Giustina Casagrande
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Giustina Casagrande has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Maria Laura Costantino
Politecnico di Milano, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, LaBS, Milan, Italy
11 shared publications Maria Laura Costantino
Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Milano, Italy
10 shared publicationsCamilla Bianchi
Depatments of Chemistry, Material and Chemical Engineering, Politecnico di Milano, Milano, Italy
6 shared publicationsGiuseppe Rombolà
Nephrology and Dialysis Unit Multimedica Clinica San Giuseppe Milan Italy
6 shared publicationsClaudio Minoretti
Depatments of Nephrology and Dialysis, Sant'Anna Hospital, Como, Italy
5 shared publicationsDomenico Vito
Depatments of Chemistry, Material and Chemical Engineering, Politecnico di Milano, Milano, Italy
5 shared publications
Latest Publications
- Open Access
- 20 May 2026
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 180, 105058
How to determine when data incompleteness compromises the correct training of data-enhanced mechanical models of haemodialysis? A data quality criterion
- 20 May 2026
- Published by Elsevier in Journal of Biomedical Informatics
- Vol. 180, 105058
Open AccessHow to determine when data incompleteness compromises the correct training of data-enhanced mechanical models of haemodialysis? A data quality criterion
- Open Access
- 19 February 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (5) , 1128-1137
A Microfluidic Approach for Intracellular Delivery into Red Blood Cells: A Deeper Understanding of the Role of Chemical/Rheological Properties of the Cellular Suspension
Red Blood Cells (RBCs) are a promising drug delivery system candidate for many drugs. Using autologous cells helps to overcome biocompatibility issues, while microfluidics allows accurate control of the intracellular delivery of molecules through fluidic shear stress. With the ultimate goal of exploiting this delivery technique for clinical applications, we investigate how the chemical/rheological characteristics of the suspension and the properties of the RBCs in different animals influence the delivery mechanism. As regard the suspension of RBC, we study the effects induced by the hematocrit and by the presence of proteins such as albumin (Bovine Serum Albumin—BSA). Regarding the cellular properties of RBCs, we aim to investigate the exportability of the technique to the RBC of the most used animal models and identify the most suitable one. The presence of BSA implies a more significant variability of the intracellular delivery. However, 70 ÷ 94% of the cells have successfully encapsulated the probe molecule. Regarding the effect of hematocrit, however, the implementation of the experiment is more challenging due to the increase in viscosity and the easier sedimentation at low flow rates. Evaluation of intracellular delivery in the RBCs of various animal samples has instead led to the proposal of the mouse as the most suitable model for preclinical studies on this particular delivery approach.
- 19 February 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (5) , 1128-1137
Open AccessA Microfluidic Approach for Intracellular Delivery into Red Blood Cells: A Deeper Understanding of the Role of Chemical/Rheological Properties of the Cellular Suspension
Red Blood Cells (RBCs) are a promising drug delivery system candidate for many drugs. Using autologous cells helps to overcome biocompatibility issues, while microfluidics allows accurate control of the intracellular delivery of molecules through fluidic shear stress. With the ultimate goal of exploiting this delivery technique for clinical applications, we investigate how the chemical/rheological characteristics of the suspension and the properties of the RBCs in different animals influence the delivery mechanism. As regard the suspension of RBC, we study the effects induced by the hematocrit and by the presence of proteins such as albumin (Bovine Serum Albumin—BSA). Regarding the cellular properties of RBCs, we aim to investigate the exportability of the technique to the RBC of the most used animal models and identify the most suitable one. The presence of BSA implies a more significant variability of the intracellular delivery. However, 70 ÷ 94% of the cells have successfully encapsulated the probe molecule. Regarding the effect of hematocrit, however, the implementation of the experiment is more challenging due to the increase in viscosity and the easier sedimentation at low flow rates. Evaluation of intracellular delivery in the RBCs of various animal samples has instead led to the proposal of the mouse as the most suitable model for preclinical studies on this particular delivery approach.
