TITakahiro Itoh

Takahiro Itoh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takahiro Itoh has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Debris Flow Debris Flow Detection by Combinations of LVP Sensors and Wires

    by Takahiro Itoh, Satoshi Tagata, Takahisa Mizuyama

    Various kinds of sensors for debris flows detection have been proposed such as wire sensor, acceleration sensor, and so on. In Europe, a geophone that is based on a vibration meter is usually used though the applicability is not confirmed for debris flow detection in Japan. A wire sensor is still currently used for debris flow detection in Japan, because of its easy maintenance and measurement principle of disconnected wires. However, there is a drawback in that debris flow cannot be detected until manual maintenance is performed after the wires are disconnected. Sakura-jima is in southwest of Japan. Debris flows occur by rainfall and ash fall after eruption. Many debris flows occur and transport sediment by debris flow events. The number of debris flow occurrences is defined by the number of disconnected wires from a wire sensor, and three wires are set vertically at the height of 60 cm, 120 cm, 180 cm from the bed, respectively, to know magnitude of debris flow height. A LVP sensor has been developed and installed there for continuous detection of debris flows and modified based on technical information obtained by maintenance after debris flow events. The sensor consists of load cell (L), acceleration meter due to vibration (V) and pressure meter (P). The sensor is mainly for debris flow detection, though weight of debris flows on the bed is attempted to be measured using a small box with loadcell. Present studies introduce some examples of debris flow detections using the LVP and emphasize usage of the LVP sensor in combination with wires.


  • Open Access

    Continuous debris flow monitoring using DFLP and LVP on Sakura-jima Island

    by Takahiro Itoh, Tadaaki Iwao, Seiki Kubo, Takaya Tsurumoto, Satoshi Tagata, Misa Furuya, Takahisa Mizuyama

    Since 2010, numerous debris flows have occurred on Sakura-jima Island due to rainfall events that occurred after extensive ash deposition associated with volcanic activity. The study area included the Nojiri and Arimura rivers in the southwestern and southeastern parts of Sakura-jima, respectively. Debris flow monitoring systems consisting of loadcell and pressure sensor (DFLP) were installed to evaluate characteristics of moving weight and so on during debris flows. The systems were installed at the Arimura River No. 3 sabo dam in June in 2012 and at the Nojiri River No. 1 sabo dam in 2014. In addition, LVP (Load, Vibration and Pressure) sensors consisting of loadcells and accelerometers for measuring vibration and pressure were installed on the riverbed for debris flow detection. Modified LVP systems were installed at the Nojiri River No. 7 sabo dam in February in 2015, and at the Arimura River No. 3 sabo dam in October in 2016. Interesting characteristics of debris flows were obtained by the DFLP and LVP systems. The findings showed that the sediment concentrations of both the coarse and the suspended and liquid phases could be estimated by the DFLP systems, and several patterns of debris flows were observed by the LVP systems.


  • Open Access

    Trial for effective sediment runoff control with a movable shutter in Joganji River

    by Koso Mikami, Tomoyuki Noro, Takahiko Nagayama, Tomohiko Furuya, Masaharu Fujita, Takahisa Mizuyama, Takahiro Itoh

  • Open Access

    Multiple debris flow surges monitored directly by DFLP system at Kamikamihori Creek

