Nasir Ali
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nasir Ali has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abidullah Shah
Coordinator of Radiology Technology Muhammad Shahzeb, BS Mardan College of Medical Technology Bacha Khan Medical College Mardan Pakistan
1 shared publication Alexandre Dias Tavares Costa
Instituto Carlos Chagas (ICC), Fiocruz, Curitiba, PR, Brazil
1 shared publication- Bahrul Amin
Department of Anesthesia, College of Medical Technology, BKMC Mardan, Mardan, Pakistan
1 shared publication Graziele Lima Bello
Programa de Pos-Graduacao em Biologia Celular e Molecular Aplica a Saude (PPGBiosaude), ULBRA, Canos
1 shared publicationMarco Aurelio Krieger
Instituto de Biologia Molecular do Parana (IBMP), Curitiba, PR, Brazil
1 shared publicationMaria Lúcia Rosa Rossetti
Centro de Desenvolvimento Cientifico e Tecnologico, Secretaria Estadual de Saude, Porto Alegre, RS
1 shared publication
Latest Publications
- Open Access
- 31 January 2023
- Published by Aga Khan University Hospital in Anaesthesia, Pain & Intensive Care
- Vol. 27 (1) , 59-64
Knowledge and safety practices on occupational hazards among operating room staff in Mardan Medical Complex, Mardan, Pakistan
Background & Objectives: Healthcare workers (HCWs) are prone to occupational hazards, which may have a significant impact on their health and safety. Inadequate worker training, a lack of appropriate protection measures, and a high workload could worsen the situation, resulting in increased morbidity and mortality among exposed workers. The purpose of this study was to assess the knowledge and safety practices on occupational hazards among operating room (OR) staff of Mardan Medical Complex. Methodology: From April to September 2021, 109 OR staff participated in this cross-sectional study including the surgeons, the anesthetists, the technologists and the OR nurses. Data regarding the level of knowledge and safety practices among OR staff were recorded on a validated questionnaire. Data were analyzed on SPSS version 19 and presented in the form of tables and graphs. Chi-square test was used to find an association between categorical variables and P < 0.05 were considered statistically significant. Results: Among all participants, 95% of surgeons were aware of the work-related hazards and their types, followed by OR nurses, technologists, and the anesthetists. The majority of OR personnel with less experience were least aware of the occupational hazards. The association with the participants job experience, degree of knowledge, and the safety practices was not statistically significant (P > 0.05). Conclusion: The knowledge of the surgeons regarding occupational hazards and the safety practices was the highest, followed by the anesthetists, technicians/technologists, and the OR nurses in that order. Measures are required to promote safety practices and reinforcement of strategies aimed to minimize exposure to hazards. Routine training of staff on safety practices need to be initiated and made mandatory. Key words: Healthcare workers; Occupational Hazard; Occupational Health Risk Citation: Amin B, Ali N, Shahzeb M, Ahmad S, Shah A, Ahmad N. Knowledge and safety practices on occupational hazards among operating room staff in Mardan Medical Complex, Mardan, Pakistan. Anaesth. pain intensive care 2022;27(1):59−64. DOI: 10.35975/apic.v27i1.2119 Received: Jul 28, 2022; Reviewed: Dec 15, 2022; Accepted: Dec 18, 2022
- 31 January 2023
- Published by Aga Khan University Hospital in Anaesthesia, Pain & Intensive Care
- Vol. 27 (1) , 59-64
Open AccessKnowledge and safety practices on occupational hazards among operating room staff in Mardan Medical Complex, Mardan, Pakistan
Background & Objectives: Healthcare workers (HCWs) are prone to occupational hazards, which may have a significant impact on their health and safety. Inadequate worker training, a lack of appropriate protection measures, and a high workload could worsen the situation, resulting in increased morbidity and mortality among exposed workers. The purpose of this study was to assess the knowledge and safety practices on occupational hazards among operating room (OR) staff of Mardan Medical Complex. Methodology: From April to September 2021, 109 OR staff participated in this cross-sectional study including the surgeons, the anesthetists, the technologists and the OR nurses. Data regarding the level of knowledge and safety practices among OR staff were recorded on a validated questionnaire. Data were analyzed on SPSS version 19 and presented in the form of tables and graphs. Chi-square test was used to find an association between categorical variables and P < 0.05 were considered statistically significant. Results: Among all participants, 95% of surgeons were aware of the work-related hazards and their types, followed by OR nurses, technologists, and the anesthetists. The majority of OR personnel with less experience were least aware of the occupational hazards. The association with the participants job experience, degree of knowledge, and the safety