Tomohiro Namimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tomohiro Namimoto has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Yasuyuki Yamashita
Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuoku, Kumamoto, 860-8556, Japan
9 shared publications- Daisuke Utsunomiya
Department of Diagnostic Radiology, Yokohama City University Graduate School of Medicine, Yokohama 236-0004, Japan
6 shared publications Takeshi Nakaura
Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuoku, Kumamoto, 860-8556, Japan
6 shared publications- Takeshi Nakaura
Department of Central Radiology, Kumamoto University Hospital, 1-1-1 Honjo, Kumamoto 860-8556, Japan
5 shared publications Kosuke Morita
Department of Diagnostic Radiology, Graduate School of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuoku, Kumamoto 860-8556, Japan
4 shared publications- Masafumi Kidoh
Kumamoto University
4 shared publications
Latest Publications
- 1 November 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 108, 147-154
Machine learning based on multi-parametric magnetic resonance imaging to differentiate glioblastoma multiforme from primary cerebral nervous system lymphoma
- 1 November 2018
- Published by Elsevier in European Journal of Radiology
- Vol. 108, 147-154
Machine learning based on multi-parametric magnetic resonance imaging to differentiate glioblastoma multiforme from primary cerebral nervous system lymphoma
- 1 November 2018
- Published by Elsevier in Clinical Imaging
- Vol. 52, 11-15
Reducing artifacts of gadoxetate disodium-enhanced MRI with oxygen inhalation in patients with prior episode of arterial phase motion: intra-individual comparison
- 1 November 2018
- Published by Elsevier in Clinical Imaging
- Vol. 52, 11-15
Reducing artifacts of gadoxetate disodium-enhanced MRI with oxygen inhalation in patients with prior episode of arterial phase motion: intra-individual comparison
- 6 November 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1081) , 20170285
Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners
Objective: Different CT scanners have different X-ray spectra and photon energies indicating that contrast enhancement vary among scanners. However, this issue has not been fully validated; therefore, we performed phantom and clinical studies to assess this difference. Methods: Two scanners were used: scanner-A and scanner-B. In the phantom study, we compared the contrast enhancement between the scanners at tube voltage peaks of 80, 100 and 120 kVp. Then, we calculated the effective energies of the two CT scanners. In the clinical study, 40 patients underwent abdominal scanning with scanner-A and another 40 patients with scanner-B, with each group using the same scanning protocol. The contrast enhancement of abdominal organs was assessed quantitatively (based on the absolute difference between the attenuation of unenhanced scans and contrast-enhanced scans) and qualitatively. A two-tailed independent Student's t-test and or the Mann–Whitney U test were used to compare the discrepancies. Results: In the phantom study, contrast enhancement for scanner-B was 36.9, 32.6 and 30.8% higher than that for scanner-A at 80, 100 and 120 kVp, respectively. The effective energies were higher for scanner-A than for scanner-B. In the quantitative analysis for the clinical study, scanner-B yielded significantly better contrast enhancement of the hepatic parenchyma, pancreas, kidney, portal vein and inferior vena cava compared with that of scanner-A. The mean visual scores for contrast enhancement were also significantly higher on images obtained by scanner-B than those by scanner-A. Conclusion: There were significant differences in contrast enhancement of the abdominal organs between the compared CT scanners from two different vendors even at the same scanning and contrast parameters. Advances in knowledge: Awareness of the impact of different X-ray energies on the resultant attenuation of contrast material is important when interpreting clinical CT images.
