Danny Omar Mendoza Marin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Danny Omar Mendoza Marin has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Ana Carolina Pero
Universidade Estadual Paulista, Brasil
13 shared publications - Andressa Rosa Perin Leite
Doctoral student, Department of Dental Materials and Prosthodontics, Araraquara Dental School, Sao Paulo State University (UNESP), Araraquara, Sao Paulo, Brazil
8 shared publications - André Gustavo Paleari
Department of Dental Materials and Prosthodontics, Araraquara Dental School, UNESP, Univ Estadual Paulista, Araraquara, São Paulo, Brazil
7 shared publications Marco Antonio Compagnoni
Professor, Department of Dental Materials and Prosthodontics, Araraquara Dental School, São Paulo State University (UNESP), Araraquara, Brazil
7 shared publications- Marco Antonio Compagnoni
São Paulo State University, Brazil
6 shared publications Gabriela Giro
UNESP - Univ Estadual Paulista, Araraquara Dental School, Department of Dental Materials and Prosthodontics, Araraquara, São Paulo, Brazil
5 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Biomaterials
- Vol. 2024 (1) , 2167066
Synthesis of Calcium Phosphate by Microwave Hydrothermal Method
Bone loss in the alveolar ridge is a factor widely studied by dentists in implant surgeries, as it poses a major challenge for aesthetic and functional recovery in patients with large maxillary bone defects. Synthetic biomaterials function as grafts designed to replace and remodel bone tissue. Calcium phosphate is a biomaterial that has good properties such as biocompatibility and bioactivity, making it a reference in bone replacement treatments. A synthetic biomaterial such as calcium phosphate can be obtained by various synthesis techniques. The microwave hydrothermal method (HTMO) is a pathway that allows changes in synthesis parameters and significantly increases the transmission efficiency of materials such as synthetic calcium phosphate derivatives. The study proposes obtaining a biomaterial for bone grafting based on calcium phosphate by the microwave HTMO and evaluating its microstructural and physicochemical characteristics. The parameters tested in this process were temperature and reaction time. The calcium phosphate particulates were obtained by the microwave HTMO at temperatures of 110°C and 130°C for 60 min and calcined at 300°C, 500°C, and 700°C. Microstructural and physicochemical characterization analyses were carried out using scanning electron microscopy, Fourier transform infrared, and X‐ray diffraction. The results obtained showed the presence of more than one calcium phosphate biological interest phase, as hydroxyapatite (HA), tricalcium phosphate (β‐TCP), and octacalcium phosphate (OCP), highlighting with increasing calcination temperature, the β‐TCP phase becomes evident. The proposed synthesis method was efficient in obtaining a biomaterial with suitable physical and chemical characteristics, with an association of crystalline phases of biological interest related to the increase in synthesis temperature and calcination temperature.