- Open Access
- 20 December 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1741, 465614
Methylcellulose enhances resolution in gravitational field-flow fractionation: Going beyond viscosity
- 20 December 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1741, 465614
Open AccessMethylcellulose enhances resolution in gravitational field-flow fractionation: Going beyond viscosity
- 5 June 2024
- Published by Wiley in Artificial Organs
- Vol. 48 (10) , 1200-1210
Same therapy, same calcium mobilization? Exploring calcium exchange across body compartments using a patient‐specific predictive model
Background: Comprehensive, patient‐specific models are essential to study calcium deposition and mobilization during dialysis. We aim to develop tools to support clinical prescriptions with a more accurate approach for the prediction of calcium mobilization while also considering major electrolytes and catabolites.Methods: We modified a multi‐solute model predicting patient‐specific dialysis response by incorporating a calcium buffer to represent bone exchanges. Data from four centers, involving 127 patients with six sessions each, were utilized. For each patient, three sessions were allocated for model training (ID123), while the remaining sessions were for validation (PRED456). The normalized root mean square error (nRMSE%) was used to evaluate both descriptive and predictive accuracy. Correlations between initial data and calcium exchanges were also assessed.Results: The overall nRMSE% for ID123 was 3.92%. For PRED456, it was 3.46% (ranging from a minimum of 1.17% for [Na+] to a maximum of 6.62% for [urea]). The median nRMSE% for plasma calcium varied between 1.13 and 8.32 for SHD sessions, depending on whether Ca_dialysis fluid (Cad) was ≥ or <1.50 mmol/L, respectively. For HDF sessions, the range was between 2.90 and 5.89. A significant and moderate correlation was found between overall calcium removal and the buffer balance. The most robust correlation observed was between the amount of calcium administered via post‐dilution fluid and the overall calcium removal in the dialysis filter.Conclusions: Identical therapy settings do not uniformly affect calcium mobilization, and our approach offers insight into calcium distribution across body compartments. This understanding will enhance clinical prescription practices.
- 5 June 2024
- Published by Wiley in Artificial Organs
- Vol. 48 (10) , 1200-1210
Same therapy, same calcium mobilization? Exploring calcium exchange across body compartments using a patient‐specific predictive model
Background: Comprehensive, patient‐specific models are essential to study calcium deposition and mobilization during dialysis. We aim to develop tools to support clinical prescriptions with a more accurate approach for the prediction of calcium mobilization while also considering major electrolytes and catabolites.Methods: We modified a multi‐solute model predicting patient‐specific dialysis response by incorporating a calcium buffer to represent bone exchanges. Data from four centers, involving 127 patients with six sessions each, were utilized. For each patient, three sessions were allocated for model training (ID123), while the remaining sessions were for validation (PRED456). The normalized root mean square error (nRMSE%) was used to evaluate both descriptive and predictive accuracy. Correlations between initial data and calcium exchanges were also assessed.Results: The overall nRMSE% for ID123 was 3.92%. For PRED456, it was 3.46% (ranging from a minimum of 1.17% for [Na+] to a maximum of 6.62% for [urea]). The median nRMSE% for plasma calcium varied between 1.13 and 8.32 for SHD sessions, depending on whether Ca_dialysis fluid (Cad) was ≥ or <1.50 mmol/L, respectively. For HDF sessions, the range was between 2.90 and 5.89. A significant and moderate correlation was found between overall calcium removal and the buffer balance. The most robust correlation observed was between the amount of calcium administered via post‐dilution fluid and the overall calcium removal in the dialysis filter.Conclusions: Identical therapy settings do not uniformly affect calcium mobilization, and our approach offers insight into calcium distribution across body compartments. This understanding will enhance clinical prescription practices.
