasound-assisted imaging device, which could be placed at the surgical site through an endoscopic working channel and which could help surgeons recognition of different tissue types during endoscopic spinal surgery (ESS). Summary of Background Data: ESS remains a challenging task for spinal surgeons. Great proficiency and experience are needed to perform procedures such as intervertebral discectomy and neural decompression within a narrow channel. The limited surgical view poses a risk of damaging important structures, such as nerve roots. Methods: We constructed a spinal endoscopic ultrasound system, using a 4-mm custom ultrasound probe, which can be easily inserted through the ESS working channel, allowing up to 10 mm depth detection. This system was applied to ovine lumbar spine samples to obtain ultrasound images. Subsequently, we proposed a 2-stage classification algorithm, based on a pretrained DenseNet architecture for automated tissue recognition. The recognition algorithm was evaluated for accuracy and consistency. Results: The probe can be easily used in the ESS working channel and produces clear and characteristic ultrasound images. We collected 367 images for training and testing of the recognition algorithm, including images of the spinal cord, nucleus pulposus, adipose tissue, bone, annulus fibrosis, and nerve roots. The algorithm achieved over 90% accuracy in recognizing all types of tissues with a Kappa value of 0.875. The recognition times were under 0.1 s using the current configuration. Conclusion: Our system was able to be used in existing ESS working channels and identify at-risk spinal structures in vitro. The trained algorithms could identify 6 intraspinal tissue types accurately and quickly. The concept and innovative application of intraoperative ultrasound in ESS may shorten the learning curve of ESS and improve surgical efficiency and safety.

  • Open Access

    Predictive Classification System for Low Back Pain Based on Unsupervised Clustering

    by Lixia Jin, Chang Jiang, Lishu Gu, Mengying Jiang, Yuanlu Shi, Qixun Qu, Na Shen, Weibin Shi, Yuanwu Cao, Zixian Chen, et al.

    Retrospective study. Lumbar magnetic resonance imaging (MRI) findings are believed to be associated with low back pain (LBP). This study sought to develop a new predictive classification system for low back pain. Normal subjects with repeated lumbar MRI scans were retrospectively enrolled. A new classification system, based on the radiological features on MRI, was developed using an unsupervised clustering method. One hundred and fifty-nine subjects were included. Three distinguishable clusters were identified with unsupervised clustering that were significantly correlated with LBP (P = .017). The incidence of LBP was highest in cluster 3 (57.14%), nearly twice the incidence in cluster 1 (30.11%). There were obvious differences in the sagittal parameters among the 3 clusters. Cluster 3 had the smallest intervertebral height. Based on follow-up findings, 27% of subjects changed clusters. More subjects changed from cluster 1 to clusters 2 or 3 (14.5%) than changed from cluster 2 or cluster 3 to cluster 1 (5%). Participation in sport was more frequent in subjects who changed from cluster 3 to cluster 1. Using an unsupervised clustering method, we developed a new classification system comprising 3 clusters, which were significantly correlated with LBP. The prediction of LBP is independent of age and better than that based on individual sagittal parameters derived from MRI. A change in cluster during follow-up may partially predict lumbar degeneration. This study provides a new system for the prediction of LBP that should be useful for its diagnosis and treatment.


  • Open Access

    A finite element analysis on comparing the stability of different posterior fixation methods for thoracic total en bloc spondylectomy

    by Yun Liang, Yuanwu Cao, Zhiguo Gong, Chang Jiang, Lixia Jin, Zheng Li, Zixian Chen, Chun Jiang, Xiaoxing Jiang

    Objective: To compare the spinal stability with different fixation methods after thoracic TES using finite element analysis Methods: The spinal finite element model was established from a healthy volunteer, and the validity was verified. The models of T8 thoracic total en bloc spondylectomy (TES) with and without artificial vertebral body were established combination with different fixation methods: the first was long segment fixation with fixed segments T5–7, T9–11; the second was short segment fixation with fixed segments T6–7, T9–10; the third was modified short segment with a pair of vertebral body screws on T7 and T9 added on the basis of short segment fixation. The motions of each model in standing state were simulated in software. The range of motion (ROM) and internal fixation stress changes were analyzed. Results: When anterior support was effective, the three fixation methods could effectively maintain the stability of the spine. However, when anterior support failed, the ROM of the long segment fixation group and the short segment fixation group in the flexion-extension directions was significantly higher than that of when the anterior support existed, while the modified short segment fixation group had no significant changes. Meanwhile, the stress of internal fixation in the long segment fixation group and the short segment fixation group were greatly increased. However, there were no significant changes in modified short segment fixation group. Conclusion: After TES, the presence of the thoracic cage gives partial anterior stabilization. When the anterior support failed, the modified short segment fixation method can provide better stability.