- 6 November 2017
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1081) , 20170285
Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners
Objective: Different CT scanners have different X-ray spectra and photon energies indicating that contrast enhancement vary among scanners. However, this issue has not been fully validated; therefore, we performed phantom and clinical studies to assess this difference. Methods: Two scanners were used: scanner-A and scanner-B. In the phantom study, we compared the contrast enhancement between the scanners at tube voltage peaks of 80, 100 and 120 kVp. Then, we calculated the effective energies of the two CT scanners. In the clinical study, 40 patients underwent abdominal scanning with scanner-A and another 40 patients with scanner-B, with each group using the same scanning protocol. The contrast enhancement of abdominal organs was assessed quantitatively (based on the absolute difference between the attenuation of unenhanced scans and contrast-enhanced scans) and qualitatively. A two-tailed independent Student's t-test and or the Mann–Whitney U test were used to compare the discrepancies. Results: In the phantom study, contrast enhancement for scanner-B was 36.9, 32.6 and 30.8% higher than that for scanner-A at 80, 100 and 120 kVp, respectively. The effective energies were higher for scanner-A than for scanner-B. In the quantitative analysis for the clinical study, scanner-B yielded significantly better contrast enhancement of the hepatic parenchyma, pancreas, kidney, portal vein and inferior vena cava compared with that of scanner-A. The mean visual scores for contrast enhancement were also significantly higher on images obtained by scanner-B than those by scanner-A. Conclusion: There were significant differences in contrast enhancement of the abdominal organs between the compared CT scanners from two different vendors even at the same scanning and contrast parameters. Advances in knowledge: Awareness of the impact of different X-ray energies on the resultant attenuation of contrast material is important when interpreting clinical CT images.
- 1 November 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 96, 85-90
Comparison between multi-shot gradient echo EPI and balanced SSFP in unenhanced 3T MRA of thoracic aorta in healthy volunteers
- 1 November 2017
- Published by Elsevier in European Journal of Radiology
- Vol. 96, 85-90
Comparison between multi-shot gradient echo EPI and balanced SSFP in unenhanced 3T MRA of thoracic aorta in healthy volunteers
- 1 September 2017
- Published by Elsevier in Clinical Imaging
- Vol. 45, 111-117
Hepatic fat quantification using automated six-point Dixon: Comparison with conventional chemical shift based sequences and computed tomography
- 1 September 2017
- Published by Elsevier in Clinical Imaging
- Vol. 45, 111-117
Hepatic fat quantification using automated six-point Dixon: Comparison with conventional chemical shift based sequences and computed tomography
- Open Access
- 9 August 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1311
Efficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase hepatic MRI
- 9 August 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1311
Open AccessEfficacy of the projection onto convex sets (POCS) algorithm at Gd-EOB-DTPA-enhanced hepatobiliary-phase hepatic MRI
- Open Access
- 24 April 2015
- Published by Springer Nature in Surgical Case Reports
- Vol. 1 (1) , 1-6
Hepatic angiomyolipoma with special attention to radiologic imaging
Background: Angiomyolipoma is a unique mesenchymal neoplasm composed of blood vessels as well as smooth muscle and adipose cells. The liver is a less common site of origin, and hepatic angiomyolipoma is often an incidental finding on diagnostic imaging or is identified on evaluation of nonspecific symptoms. Case presentation: We experienced four patients who were diagnosed histologically with hepatic angiomyolipoma. The preoperative diagnoses were angiomyolipoma in two patients, hepatocellular carcinoma in one, and cavernous hemangioma in one. Three patients were treated with hepatectomy (one laparoscopic and two open approaches), and the diagnosis was completed by histological investigation of the resected specimen. The remaining one was diagnosed from tumor needle biopsy. Diffusion-weighted magnetic resonance imaging (MRI) with respiratory triggering using b values of 0 and 800 s/mm2 was employed. An apparent diffusion coefficient map was generated from b values of 0 and 800 s/mm2 for calculation of the apparent diffusion coefficient. The apparent diffusion coefficient values were calculated as 3.66, 1.21, 1.80, and 0.91 in patients 1 to 4, respectively. In MRI imaging, fat component was clearly demonstrated with chemical shift imaging in three patients. Early venous return was detected in three patients with computed tomography angiography. Conclusion: Fat component and early venous return are important for a correct diagnosis of hepatic angiomyolipoma. Unfortunately, apparent diffusion coefficient values in hepatic angiomyolipoma were overlapping with those in other benign and malignant tumors.