- Open Access
- 14 June 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 38 (Supplement)
#3989 INTERACTIVE-HD 2.0 PROJECT – PRELIMINARY RESULTS OF LUGANO DATASET
Computational models can be used in nephrology and dialysis divisions in order to predict the intradialytic trends of the main electrolytes, breakdown products, and body fluids volumes. However, predictive models need to be trained with consistent clinical data for a certain amount of HD sessions: if successfully trained, these models can be a useful support tool for a therapy customization, mainly needed for ESRD patients characterized by multiple comorbidities. Strength and limits of similar approaches have to be evaluated before their daily clinical use. where the subscript i stands for the ith of N intradialytic acquisition time-points, while CLIN and MOD refer to the clinically measured data of interest and to the model simulated ones, respectively; y is the variable of interest, i.e., electrolytes’ hematic concentrations. Inter-stratification variability in terms of model performance has been analysed via a Kruskal-Wallis test. From the results’ stratification, it can be observed a good ability of the model to describe all variables, without bias with respect to pathologies in the short term. From 2 months onwards, the presence of hypertension, alone (n = 23), or the presence of cardiovascular diseases, alone (n = 38), leads to an increase in the error. Error that is instead very limited in the main group of patients (n = 229). Regarding age groups’ stratification, all variables are well simulated in the short term; however, already at 2 months, it is highlighted an increase in the error only for patients under 70 years of age (n = 87). On the other hand, for patients older than 70 years (n = 203), the stratification shows more stability. Finally, regarding the stratification based on the presence of diabetes, it can be observed that glycaemia is no longer simulated well only in insulin-dependent patients (n = 75) compared to non-insulin-dependent patients (n = 89) around 5 months; in the case of insulin-dependent patients, for K+ and urea the model should take into account some other phenomenon to be modelled as they are tracked with lower precision already in the short term. The stratification highlighted that hypertensive patients should be reevaluated more often, preferably two months after the first training of the model. Moreover, it was observed that the most sensitive group is the one with patients under 70 years of age, thus requiring re-evaluation, already at 2 months; on the other hand, for patients older than 70 years, in the absence of other pathologies, this re-evaluation can be postponed at least 7 months. Finally, the ability to simulate blood glucose is always acceptable in the 7 months, except for insulin-dependent patients in whom a re-evaluation between 2 and 5 months is necessary. Either way, given the general results and what the stratifications have evidenced, we claim the clinical effort is worth it and the model can represent an important support for clinical decisions.
- 14 June 2023
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 38 (Supplement)
Open Access#3989 INTERACTIVE-HD 2.0 PROJECT – PRELIMINARY RESULTS OF LUGANO DATASET
Computational models can be used in nephrology and dialysis divisions in order to predict the intradialytic trends of the main electrolytes, breakdown products, and body fluids volumes. However, predictive models need to be trained with consistent clinical data for a certain amount of HD sessions: if successfully trained, these models can be a useful support tool for a therapy customization, mainly needed for ESRD patients characterized by multiple comorbidities. Strength and limits of similar approaches have to be evaluated before their daily clinical use. where the subscript i stands for the ith of N intradialytic acquisition time-points, while CLIN and MOD refer to the clinically measured data of interest and to the model simulated ones, respectively; y is the variable of interest, i.e., electrolytes’ hematic concentrations. Inter-stratification variability in terms of model performance has been analysed via a Kruskal-Wallis test. From the results’ stratification, it can be observed a good ability of the model to describe all variables, without bias with respect to pathologies in the short term. From 2 months onwards, the presence of hypertension, alone (n = 23), or the presence of cardiovascular diseases, alone (n = 38), leads to an increase in the error. Error that is instead very limited in the main group of patients (n = 229). Regarding age groups’ stratification, all variables are well simulated in the short term; however, already at 2 months, it is highlighted an increase in the error only for patients under 70 years of age (n = 87). On the other hand, for patients older than 70 years (n = 203), the stratification shows more stability. Finally, regarding the stratification based on the presence of diabetes, it can be observed that glycaemia is no longer simulated well only in insulin-dependent patients (n = 75) compared to non-insulin-dependent patients (n = 89) around 5 months; in the case of insulin-dependent patients, for K+ and urea the model should take into account some other phenomenon to be modelled as they are tracked with lower precision already in the short term. The stratification highlighted that hypertensive patients should be reevaluated more often, preferably two months after the first training of the model. Moreover, it was observed that the most sensitive group is the one with patients under 70 years of age, thus requiring re-evaluation, already at 2 months; on the other hand, for patients older than 70 years, in the absence of other pathologies, this re-evaluation can be postponed at least 7 months. Finally, the ability to simulate blood glucose is always acceptable in the 7 months, except for insulin-dependent patients in whom a re-evaluation between 2 and 5 months is necessary. Either way, given the general results and what the stratifications have evidenced, we claim the clinical effort is worth it and the model can represent an important support for clinical decisions.
