AZAbel Zhou

Abel Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abel Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Variation in digital breast tomosynthesis image quality at differing heights above the detector

    by Rob Davidson, Khaled Al Khalifah, Abel Zhou

    Introduction: The aim of this preliminary work was to determine if image quality in digital breast tomosynthesis (DBT) changes when tomosynthesis image slices were obtained at differing heights above the detector and in differing breast thicknesses. Methods: A CIRS Model 020 BR3D breast imaging phantom was used to obtain the DBT images. The images were also acquired at different tube voltages, and each exposure was determined by the automatic exposure control system. Contrast-to-noise ratio (CNR) and figure-of-merit (FOM) values were obtained and compared. Results: At a phantom thickness of 5 cm or greater, there was a significant reduction (P < 0.05) of image CNR values obtained from the images near the top of the phantom to those obtained near the bottom of the phantom. When the phantom thickness was 4 cm, there was no significant difference in CNR values between DBT images acquired at any height in the phantom. FOM values generally showed no difference when images were obtained at differing heights above the detector. Conclusion: Image quality, as measured by the CNR, was reduced when tomosynthesis slice image heights were at the top of the phantom and when the thickness of the phantom was more than 4 cm. From this preliminary work, clinicians need to be aware that DBT images obtained near the top of the breast, when breast thickness is greater than 4 cm, may have reduced image quality. Further work is needed to fully assess any DBT image quality changes when images are obtained near the top of the breast.


  • New antiscatter grid design by optimization of strip thickness and height

    by Abel Zhou, Qi Tan, Graeme L. White, Rob Davidson

    Antiscatter grids are used in biomedical X‐ray imaging to improve image quality by reducing scatter radiation reaching the image receptor. However, this comes at the cost of increasing radiation exposure. Grid performance can be improved by optimizing strip‐thickness, which reduces radiation exposure, leading to greater benefits achieved by the grid. Evidence has shown that strip height may also affect grid performance. This work investigates optimization of grid performance by varying both the strip thickness and height for a constant grid‐ratio of 15:1 (r15). A series of grid designs using lead strips and carbon‐fiber‐interspace materials for grids for high‐energy use was evaluated. The performance of these designs was determined by adopting a Monte Carlo simulation. For each grid design, the signal‐to‐noise ratio improvement factor (KSNR) was determined. A maximum value of KSNR (1.895) was found among these designs at a strip height of 6.8 mm and a thickness of 66.8 μm. The best performance of the r15‐series grids is 6% greater than that of a grid design with a grid ratio of 15:1 and a strip frequency of 44 cm−1 (found in the literature); consequently, the transmission of scatter radiation is reduced by 40%. The results show that grid designs can be optimized by both the strip height and thickness. If the optimization of the strip height and thickness cannot be done simultaneously, the recommendation is to optimize the strip height for better radiation protection without compromising the grid performance. The findings provide useful guidance for designing high‐performance antiscatter grids to reduce radiation exposure of patients.


  • The determination of the optimal strip‐thickness of anti‐scatter grids for a given grid ratio and strip height

    by Abel Zhou, Yuming Yin, Qi Tan, Graeme L. White, Rob Davidson

    In X‐ray imaging, anti‐scatter grids are used to reduce scatter radiation reaching image receptors, hence improving image quality. Optimization of grid performance is essential for improving image diagnostic quality and minimizing radiation doses to patients. This work investigated the performance of a series of grid designs modeled from the design of typically focused grid with grid ratio 8:1 (r8) and strip height 1.7 mm (h1.7) for high‐energy radiographic applications. Monte Carlo simulation was used to evaluate designs (r8h1.7) which had the strip thickness changed from 6 to 150 μm in 2 μm increments and the interspace distance fixed at 214 μm. The transmissions of radiation in grid materials were modeled by using a regression with radial‐basis‐function‐networks (RBFNS). KSNR was then determined from RBFNS models of radiation transmissions. The optimal strip‐thickness was obtained at the maximum signal‐to‐noise ratio (SNR) improvement factor (KSNR). For high‐energy applications at 100 peak‐kilo‐voltage (kVp) and 30 cm PMMA thickness, the optimal lead‐strip‐thickness was found approximately 74 μm resulting in a strip‐frequency approximately 35 per cm (N35). Using the optimal thickness for imaging condition at 100 kVp and 30 cm thickness, the KSNR would increase by approximately 5.3%. This work showed the existence of optimal strip‐thickness for a series of grids with a given grid‐ratio, strip‐height, strip‐, and interspace materials. The findings are useful and provide guidance to improve grid designs for better performance that will essentially lead to better image quality and better radiation protection for patients.