- 1 January 2024
- Published by Wiley in International Journal of Biomaterials
- Vol. 2024 (1) , 2167066
Open AccessSynthesis of Calcium Phosphate by Microwave Hydrothermal Method
Bone loss in the alveolar ridge is a factor widely studied by dentists in implant surgeries, as it poses a major challenge for aesthetic and functional recovery in patients with large maxillary bone defects. Synthetic biomaterials function as grafts designed to replace and remodel bone tissue. Calcium phosphate is a biomaterial that has good properties such as biocompatibility and bioactivity, making it a reference in bone replacement treatments. A synthetic biomaterial such as calcium phosphate can be obtained by various synthesis techniques. The microwave hydrothermal method (HTMO) is a pathway that allows changes in synthesis parameters and significantly increases the transmission efficiency of materials such as synthetic calcium phosphate derivatives. The study proposes obtaining a biomaterial for bone grafting based on calcium phosphate by the microwave HTMO and evaluating its microstructural and physicochemical characteristics. The parameters tested in this process were temperature and reaction time. The calcium phosphate particulates were obtained by the microwave HTMO at temperatures of 110°C and 130°C for 60 min and calcined at 300°C, 500°C, and 700°C. Microstructural and physicochemical characterization analyses were carried out using scanning electron microscopy, Fourier transform infrared, and X‐ray diffraction. The results obtained showed the presence of more than one calcium phosphate biological interest phase, as hydroxyapatite (HA), tricalcium phosphate (β‐TCP), and octacalcium phosphate (OCP), highlighting with increasing calcination temperature, the β‐TCP phase becomes evident. The proposed synthesis method was efficient in obtaining a biomaterial with suitable physical and chemical characteristics, with an association of crystalline phases of biological interest related to the increase in synthesis temperature and calcination temperature.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , 669-689
Failures in Single Extra-Short Implants (≤ 6 mm): A Systematic Review and Meta-analysis
Maur?cio Malheiros Badar?, DDS, PhD/Danny Omar Mendoza Marin, DDS, PhD/Patr?cia Pauletto, DDS, MSc/Thais Marques Simek Vega Gon?alves, DDS, PhD/Andr? Lu?s Porporatti, DDS, PhD/Graziela De Luca Canto, DDS, PhD: Purpose: The aim of this systematic review with meta-analysis was to compare the survival rate of single crowns supported by extra-short implants (≤ 6 mm) to those supported by conventional implants, with or without previous maxillary sinus augmentation. The proportion of failures was described according to the type of complication and follow-up periods. Materials and Methods: Randomized and prospective clinical trials were selected from six databases and gray literature. The risk of bias was evaluated by Joanna Briggs Institute Critical Appraisal Checklist, and the certainty of the evidence was analyzed with Grading of Recommendations Assessment, Development, and Evaluation. Meta-analyses were processed with RevMan and MedCalc Statistical Software. Results: Single crowns supported by extra-short implants had a similar risk of failure to those supported by conventional implants, regardless of previous maxillary sinus augmentation (P > .05). Overall failure proportion of extra-short implants was 5.19%, but it varied according to follow-up (1.18% before loading, 1.56% at 12 months, 1.20% at 24 months, 2.10% at 48 months). Biologic failure complications were 37.90% for bleeding on probing, 22.45% for peri-implantitis, and 11.29% for infection. Prosthodontics failure complications were 14.88% for abutment failures and 14.73% for prosthetic screw loosening. Considering the risk of bias, most studies were classified at moderate risk. Conclusion: The risk of failure of single crowns supported by extra-short implants is similar to those supported by conventional implants, regardless of previous maxillary sinus augmentation or follow-up period. The most frequent biologic and prosthetic complications were bleeding on probing and abutment failures, respectively.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Oral and Maxillofacial Implants
- Vol. 36 (4) , 669-689
Failures in Single Extra-Short Implants (≤ 6 mm): A Systematic Review and Meta-analysis
Maur?cio Malheiros Badar?, DDS, PhD/Danny Omar Mendoza Marin, DDS, PhD/Patr?cia Pauletto, DDS, MSc/Thais Marques Simek Vega Gon?alves, DDS, PhD/Andr? Lu?s Porporatti, DDS, PhD/Graziela De Luca Canto, DDS, PhD: Purpose: The aim of this systematic review with meta-analysis was to compare the survival rate of single crowns supported by extra-short implants (≤ 6 mm) to those supported by conventional implants, with or without previous maxillary sinus augmentation. The proportion of failures was described according to the type of complication and follow-up periods. Materials and Methods: Randomized and prospective clinical trials were selected from six databases and gray literature. The risk of bias was evaluated by Joanna Briggs Institute Critical Appraisal Checklist, and the certainty of the evidence was analyzed with Grading of Recommendations Assessment, Development, and Evaluation. Meta-analyses were processed with RevMan and MedCalc Statistical Software. Results: Single crowns supported by extra-short implants had a similar risk of failure to those supported by conventional implants, regardless of previous maxillary sinus augmentation (P > .05). Overall failure proportion of extra-short implants was 5.19%, but it varied according to follow-up (1.18% before loading, 1.56% at 12 months, 1.20% at 24 months, 2.10% at 48 months). Biologic failure complications were 37.90% for bleeding on probing, 22.45% for peri-implantitis, and 11.29% for infection. Prosthodontics failure complications were 14.88% for abutment failures and 14.73% for prosthetic screw loosening. Considering the risk of bias, most studies were classified at moderate risk. Conclusion: The risk of failure of single crowns supported by extra-short implants is similar to those supported by conventional implants, regardless of previous maxillary sinus augmentation or follow-up period. The most frequent biologic and prosthetic complications were bleeding on probing and abutment failures, respectively.