  • Open Access

    Finite Element Analysis of Stability of Internal Fixation Reconstruction Methods for Lumbar Total Vertebral Resection

    by Shengcheng Wan, Zhaoyi Wu, Yuanwu Cao, Xiaoxing Jiang, Zixian Chen, Zhenzhou Feng, Chun Jiang

    Objective To compare the effect of different fixation methods on spinal stability after total en bloc spondylectomy(TES) of lumbar spine.Method The finite element models were established based on the CT scan of a healthy volunteer. After the validity of the models was confirmed, the models with different posterior fixation methods of the lumbar spine were established with and without the artificial vertebral body, respectively. The motions of flexion, extension, lateral bending and rotation under supine and standing conditions were simulated. The angular displacement of T11-L3 and stress of internal fixations were compared and analyzed.Results The finite element models of spinal reconstruction after TES were obtained. When the anterior support existed, the movement of the spine after TES was not affected by the gravity of the upper body. The movements in the opposite direction on the same plane were similar. All three methods provided enough stability to the spine. The improved short-segment fixation shared stress of the artificial vertebral body with no obvious negative effect. The long-segment fixation had stronger fixation effect with the huge loss of the range of motion of lumbar spine. When the anterior support failed, obvious rotation showed in lateral bending in all models. The short-segment fixation and the long-segment fixation failed to maintain the spinal stability with fixations breakage or functional loss. The improved short-segment fixations showed strong ability in maintaining the spinal stability. The vertebral body screws can prevent the failure of anterior fixation by sharing great stress of the whole internal fixation system. The improved short-segment had huge advantages over the others.Conclusion After TES, the improved short-segment fixation can provide more stability to the spine. The vertebral body screws can prevent the failure of the internal fixation by reducing the stress of the anterior support. This fixation method should be promoted in clinical practice while the effect requires more observation.

  • Open Access

    Cage migration after unilateral instrumented transforaminal lumbar interbody fusion and associated risk factors: a modified measurement method

    by Lixia Jin, Zixian Chen, Chun Jiang, Yuanwu Cao, Zhenzhou Feng, Xiaoxing Jiang

    Objective: In this retrospective study, a modified measurement method was used to analyze cage migration during follow-up after unilateral instrumented transforaminal lumbar interbody fusion (TLIF) and identify associated factors. Methods: We retrospectively evaluated 75 patients who had been treated with unilateral instrumented TLIF. Cage migration was quantitatively defined as anterior–posterior or lateral displacement of the cage. Results: Five patients had significant cage migration (6.7%), but none developed severe neural symptoms during follow-up or underwent reoperation. The cages tended to migrate posteriorly or toward the side of surgery. The initial cage position and patient age were strongly associated with migration. Migration was less frequent when the cages were initially placed closer to the side of surgery. Patients of advanced age were more likely to develop anterior–posterior migration than were young patients. Conclusion: Cage migration is related to the initial position of the cage. Particular attention is required when performing unilateral instrumented TLIF in patients of advanced age because they are most likely to develop cage migration. Quantification of cage migration is an effective method of exploring the associated factors.


  • MiR‐92b‐3p promotes neurite growth and functional recovery via the PTEN/AKT pathway in acute spinal cord injury

    by Zixian Chen, Zheng Li, Chang Jiang, Xiaoxing Jiang, Jian Zhang

    Emerging evidence indicates that microRNAs play an important role in neural remodeling, including neurite growth, after acute spinal cord injury (ASCI). This study aims to identify the mechanism by which miR‐92b‐3p regulates neurite growth in vivo and in vitro. Adult Sprague–Dawley rats were selected to establish the ASCI model, and the expressions of miR‐92b‐3p and phosphate and tensin homolog deleted on chromosome ten (PTEN) were quantified at different time points. The interaction between miR‐92b‐3p and PTEN was further detected in the PC12 cell line and dual‐luciferase reporter assay. Neurite growth proteins (GAP43 and NF‐200) were assessed by western blotting after miR‐92b‐3p mimics treatment. The PTEN/AKT pathway‐related proteins and their roles in miR‐92b‐3p regulation were also identified using western blotting and immunofluorescence in vitro through LY294002, an AKT inhibitor. The effect of miR‐92b‐3p was further determined in vivo according to the Basso‐Beattie‐Bresnahan (BBB) Scale and GAP43 and NF‐200 expressions. miR‐92b‐3p was downregulated after ASCI, while PTEN showed a simultaneous opposing trend. Overexpression of miR‐92b‐3p downregulated PTEN expression and promoted phosphorylation of AKT, as well as the expression of GAP43 and NF‐200 in PC12 cells. Furthermore, the dual‐luciferase reporter assay revealed that miR‐92b‐3p exerted its effect by targeting PTEN's 3ʹ‐untranslated regions and that this effect could be counteracted by AKT phosphorylation blocker LY294002 through western blotting and immunofluorescence. Moreover, miR‐92b‐3p could also improve the BBB scale as well as GAP43 and NF‐200 expression levels in vivo. Collectively, these results indicate that miR‐92b‐3p promotes neurite growth and functional recovery through the PTEN/AKT pathway in ASCI.