  • Using aluminum for scatter control in mammography: preliminary work using measurements of CNR and FOM

    by Khaled Al Khalifah, Rob Davidson, Abel Zhou

    Full-field digital mammography (FFDM) systems provide the current gold standard in mammographic examinations. Although FFDM provides the lowest mammographic doses, the radiation dose to the breast during mammographic examinations is still a concern. Thus, image quality optimization at the lowest dose is a major goal. In planar X-ray imaging, thin sheets of aluminum (Al) are used as filtration to reduce the number of low-energy X-ray photons reaching the patient. The goal of this work was to evaluate whether Al can be used in FFDM to remove scatter radiation from reaching the image detector, hence improving image quality. Doses were compared with the use of a grid. A Hologic Selenia mammographic unit was used to acquire images of two phantoms, namely, the ACR phantom and a Perspex phantom of 5 cm. Images were acquired using two tube voltages (kVp) and filter combinations under two exposure/dose conditions. Al sheets of various thicknesses were placed between the phantom and the image detector. Contrast-to-noise ratio (CNR) and figure of merit (FOM) values were measured and compared with images acquired using a grid. When a constant dose was delivered to the image detector, the highest CNR was achieved using a grid; however, the highest FOM values were achieved when using 0.05 mm thick Al sheets. This study successfully demonstrates that thin sheets of Al can be used in mammography examinations to reduce scattered radiation and improve image quality, as indicated by the measured CNR values. Given the limitations of this work, further kVp and target/filter combinations and various methods of image quality measurement need to be studied.


  • Validation of a Monte Carlo code system for grid evaluation with interference effect on Rayleigh scattering

    by Abel Zhou, Graeme Lindsay White, Rob Davidson

    Anti-scatter grids are commonly used in x-ray imaging systems to reduce scatter radiation reaching the image receptor. Anti-scatter grid performance and validation can be simulated through use of Monte Carlo (MC) methods. Our recently reported work has modified existing MC codes resulting in improved performance when simulating x-ray imaging. The aim of this work is to validate the transmission of x-ray photons in grids from the recently reported new MC codes against experimental results and results previously reported in other literature. The results of this work show that the scatter-to-primary ratio (SPR), the transmissions of primary ( T p ), scatter ( T s ), and total ( T t ) radiation determined using this new MC code system have strong agreement with the experimental results and the results reported in the literature. T p , T s , T t , and SPR determined in this new MC simulation code system are valid. These results also show that the interference effect on Rayleigh scattering should not be neglected in both mammographic and general grids’ evaluation. Our new MC simulation code system has been shown to be valid and can be used for analysing and evaluating the designs of grids.


  • A new solution for radiation transmission in anti-scatter grids

    by Abel Zhou, Yuming Yin, Graeme L White, Rob Davidson

    Analytic calculations of radiation transmission in focused grids or parallel grids are currently performed using the Day and Dance method. In parallel grids, this method calculates the mean transmission of radiation of grid units each of which consists of a strip and the adjacent interspace. The Day and Dance method extrapolates grid-unit-mean transmission of uniformly distributed radiation in focused grids and may underestimate the transmission of scatter radiation. This method fails to preserve detailed grid strips and interspaces information resulting from stationary grids. In this work a new method has been developed to calculate transmission of radiation. This new method and that of Day and Dance were evaluated and compared using Monte Carlo simulation. In the moving grids, the new method calculated the transmission of radiation and accounted for the effect of grid cut-off, which is approximately 4% in the transmission of primary radiation for the mammographic grid (grid ratio 5:1) or 7% for the general grid (grid ratio 15:1). In stationary grids, the new method preserves grid strips and interspace information—observed as grid lines in the x-ray image. The new method improves modelling of radiation transport in focused or parallel grids—whether moving or in stationary—over other analytical methods currently in use.