practices was not statistically significant (P > 0.05). Conclusion: The knowledge of the surgeons regarding occupational hazards and the safety practices was the highest, followed by the anesthetists, technicians/technologists, and the OR nurses in that order. Measures are required to promote safety practices and reinforcement of strategies aimed to minimize exposure to hazards. Routine training of staff on safety practices need to be initiated and made mandatory. Key words: Healthcare workers; Occupational Hazard; Occupational Health Risk Citation: Amin B, Ali N, Shahzeb M, Ahmad S, Shah A, Ahmad N. Knowledge and safety practices on occupational hazards among operating room staff in Mardan Medical Complex, Mardan, Pakistan. Anaesth. pain intensive care 2022;27(1):59−64. DOI: 10.35975/apic.v27i1.2119 Received: Jul 28, 2022; Reviewed: Dec 15, 2022; Accepted: Dec 18, 2022
- Open Access
Demonstration of a fast and easy sample-to-answer protocol for Mycobacterium tuberculosis diagnosis in point-of-care settings
Background: Tuberculosis (TB) is currently the ninth leading cause of death worldwide and the leading cause from a single infectious agent, ranking above HIV/AIDS. Point of care diagnosis is one of the diagnostic aspects in the health care system that might have the potential to mitigate this worldwide epidemic. Although several qPCR tests are available, most cannot be taken to the field. Therefore, their use in POC settings is limited. Smooth sample preparation and streamlined DNA extraction constitute the biggest challenges for this limitation. Methods: Seventeen M. tuberculosis samples which were already previously analyzed by GeneXpert or culture technique were subjected to our in-house protocol. Of these samples, ten were positive and seven negatives when tested by GeneXpert, while seven were positive and ten negatives when analyzed by culturing. Results: Here we present a “proof of concept” protocol for sputum liquefaction and disinfection, followed by FTA card DNA extraction. The resulting DNA is rapidly amplified and Mycobacterium tuberculosis (MTB) DNA is detected with the use of a portable qPCR instrument. Our protocol is able to linearly identify down to 2 CFU/mL of MTB, showing great sensitivity on artificial samples. The protocol was challenged with patient samples, and showed excellent agreement with the gold-standard molecular protocol, allowing the detection of 9/10 positive samples (90%, or 10% of false negatives) and 7/7 of the negative (100%, no false positives). When compared to culture, 7/7 culture-positive samples were also found positive (100%, no false negatives), while 2/10 culture-negative were found positive by the present method (20% of false positives). Conclusion: The proposed sample preparation protocol provides a rapid and easy procedure with a small number of reagents and steps, as well as minimal use of equipments, resulting in an easy-to-use tool for M. tuberculosis diagnosis in POC settings.
Open AccessDemonstration of a fast and easy sample-to-answer protocol for Mycobacterium tuberculosis diagnosis in point-of-care settings
Background: Tuberculosis (TB) is currently the ninth leading cause of death worldwide and the leading cause from a single infectious agent, ranking above HIV/AIDS. Point of care diagnosis is one of the diagnostic aspects in the health care system that might have the potential to mitigate this worldwide epidemic. Although several qPCR tests are available, most cannot be taken to the field. Therefore, their use in POC settings is limited. Smooth sample preparation and streamlined DNA extraction constitute the biggest challenges for this limitation. Methods: Seventeen M. tuberculosis samples which were already previously analyzed by GeneXpert or culture technique were subjected to our in-house protocol. Of these samples, ten were positive and seven negatives when tested by GeneXpert, while seven were positive and ten negatives when analyzed by culturing. Results: Here we present a “proof of concept” protocol for sputum liquefaction and disinfection, followed by FTA card DNA extraction. The resulting DNA is rapidly amplified and Mycobacterium tuberculosis (MTB) DNA is detected with the use of a portable qPCR instrument. Our protocol is able to linearly identify down to 2 CFU/mL of MTB, showing great sensitivity on artificial samples. The protocol was challenged with patient samples, and showed excellent agreement with the gold-standard molecular protocol, allowing the detection of 9/10 positive samples (90%, or 10% of false negatives) and 7/7 of the negative (100%, no false positives). When compared to culture, 7/7 culture-positive samples were also found positive (100%, no false negatives), while 2/10 culture-negative were found positive by the present method (20% of false positives). Conclusion: The proposed sample preparation protocol provides a rapid and easy procedure with a small number of reagents and steps, as well as minimal use of equipments, resulting in an easy-to-use tool for M. tuberculosis diagnosis in POC settings.