- 24 April 2015
- Published by Springer Nature in Surgical Case Reports
- Vol. 1 (1) , 1-6
Open AccessHepatic angiomyolipoma with special attention to radiologic imaging
Background: Angiomyolipoma is a unique mesenchymal neoplasm composed of blood vessels as well as smooth muscle and adipose cells. The liver is a less common site of origin, and hepatic angiomyolipoma is often an incidental finding on diagnostic imaging or is identified on evaluation of nonspecific symptoms. Case presentation: We experienced four patients who were diagnosed histologically with hepatic angiomyolipoma. The preoperative diagnoses were angiomyolipoma in two patients, hepatocellular carcinoma in one, and cavernous hemangioma in one. Three patients were treated with hepatectomy (one laparoscopic and two open approaches), and the diagnosis was completed by histological investigation of the resected specimen. The remaining one was diagnosed from tumor needle biopsy. Diffusion-weighted magnetic resonance imaging (MRI) with respiratory triggering using b values of 0 and 800 s/mm2 was employed. An apparent diffusion coefficient map was generated from b values of 0 and 800 s/mm2 for calculation of the apparent diffusion coefficient. The apparent diffusion coefficient values were calculated as 3.66, 1.21, 1.80, and 0.91 in patients 1 to 4, respectively. In MRI imaging, fat component was clearly demonstrated with chemical shift imaging in three patients. Early venous return was detected in three patients with computed tomography angiography. Conclusion: Fat component and early venous return are important for a correct diagnosis of hepatic angiomyolipoma. Unfortunately, apparent diffusion coefficient values in hepatic angiomyolipoma were overlapping with those in other benign and malignant tumors.
- 27 February 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (7) , 1911-1918
Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography
To evaluate the quality of magnetic resonance cholangiopancreatography (MRCP) images obtained with a three-dimensional navigator-gated (NG) technique and compare findings with conventional respiratory-triggered (RT) images in pre-laparoscopic cholecystectomy patients. Turbo-spin-echo (TSE) RT-MRCP (average 242 s) and balanced turbo-field-echo (bTFE) NG-MRCP (average 263 s) were acquired at 1.5-T MRI for 49 pre-laparoscopic cholecystectomy patients. Two radiologists independently assessed image quality, visibility of anatomical structures, common bile duct (CBD) stones, and signal-to-noise ratios (SNRs). Interobserver agreement was also evaluated. The anatomical details of the cystic duct were clearly demonstrated in 33 (67.3 %, reader A) and 35 (71.4 %, reader B) patients on RT-MRCP, and in 45 (91.8 %) and 44 (89.7 %) patients on NG-MRCP. On NG-MRCP, visualisation of the cystic duct (3.22/3.12), its origin (3.57/3.55), and the gallbladder(3.61/3.59) was statistically better than on RT-MRCP (2.90/2.78, 3.29/3.12, 2.98/2.88, respectively). The overall image quality was statistically better on NG-MRCP than RT-MRCP. Each technique identified the presence of CBD stones in all affected patients. The SNR was significantly higher on NG-MRCP (CHD 22.40, gallbladder 17.13) than RT-MRCP (CHD 17.05, gallbladder 9.30). Interobserver agreement was fair to perfect. Navigator-gated MRCP is more useful than respiratory-triggered MRCP for evaluating the gallbladder and cystic duct in patients scheduled for laparoscopic cholecystectomy. • Magnetic resonance cholangiopancreatography (MRCP) provides important cystic duct information before laparoscopic cholecystectomy. • Navigator-gated (NG) MRCP images were better than conventional respiratory-triggered (RT) MRCP. • The signal-to-noise ratio was significantly higher for NG-MRCP than for conventional RT-MRCP. • Balanced turbo-field-echo NG-MRCP is useful for evaluating the gallbladder and cystic duct.