- Open Access
- 10 April 2023
- Published by Wiley in Artificial Organs
- Vol. 47 (8) , 1326-1341
Can the response to dialysis treatment be predicted by using patient‐specific modeling of fluid and solute exchanges? A multicentric evaluation
Background: Parametric multipool kinetic models were used to describe the intradialytic trends of electrolytes, breakdown products, and body fluids volumes during hemodialysis. Therapy customization can be achieved by the identification of parameters, allowing patient‐specific modulation of mass and fluid balance across dialyzer, capillary, and cell membranes. This study wants to evaluate the possibility to use this approach to predict the patient's intradialytic response. Methods: 6 sessions of 68 patients (DialysIS© project) were considered. Data from the first three sessions were used to train the model, identifying the patient‐specific parameters, that, together with the treatment settings and the patient's data at the session start, could be used for predicting the patient's specific time course of solutes and fluids along the sessions. Na + , K + , Cl − , Ca 2+ , HCO 3 − , and urea plasmatic concentrations and hematic volume deviations from clinical data were evaluated. Results: nRMSE predictive error is on average equal to 4.76% when describing the training sessions, and only increases by 0.97 percentage points on average in independent sessions of the same patient. Conclusions: The proposed predictive approach represents a first step in the development of tools to support the clinician in tailoring the patient's prescription.
- 10 April 2023
- Published by Wiley in Artificial Organs
- Vol. 47 (8) , 1326-1341
Open AccessCan the response to dialysis treatment be predicted by using patient‐specific modeling of fluid and solute exchanges? A multicentric evaluation
Background: Parametric multipool kinetic models were used to describe the intradialytic trends of electrolytes, breakdown products, and body fluids volumes during hemodialysis. Therapy customization can be achieved by the identification of parameters, allowing patient‐specific modulation of mass and fluid balance across dialyzer, capillary, and cell membranes. This study wants to evaluate the possibility to use this approach to predict the patient's intradialytic response. Methods: 6 sessions of 68 patients (DialysIS© project) were considered. Data from the first three sessions were used to train the model, identifying the patient‐specific parameters, that, together with the treatment settings and the patient's data at the session start, could be used for predicting the patient's specific time course of solutes and fluids along the sessions. Na + , K + , Cl − , Ca 2+ , HCO 3 − , and urea plasmatic concentrations and hematic volume deviations from clinical data were evaluated. Results: nRMSE predictive error is on average equal to 4.76% when describing the training sessions, and only increases by 0.97 percentage points on average in independent sessions of the same patient. Conclusions: The proposed predictive approach represents a first step in the development of tools to support the clinician in tailoring the patient's prescription.
- 28 December 2022
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 173, 104975
A comparative study of the definitions of intradialytic hypotension correlated with increased mortality to identify universal predictors
- 28 December 2022
- Published by Elsevier in International Journal of Medical Informatics
- Vol. 173, 104975
A comparative study of the definitions of intradialytic hypotension correlated with increased mortality to identify universal predictors
- 20 July 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (15) , 1215-1224
A global sensitivity analysis approach applied to a multiscale model of microvascular flow
A global sensitivity analysis of a multiscale computational model of microvascular flow is presented. A total of 140 simulations have been completed and analyzed varying 6 input parameters and considering their effects on 7 output variables. Interestingly, the vascular network topology has been found as a determinant factor for both vasculature-related and interstitium-related quantities. Regarding the firsts, the vascular network topology has obtained a score of 5.5/6 and 6/6 for average and spatial distribution respectively (where 6 is the maximum and 1 is the minimum). On the other hand, considering interstitium-related quantities, the score is 4/6 and 5/6 for average and spatial distribution respectively. These results suggest that the network topology has a significant influence on the outcome of the computational analysis.