- Open Access
- 11 June 2018
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 47 (3) , 143-148
Effect of educational and self-care therapies on masticatory performance of women with painful temporomandibular disorder
Introduction Temporomandibular disorders (TMD) can compromise masticatory performance due to the presence of pain, muscular dysfunction and limitation of mandibular movements. Substantial improvements in TMD pain can be achieved through therapeutic approaches including education and self-care. Objective The aim of the present study was to investigate the impact of these treatment modalities in the masticatory performance of women with painful TMD. Material and method Fifty-two women were randomly divided into three groups: Control Group (CG); Education Group (received education about TMD) (EG); Self-Care and Education Group (received education about TMD and instructions self-care therapies) (SEG). The education instructions about TMD and self-care therapies were transmitted through a video and printed illustrative material. The masticatory performance was evaluated through the sieves method with natural tested foods in the evaluation periods: baseline evaluation, 30 days after and 60 days of follow-up. Data were analyzed and used with a one-way ANOVA parametric test for mean comparison of CG, EG and SEG groups (α = 0.05). Result The masticatory performance of the participants was similar, irrespective of the proposed treatments, at baseline (p=.604), 30 days (p=.450) and 60 days (p=.669). Conclusions The results indicated that treatment with educational and self-care therapies over a period of 60 days had no impact on the masticatory performance of women with painful TMD.
- 11 June 2018
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 47 (3) , 143-148
Open AccessEffect of educational and self-care therapies on masticatory performance of women with painful temporomandibular disorder
Introduction Temporomandibular disorders (TMD) can compromise masticatory performance due to the presence of pain, muscular dysfunction and limitation of mandibular movements. Substantial improvements in TMD pain can be achieved through therapeutic approaches including education and self-care. Objective The aim of the present study was to investigate the impact of these treatment modalities in the masticatory performance of women with painful TMD. Material and method Fifty-two women were randomly divided into three groups: Control Group (CG); Education Group (received education about TMD) (EG); Self-Care and Education Group (received education about TMD and instructions self-care therapies) (SEG). The education instructions about TMD and self-care therapies were transmitted through a video and printed illustrative material. The masticatory performance was evaluated through the sieves method with natural tested foods in the evaluation periods: baseline evaluation, 30 days after and 60 days of follow-up. Data were analyzed and used with a one-way ANOVA parametric test for mean comparison of CG, EG and SEG groups (α = 0.05). Result The masticatory performance of the participants was similar, irrespective of the proposed treatments, at baseline (p=.604), 30 days (p=.450) and 60 days (p=.669). Conclusions The results indicated that treatment with educational and self-care therapies over a period of 60 days had no impact on the masticatory performance of women with painful TMD.
