NMNikolaos E. Makris

Nikolaos E. Makris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nikolaos E. Makris has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiologic findings of osteonecrosis, osteoradionecrosis, osteomyelitis and jaw metastatic disease with cone beam CT

    by Zafeiroula Yfanti, Sotirios Tetradis, Nikolaos G. Nikitakis, Konstantina Eleni Alexiou, Nikolaos Makris, Christos Angelopoulos, Kostas Tsiklakis


  • Open Access

    An automatic delineation method for bone marrow absorbed dose estimation in 89Zr PET/CT studies

    by N.E. Makris, R. Boellaard, C.W. Menke, A.A. Lammertsma, M.C. Huisman

    The study aims to develop and validate an automatic delineation method for estimating red bone marrow (RM) activity concentration and absorbed dose in 89Zr positron emission tomography/computed tomography (PET/CT) studies. Five patients with advanced colorectal cancer received 37.1 ± 0.9 MBq [89Zr] cetuximab within 2 h after administration of a therapeutic dose of 500 mg m−2 unlabelled cetuximab. Per patient, five PET/CT scans were acquired on a Gemini TF-64 PET/CT scanner at 1, 24, 48, 96 and 144 h post injection. Low dose CT data were used to manually generate volumes of interest (VOI) in the lumbar vertebrae (LV). In addition, LV VOI were generated automatically using an active contour method in a low dose CT. RM activity was then determined by mapping the low dose CT-derived RM VOI onto the corresponding PET scans. Finally, these activities were used to derive residence times and, subsequently, the self and total RM absorbed doses using OLINDA/EXM 1.1. High correlations (r 2 > 0.85) between manual and automated VOI methods were obtained for both RM activity concentrations and total absorbed doses. On average, the automatic method provided values that were lower than 5 % compared to the manual method. An automated and efficient VOI method, based on an active contour approach, was developed, enabling accurate estimates of RM activity concentrations and total absorbed doses.


  • Dynamic susceptibility contrast perfusion imaging in biopsy-proved adult medulloblastoma

    by Marianne Theillac, David Meyronet, Julien Savatovsky, Nikolaos Makris, Salem Hannoun, Sylvie Grand, François Cotton


  • PET/CT-Derived Whole-Body and Bone Marrow Dosimetry of 89Zr-Cetuximab

    by Nikolaos E. Makris, Ronald Boellaard, Arthur van Lingen, Adriaan A. Lammertsma, Guus A.M.S. van Dongen, Henk M. Verheul, Catharina W. Menke, Marc C. Huisman

    PET/CT imaging allows for image-based estimates of organ and red marrow (RM) residence times. The aim of this study was to derive PET/CT-based radiation dosimetry for Zr-89-cetuximab, with special emphasis on determining RM-absorbed dose. Methods: Seven patients with colorectal cancer received 36.9 +/- 0.8 MBq of Zr-89-cetuximab within 2 h after administration of a therapeutic dose of 500 mg . m(-2) of cetuximab. Whole-body PET/CT scans and blood samples were obtained at 1, 24, 48, 94, and 144 h after injection. RM activity concentrations were calculated from manual delineation of the lumbar vertebrae and blood samples, assuming a fixed RM-to-plasma activity concentration ratio (RMPR) of 0.19. The cumulated activity was calculated as the area under the curve of the organ time-activity data (liver, lungs, kidneys, spleen, and RM), assuming physical decay after the last scan. The residence time for each organ was derived by dividing the cumulated activity with the total injected activity. The residence time in the remainder of the body was calculated as the maximum possible residence time minus the sum of residence time of source organs, assuming no excretion during the time course of the scans. The (self and total) RM- and organ-absorbed doses and effective whole-body radiation dose were obtained using dose conversion factors from OLINDA/EXM 1.1. Several simplified 3-time-point dosimetry approaches were also evaluated. Results: The first approach yielded self and total RM doses of 0.17 +/- 0.04 and 0.51 +/- 0.06 mGy.MBq(-1), respectively. The second approach deviated by -21% in self-dose and -6% in total dose. RMPR increased over time in 5 of 7 patients. The highest Zr-89-absorbed dose was observed in the liver with 2.60 +/- 0.78 mGy.MBq(-1), followed by the kidneys, spleen, and lungs, whereas the effective whole-body dose was 0.61 +/- 0.09 mSv.MBq(-1). The simplified 3-time-point (1, 48, and 144 h) dosimetry approach deviated by at most 4% in both organ-absorbed doses and effective dose. Conclusion: Although the total RM dose estimates obtained with the 2 approaches differed only by at most 6%, the image-based approach is preferred because it accounts for nonconstant RMPR. The number of successive scans can be reduced to 3 without affecting effective dose estimates.


  • Evaluation of strategies towards harmonization of FDG PET/CT studies in multicentre trials: comparison of scanner validation phantoms and data analysis procedures

    by Nikolaos E. Makris, Marc C. Huisman, Paul E. Kinahan, Adriaan A. Lammertsma, Ronald Boellaard

    Purpose PET quantification based on standardized uptake values (SUV) is hampered by several factors, in particular by variability in PET acquisition settings and data analysis methods. Quantitative PET/CT studies acquired during a multicentre trial require harmonization of imaging procedures to maximize study power. The aims of this study were to determine which phantoms are most suitable for detecting differences in image quality and quantification, and which methods for defining volumes of interest (VOI) are least sensitive to these differences. Methods The most common accreditation phantoms used in oncology FDG PET/CT trials were scanned on the same scanner. These phantoms were those used by the Society of Nuclear Medicine Clinical Trials Network (SNM-CTN), the European Association of Nuclear Medicine/National Electrical Manufacturers Association (EANM/NEMA) and the American College of Radiology (ACR). In addition, tumour SUVs were derived from ten oncology whole-body examinations performed on the same PET/CT system. Both phantom and clinical data were reconstructed using different numbers of iterations, subsets and time-of-flight kernel widths. Subsequently, different VOI methods (VOIA50%, VOImax, VOI3Dpeak, VOI2Dpeak) were applied to assess the impact of changes in image reconstruction settings on SUV and recovery coefficients (RC). Results All phantoms demonstrated sensitivity for detecting changes in SUV and RC measures in response to changes in image reconstruction settings and VOI analysis methods. The SNM-CTN and EANM/NEMA phantoms showed almost equal sensitivity in detecting RC differences with changes in image characteristics. Phantom and clinical data demonstrated that the VOI analysis methods VOIA50% and VOImax gave SUV and RC values with large variability in relation to image characteristics, whereas VOI3Dpeak and VOI2Dpeak were less sensitive to these differences. Conclusion All three phantoms may be used to harmonize parameters for data acquisition, processing and analysis. However, the SNM-CTN and EANM/NEMA phantoms are the most sensitive to parameter changes and are suitable for harmonizing SUV quantification based on 3D VOIs, such as VOIA50% and VOI3Dpeak, and VOImax. Variability in SUV quantification after harmonization could be further minimized using VOI3Dpeak analysis, which was least sensitive to residual variability in image quality and quantification.