  • Pros and Cons: Autophagy in Acute Spinal Cord Injury

    by Zheng Li, Tianshi Chen, Yuanwu Cao, Xiaoxing Jiang, Haodong Lin, Jian Zhang, Zixian Chen


  • Open Access

    Translaminar facet joint screw insertion with a rapid prototyping guide template: a cadaver study

    by Yuanwu Cao, Wenjun Zhang, Yun Liang, Zhenzhou Feng, Chun Jiang, Zixian Chen, Xiaoxing Jiang

    It is technically demanding and requires rich experience to insert the translaminar facet screw(TFS) via the paramedian mini-incision approach. It seems that it is easy to place the TFS using computer-assisted design and rapid prototyping(RP) techniques. However, the accuracy and safety of these techniques is still unknown. The aim of this study is to assess the accuracy and safety of translaminar facet screw placement in multilevel unilateral transforaminal lumbar interbody fusion using a rapid prototyping drill guide template system. A patient-matched rapid prototyping translaminar facet screw guide was examined in fourteen cadaveric lumbar spine specimens. A three-dimensional (3D) preoperative screw trajectory was constructed using spinal computed tomography scans, from which individualized guides were developed for the placement of translaminar facet screws. Following bone tunnel establishment, the 3D positioning of the entry point and trajectory of the screws was compared to the preoperative plan as found in the Mimics software.Among 60 trajectories eligible for assessment, no cases of clinically significant laminar perforation were found. The mean deviation between the planned and the actual starting points on spinous process was 1.22 mm. The mean tail and submergence angle deviation was found to be 0.68°and 1.46°, respectively. Among all the deviations, none were found to have any statistical significance. These results indicate that translaminar facet screw placement using the guide system is both accurate and safe.


  • Pedicle Screw with Cement Augmentation in Unilateral Transforaminal Lumbar Interbody Fusion: A 2-Year Follow-Up Study

    by Yuanwu Cao, Yun Liang, Shengcheng Wan, Chun Jiang, Xiaoxing Jiang, Zixian Chen


  • Open Access

    Neuroserpin restores autophagy and promotes functional recovery after acute spinal cord injury in rats

    by Zheng Li, Fubing Liu, Liang Zhang, Yuanwu Cao, Yunchao Shao, Xiaofeng Wang, Xiaoxing Jiang, Zixian Chen

    This study is to reveal the characteristics of autophagy and the effect of neuroserpin (NSP) treatment on autophagy during the process of functional recovery following spinal cord injury (SCI). After the clip compress rat model of SCI had been made, autophagy‑associated proteins, including LC3‑II, beclin‑1 and p62, were evaluated at 2, 4, 24, 72 h, and 168 h in the experimental group, and the sham group as control. Transmission electron microscopy (TEM) was further used for autophagy detection at 4 and 72 h. All the male rats were randomly divided into three groups: Sham, vehicle and NSP group. NSP or an equal volume of saline vehicle was administered via intrathecal injection immediately after SCI. Each group was further divided into subgroups for the following experiments: i)Western blot (LC3‑II and p62); ii) Immunofluorescent double staining (LC3/MAP‑2/DAPI); iii) Nissl staining and Basso Beattie Bresnahan (BBB score) for NSP neuroprotection evaluation. Our results revealed both LC3‑II and p62 expression trended upward at 24, 72 and 168 h after SCI. The LC3‑II peaked at 72 h, while p62 peaked at 24 h. Beclin‑1 dropped significantly at 72 and 168 h. TEM results showed that autophagosomes largely accumulated at 72 h after SCI when compared with the sham group. Western blot analysis showed that LC3‑II and p62 were markedly decreased with NSP treatment at 72 h after injury compared with that of the vehicle‑group. Immunofluorescent double labeling indicated that accumulation of autophagosomes was reduced in the NSP group. Further, post‑SCI treatment with NSP improved the BBB scale and increased the number of anterior horn motor neurons. Together, this study demonstrates that autophagic flux is impaired, meanwhile NSP restores autophagic flux and promotes functional recovery after SCI in rats.