- 1 March 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 119 (3) , 404-408
Proinflammatory cytokine production from NOK-SI keratinocytes after exposure to denture adhesives
- 1 March 2018
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 119 (3) , 404-408
Proinflammatory cytokine production from NOK-SI keratinocytes after exposure to denture adhesives
- 1 August 2017
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 43 (4) , 297-301
Custom Cast Ball Attachments Used on Outdated Implants to Restore a Maxillary Implant-Supported Overdenture
The lack of compatible prosthetic components can be a complication during oral rehabilitation using outdated implants. The aim of the present clinical report was to describe an alternative technique for the fabrication of a maxillary implant-supported overdenture in a patient with 20-year-old dental implants using castable spherical patterns and ball attachments. The patient had been wearing a relined bar/clip overdenture in the mandible on 4 external-hexagon dental implants and a relined complete denture in the maxilla on 4 internal-hexagon implants due to abutment screw fracture inside of the implants, losing the attachment system. The remaining maxillary dental implants did not possess attachments compatible with current systems due to configuration changes by the manufacturer in the dental implant's platform and the components over time. Therefore, castable spherical patterns and cast ball attachments were used to fabricate a maxillary implant-supported overdenture. The mandible rehabilitation was performed using 4 osseointegrated dental implants with a fixed implant-supported prosthesis. The use of cast ball attachments on the maxillary dental implants avoided invasive procedures on the remaining implants. Considering the lack of available compatible prosthetic components for the osseointegrated implants, this technique was considered a viable and satisfactory treatment option.
- 1 August 2017
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 43 (4) , 297-301
Custom Cast Ball Attachments Used on Outdated Implants to Restore a Maxillary Implant-Supported Overdenture
The lack of compatible prosthetic components can be a complication during oral rehabilitation using outdated implants. The aim of the present clinical report was to describe an alternative technique for the fabrication of a maxillary implant-supported overdenture in a patient with 20-year-old dental implants using castable spherical patterns and ball attachments. The patient had been wearing a relined bar/clip overdenture in the mandible on 4 external-hexagon dental implants and a relined complete denture in the maxilla on 4 internal-hexagon implants due to abutment screw fracture inside of the implants, losing the attachment system. The remaining maxillary dental implants did not possess attachments compatible with current systems due to configuration changes by the manufacturer in the dental implant's platform and the components over time. Therefore, castable spherical patterns and cast ball attachments were used to fabricate a maxillary implant-supported overdenture. The mandible rehabilitation was performed using 4 osseointegrated dental implants with a fixed implant-supported prosthesis. The use of cast ball attachments on the maxillary dental implants avoided invasive procedures on the remaining implants. Considering the lack of available compatible prosthetic components for the osseointegrated implants, this technique was considered a viable and satisfactory treatment option.
- Open Access
- 1 January 2017
- Published by Wiley in Case Reports in Dentistry
- Vol. 2017 (1) , 5796768
Free Gingival Graft to Increase Keratinized Mucosa after Placing of Mandibular Fixed Implant‐Supported Prosthesis
Insufficiently keratinized tissue can be increased surgically by free gingival grafting. The presence or reconstruction of keratinized mucosa around the implant can facilitate restorative procedure and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. The aim of this clinical case report is to describe an oral rehabilitation procedure of an edentulous patient with absence of keratinized mucosa in the interforaminal area, using a free gingival graft associated with a mandibular fixed implant‐supported prosthesis. The treatment included the manufacturing of a maxillary complete denture and a mandibular fixed implant‐supported prosthesis followed by a free gingival graft to increase the width of the mandibular keratinized mucosa. Free gingival graft was obtained from the palate and grafted on the buccal side of interforaminal area. The follow‐up of 02 and 12 months after mucogingival surgery showed that the free gingival graft promoted peri‐implant health, hygiene, and patient comfort. Clinical Significance . The free gingival graft is an effective treatment in increasing the width of mandibular keratinized mucosa on the buccal side of the interforaminal area and provided an improvement in maintaining the health of peri‐implant tissues which allows for better oral hygiene.