    by Takahiro Itoh, Takahiko Nagayama, Satoru Matsuda, Takahisa Mizuyama

    The monitoring method for direct debris flow measurements using loadcells and so on, that were preliminary developed by WSL in Switzerland (McArdell et al., 2007), was firstly installed in Sakura-jima Island in Japan, where volcanic activity was severe, and many debris flows took place due to deposition of falling ash after eruptions. Debris Flow measurements with Loadcells and Pressure sensors (DFLP) system was installed referring to the method by WSL, and debris flow characteristics such as specific weight and volumetric sediment concentration have been obtained (e.g., Osaka et al., 2014). In Japan, as well as in Sakura-jima island, attempts for debris flow monitoring were also carried out at KamiKamihori Creek since 1970s (e.g., Okuda et al., 1980), and there were a lot of debris flow events due to heavy rainfall. KamiKamihori Creek is at western side of Mt. Yake, where volcanic activity was severe at those time. The DFLP system was modified and installed there in November in 2014, because there were a lot of sediment deposition and debris flows took place though volcanic activity has been inactive. Present research could report the following results.  (1) Multiple debris floe over five surges were monitored using DFLP system installed in 2014 during 15 minutes in debris flow events on August 29th, 2019. Rainfall intensity for 10 minutes was 12 mm and accumulated depth was 56 mm just before those events. Antecedent time before those events was 4.5 hours.(2) The DFLP system measured multiple debris flow surges in events on August 29th, 2019, and sediment concentration was calculated temporary and continuously. Time-averaged sediment concentration and relative mass density are calculated as 0.470 and 1.73, respectively, under flow discharge obtained by images analysis of CCTV video camera. Equilibrium sediment concentration of coarse sediment particles is estimated 0.160 for bed slope of 0.141 (8 degrees) and calculated value using the DFLP system is over than the equilibrium value because of mud phase due to fine sediment particles. ReferencesMcArdell B.W., Bartelt P., Kowalski J. (2007). Field observations of basal forces and fluid pore pressure in a debris flow, Geophysical Research Letters, Vo. 34, L07406.Okuda, S., Suwa, H., Okunishi, K., Yokoyama, K., and Nakano, M. (1980). Observation of the motion of debris flow and its geomorphological effects, Zeitschrift fur Geomorphology, Suppl.-Bd.35, pp. 142–163.Osaka T., Utsunomiya R., Tagata S., Itoh T., Mizuyama T. (2014). Debris Flow Monitoring using Load Cells in Sakurajima Island, Proceedings of the Interpraevent 2014 in the Pacific Rim (edited by Fujita, M. et al.), Nov. 25-28, Nara, Japan, 2014, O-14.pdf in DVD.

  • Development of new sensor systems for continuous bedload monitoring using a submerged load‐cell system (SLS)

    by Takahiro Itoh, Takahiko Nagayama, Rei Utsunomiya, Masaharu Fujita, Daizo Tsutsumi, Shusuke Miyata, Takahisa Mizuyama

    It is important to evaluate bedload discharge and temporal changes of the bed surface, and bed deformation can be estimated during floods if the bedload discharge is properly evaluated in an arbitrary cross‐section. With the exception of grain size and its distribution within the bedload, bedload discharge has been measured using both direct and indirect methods. Bedload slot is a direct method but cannot be used to measure bedload during a flood because of volume limitations. Indirect methods require correlation between the signals and sediment volume measured using another method. In the present study, a small, automatically recording bedload sensor with an iron plate and a pair of load cells is developed in order to evaluate not only large particles but also sand particles as bedload. Bedload mass is calculated by integrating with respect to both the velocity of sediment particles and the averaged particle weight as measured by a pair of load cells, and, as an example, the velocity is estimated by the cross‐correlation function of weights measured by load cells. The applicability of the proposed sensor is discussed based on the results of flume tests in the laboratory (2014) and the observation flume of the Hodaka Sedimentation Observatory of Kyoto University in Japan (2015). The system was installed in the observation flume in November of 2012, and flume data were obtained using natural sediment particles. In particular, it was difficult to estimate the velocity of averaged bedload particles, and it was better to apply a cross‐correlation function in the laboratory tests. However, it appears that the previous estimation can estimate these velocities in the observation flume using a connecting tube and submerged load‐cell systems. Copyright © 2017 John Wiley & Sons, Ltd.


  • Detection of unusual very-long-chain fatty acid and ether lipid derivatives in the fibroblasts and plasma of patients with peroxisomal diseases using liquid chromatography-mass spectrometry

    by Shigeo Takashima, Kayoko Toyoshi, Takahiro Itoh, Naomi Kajiwara, Ayako Honda, Akiko Ohba, Shoko Takemoto, Satoshi Yoshida, Nobuyuki Shimozawa


  • Development and installation of bedload monitoring systems with submerged load cells

    by Ken Goto, Takahiro Itoh, Takahiko Nagayama, Rei Utsunomiya, Daizo Tsutsumi, Takahisa Mizuyama