- 20 July 2020
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 23 (15) , 1215-1224
A global sensitivity analysis approach applied to a multiscale model of microvascular flow
A global sensitivity analysis of a multiscale computational model of microvascular flow is presented. A total of 140 simulations have been completed and analyzed varying 6 input parameters and considering their effects on 7 output variables. Interestingly, the vascular network topology has been found as a determinant factor for both vasculature-related and interstitium-related quantities. Regarding the firsts, the vascular network topology has obtained a score of 5.5/6 and 6/6 for average and spatial distribution respectively (where 6 is the maximum and 1 is the minimum). On the other hand, considering interstitium-related quantities, the score is 4/6 and 5/6 for average and spatial distribution respectively. These results suggest that the network topology has a significant influence on the outcome of the computational analysis.
- 13 August 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 48 (1) , 236-246
Shear-Induced Encapsulation into Red Blood Cells: A New Microfluidic Approach to Drug Delivery
Encapsulating molecules into red blood cells (RBCs) is a challenging topic for drug delivery in clinical practice, allowing to prolong the residence time in the body and to avoid toxic residuals. Fluidic shear stress is able to temporary open the membrane pores of RBCs, thus allowing for the diffusion of a drug in solution with the cells. In this paper, both a computational and an experimental approach were used to investigate the mechanism of shear-induced encapsulation in a microchannel. By means of a computational fluid dynamic model of a cell suspension, it was possible to calculate an encapsulation index that accounts for the effective shear acting on the cells, their distribution in the cross section of the microchannel and their velocity. The computational model was then validated with micro-PIV measurements on a RBCs suspension. Finally, experimental tests with a microfluidic channel showed that, by choosing the proper concentration and fluid flow rate, it is possible to successfully encapsulate a test molecule (FITC-Dextran, 40 kDa) into human RBCs. Cytofluorimetric analysis and confocal microscopy were used to assess the RBCs physiological shape preservation and confirm the presence of fluorescent molecules inside the cells.
- 13 August 2019
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 48 (1) , 236-246
Shear-Induced Encapsulation into Red Blood Cells: A New Microfluidic Approach to Drug Delivery
Encapsulating molecules into red blood cells (RBCs) is a challenging topic for drug delivery in clinical practice, allowing to prolong the residence time in the body and to avoid toxic residuals. Fluidic shear stress is able to temporary open the membrane pores of RBCs, thus allowing for the diffusion of a drug in solution with the cells. In this paper, both a computational and an experimental approach were used to investigate the mechanism of shear-induced encapsulation in a microchannel. By means of a computational fluid dynamic model of a cell suspension, it was possible to calculate an encapsulation index that accounts for the effective shear acting on the cells, their distribution in the cross section of the microchannel and their velocity. The computational model was then validated with micro-PIV measurements on a RBCs suspension. Finally, experimental tests with a microfluidic channel showed that, by choosing the proper concentration and fluid flow rate, it is possible to successfully encapsulate a test molecule (FITC-Dextran, 40 kDa) into human RBCs. Cytofluorimetric analysis and confocal microscopy were used to assess the RBCs physiological shape preservation and confirm the presence of fluorescent molecules inside the cells.
- 1 March 2019
- Published by Elsevier in Microvascular Research
- Vol. 122, 101-110
Numerical simulations of the microvascular fluid balance with a non-linear model of the lymphatic system
- 1 March 2019
- Published by Elsevier in Microvascular Research
- Vol. 122, 101-110
Numerical simulations of the microvascular fluid balance with a non-linear model of the lymphatic system