- 1 January 2017
- Published by Wiley in Case Reports in Dentistry
- Vol. 2017 (1) , 5796768
Open AccessFree Gingival Graft to Increase Keratinized Mucosa after Placing of Mandibular Fixed Implant‐Supported Prosthesis
Insufficiently keratinized tissue can be increased surgically by free gingival grafting. The presence or reconstruction of keratinized mucosa around the implant can facilitate restorative procedure and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. The aim of this clinical case report is to describe an oral rehabilitation procedure of an edentulous patient with absence of keratinized mucosa in the interforaminal area, using a free gingival graft associated with a mandibular fixed implant‐supported prosthesis. The treatment included the manufacturing of a maxillary complete denture and a mandibular fixed implant‐supported prosthesis followed by a free gingival graft to increase the width of the mandibular keratinized mucosa. Free gingival graft was obtained from the palate and grafted on the buccal side of interforaminal area. The follow‐up of 02 and 12 months after mucogingival surgery showed that the free gingival graft promoted peri‐implant health, hygiene, and patient comfort. Clinical Significance . The free gingival graft is an effective treatment in increasing the width of mandibular keratinized mucosa on the buccal side of the interforaminal area and provided an improvement in maintaining the health of peri‐implant tissues which allows for better oral hygiene.
- Open Access
- 1 September 2016
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 5 (03) , 122-126
Physical properties of acrylic resin teeth submitted to toothbrushing and immersion in beverages
Background: Brushing and consumption of dye beverages may alter the physical properties of artificial teeth. Objective: The objective of this study was to evaluate the effect of toothbrushing and immersion in beverages in roughness and color of two types of artificial teeth: Biotone (B) and Biotone interpenetrating polymer network (IPN). Materials and Methods: For each tooth, seven groups were formed (n = 10): Toothbrushing (T), toothbrushing + water (TW), toothbrushing + coke (TCk), toothbrushing + coffee (TCf), immersion in water (W), coke (Ck), coffee (Cf). Roughness and color stability evaluations were performed before treatment and after treatment. According to the group, 11,000 brushing cycles were performed and specimens were immersed in beverages for 12 days, both simulating a period of 1 year. Color variations were captured by a spectrophotometer and roughness was analyzed by a profilometer. Color data were analyzed using analysis of variance (ANOVA) and Least significant difference test whereas roughness data were analyzed using ANOVA and Bonferroni test, both with α =0.05. Results: For Biotone, clinical significant color changes according to National Bureau of Standards (NBS) units were observed for the Groups T, TW, W, and Ck, and the results of ΔE were statistically similar among them (P > 0.05). For Biotone IPN, clinical significant color changes were found for TCf (4.86 NBS units) and Cf (4.82), and the results of ΔE were also similar among them. Surface roughness Ra (μm), regardless of the teeth, was reduced for the groups submitted to toothbrushing whereas no significant differences were found among the Groups W, Ck, and Cf. Conclusions: Toothbrushing had no influence on the color stability but significantly reduced the roughness, irrespective of the type of tooth.
- 1 September 2016
- Published by Georg Thieme Verlag KG in European Journal of General Dentistry
- Vol. 5 (03) , 122-126
Open AccessPhysical properties of acrylic resin teeth submitted to toothbrushing and immersion in beverages
Background: Brushing and consumption of dye beverages may alter the physical properties of artificial teeth. Objective: The objective of this study was to evaluate the effect of toothbrushing and immersion in beverages in roughness and color of two types of artificial teeth: Biotone (B) and Biotone interpenetrating polymer network (IPN). Materials and Methods: For each tooth, seven groups were formed (n = 10): Toothbrushing (T), toothbrushing + water (TW), toothbrushing + coke (TCk), toothbrushing + coffee (TCf), immersion in water (W), coke (Ck), coffee (Cf). Roughness and color stability evaluations were performed before treatment and after treatment. According to the group, 11,000 brushing cycles were performed and specimens were immersed in beverages for 12 days, both simulating a period of 1 year. Color variations were captured by a spectrophotometer and roughness was analyzed by a profilometer. Color data were analyzed using analysis of variance (ANOVA) and Least significant difference test whereas roughness data were analyzed using ANOVA and Bonferroni test, both with α =0.05. Results: For Biotone, clinical significant color changes according to National Bureau of Standards (NBS) units were observed for the Groups T, TW, W, and Ck, and the results of ΔE were statistically similar among them (P > 0.05). For Biotone IPN, clinical significant color changes were found for TCf (4.86 NBS units) and Cf (4.82), and the results of ΔE were also similar among them. Surface roughness Ra (μm), regardless of the teeth, was reduced for the groups submitted to toothbrushing whereas no significant differences were found among the Groups W, Ck, and Cf. Conclusions: Toothbrushing had no influence on the color stability but significantly reduced the roughness, irrespective of the type of tooth.