- 27 February 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (7) , 1911-1918
Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography
To evaluate the quality of magnetic resonance cholangiopancreatography (MRCP) images obtained with a three-dimensional navigator-gated (NG) technique and compare findings with conventional respiratory-triggered (RT) images in pre-laparoscopic cholecystectomy patients. Turbo-spin-echo (TSE) RT-MRCP (average 242 s) and balanced turbo-field-echo (bTFE) NG-MRCP (average 263 s) were acquired at 1.5-T MRI for 49 pre-laparoscopic cholecystectomy patients. Two radiologists independently assessed image quality, visibility of anatomical structures, common bile duct (CBD) stones, and signal-to-noise ratios (SNRs). Interobserver agreement was also evaluated. The anatomical details of the cystic duct were clearly demonstrated in 33 (67.3 %, reader A) and 35 (71.4 %, reader B) patients on RT-MRCP, and in 45 (91.8 %) and 44 (89.7 %) patients on NG-MRCP. On NG-MRCP, visualisation of the cystic duct (3.22/3.12), its origin (3.57/3.55), and the gallbladder(3.61/3.59) was statistically better than on RT-MRCP (2.90/2.78, 3.29/3.12, 2.98/2.88, respectively). The overall image quality was statistically better on NG-MRCP than RT-MRCP. Each technique identified the presence of CBD stones in all affected patients. The SNR was significantly higher on NG-MRCP (CHD 22.40, gallbladder 17.13) than RT-MRCP (CHD 17.05, gallbladder 9.30). Interobserver agreement was fair to perfect. Navigator-gated MRCP is more useful than respiratory-triggered MRCP for evaluating the gallbladder and cystic duct in patients scheduled for laparoscopic cholecystectomy. • Magnetic resonance cholangiopancreatography (MRCP) provides important cystic duct information before laparoscopic cholecystectomy. • Navigator-gated (NG) MRCP images were better than conventional respiratory-triggered (RT) MRCP. • The signal-to-noise ratio was significantly higher for NG-MRCP than for conventional RT-MRCP. • Balanced turbo-field-echo NG-MRCP is useful for evaluating the gallbladder and cystic duct.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (5) , 790-796
Dynamic Computed Tomography of Locally Advanced Pancreatic Cancer
The objective of this study was to evaluate the effect of a low-tube-voltage technique and hybrid iterative reconstruction (HIR) on image quality at dynamic computed tomography (CT) of the pancreas. The study included 18 consecutive patients (10 women, 8 men; mean age, 68.5 ± 9.5 years) with locally advanced pancreatic cancer who received chemotherapy and had stable disease during the 100- and 120-kV CT studies. The 120-kV images were reconstructed using filtered back projection, and the 100-kV images were postprocessed using filtered back projection and HIR. Scans obtained during 3 pancreatic phases were subjected to quantitative and qualitative analysis. The mean effective dose was significantly lower under the 100- than the 120-kV protocols (29.2 ± 3.6 vs 52.1 ± 5.1 mSv; P < 0.01). The mean contrast-to-noise ratio of the pancreatic cancer and the visual scores were significantly higher under 100 kV with HIR than those under the other 2 protocols (P < 0.01). Use of low tube voltage and HIR can provide significantly improved image quality at pancreatic dynamic CT.
- 1 January 2013
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 37 (5) , 790-796
Dynamic Computed Tomography of Locally Advanced Pancreatic Cancer
The objective of this study was to evaluate the effect of a low-tube-voltage technique and hybrid iterative reconstruction (HIR) on image quality at dynamic computed tomography (CT) of the pancreas. The study included 18 consecutive patients (10 women, 8 men; mean age, 68.5 ± 9.5 years) with locally advanced pancreatic cancer who received chemotherapy and had stable disease during the 100- and 120-kV CT studies. The 120-kV images were reconstructed using filtered back projection, and the 100-kV images were postprocessed using filtered back projection and HIR. Scans obtained during 3 pancreatic phases were subjected to quantitative and qualitative analysis. The mean effective dose was significantly lower under the 100- than the 120-kV protocols (29.2 ± 3.6 vs 52.1 ± 5.1 mSv; P < 0.01). The mean contrast-to-noise ratio of the pancreatic cancer and the visual scores were significantly higher under 100 kV with HIR than those under the other 2 protocols (P < 0.01). Use of low tube voltage and HIR can provide significantly improved image quality at pancreatic dynamic CT.