- 27 May 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 116 (5) , 749-755
Mandibular kinesiographic pattern of women with chronic TMD after management with educational and self-care therapies: A double-blind, randomized clinical trial
- 27 May 2016
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 116 (5) , 749-755
Mandibular kinesiographic pattern of women with chronic TMD after management with educational and self-care therapies: A double-blind, randomized clinical trial
- 24 February 2016
- Published by Wiley in Journal of Prosthodontics
- Vol. 25 (6) , 485-488
In Vitro Assessment of the Abrasion Resistance of Two Types of Artificial Teeth Submitted to Brushing
Purpose: To assess the effect of brushing with different solutions on the abrasion resistance of two types of acrylic resin teeth.Materials and Methods: Maxillary premolars from two types of acrylic teeth (Biotone and Biotone IPN) were divided into six groups (n = 12), according to the solution used during brushing: distilled water (control), coconut soap, or dentifrice. A mechanical brushing machine was used to simulate approximately 1 year of brushing (11,000 strokes). The weight loss (WL) of teeth was obtained from the difference between the initial (IW) and final weight (FW) of each specimen, and the mean of percentage of weight loss (PWL) was calculated for each group. Data were analyzed using the Kruskal‐Wallis test, followed by Bonferroni's post‐test comparison (α = 0.05).Results: A statistically significant difference was found for the factor solution (p < 0.001). Brushing using dentifrice caused the highest values of weight loss (–0.50%), in comparison with the groups brushed with coconut soap (0.00%) or distilled water (0.00%).Conclusions: For both types of artificial teeth, brushing with dentifrice produced higher abrasion than brushing with coconut soap or water.
- 24 February 2016
- Published by Wiley in Journal of Prosthodontics
- Vol. 25 (6) , 485-488
In Vitro Assessment of the Abrasion Resistance of Two Types of Artificial Teeth Submitted to Brushing
Purpose: To assess the effect of brushing with different solutions on the abrasion resistance of two types of acrylic resin teeth.Materials and Methods: Maxillary premolars from two types of acrylic teeth (Biotone and Biotone IPN) were divided into six groups (n = 12), according to the solution used during brushing: distilled water (control), coconut soap, or dentifrice. A mechanical brushing machine was used to simulate approximately 1 year of brushing (11,000 strokes). The weight loss (WL) of teeth was obtained from the difference between the initial (IW) and final weight (FW) of each specimen, and the mean of percentage of weight loss (PWL) was calculated for each group. Data were analyzed using the Kruskal‐Wallis test, followed by Bonferroni's post‐test comparison (α = 0.05).Results: A statistically significant difference was found for the factor solution (p < 0.001). Brushing using dentifrice caused the highest values of weight loss (–0.50%), in comparison with the groups brushed with coconut soap (0.00%) or distilled water (0.00%).Conclusions: For both types of artificial teeth, brushing with dentifrice produced higher abrasion than brushing with coconut soap or water.
- 5 November 2015
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 115 (4) , 462-468
Crossover clinical trial of different methods of removing a denture adhesive and the influence on the oral microbiota
- 5 November 2015
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 115 (4) , 462-468
Crossover clinical trial of different methods of removing a denture adhesive and the influence on the oral microbiota